Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXHAUST GAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Residual life assessment of the SSME/ATD HPOTP turnaround duct (TAD)

This paper is concerned with the prediction of the low cycle thermal fatigue behavior of a component in a developmental (ATD) high pressure liquid oxygen turbopump (HPOTP) for the Space Shuttle Main Engine (SSME). This component is called the Turnaround Duct (TAD). The TAD is a complex single piece casting of MAR-M-247 material. Its function is to turn the hot turbine exhaust gas (1200 F hydrogen rich gas steam) such that it can exhaust radially out of the turbopump. In very simple terms, the TAD consists of two rings connected axially by 22 hollow airfoil shaped struts with the turning vanes placed at the top, middle, and bottom of each strut. The TAD is attached to the other components of the pump via bolts passing through 14 of the 22 struts. Of the remaining 8 struts, four are equally spaced (90 deg interval) and containing a cooling tube through which liquid hydrogen passes on its way to cool the shaft bearing assemblies. The remaining 4 struts are empty. One of the pump units in the certification test series was destructively examined after 22 test firings. Substantial axial cracking was found in two of the struts which contain cooling tubes. None of the other 20 struts showed any sign of internal cracking. This unusual low cycle thermal fatigue behavior within the two cooling tube struts is the focus of this study.

Gross, R. Steven↗

Experimental Investigation of Fuel-Reactivity Controlled Compression Ignition (RCCI) Combustion Mode in a Multi-Cylinder, Light-Duty Diesel Engine

An experimental study was performed to provide the combustion and emission characteristics resulting from fuel-reactivity controlled compression ignition (RCCI) combustion mode utilizing dual-fuel approach in a light-duty, multi-cylinder diesel engine. In-cylinder fuel blending using port fuel injection of gasoline before intake valve opening (IVO) and early-cycle, direct injection of diesel fuel was used as the charge preparation and fuel blending strategy. In order to achieve the desired auto-ignition quality through the stratification of the fuel-air equivalence ratio ( ), blends of commercially available gasoline and diesel fuel were used. Engine experiments were performed at an engine speed of 2300rpm and an engine load of 4.3bar brake mean effective pressure (BMEP). It was found that significant reduction in both nitrogen oxide (NOx) and particulate matter (PM) was realized successfully through the RCCI combustion mode even without applying exhaust gas recirculation (EGR). However, high carbon monoxide (CO) and hydrocarbon (HC) emissions were observed. The low combustion gas temperature during the expansion and exhaust processes seemed to be the dominant source of high CO emissions in the RCCI combustion mode. The high HC emissions during the RCCI combustion mode could be due to the increased combustion quenching layer thickness as well as the -stratification at the periphery of the combustion chamber. The slightly higher brake thermal efficiency (BTE) of the RCCI combustion mode was observed than the other combustion modes, such as the conventional diesel combustion (CDC) mode, and single-fuel, premixed charge compression ignition (PCCI) combustion mode. The parametric study of the RCCI combustion mode revealed that the combustion phasing and/or the peak cylinder pressure rise rate of the RCCI combustion mode could be controlled by several physical parameters premixed ratio (rp), intake swirl intensity, and start of injection (SOI) timing of directly injected fuel unlike other low temperature combustion (LTC) strategies.

02 PETROLEUM↗

Air separation membranes : an alternative to EGR in large bore natural gas engines.

Air separation membranes (ASMs) could potentially replace exhaust gas recirculation (EGR) technology in engines due to the proven benefits in NOx reduction but without the drawbacks of EGR. Previous investigations of nitrogen-enriched air (NEA) combustion using nitrogen bottles showed up to 70% NOx reduction with modest 2% nitrogen enrichment. The investigation in this paper was performed with an ASM capable of delivering at least 3.5% NEA to a single-cylinder spark-ignited natural gas engine. Low temperature combustion is one of the pathways to meet the mandatory ultra low NOx emissions levels set by regulatory agencies. In this study, a comparative assessment is made between natural gas combustion in standard air and 2% NEA. Enrichment beyond this level degraded engine performance in terms of power density, brake thermal efficiency (BTE), and unburned hydrocarbon emissions for a given equivalence ratio. The ignition timing was optimized to yield maximum brake torque for standard air and NEA. Subsequently, conventional spark ignition was replaced by laser ignition (LI) to extend lean ignition limit. Both ignition systems were studied under a wide operating range from {Psi} :1.0 to the lean misfire limit. It was observed that with 2% NEA, for a similar fuel quantity, the equivalence ratio {Psi} increases by 0.1 relative to standard air conditions. Analysis showed that lean burn operation along with NEA and alternative ignition source, such as LI, could pave the pathway for realizing lower NO{sub x} emissions with a slight penalty in BTE.

03 NATURAL GAS↗

Final Report: Assessment of Combined Heat and Power Premium Power Applications in California

This report analyzes the current economic and environmental performance of combined heat and power (CHP) systems in power interruption intolerant commercial facilities. Through a series of three case studies, key trade-offs are analyzed with regard to the provision of black-out ridethrough capability with the CHP systems and the resutling ability to avoid the need for at least some diesel backup generator capacity located at the case study sites. Each of the selected sites currently have a CHP or combined heating, cooling, and power (CCHP) system in addition to diesel backup generators. In all cases the CHP/CCHP system have a small fraction of the electrical capacity of the diesel generators. Although none of the selected sites currently have the ability to run the CHP systems as emergency backup power, all could be retrofitted to provide this blackout ride-through capability, and new CHP systems can be installed with this capability. The following three sites/systems were used for this analysis: (1) Sierra Nevada Brewery - Using 1MW of installed Molten Carbonate Fuel Cells operating on a combination of digestor gas (from the beer brewing process) and natural gas, this facility can produce electricty and heat for the brewery and attached bottling plant. The major thermal load on-site is to keep the brewing tanks at appropriate temperatures. (2) NetApp Data Center - Using 1.125 MW of Hess Microgen natural gas fired reciprocating engine-generators, with exhaust gas and jacket water heat recovery attached to over 300 tons of of adsorption chillers, this combined cooling and power system provides electricity and cooling to a data center with a 1,200 kW peak electrical load. (3) Kaiser Permanente Hayward Hospital - With 180kW of Tecogen natural gas fired reciprocating engine-generators this CHP system generates steam for space heating, and hot water for a city hospital. For all sites, similar assumptions are made about the economic and technological constraints of the power generation system. Using the Distributed Energy Resource Customer Adoption Model (DER-CAM) developed at the Lawrence Berkeley National Laboratory, we model three representative scenarios and find the optimal operation scheduling, yearly energy cost, and energy technology investments for each scenario below: Scenario 1 - Diesel generators and CHP/CCHP equipment as installed in the current facility. Scenario 1 represents a baseline forced investment in currently installed energy equipment. Scenario 2 - Existing CHP equipment installed with blackout ride-through capability to replace approximately the same capacity of diesel generators. In Scenario 2 the cost of the replaced diesel units is saved, however additional capital cost for the controls and switchgear for blackout ride-through capability is necessary. Scenario 3 - Fully optimized site analysis, allowing DER-CAM to specify the number of diesel and CHP/CCHP units (with blackout ride-through capability) that should be installed ignoring any constraints on backup generation. Scenario 3 allows DER-CAM to optimize scheduling and number of generation units from the currently available technologies at a particular site. The results of this analysis, using real data to model the optimal schedulding of hypothetical and actual CHP systems for a brewery, data center, and hospital, lead to some interesting conclusions. First, facilities with high heating loads will typically prove to be the most appropriate for CHP installation from a purely economic standpoint. Second, absorption/adsorption cooling systems may only be economically feasible if the technology for these chillers can increase above current best system efficiency. At a coefficient of performance (COP) of 0.8, for instance, an adsorption chiller paired with a natural gas generator with waste heat recovery at a facility with large cooling loads, like a data center, will cost no less on a yearly basis than purchasing electricity and natural gas directly from a utility. Third, at marginal additional cost, if the reliability of CHP systems proves to be at least as high as diesel generators (which we expect to be the case), the CHP system could replace the diesel generator at little or no additional cost. This is true if the thermal to electric (relative) load of those facilities was already high enough to economically justify a CHP system. Last, in terms of greenhouse gas emissions, the modeled CHP and CCHP systems provide some degree of decreased emissions relative to systems with less CHP installed. The emission reduction can be up to 10% in the optimized case (Scenario 3) in the application with the highest relative thermal load, in this case the hospital. Although these results should be qualified because they are only based on the three case studies, the general results and lessons learned are expected to be applicable across a broad range of potential and existing CCHP systems.

25 ENERGY STORAGE↗

Drive cycle analysis of butanol/diesel blends in a light-duty vehicle.

The potential exists to displace a portion of the petroleum diesel demand with butanol and positively impact engine-out particulate matter. As a preliminary investigation, 20% and 40% by volume blends of butanol with ultra low sulfur diesel fuel were operated in a 1999 Mercedes Benz C220 turbo diesel vehicle (Euro III compliant). Cold and hot start urban as well as highway drive cycle tests were performed for the two blends of butanol and compared to diesel fuel. In addition, 35 MPH and 55 MPH steady-state tests were conducted under varying road loads for the two fuel blends. Exhaust gas emissions, fuel consumption, and intake and exhaust temperatures were acquired for each test condition. Filter smoke numbers were also acquired during the steady-state tests.

02 PETROLEUM↗

Effect of water injection on nitric oxide emissions of a gas turbine combustor burning natural gas fuel

The effect of direct water injection on the exhaust gas emissions of a turbojet combustor burning natural gas fuel was investigated. The results are compared with the results from similar tests using ASTM Jet-A fuel. Increasing water injection decreased the emissions of oxides of nitrogen (NOX) and increased the emissions of carbon monoxide and unburned hydrocarbons. The greatest percentage decrease in NOX with increasing water injection was at the lowest inlet-air temperature tested. The effect of increasing inlet-air temperature was to decrease the effect of the water injection. The reduction in NOX due to water injection was almost identical to the results obtained with Jet-A fuel. However, the emission indices of unburned hydrocarbons, carbon monoxide, and percentage nitric oxide in NOX were not.

Marchionna, N. R.↗

Effect of Inlet-air-flow Distortions on Steady-state Performance of J65-B-3 Turbojet Engine

The effects of inlet-air-flow distortions on the performance of the J65-B-3 turbojet engine were determined over a range of altitudes from 15,000 to 50,000 feet at a flight Mach number of 0.8. Radial inlet-air-flow distortions apparently do not affect the radial distribution of pressure after the first few compressor stages, while the circumferential inlet-air-flow distortion carried completely through the engine. For the distortions investigated, at rated exhaust-gas temperature and fixed-area exhaust-nozzle operation, the primary effect of the radial inlet-air-flow distortions was to reduce the engine air flow, and the primary effect of the circumferential distortion was to impose a temperature profile on the turbine, both resulting in reduction of thrust.

Smith, Ivan D↗

System and method for cooling a combustion gas charge

The present invention relates to a system and method for cooling a combustion gas charge prior. The combustion gas charge may include compressed intake air, exhaust gas, or a mixture thereof. An evaporator is provided that may then receive a relatively high temperature combustion gas charge and discharge at a relatively lower temperature. The evaporator may be configured to operate with refrigeration cycle components and/or to receive a fluid below atmospheric pressure as the phase-change cooling medium.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of nitric oxide and exhaust gases on gasoline surrogate autoignition: iso-octane experiments and modeling

Exhaust gas recirculation (EGR) is widely used in advanced internal combustion engines to reduce engine emissions as well as control combustion phasing. Among various species present in EGR gases, CO 2 and H 2 O are two major components that can thermally and chemically affect fuel autoignition. It is of fundamental interest to isolate the thermal and chemical effects of CO 2 and H 2 O on fuel autoignition, especially as such an effort has not been reported in the literature. Moreover, nitric oxide (NO) is known to exhibit strong chemical effects on fuel autoignition, which in turn affects engine combustion phasing. The effects of ultra-low NO addition (< 100 ppm) on fuel autoignition at low temperatures are also not well understood. Recognizing these problems, autoignition experiments of iso-octane (a major gasoline surrogate component) in air are performed in this study using a rapid compression machine at varying compressed pressures, equivalence ratios, dilution levels with an EGR gas analogue (consisting of CO 2 , H 2 O, O 2 , and N 2 ) and N 2 only, and varying amounts of NO addition. Furthermore, the thermal and chemical effects of the EGR gas analogue are isolated and evaluated by comparing the ignition delay time datasets of EGR and N2-only diluted cases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing dilute combustion instabilities in a multi-cylinder spark-ignited engine using symbolic analysis

Spark-ignited internal combustion engines have evolved considerably in recent years in response to increasingly stringent regulations for emissions and fuel-economy. One new advanced engine strategy utilizes high levels of exhaust gas recirculation (EGR) to reduce combustion temperatures, thereby increasing thermodynamic efficiency and reducing nitrogen oxide emissions. While this strategy can be highly effective, it also poses major control and design challenges due to the large combustion oscillations that develop at sufficiently high EGR levels. Previous research has documented that combustion instabilities can propagate between successive engine cycles in individual cylinders via self-generated feedback of reactive species and thermal energy in the retained residual exhaust gases. In this work, we use symbolic analysis to characterize multi-cylinder combustion oscillations in an experimental engine operating with external EGR. At low levels of EGR, intra-cylinder oscillations are clearly visible and appear to be associated with brief, intermittent coupling among cylinders. As EGR is increased further, a point is reached where all four cylinders lock almost completely in phase and alternate simultaneously between two distinct bi-stable combustion states. From a practical perspective, it is important to understand the causes of this phenomenon and develop diagnostics that might be applied to ameliorate its effects. We demonstrate here that two approaches for symbolizing the engine combustion measurements can provide useful probes for characterizing these instabilities.

42 ENGINEERING↗

EGR Dilution and Fuel Property Effects on High-Efficiency Spark-Ignition Flames

Modern spark ignition internal combustion engines rely on fast combustion rates and high dilution to achieve high brake thermal efficiencies. To accomplish this, new engine designs have moved towards increased tumble ratios and stroke-to-bore ratios. Increased tumble ratios correlate positively with increases in turbulent kinetic energy and improved fuel and residual gas mixing, all of which favor faster and more efficient combustion. Longer stroke-to-bore ratios allow higher geometric compression ratios and use of late intake valve closing to control peak compression pressures and temperatures. The addition of dilution to improve efficiency is limited by the resulting increase in combustion instabilities manifested by cycle-to-cycle variability. A number of effects - preferential diffusion, turbulence-combustion interactions, stochastic flow patterns, laminar-turbulent flame kernel transitions, and relative length and velocity scales between flame and turbulence - are believed to be responsible for the increase in cycle-to-cycle variations, where their contributions are likely interlinked. Several studies have shown the influence of stochastic flow characteristics on the nature of combustion instabilities, such as velocity patterns on flame kernel formation and cycle-to-cycle variations in residual gas. However, few have focused on the specific effects of fuel properties. The objective of this work is to contrast the effects of dilution on propane stoichiometric combustion against gasoline. Dilution tolerance experiments were conducted in a purpose-built high stroke-to-bore ratio single cylinder engine with both gasoline and LPG. Three-dimensional full cycle computational fluid dynamics (CFD) simulations employing a level-set combustion approach and Reynolds averaged Navier-Stokes (RANS) turbulence modeling was used to qualitatively assess the changes in length and velocity scales for turbulence and the flame. The experimental results showed that LPG can tolerate higher exhaust gas recirculation (EGR) dilution under a variety of conditions. Analysis of CFD simulations showed that propane flames are likely less sensitive to influences from the flow field due to less thickening of the flame and higher effective flame speeds.

33 ADVANCED PROPULSION SYSTEMS↗

Effects of water addition on the combustion of iso -octane investigated in laminar flames, low-temperature reactors, and an HCCI engine

In this work, the effect of H 2 O injection on the combustion process of iso -octane was investigated with the aim to better understand the suitability of water addition as a potential engine control parameter for homogeneous-charge compression ignition (HCCI) combustion. Several experiments were combined including premixed low-pressure flames, a jet-stirred reactor (JSR) and a plug-flow reactor (PFR), both at atmospheric pressure, and a single-cylinder research engine (SCRE) operated with either iso -octane or RON 98 gasoline. The thermal effect of H 2 O addition was determined in laminar premixed iso -octane/O 2 /Ar flames (equivalence ratio $Φ$=1.4, 40 mbar) with H 2 O mole fractions of 0 to 0.22, where water addition reduced the temperature measured by laser-induced fluorescence (LIF) by up to 110 K. Speciation data were obtained from these flames as well as in the JSR ($Φ$=0.65, 933 mbar) and PFR experiments ($Φ$=0.65, 970 mbar) with and without H 2 O addition in the low- to intermediate temperature regime from 700–1100 K. The chemical analysis in these flame and reactor experiments was performed using molecular-beam mass spectrometry (MBMS) employing either electron ionization (EI) in the PFR and premixed flame or single-photon ionization (PI) by tunable vacuum-ultraviolet radiation in the JSR. The effects on species mole fractions were small which is supported by predictions from chemical-kinetic simulations. Quantitative speciation data of the exhaust gas of the SCRE were obtained by using Fourier-transform infrared (FTIR) spectroscopy. A very similar species pool was detected in the laboratory-scale experiments and for the engine operation. It is thus assumed that these results could assist in guiding both the improvement of fundamental chemical-kinetic as well as HCCI engine control models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gasoline Compression Ignition on a Light-Duty Multi-Cylinder Engine Using a Wide Range of Fuel Reactivities and Heavy Fuel Stratification

Many research studies have focused on utilizing gasoline in modern compression ignition engines to reduce emissions and improve efficiency. Collectively, this combustion mode has become kn+own as gasoline compression ignition (GCI). One of the biggest challenges with GCI operation is maintaining control over the combustion process through the fuel injection strategy, such that the engine can be controlled on a cycle-by-cycle basis. Research studies have investigated a wide variety of GCI injection strategies (i.e., fuel stratification levels) to maintain control over the heat release rate while achieving low-temperature combustion (LTC). This work shows that at loads relevant to light-duty engines, partial fuel stratification (PFS) with gasoline provides very little controllability over the timing of combustion. On the contrary, heavy fuel stratification (HFS) provides very linear and pronounced control over the timing of combustion. However, the HFS strategy has challenges achieving LTC operation due to the air handling burdens associated with the high exhaust gas recirculation (EGR) rates that are required to reduce NOx emissions to near zero levels. In this work, a wide variety of gasoline fuel reactivities (octane numbers ranging from <40 to 87) were investigated to understand the engine performance and emissions of HFS-GCI operation on a multi-cylinder light-duty engine. Overall, the results indicate that over an EGR sweep at 4 bar brake mean effective pressure (BMEP), the gasoline fuels can achieve LTC operation with ultra-low NO x and soot emissions, while conventional diesel combustion (CDC) is unable to simultaneously achieve low NO x and soot. At 10 bar BMEP, all the gasoline fuels were compared to diesel, but using mixing controlled combustion and not LTC.

33 ADVANCED PROPULSION SYSTEMS↗

High-Performance Computing and Analysis-Led Development of High Efficiency Dilute Opposed Piston Gasoline Engine

Pinnacle is developing a multicylinder 1.2 L gasoline engine for automotive applications using high-performance computing (HPC) and analysis methods. Pinnacle and Oak Ridge National Laboratory executed large-scale multidimensional combustion analyses at the Oak Ridge Leadership Computing Facility to thoroughly explore the design space. These HPC-led investigations show high fuel efficiency (~46% gross indicated efficiency) may be achieved by operating with extremely high charge dilution levels of exhaust gas recirculation (EGR) at a light load key drive cycle condition (2000 RPM, 3 bar brake mean effective pressure (BMEP)), while simultaneously attaining high levels of fuel conversion efficiency and low NO x emissions. In this extremely dilute environment, the flame propagation event is supported by turbulence and bulk in-cylinder charge motion brought about by modulation of inlet port flow. This arrangement produces a load and speed adjustable amalgamation of swirl and counter-rotating tumble which provides the turbulence required to support stable low-temperature combustion. At higher load conditions, the engine may operate at more traditional combustion modes to generate competitive power. In this work, the numerical results from these HPC simulations are presented. Finally, further HPC simulations and test validations are underway and will be reported in future publications.

42 ENGINEERING↗

Next Gen High Efficiency Boosted Engine Development

This work represents an advanced engineering research project partially funded by the U.S. Department of Energy (DOE). Ford Motor Company, FEV North America, and Oak Ridge National Laboratory collaborated to develop a next generation boosted spark ignited engine concept. The project goals, specified by the DOE, were 23% improved fuel economy and 15% reduced weight relative to a 2015 or newer light-duty vehicle. The fuel economy goal was achieved by designing an engine incorporating high geometric compression ratio, high dilution tolerance, low pumping work, and low friction. The increased tendency for knock with high compression ratio was addressed using early intake valve closing (EIVC), cooled exhaust gas recirculation (EGR), an active pre-chamber ignition system, and careful management of the fresh charge temperature. Engine weight reduction measures were implemented throughout the engine system making use of composite materials, advanced manufacturing techniques, and architectural choices. This report outlines the analytical, design, fabrication, and test work conducted for the duration of the project. The combustion system stability, EGR tolerance, and knock resistance were validated on a single cylinder engine. An inline six-cylinder engine was then designed targeting application in the Ford F150. Multi-cylinder engines were produced and tested achieving the target vehicle fuel economy improvement of 23% assessed using measured engine fuel consumption combined with a vehicle drive cycle simulation. Actions were identified and designs were demonstrated to achieve the 15% weight reduction target. This project included items covering a range of technology readiness levels. Some of the technologies explored are production ready, while others were investigated to understand the limitations for what can be achieved in a stoichiometric, gasoline-fueled, spark-ignited internal combustion engine.

42 ENGINEERING↗

The Reduced Effectiveness of EGR to Mitigate Knock at High Loads in Boosted SI Engines

Numerous studies have demonstrated that exhaust gas recirculation (EGR) can attenuate knock propensity in spark ignition (SI) engines at naturally aspirated or lightly boosted conditions. In this paper, we investigate the role of cooled EGR under higher load conditions with multiple fuel compositions, where highly retarded combustion phasing typical of modern SI engines was used. It was found that under these conditions, EGR attenuation of knock is greatly reduced, where EGR doesn’t allow significant combustion phasing advance as it does under lighter load conditions. Detailed combustion analysis shows that when EGR is added, the polytropic coefficient increases causing the compressive pressure and temperature to increase. At sufficiently highly boosted conditions, the increase in polytropic coefficient and additional trapped mass from EGR can sufficiently reduce fuel ignition delay to overcome knock attenuation effects. Kinetic modeling demonstrates that the effectiveness of EGR to mitigate knock is highly dependent on the pressure-temperature condition. Experiments at 2000 rpm have confirmed reduced fuel ignition delay under highly boosted conditions relevant to modern downsized boosted SI engines, where in-cylinder pressure is higher and the temperature is cooler. Finally, at these conditions, charge reactivity increases compared to naturally aspirated conditions, and attenuation of knock by EGR is reduced.

33 ADVANCED PROPULSION SYSTEMS↗

Geological Sequestration of CO2 by Hydrous Carbonate Formation with Reclaimed Slag

The concept of this project is to develop a process that improves the kinetics of the hydrous carbonate formation reaction enabling steelmakers to directly remove CO2 from their furnace exhaust gas. It is proposed to bring the furnace exhaust stream containing CO2 in contact with reclaimed steelmaking slag in a reactor that has an environment near the unit activity of water resulting in the production of carbonates. The CO2 emissions from the plant would be reduced by the amount sequestered in the formation of carbonates. The main raw materials for the process are furnace exhaust gases and specially prepared slag.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗