Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ESS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Final Report: Archiving Data to Support Data Synthesis of DOE Sponsored Elevated CO 2 Experiments

Over the last three decades DOE made a large investment in field-scale experiments in order to understand the role of terrestrial ecosystems in the global carbon cycle, and forecast how carbon cycling will change over the next century. The Smithsonian Environmental Research Center received one of the first awards in this program and managed two long-term studies (25 years and 10 years) with a total of approximately $10 million of support from DOE, and many more millions leveraged from the Smithsonian Institution and agencies such as NSF. The present DOE grant was based on the premise that such a large investment demands a proper synthesis effort so that the full potential of these experiments are realized through data analysis and modeling. The goal of the this grant was to archive legacy data from two major elevated carbon dioxide experiments in DOE databases, and to engage in synthesis activities using these data. Both goals were met. All datasets deemed a high priority for data synthesis and modeling were prepared for archiving and analysis. Many of these datasets were deposited in DOE’s CDIAC, while others are being held at the Oak Ridge National Lab and the Smithsonian Institution until they can be received by DOE’s new ESS-DIVE system at Berkeley Lab. Most of the effort was invested in researching and re-constituting high-quality data sets from a 30-year elevated CO 2 experiment. Using these data, the grant produced products that are already benefiting climate change science, including the publication of new coastal wetland allometry equations based on 9,771 observations, public posting of dozens of datasets, metadata and supporting codes from long-term experiments at the Global Change Research Wetland, and publication of two synthetic data papers on scrub oak forest responses to elevated CO 2 . In addition, three papers are in review or nearing submission reporting unexpected long-term patterns in ecosystem responses to elevated CO 2 and nitrogen in a coastal wetland.

54 ENVIRONMENTAL SCIENCES↗

Safety Outreach and Incident Response Stakeholder Strategy

The objective of this document is to set out a strategy to reach all stakeholders that can impact the timely deployment of safe stationary energy storage systems in the built environment with information on ESS technology and safety that is relevant to their role in deployment of the technology.

25 ENERGY STORAGE↗

DOE OE Energy Storage Systems Safety Roadmap Focus on Proposed Changes to the ICC International Codes Special Briefing Paper — Unofficial Hearing Results April 2018

The goal of the DOE OE ESS Safety Roadmap1 is to foster confidence in the safety and reliability of energy storage systems (ESSs). Three interrelated objectives support the realization of that goal: research, codes and standards, and communication/coordination. The objective focused on codes and standards is - To apply research and development (R&D) to support efforts that are focused on ensuring that codes and standards are available to enable the safe implementation of ESSs in a comprehensive, non-discriminatory and science-based manner. The purpose of this special briefing paper is to support the above objective by providing information about current and upcoming efforts being conducted by U.S. standards developing organizations, specifically code changes associated with the 2018 Group A International Codes (I-Codes) of the International Code Council (ICC) that are relevant to ESSs.

25 ENERGY STORAGE↗

Energy Storage Data Submission Guidelines

In order to consider and understand emerging energy storage technologies, data analysis can be executed to ascertain proper operation and performance. The technical benefits of rigorous testing and data analysis are important for the customer, the planner, developer, and system operator: the end-user has a safe, reliable system that performs predictably on a macro level. The test-and-analyze approach to verifying performance of energy storage devices, equipment, and systems integration into the grid improves the understanding of the value of energy storage over time from the economic vantage point. Demonstrating the lifecycle value of energy storage begins with the data the provider supplies for analysis. After review of energy storage data received from several providers, it has become clear that some ESS data is inconsistent and incomplete - thus leading to a question of the inefficacy of the data when it comes time to analyze it. This paper will review and propose general guidelines such as sampling rates and data points that providers must supply in order for robust data analysis to take place. Consistent guidelines are the basis of the proper protocol to (a) reduce time it takes data to reach those who are providing analyses; (b) allow them to better understand the energy storage installations; and (c) provide high quality analysis of the installation. This paper intends to serve as a starting point for what data points should be provided when monitoring. As battery technologies continue to advance and the industry expands, this paper will be updated to remain current.

25 ENERGY STORAGE↗

Energy Storage System Guide for Compliance with Safety Codes and Standards

Codes, standards and regulations (CSR) governing the design, construction, installation, commissioning and operation of the built environment are intended to protect the public health, safety and welfare. While these documents change over time to address new technology and new safety challenges there is generally some lag time between the introduction of a technology into the market and the time it is specifically covered in model codes and standards developed in the voluntary sector. After their development, there is also a timeframe of at least a year or two until they are adopted. Until existing model codes and standards are updated or new ones developed and then adopted, one seeking to deploy energy storage technologies or needing to verify an installation’s safety may be challenged in applying current CSRs to an energy storage system (ESS).

25 ENERGY STORAGE↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pressurizing Hagan and SAVY containers to 30-psig (air) to measure the release of analytical cerium oxide test powder

In response to an ESS surrounding the storage of sealed sources at TA-55, personnel from RP-SVS (Radiation Protection Services) and ORI-2 (Operational Readiness & Execution) were approached by ES-55 (Facility System Engineering) to provide technical testing of known nuclear material storage containers. Testing criteria were determined by SB-PF (Safety Basis for Plutonium Facilities). Tests were conducted in conjunction with multiple related projects at the Aerosol Sciences Laboratory (TA-03-0130-0103). An experimental system was quickly developed to deliver a pressure pulse (30-psig) that mimics a sealed source burst scenario. A series of twelve tests was conducted. Six tests were done with two different 5QT SAVY-4000 containers, where each SAVY filter-lid combination was subjected to three successive test insults. Three tests were done with a (0.375" diameter filter) 8Q.T Hagan container, and three tests with a (0.625" diameter filter) 8QT Hagan container. An unused, fresh container filter was used for each tested Hagan container, each receiving only one test insult per filter. Cerium oxide (CeO 2 ) powder was loaded (100 grams per test) into a nozzle in the tested Hagan and SAVY containers, and the nozzle was hard-plumbed to a ball valve and a pressure source. This system was installed into the Los Alamos RRFMC (Respirable Release Measurement Chamber), which is an integrated multipurpose aerosol wind tunnel that satisfies NQA-1 subpart 2.4 for R&D work. The ball valve was fitted with a mechanical linkage for operation from outside the wind tunnel. An aerodynamic particle sizer counted the particle concentrations and size distributions of released aerosol. Respirable aerosol released during the tests was measured and a correction factor for wind tunnel flowrate and internal duct deposition was applied.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cyber Security Primer for DER Vendors Aggregators and Grid Operators

This report provides an introduction to cyber security for distributed energy resources (DER) - such as photovoltaic (PV) inverters and energy storage systems (ESS). This material is motivated by the need to assist DER vendors, aggregators, grid operators, and broader PV industry with cyber security resilience and describe the state-of-the-art for securing DER communications. The report outlines basic principles of cyber security, encryption, communication protocols, DER cyber security recommendations and requirements, and device-, aggregator-, and utility-level security best practices to ensure data confidentiality, integrity, and availability. Example cyber security attacks, including eavesdropping, masquerading, man-in-the-middle, replay attacks, and denial-of-service are also described. A survey of communication protocols and cyber security recommendations used by the DER and power system industry are included to elucidate the cyber security standards landscape. Lastly, a roadmap is presented to harden end-to-end communications for DER with research and industry engagement.

24 POWER TRANSMISSION AND DISTRIBUTION↗