Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRONIC MODULE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

High efficiency compact microwave sources using electrostatic potential depression

In this article, we report theoretical and design studies on the application of an electrostatic potential depression (EPD) on two types of traditional microwave sources, the klystron and the inductive output tube (IOT), both operating in the UHF band. Additionally, the EPD is implemented by a section of the metallic beam pipe on which a direct current (dc) negative high voltage is applied. Inside the EPD section, the modulated electron beam develops into bunches over a very short longitudinal distance, indicating a possible design approach for a compact device. With the application of an EPD, the peak value of the first harmonic current in a microwave tube can be further increased compared to that in a conventional design, suggesting higher circuit efficiency. As the electron beam leaves the EPD section, the reacceleration of the beam provides a longitudinal cooling effect. With the addition of an EPD, circuit power extraction efficiency above 80% is achieved in both the modified design of the IOT and the novel conceptual circuit design of the klystron.

42 ENGINEERING↗

Network Time Synchronization of the Readout Electronics for a New Radioactive Gas Detection System

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors exceeds the readout channels in a single data acquisition electronics module, multiple modules have to be synchronized, which is traditionally accomplished by distributing clocks and triggers via dedicated connections. To eliminate this added cabling complexity in the case of a new radioactive gas detection system prototype under development at the French Atomic Energy Commission, we implemented time synchronization between multiple XIA Pixie-Net detector readout modules through the existing Ethernet network, based on the IEEE 1588 precision time protocol. The detector system is dedicated to the measurement of radioactive gases at low activity and consists of eight large silicon pixels and two NaI(Tl) detectors, instrumented with a total of three 4-channel Pixie-Net modules. Detecting NaI(Tl)/silicon coincidences will make it possible to identify each radioisotope present in the sample. To allow these identifications at low activities, the Pixie-Net modules must be synchronized to a precision well below the targeted coincidence window of 500-1000 ns. Being equipped with an Ethernet PHY compatible with IEEE 1588 and synchronous Ethernet that outputs a locally generated but system-wide synchronized clock, the Pixie-Net can operate its analog to digital converters and digital processing circuitry with that clock and match time stamps for captured data across the three modules. Depending on the network configuration and synchronization method, the implementation is capable to achieve timing precisions between 300 ns and 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of quantum key distribution and quantum clock synchronization via time bin encoding

Quantum key distribution allows for a provably secure transmission of cryptographic keys over an optical channel. Encoded polarization states or time-bin degree of freedom have been used for successful demonstrations. However, photon losses in long fibers, slow single photon detectors, and detector dark counts significantly limit the overall bit rate. Improving key throughput and reducing the overhead of key reconciliation remain as major challenges. Methods which utilize multiple time bins allow for multiple key bits to be encoded in a single photon, thus increasing the fidelity of transmitted keys and decreasing the overhead of key reconciliation in real-world conditions. Previous implementations of these methods required that Alice and Bob share a time reference by sharing a dedicated classical channel used for synchronization. This work presents a technique that allows two parties to exchange time-bin encoded photons without the need for synchronized time references. Our technique uses a framing protocol which allows Alice to encode a time reference along with a key which is determined by Alice before transmission. Security can be achieved by monitoring the visibility of a pair of Franson interferometers, using decoy pulses and measuring the round trip time between Alice and Bob. The bit rate of this technique is limited only by the recovery time of the detector and the speed of the modulation electronics. We experimentally demonstrate a raw bit rate of 5Mb/s over an optical channel with 55dB of loss, which is competitive with current research. We also demonstrate absolute timing synchronization with an accuracy of 20ps.

encryption↗

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-595: Design of a Graphical User Interface for An In-House Monte Carlo Based Treatment Planning System: Planning and Contouring Tools

Purpose: An in-house Monte Carlo based treatment planning system (MC TPS) has been developed for modulated electron radiation therapy (MERT). Our preliminary MERT planning experience called for a more user friendly graphical user interface. The current work aimed to design graphical windows and tools to facilitate the contouring and planning process. Methods: Our In-house GUI MC TPS is built on a set of EGS4 user codes namely MCPLAN and MCBEAM in addition to an in-house optimization code, which was named as MCOPTIM. Patient virtual phantom is constructed using the tomographic images in DICOM format exported from clinical treatment planning systems (TPS). Treatment target volumes and critical structures were usually contoured on clinical TPS and then sent as a structure set file. In our GUI program we developed a visualization tool to allow the planner to visualize the DICOM images and delineate the various structures. We implemented an option in our code for automatic contouring of the patient body and lungs. We also created an interface window displaying a three dimensional representation of the target and also showing a graphical representation of the treatment beams. Results: The new GUI features helped streamline the planning process. The implemented contouring option eliminated the need for performing this step on clinical TPS. The auto detection option for contouring the outer patient body and lungs was tested on patient CTs and it was shown to be accurate as compared to that of clinical TPS. The three dimensional representation of the target and the beams allows better selection of the gantry, collimator and couch angles. Conclusion: An in-house GUI program has been developed for more efficient MERT planning. The application of aiding tools implemented in the program is time saving and gives better control of the planning process.

60 APPLIED LIFE SCIENCES↗

MCTP system model based on linear programming optimization of apertures obtained from sequencing patient image data maps

Purpose: The authors present a hybrid direct multileaf collimator (MLC) aperture optimization model exclusively based on sequencing of patient imaging data to be implemented on a Monte Carlo treatment planning system (MC-TPS) to allow the explicit radiation transport simulation of advanced radiotherapy treatments with optimal results in efficient times for clinical practice. Methods: The planning system (called CARMEN) is a full MC-TPS, controlled through aMATLAB interface, which is based on the sequencing of a novel map, called “biophysical” map, which is generated from enhanced image data of patients to achieve a set of segments actually deliverable. In order to reduce the required computation time, the conventional fluence map has been replaced by the biophysical map which is sequenced to provide direct apertures that will later be weighted by means of an optimization algorithm based on linear programming. A ray-casting algorithm throughout the patient CT assembles information about the found structures, the mass thickness crossed, as well as PET values. Data are recorded to generate a biophysical map for each gantry angle. These maps are the input files for a home-made sequencer developed to take into account the interactions of photons and electrons with the MLC. For each linac (Axesse of Elekta and Primus of Siemens) and energy beam studied (6, 9, 12, 15 MeV and 6 MV), phase space files were simulated with the EGSnrc/BEAMnrc code. The dose calculation in patient was carried out with the BEAMDOSE code. This code is a modified version of EGSnrc/DOSXYZnrc able to calculate the beamlet dose in order to combine them with different weights during the optimization process. Results: Three complex radiotherapy treatments were selected to check the reliability of CARMEN in situations where the MC calculation can offer an added value: A head-and-neck case (Case I) with three targets delineated on PET/CT images and a demanding dose-escalation; a partial breast irradiation case (Case II) solved with photon and electron modulated beams (IMRT + MERT); and a prostatic bed case (Case III) with a pronounced concave-shaped PTV by using volumetric modulated arc therapy. In the three cases, the required target prescription doses and constraints on organs at risk were fulfilled in a short enough time to allow routine clinical implementation. The quality assurance protocol followed to check CARMEN system showed a high agreement with the experimental measurements. Conclusions: A Monte Carlo treatment planning model exclusively based on maps performed from patient imaging data has been presented. The sequencing of these maps allows obtaining deliverable apertures which are weighted for modulation under a linear programming formulation. The model is able to solve complex radiotherapy treatments with high accuracy in an efficient computation time.

60 APPLIED LIFE SCIENCES↗

Beamlet based direct aperture optimization for MERT using a photon MLC

Purpose: A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. Methods: The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose–volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. Results: For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. Conclusions: A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

60 APPLIED LIFE SCIENCES↗

Atomically thin layers of B–N–C–O with tunable composition

In recent times, atomically thin alloys of boron, nitrogen, and carbon have generated significant excitement as a composition-tunable two-dimensional (2D) material that demonstrates rich physics as well as application potentials. The possibility of tunably incorporating oxygen, a group VI element, into the honeycomb sp 2 -type 2D-BNC lattice is an intriguing idea from both fundamental and applied perspectives. We present the first report on an atomically thin quaternary alloy of boron, nitrogen, carbon, and oxygen (2D-BNCO). Our experiments suggest, and density functional theory (DFT) calculations corroborate, stable configurations of a honeycomb 2D-BNCO lattice. We observe micrometer-scale 2D-BNCO domains within a graphene-rich 2D-BNC matrix, and are able to control the area coverage and relative composition of these domains by varying the oxygen content in the growth setup. Macroscopic samples comprising 2D-BNCO domains in a graphene-rich 2D-BNC matrix show graphene-like gate-modulated electronic transport with mobility exceeding 500 cm 2 V -1 s -1 , and Arrhenius-like activated temperature dependence. Spin-polarized DFT calculations for nanoscale 2D-BNCO patches predict magnetic ground states originating from the B atoms closest to the O atoms and sizable (0.6 eV < E g < 0.8 eV) band gaps in their density of states. These results suggest that 2D-BNCO with novel electronic and magnetic properties have great potential for nanoelectronics and spintronic applications in an atomically thin platform.

36 MATERIALS SCIENCE↗

Moiré excitons: From programmable quantum emitter arrays to spin-orbit–coupled artificial lattices

Highly uniform and ordered nanodot arrays are crucial for high-performance quantum optoelectronics, including new semiconductor lasers and single-photon emitters, and for synthesizing artificial lattices of interacting quasiparticles toward quantum information processing and simulation of many-body physics. Van der Waals heterostructures of two-dimensional semiconductors are naturally endowed with an ordered nanoscale landscape, that is, the moiré pattern that laterally modulates electronic and topographic structures. We find that these moiré effects realize superstructures of nanodot confinements for long-lived interlayer excitons, which can be either electrically or strain tuned from perfect arrays of quantum emitters to excitonic superlattices with giant spin-orbit coupling (SOC). Besides the wide-range tuning of emission wavelength, the electric field can also invert the spin optical selection rule of the emitter arrays. This unprecedented control arises from the gauge structure imprinted on exciton wave functions by the moiré, which underlies the SOC when hopping couples nanodots into superlattices. We show that the moiré hosts complex hopping honeycomb superlattices, where exciton bands feature a Dirac node and two Weyl nodes, connected by spin-momentum–locked topological edge modes.

36 MATERIALS SCIENCE↗

Improved Hydrogen Sensitivity and Selectivity in PdO with Metal-Organic Framework Membrane

Metal-organic frameworks (MOFs) are highly designable porous materials and are recognized for their exceptional selectivity as chemical sensors. However, they are not always suitable for incorporation with existing sensing platforms, especially sensing modes that rely on electronic changes in the sensing material (e.g., work-function response or conductometric response). One way that MOFs can be utilized is by growing them as a porous membrane on a sensing layer and using the MOF to affect the electronic structure of the sensing layer. In this paper, a proof-of-concept for electronic modulation with MOFs is demonstrated. A PdO nanoparticle sensing layer on a chemical-sensitive field-effect-transistor is made more sensitive to a reducing gas, hydrogen, and less sensitive to oxidizng molecules, like H 2 S and NO 2 , by growing a layer of the MOF “ZIF-8” over the nanoparticles. The proposed mechanism is supported by X-ray photoelectron spectroscopy showing that the ZIF-8 membrane partially reduces the PdO sensing layer.

Gardner, David W. (ORCID:0000000193518391)↗

A Process and Environment Aware Sierra/SolidMechanics Cohesive Zone Modeling Capability for Polymer/Solid Interfaces

The performance and reliability of many mechanical and electrical components depend on the integrity of polymer-to-solid interfaces. Such interfaces are found in adhesively bonded joints, encapsulated or underfilled electronic modules, protective coatings, and laminates. The work described herein was aimed at improving Sandia’s finite element–based capability to predict interfacial crack growth by 1) using a high fidelity nonlinear viscoelastic material model for the adhesive in fracture simulations, and 2) developing and implementing a novel cohesive zone fracture model that generates a mode-mixity dependent toughness as a natural consequence of its formulation (i.e., generates the observed increase in interfacial toughness with increasing crack-tip interfacial shear). Furthermore, molecular dynamics simulations were used to study fundamental material/interfacial physics so as to develop a fuller understanding of the connection between molecular structure and failure. Also reported are test results that quantify how joint strength and interfacial toughness vary with temperature.

36 MATERIALS SCIENCE↗

Novel Low-Temperature Plasma Reactor for Industrial Applications

UV water disinfection for municipalities around the world is expected to grow over 15% annually, leading to a $2.8 billion dollar market by 2020. This growth is driving the need for higher power and more efficient UV sources. By far the greatest potential market for UV disinfection is drinking water. UV is now accepted as an available technology to deactivate Cryptosporidium and Giardia in surface water and other vulnerable sources. The output power of typical mercury-vapor UV lamps is limited to 30 W/m, requiring large arrays to treat relevant volumes of water. Higher power sources can be built with low-temperature plasmas, but require large, lossy, light-blocking magnetic cores. These cores require extensive cooling, and place a hard ceiling on power transfer to the plasma, optical efficiency, and ultimately on radiant light flux. In Phase I of this SBIR, DTI developed a novel, magnetically-coupled, toroidal pulsed plasma reactor that could run without ferrite cores, though the cores increased the coupling. DTI’s proposed geometry and exciter circuit topology enables the use of comparatively inexpensive electronic modules to operate in a pulsed-RF mode. The pulsed high-power discharge (1.5 MW peak, 500 kHz, < 5% duty cycle) creates high plasma temperatures for short durations, while maintaining a much lower steady-state temperature. This proposed reactor will be designed primarily to disinfect and denature wastewater or drinking water products, exploiting large-scale UV disinfection techniques. The UVC efficiency with the highest output power was 6.2%; for comparison, the efficiency of present high-power UV sources is 13%. It may be possible to increase the efficiency by operating pulses in a burst mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Storage Ring Current Monitor

The storage ring current monitor is expected to be utilized for the following functions: measurement of the current circulating in the storage ring; measurement of the beam lifetime; measurement of the injection efficiency; provide the level of the circulating current for the equipment protection system; provide amount of charge required for the next injection cycle in the top-up mode operation. The current will be monitored with a parametric current transformer (DCCT) integrated into the vacuum system of the storage ring. The electronic module will convert the current reading into the corresponding voltage which will be measured with a digital voltmeter (DVM). The digitized data will be processed by the control system.

43 PARTICLE ACCELERATORS↗

Radio Frequency Field Programable Gate Array Implementation of Reflectometry Cable Monitoring

This document describes the development of a field programable gate array (FPGA) radio frequency system on a chip (RF SoC) adaptation and evaluation of the single-board device to perform both Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR) for offline and online cable testing. The work builds on and leverages the work of Pacific Northwest National Laboratory (PNNL) in airport millimeter wave technology by using the same development hardware employed in that program. The work is performed under sponsorship from the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program and the task objective is to confirm and demonstrate feasibility to adapt FPGA technology for a cost-effective multiplexed single-board electronic module to perform cable tests that are equivalent to commercial and laboratory test instruments for FDR and SSTDR cable tests. The developed 2-channel (extendable to 7 channels) system was compared to dedicated and proven test instruments and shown to produce equivalent results on a range of cables and with a range of damage types. The FPGA reflectometry test board is one of several technologies that could facilitate implementation of online monitoring of safety critical cable systems.

42 ENGINEERING↗

Transistor current and voltage limiting switch

Limiting circuit protects the main power supply of electronic modules and limits the current drawn by each module should a short circuit occur. It limits current within one mA when used with direct current of either polarity, or with pulse or ac power sources from direct current to 100 kHz.

Hilbert, E. E.↗