Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRON MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Electric field stimulation setup for photoemission electron microscopes

Manipulating magnetisation by the application of an electric field in magnetoelectric multiferroics represents a timely issue due to the potential applications in low power electronics and the novel physics involved. Thanks to its element sensitivity and high spatial resolution, X-ray photoemission electron microscopy is a uniquely suited technique for the investigation of magnetoelectric coupling in multiferroic materials. In this work, we present a setup that allows for the application of in situ electric and magnetic fields while the sample is analysed in the microscope. As an example of the performances of the setup, we present measurements on Ni/Pb(Mg{sub 0.66}Nb{sub 0.33})O{sub 3}-PbTiO{sub 3} and La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/PMN-PT artificial multiferroic nanostructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flexible high-voltage supply for experimental electron microscope

Scanning microscope uses a field-emission tip for the electron source, an electron gun that simultaneously accelerates and focuses electrons from the source, and one auxiliary lens to produce a final probe size at the specimen on the order of angstroms.

Chapman, G. L.↗

The determination of transport parameters of minority carriers in n-p junctions by means of an electron microscope - Critique of recent developments

It has recently been shown that amplitude modulated electron beams provide a novel means for the determination of minority carrier lifetimes, diffusion lengths, etc., in n-p junctions. In this paper it is shown that: (1) a recently published analysis based on a cylindrically symmetric configuration is incorrect, (2) the correct approach leads to a system of dual integral equations for which the formal solution is given, (3) in general, the short circuit current can only be determined by means of extensive computer calculations except in the case of large front surface recombination velocities, and (4) the difficulties encountered with cylindrically symmetric configurations (circular ohmic contacts and the like) are completely avoided with a choice of a planar geometry since simple closed form expressions for the short circuit current are readily available in this case.

Von Roos, O.↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

A novel low energy electron microscope for DNA sequencing and surface analysis

Monochromatic, aberration-corrected, dual-beam low energy electron microscopy (MAD-LEEM) is a novel technique that is directed towards imaging nanostructures and surfaces with sub-nanometer resolution. The technique combines a monochromator, a mirror aberration corrector, an energy filter, and dual beam illumination in a single instrument. The monochromator reduces the energy spread of the illuminating electron beam, which significantly improves spectroscopic and spatial resolution. Simulation results predict that the novel aberration corrector design will eliminate the second rank chromatic and third and fifth order spherical aberrations, thereby improving the resolution into the sub-nanometer regime at landing energies as low as one hundred electron-Volts. The energy filter produces a beam that can extract detailed information about the chemical composition and local electronic states of non-periodic objects such as nanoparticles, interfaces, defects, and macromolecules. The dual flood illumination eliminates charging effects that are generated when a conventional LEEM is used to image insulating specimens. A potential application for MAD-LEEM is in DNA sequencing, which requires high resolution to distinguish the individual bases and high speed to reduce the cost. The MAD-LEEM approach images the DNA with low electron impact energies, which provides nucleobase contrast mechanisms without organometallic labels. Furthermore, the micron-size field of view when combined with imaging on the fly provides long read lengths, thereby reducing the demand on assembling the sequence. Finally, experimental results from bulk specimens with immobilized single-base oligonucleotides demonstrate that base specific contrast is available with reflected, photo-emitted, and Auger electrons. Image contrast simulations of model rectangular features mimicking the individual nucleotides in a DNA strand have been developed to translate measurements of contrast on bulk DNA to the detectability of individual DNA bases in a sequence.

47 OTHER INSTRUMENTATION↗

Transmission electron microscope cells for use with liquid samples

This disclosure provides systems, methods, and devices related to transmission electron microscopy cells for use with liquids. In one aspect a device includes a substrate, a first graphene layer, and a second graphene layer. The substrate has a first surface and a second surface. The first surface defines a first channel, a second channel, and an outlet channel. The first channel and the second channel are joined to the outlet channel. The outlet channel defines a viewport region forming a though hole in the substrate. The first graphene layer overlays the first surface of the substrate, including an interior area of the first channel, the second channel, and the outlet channel. The second graphene layer overlays the first surface of the substrate, including open regions defined by the first channel, the second channel, and the outlet channel.

36 MATERIALS SCIENCE↗

Advanced electron microscopic techniques applied to the characterization of irradiation effects and fission product identification of irradiated TRISO coated particles from the AGR-1 experiment

Preliminary electron microscopy of coated fuel particles from the AGR-1 experiment was conducted using characterization techniques such as scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and wavelength dispersive spectroscopy (WDS). Microscopic quantification of fission-product precipitates was performed. Although numerous micro- and nano-sized precipitates observed in the coating layers during initial SEM characterization of the cross-sections, and in subsequent TEM diffraction patterns, were indexed as UPd{sub 2}Si{sub 2}, no Ag was conclusively found. Additionally, characterization of these precipitates highlighted the difficulty of measuring low concentrations of Ag in precipitates in the presence of significantly higher concentrations of Pd and U. The electron microscopy team followed a multi-directional and phased approach in the identification of fission products in irradiated TRISO fuel. The advanced electron microscopy techniques discussed in this paper, not only demonstrate the usefulness of the equipment (methods) as relevant research tools, but also provide relevant scientific results which increase the knowledge about TRISO fuel particles microstructure and fission products transport.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Note: A scanning electron microscope sample holder for bidirectional characterization of atomic force microscope probe tips

A novel sample holder that enables atomic force microscopy (AFM) tips to be mounted inside a scanning electron microscopy (SEM) for the purpose of characterizing the AFM tips is described. The holder provides quick and easy handling of tips by using a spring clip to hold them in place. The holder can accommodate two tips simultaneously in two perpendicular orientations, allowing both top and side view imaging of the tips by the SEM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron microscopic investigation of crystal lattice bending-torsion and internal stresses in deformed polycrystalline alloys

Generalization of the results of electron microscopy investigations of the crystal lattice bending-torsion (χ) and the internal stresses (IS) was conducted. The deformed polycrystalline alloys and steels were investigated. The sources of χ and IS origin were established. The regularities of their change with the distance from the sources and the evolution with deformation were revealed. The contribution of IS into the deformation resistance was determined. The nature of formation of two sequences of dislocation substructure transformations during deformation of alloys was established.

36 MATERIALS SCIENCE↗

Sodium reconstruction on surface of silicate glasses in transmission electron microscope

We find that irradiated Na ions in silicate glasses undergo reconstruction on the surfaces before being repelled from the irradiated area by electron excitations. These results are based on evidence from time-dependent electron energy-loss spectroscopy. The process of reconstruction involves an irreversible change of the Na{sup +}{yields}Na{sup 0}{yields}Na{sup +}, in which the initial and final Na{sup +} ions have different bonding environments. The phenomenon is the result of the elimination of nonbridging oxygen associated with Na.

36 MATERIALS SCIENCE↗

Production of otoconia in the endolymphatic sac in the Japanese red-bellied newt, Cynops pyrrhogaster: light and transmission electron microscopic study

The formation of otoconia in the endolymphatic sac (ES) of the larval newt, Cynops pyrrhogaster, has been studied by light and transmission electron microscopy. Some of the epithelial cells of the ES contain an abundance of swollen vesicles, Golgi complexes, rough endoplasmic reticula and ribosomes at the late larval stages 50 and 51, approximately 26-30 days after eggs are laid. Five days later, at stage 52, crystals are present in the vacuoles between the epithelial cells. Serial sections indicate that these vacuoles actually form small canals which lie in the wall and join the lumen of the ES. Reconstruction of the ES shows that several canals are contained in the ES wall. At stage 56, about 72 days after eggs are laid, a large number of otoconia are present in the ES lumen, while the otoconia disappear from the canals. It appears that the otoconia are first produced in the canals and then released to the lumen. Some epithelial cells of the ES are thought to expel the organic and inorganic material to the canals to form the otoconia in situ. The process of formation of the otoconia in the ES is discussed.

Non-NASA Center↗

Subcellular localization of leptin and leptin receptor in breast cancer detected in an electron microscopic study

Leptin (LEP) and leptin receptor (LEPR) have long been found associated with breast cancer. So far no high-resolution method such as electron microscopy has been used to investigate the subcellular localization of leptin and leptin receptor in breast cancer. We collected cancer and non-cancer breast tissues from 51 women with invasive ductal breast cancer. Leptin and leptin receptor in the tissues were estimated using immunohistochemistry (IHC). LEP and LEPR were localized at subcellular level by immunocytochemistry (ICC) using ultra-fine gold particle conjugated antibody, and visualized with transmission electron microscopy (TEM). IHC showed high presence of LEP and LEPR in 65% and 67% respectively of the breast cancer samples, 100% and 0% respectively of the adipose tissue samples, and no high presence in the non-cancer breast tissue samples. On TEM views both LEP and LEPR were found highly concentrated within the nucleus of the cancer cells, indicating that nucleus is the principal seat of action. However, presence of high concentration of LEP does not necessarily prove its over-expression, as often concluded, because LEP could be internalized from outside by LEPR in the cells. In contrast, LEPR is definitely over-expressed in the ductal breast cancer cells. Therefore, we hypothesize that over-expression of LEPR, rather than that of LEP has a fundamental role in breast carcinogenesis in particular, and probably for LEP-LEPR associated tumors in general. - Highlights: • Leptin-leptin receptor complex is localized mostly in and around the nucleus. • Nucleus might be the final seat of action of leptin-leptin receptor complex. • Immunohistochemistry can prove over-expression of leptin receptor, not of leptin. • Over-expression of leptin receptor is of primary importance in breast cancer.

60 APPLIED LIFE SCIENCES↗

High-resolution analogue of time-domain phonon spectroscopy in the transmission electron microscope

Femtosecond photoexcitation of semiconducting materials leads to the generation of coherent acoustic phonons (CAPs), the behaviours of which are linked to intrinsic and engineered electronic, optical and structural properties. While often studied with pump-probe spectroscopic techniques, the influence of nanoscale structure and morphology on CAP dynamics can be challenging to resolve with these all-optical methods. Here, we used ultrafast electron microscopy (UEM) to resolve variations in CAP dynamics caused by differences in the degree of crystallinity in as-prepared and annealed GaAs lamellae. Following in situ femtosecond photoexcitation, we directly imaged the generation and propagation dynamics of hypersonic CAPs in a mostly amorphous and, following an in situ photothermal anneal, a mostly crystalline lamella. Subtle differences in both the initial hypersonic velocities and the asymptotic relaxation behaviours were resolved via construction of space-time contour plots from phonon wavefronts. Comparison to bulk sound velocities in crystalline and amorphous GaAs reveals the influence of the mixed amorphous-crystalline morphology on CAP dispersion behaviours. Further, an increase in the asymptotic velocity following annealing establishes the sensitivity of quantitative UEM imaging to both structural and compositional variations through differences in bonding and elasticity. Lastly, implications of extending the methods and results reported here to elucidating correlated electronic, optical and structural behaviours in semiconducting materials are discussed.

42 ENGINEERING↗

Combined infrared and analytical electron microscope studies of interplanetary dust particles

Ultramicrotomed thin sections (less than 100 nm thick) of eight chondritic interplanetary dust particles (IDPs) were studied by analytical electron microscopy and IR microspectroscopy with the objective of identifying IDPs or their specific components with IR spectral transmission characteristics at 10 microns similar to those of comets. Two IDPs are identified whose silicate emission characteristics between 8 and 12 microns are similar to those of comets Halley and Bradfield. Implanted solar flare tracks and sputtered rims resulting from solar wind damage suggest that the minerology and petrography of these IDPs have not been significantly perturbed since ejection from their parent bodies.

Bradley, J. P.↗

Analytical Formulae for Calculation of X-Ray Detector Solid Angles in the Scanning and Scanning/Transmission Analytical Electron Microscope

Closed form analytical equations used to calculate the collection solid angle of six common geometries of solid-state X-ray detectors in scanning and scanning/transmission analytical electron microscopy are presented. Using these formulae one can make realistic comparisons of the merits of the different detector geometries in modern electron column instruments. This work updates earlier formulations and adds new detector configurations.

Zaluzec, Nestor J.↗

Three-dimensional structure investigation of Waterborne Paint by Electron Microscopic Imaging

In this paper, the three-dimensional (3D) spatial structure of a TiO 2 coated waterborne paint film has been successfully investigated by serial block-face scanning electron microscopy (SBFSEM). The investigation clearly shows the spatial distribution of the TiO2 particles in the paint film and illustrates the degree of dispersion of the particles in the composite material. More than 58% of the volume of the TiO 2 particles are between 1.0 × 10 6 nm 3 to 1.0 × 10 7 nm 3 and the minimum distance between different particles can be detected is 124 nm. Different types of voids can be found in the 3D image of the cured water-borne paint film: voids that exist in the paint itself, voids produced by particle shedding, water evaporating and particles stacking. Among these voids, the ones produced by particle shedding is a cutting artefact. The research provides a different approach to clearly present the 3D spatial structure of paints and can clearly illustrate different kinds of voids inside the water-borne paint. While the resulting 3D structure of the paint, especially the different voids are important for further systematic research on the relationships between the spatial microstructure and the physical and chemical properties of the water-borne paint.

36 MATERIALS SCIENCE↗