Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Direct Detection of Soil mRNAs using Targeted Microarrays for Genes Associated with Lignin Degradation

Microarrays have become established tools for describing microbial systems, however the assessment of expression profiles for environmental microbial communities still presents unique challenges. Notably, the concentration of particular transcripts are likely very dilute relative to the pool of total RNA, and PCR-based amplification strategies are vulnerable to amplification biases and the appropriate primer selection. Thus, we apply a signal amplification approach, rather than template amplification, to analyze the expression of genes encoding selected lignin-degrading enzymes in soil. Controls in the form of known amplicons and cDNA from Phanerochaete chrysosporium were included and mixed with the soil cDNA both before and after the signal amplification in order to assess the dynamic range of the microarray. We demonstrate that restored prairie soil expresses a diverse range of genes encoding lignin-degrading enzymes following incubation with lignin substrate, while farmed agricultural soil does not. The mixed additions of control cDNA with soil cDNA does interfere with detection of the low abundance transcripts, nevertheless this microarray approach consistently reports the higher-abundance transcripts which present more robust signals.

09 BIOMASS FUELS↗

Sub-Ångström-resolution MicroED Using a Direct Detection Camera

The recent development of microcrystal electron diffraction (MicroED) in electron cryo-microscopy (cryo-EM) has addressed many of the challenges of X-ray crystallography [1], filling a long-standing need in organic chemistry for rapid and accurate high-resolution structural characterization [2]. Like X-ray crystallography, this is also a diffraction technique requiring crystalline specimens, but because high energy electrons have a more favorable ration of elastic to inelastic scattering [3], MicroED can acquire data using crystals that are orders of magnitude smaller than those needed for X-ray crystallography—even as small as 50 nm in length [4]. Additionally, the instrumentation required for MicroED is readily available, as many chemistry and biology labs already have access to cryo-capable transmission electron microscopes (TEM).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Thenardite on the Direct Detection of Aromatic Amino Acids: Implications for the Search for Life in the Solar System

With the discovery of Na-sulfate minerals on Mars and Europa, recent studies using these minerals have focused on their ability to assist in the detection of bio/organic signatures. This study further investigates the ability of thenardite (Na2SO4) to effectively facilitate the ionization and identification of aromatic amino acids (phenylalanine, tyrosine, and tryptophan) using a technique called geomatrix-assisted laser desorption/ionization (GALDI) in conjunction with a Fourier transform mass spectrometry (FTICR-MS). This technique is based on the ability of a mineral host to facilitate the ionization and detection of bio/organic molecules. Spectra obtained from each aromatic amino acid alone and in combination with thenardite show differences in ionization mechanism and fragmentation patterns. These differences are due to chemical and structural differences between the aromatic side chains of their respective amino acid. Tyrosine and tryptophan when combined with thenardite were observed to undergo cation-attachment ([M+Na]+), due to the high alkali affinity of their aromatic side chains. Subsequent cation substitution of the carboxyl group led to formation double cation-attached peaks ([M-H+Na]Na+). In contrast, phenylalanine mixed with thenardite showed no evidence of Na+ interaction. Understanding how codeposition of amino acids with thenardite can affect the observed mass spectra is important for future exploration missions that are likely to use laser desorption mass spectrometry to search for bio/organic compounds in extraterrestrial environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First Step Toward Ultrafast Nuclear-Spin Polarization: All-optical Control and Direct Detection of Ultrafast Electron-Spin Polarization Using Femtosecond Laser Pulses

We demonstrate the first experimental observation of ultrafast electron-spin polarization upon photoionization using femtosecond and nanosecond lasers. For the optical detection of electron-spin polarization we measure the laser-induced fluorescence of photoions. The experimental results agree well with our theoretical results obtained by solving the time-dependent Schroedinger equations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dark Matter: Direct Detection

The identification of Dark Matter is an outstanding question of contemporary physics. I summarize the main experimental strategies developed to answer this question, focusing on cryogenic detectors and comparing these detectors to their double-phase xenon and argon competitors. I discuss in particular the main developments in charge-phonon (CDMS, EDELWEISS) and light-phonon detectors (CRESST, ROSEBUD). Finally, I discuss the prospects of WIMP detection within the next few years by the CDMS, CRESST, EDELWEISS and XENON experiments, and their successors EURECA, GEODM and XENON-1 ton.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new detector for mass spectrometry: Direct detection of low energy ions using a multi-pixel photon counter

A new type of ion detector for mass spectrometry and general detection of low energy ions is presented. The detector consists of a scintillator optically coupled to a single-photon avalanche photodiode (SPAD) array. A prototype sensor has been constructed from a LYSO (Lu{sub 1.8}Y{sub 0.2}SiO{sub 5}(Ce)) scintillator crystal coupled to a commercial SPAD array detector. As proof of concept, the detector is used to record the time-of-flight mass spectra of butanone and carbon disulphide, and the dependence of detection sensitivity on the ion kinetic energy is characterised.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-crystalline Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+x} detectors for direct detection of microwave radiation

We test radiation detectors made from single-crystalline Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+x} flakes put on oxidized Si substrates. The 100-nm-thick flakes are lithographically patterned into 4×12 μm{sup 2} large rectangles embedded in thin-film log-spiral antennas. The SiO{sub 2} layer weakens the thermal link between the flakes and the bath. Two modes of radiation detection have been observed. For a bolometric type of sensors a responsivity of ∼300 V/W and a noise equivalent power of 30 nW/√(Hz) has been deduced at 70 K. Much more sensitive is the non-bolometric device showing characteristics similar to a Golay-type detector while being at least a thousand times faster. Making smaller (sub-μm) structures is expected to significantly improve the performance of these devices and makes them very competitive among other microwave and terahertz detectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cryogenic scintillation properties of n -type GaAs for the direct detection of MeV/c 2 dark matter

This paper is the first report of n-type GaAs as a cryogenic scintillation radiation detector for the detection of electron recoils from interacting dark matter (DM) particles in the poorly explored MeV/c 2 mass range. Seven GaAs samples from two commercial suppliers and with different silicon and boron concentrations were studied for their low temperature optical and scintillation properties. All samples are n -type even at low temperatures and exhibit emission between silicon donors and boron acceptors that peaks at 1.33 eV (930 nm). The lowest excitation band peaks at 1.44 eV (860 nm), and the overlap between the emission and excitation bands is small. The X-ray excited luminosities range from 7 to 43 photons/keV. Thermally stimulated luminescence measurements show that n -type GaAs does not accumulate metastable radiative states that could cause afterglow. Further development and use with cryogenic photodetectors promises a remarkable combination of large target size, ultra-low backgrounds, and a sensitivity to electron recoils of a few eV that would be produced by DM particles as light as a few MeV/c 2 .

36 MATERIALS SCIENCE↗