Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors Instrumentation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Imaging large- and small-scale structures of the far ultraviolet background with the FAUST instrument

The FAUST telescope is an ultraviolet survey instrument that features a wide 8 deg field of view, 1-arcmin angular resolution, and a photon counting detector. Operating in the 1400-1800 A band, it will be sufficiently sensitive to detect blue m(v) = 17 objects in a single 20-minute night. The instrument is part of the ATLAS-1 shuttle mission, presently scheduled for flight in May 1991. A substantial number of high galactic latitude fields will be investigated, with particular emphasis on studies of the origin of the diffuse far UV background.

Lampton, M.↗

High Resolution Imager (HRI) for the Roentgen Satellite (ROSAT) definition study

The design of the high resolution imager (HRI) on HEAO 2 was modified for use in the instrument complement of the Roentgen Satellite (ROSAT). Mechanical models of the front end assembly, central electronics assembly, and detector assembly were used to accurately represent the HRI envelope for both fit checks and focal plane configuration studies. The mechanical and electrical interfaces were defined and the requirements for electrical ground support equipment were established. A summary description of the ROSAT telescope and mission is included.

Source record↗

A position sensitive detector for EUV remote sensing

The authors describe a photon-counting extreme ultraviolet (EUV) detector system used in a rocket-borne spectroscopic instrument for remote sensing of upper atmospheric composition and temperature. The detector uses a KBr coated microchannel plate (MCP) Z stack in combination with a wedge-and-strip image readout system. Three separate detector fields of view are used to sense the Earth dayglow spectrum (980 A to 1040 A, and 1300 A to 1360 A) and the solar EUV spectrum (250 A to 1400 A). The authors demonstrate high gain (2 x 107), tight pulse-height distribution (35 percent FWHM), and a spatial resolution of about 35 microns FWHM (full width at half maximum), which is the highest resolution for a wedge-and-strip anode MCP detector flown to date. The background, image linearity, and flat-field performance are discussed. Raw spectra from the rocket flight are also presented.

Siegmund, O. H. W.↗

Digital array scanned interferometers for astronomy

Investigations are reported of digital array scanned interferometers (DASI) with silicon CCD array detectors to define the operational capabilities of a mapping (polarimetric) spectrometer for astronomical applications based on these instruments. For spectral mapping, spatially resolved spectra using a cylindrical lens to image in the interferometers's redundant coordinate are given. The signal-to-noise characteristics of the Fourier transformed data are demonstrated with regard to the effects of a rectangular sampling function, spectral multiplexing and the pixel-to-pixel variation of the CCD array. These data indicate that DASIs can offer simple, versatile (polarization) mapping spectrometers suitable for spectral mapping observations from the ultraviolet to the infrared of extended sources at variable spatial resolution, particularly where long term stable operation is essential, as for spacecraft instruments.

Smith, Wm. Hayden↗

Rapid Protein Separations in Microfluidic Devices

This paper describes fabrication of glass and plastic microfluidic devices for protein separations. Although the long-term goal is to develop a microfluidic device for two-dimensional gel electrophoresis, this paper focuses on the first dimension-isoelectric focusing (IEF). A laser-induced fluorescence (LIF) imaging system has been built for imaging an entire channel in an IEF device. The whole-channel imaging eliminates the need to migrate focused protein bands, which is required if a single-point detector is used. Using the devices and the imaging system, we are able to perform IEF separations of proteins within minutes rather than hours in traditional bench-top instruments.

MICROFLUIDICS↗

(abstract) Radiometric Calibration of the Multi-angle Imaging Spectro-Radiometer

The EOS/MISR instrument has completed preflight calibration and characterization of its nine cameras. The radiometric calibration requirements includes absolute radiometric accuracy to 3 percent. To meet this challenging requirement MISR has employed detector based calibration methodology. The source, a 1.65 m integrating sphere, is spatially and spectrally featureless. Thus, when viewing scenes that are likewise homogeneous, the sensor incident radiance is easily retrieved to high accuracy. To enhance the radiance product for arbitrary scene types, however, MISR is planning to incorporate spectral out-of-band, point-spread function deconvolution, and pixel nonuniformity of response corrections. A summary of the preflight calibration is presented in this paper, as well as the error uncertainties for specific scene types with and without these processing corrections.

radiometric calibration EOS MISR↗

Development and Operation of the Microshutter Array System

The microshutter array (MSA) is a key component in the James Webb Space Telescope Near Infrared Spectrometer (NIRSpec) instrument. The James Webb Space Telescope is the next generation of a space-borne astronomy platform that is scheduled to be launched in 2013. However, in order to effectively operate the array and meet the severe operational requirements associated with a space flight mission has placed enormous constraints on the microshutter array subsystem. This paper will present an overview and description of the entire microshutter subsystem including the microshutter array, the hybridized array assembly, the integrated CMOS electronics, mechanical mounting module and the test methodology and performance of the fully assembled microshutter subsystem. The NIRSpec is a European Space Agency (ESA) instrument requiring four fully assembled microshutter arrays, or quads, which are independently addressed to allow for the imaging of selected celestial objects onto the two 4 mega pixel IR detectors. Each microshutter array must have no more than approx.8 shutters which are failed in the open mode (depending on how many are failed closed) out of the 62,415 (365x171) total number of shutters per array. The driving science requirement is to be able to select up to 100 objects at a time to be spectrally imaged at the focal plane. The spectrum is dispersed in the direction of the 171 shutters so if there is an unwanted open shutter in that row the light from an object passing through that failed open shutter will corrupt the spectrum from the intended object.

Jhabvala, M. D.↗

Low Cost, Low Power, Passive Muon Telescope for Interrogating Martian Sub-Surface

It has been demonstrated on Earth that a low power, passive muon detector can penetrate deep into geological structures up to several kilometers in size providing high density images of their interiors. Muon tomography is an entirely new class of planetary instrumentation that is ideally suited to address key areas in Mars Science, such as: the search for life and habitable environments, the distribution and state of water and ice and the level of geologic activity on Mars today.

Muons↗

Performance Testing of the Engineering Model Astro-H 3-stage ADR

The Japanese Astro-H mission will include the Soft X-ray Spectrometer (SXS) instrument provided by NASA/GSFC. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon microcalorimeters operated at 50 mK. The detectors are cooled by a 3-stage adiabatic demagnetization refrigerator (ADR), which is configured to use either a 1.3 K superfluid helium tank or a 4.5 K Joule-Thomson cryocooler as a heat sink. At present, the engineering model SXS, including the detectors and ADR, has been performance tested at GSFC and integrated with the EM dewar in Japan. The flight model SXS is currently being fabricated. This paper presents test results of the EM ADR and changes that will be implemented in the flight version.

Shirron, Peter J.↗

Design and Development of the Astro-H 3-Stage ADR

The Japanese Astro-H mission will include the Soft X-ray Spectrometer (SXS) instrument provided by NASA/GSFC. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon microcalorimeters operated at 50 mK. The detectors will be cooled by a 3-stage adiabatic demagnetization refrigerator (ADR). The configuration allows the ADR to operate with both a 1.3 K superfluid helium bath and a 4.5 K cryocooler as its heat sink. Initially, when liquid helium is present, the two coldest stages of the ADR will operate in a single-shot mode to cool the detectors from 1.3 K. The 3rd stage may be used to transfer heat from the liquid to the cryocooler to extend its lifetime. When the liquid is depleted, the two warmest stages will operate in a continuous mode to establish a 1.3 K base temperature, from which the cold stage will operate in a single-shot mode to cool the detectors. This paper will describe the design and operating modes of the ADR, as well as details of individual components.

Shirron, Peter J.↗

Radiometric and spectral stray light correction for the Portable Remote Imaging Spectrometer (PRISM) coastal ocean sensor

The airborne Portable Remote Imaging Spectrometer (PRISM) instrument is based on a fast (F/1.8) Dyson spectrometer operating at 350-1050 nm and a two-mirror telescope combined with a Teledyne HyViSI 6604A detector array. Raw PRISM data contain electronic and optical artifacts that must be removed prior to radiometric calibration. We provide an overview of the process transforming raw digital numbers to calibrated radiance values. Electronic panel artifacts are first corrected using empirical relationships developed from laboratory data. The instrument spectral response functions (SRF) are reconstructed using a measurement-based optimization technique. Removal of SRF effects from the data improves retrieval of true spectra, particularly in the typically low-signal near-ultraviolet and near-infrared regions. As a final step, radiometric calibration is performed using corrected measurements of an object of known radiance. Implementation of the complete calibration procedure maximizes data quality in preparation for subsequent processing steps, such as atmospheric removal and spectral signature classification.

Thompson, David R.↗

Compact Mid-Wave Imaging System (CMIS) for Retrieval of Cloud Motion Vectors and Cloud Geometric Heights

The Johns Hopkins University Applied Physics Laboratory (JHU/APL) is developing a compact, light-weight, and low power midwave-infrared (MWIR) imager called the Compact Midwave Imaging Sensor (CMIS), under the support of the NASA Earth Science Technology Office Instrument Incubator Program. The goal of this CMIS instrument development and demonstration project is to increase the technical readiness of CMIS, a multi-spectral sensor capable of retrieving 3D winds and cloud heights 24/7, for a space mission. The CMIS instrument employs an advanced MWIR detector that requires less cooling than traditional technologies and thus permits a compact, low-power design, which enables accommodation on small spacecraft such as CubeSats. CMIS provides the critical midwave component of a multi-spectral sensor suite that includes a high-resolution Day-Night Band and a longwave infrared (LWIR) imager to provide global cloud characterization and theater weather imagery. In this presentation, an overview of the CMIS project, including the high-level sensor design, the concept of operations, and measurement capability will be presented. System performance for a variety of different scenes generated by a cloud resolving model (CRM) will also be discussed.

midwave↗

Assessment of MODIS RSB Detector Uniformity Using Deep Convective Clouds

For satellite sensor, the striping observed in images is typically associated with the relative multiple detector gain difference derived from the calibration. A method using deep convective cloud (DCC) measurements to assess the difference among detectors after calibration is proposed and demonstrated for select reflective solar bands (RSBs) of the Moderate Resolution Imaging Spectroradiometer (MODIS). Each detector of MODIS RSB is calibrated independently using a solar diffuser (SD). Although the SD is expected to accurately characterize detector response, the uncertainties associated with the SD degradation and characterization result in inadequacies in the estimation of each detector's gain. This work takes advantage of the DCC technique to assess detector uniformity and scan mirror side difference for RSB. The detector differences for Terra MODIS Collection 6 are less than 1% for bands 1, 3-5, and 18 and up to 2% for bands 6, 19, and 26. The largest difference is up to 4% for band 7. Most Aqua bands have detector differences less than 0.5% except bands 19 and 26 with up to 1.5%. Normally, large differences occur for edge detectors. The long-term trending shows seasonal oscillations in detector differences for some bands, which are correlated with the instrument temperature. The detector uniformities were evaluated for both unaggregated and aggregated detectors for MODIS band 1 and bands 3-7, and their consistencies are verified. The assessment results were validated by applying a direct correction to reflectance images. These assessments can lead to improvements to the calibration algorithm and therefore a reduction in striping observed in the calibrated imagery.

Clouds↗

Building the James Webb Space Telescope

The James Webb Space Telescope is the scientific successor to the Hubble and Spitzer Space Telescopes. It will be a large (6.6m) cold (50K) telescope launched into orbit around the second Earth-Sun Lagrange point. It is a partnership of NASA with the European and Canadian Space Agencies. JWST will make progress In almost every area of astronomy, from the first galaxies to form in the early universe to exoplanets and Solar System objects. Webb will have four instruments: The Near-Infrared Camera, the Near-Infrared multi-object Spectrograph, and the Near-Infrared Imager and Slitless Spectrograph will cover the wavelength range 0.6 to 5 microns, while the Mid-Infrared Instrument will do both imaging and spectroscopy from 5 to 28.5 microns. The observatory Is confirmed for launch in 2018; the design is complete and it is in its construction phase. Innovations that make JWST possible include large-area low-noise infrared detectors, cryogenic ASICs, a MEMS micro-shutter array providing multi-object spectroscopy, a non-redundant mask for interferometric coronagraphy and diffraction-limited segmented beryllium mirrors with active wavefront sensing and control. Recent progress includes the completion of the mirrors, the delivery of the first flight instruments and the start of the integration and test phase.

Gardner, Jonathan P.↗

A quadratic analog-to-digital converter

An analog-to-digital converter with a square root transfer function has been developed for use with a pair of CCD imaging detectors in the White Light Coronagraph/X-ray XUV Telescope experiment to be flown as part of the Internal Solar Polar Mission. It is shown that in background-noise-limited instrumentation systems a quadratic analog-to-digital converter will allow a maximum dynamic range with a fixed number of data bits. Low power dissipation, moderately fast conversion time, and reliability are achieved in the proposed design using standard components and avoiding nonlinear elements.

Harrison, D. C.↗

Dayside Aurora Dynamics

Images from the FUV (Far UltraViolet) instrument on board the IMAGE spacecraft will be presented to demonstrate the auroral dynamics in the dayside auroral zone and the polar cap region. optical emissions detected by three different detectors of FUV come from precipitations of energetic protons, electrons, and both species, respectively. In general, auroral activities in these regions responded very well to variations in the boundary conditions either external or internal to the magnetosphere, i.e., in the solar wind or the magnetotail. As a result, auroral images from FUV provide an excellent tool to investigate particle acceleration and transport processes within the geospace, such as shock acceleration, substorm injections, etc. we will interpret the observed auroral images using various models, discuss difference and similarity in the auroral activity from several typical cases, and assess conditions optimal to each type of auroral activity.

Spann, James F.↗

Polarization Characteristics of Spectralon Illuminated by Coherent Light

The Multi-angle Imaging Spectroradiometer (MISR) makes use of an on-board calibration system to provide routine absolute radiometric calibrations of the instrument while in flight. In addition to on-board detector standards, two spectralon panels will reflect sunlight into the nine cameras.

reflectance standards spectralon polarization↗

Benchmarking Simulations of the Compton Spectrometer and Imager with Calibrations

The Compton Spectrometer and Imager (COSI) is a balloon-borne 𝛾-ray (0.2-5 MeV) telescope designed to study astrophysical sources. COSI employs a compact Compton telescope design utilizing 12 high-purity germanium double-sided strip detectors and is inherently sensitive to polarization. In 2016, COSI was launched from Wanaka, New Zealand and completed a successful 46-day flight on NASA’s new Super Pressure Balloon. In order to perform imaging, spectral, and polarization analysis of the sources observed during the 2016 flight, we compute the detector response from well-benchmarked simulations. As required for accurate simulations of the instrument, we have built a comprehensive mass model of the instrument and developed a detailed detector effects engine which applies the intrinsic detector performance to Monte Carlo simulations. The simulated detector effects include energy, position, and timing resolution, thresholds, dead strips, charge sharing, charge loss, crosstalk, dead time, and detector trigger conditions. After including these effects, the simulations closely resemble the measurements, the standard analysis pipeline used for measurements can also be applied to the simulations, and the responses computed from the simulations are accurate. We have computed the systematic error that we must apply to measured fluxes at certain energies, which is 6.3% on a rage. Here we describe the detector effects engine and the benchmarking tests performed with calibrations.

Sleator, Clio C.↗