Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIAGNOSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Battery aging mode identification across NMC compositions and designs using machine learning

A comprehensive understanding of lithium-ion battery (LiB) lifespan is the key to designing durable batteries and optimizing use protocols. Although battery lifetime prediction methods are flourishing, diagnosis of the root causes of aging and degradation have not yet been well developed nor studied for a broad mixture of designs and use cases. Here, we create a machine-learning (ML)-based framework that distinguishes aging modes using multiple electrochemical signatures recorded cycle-by-cycle. The predominant aging behaviors include a combination of loss of active materials in cathode (LAMPE) and a loss of Li inventory (LLI) in Li plating or solid electrolyte interphase (SEI) formation, manifested from 44 batteries representing two cathode chemistries, two electrode loadings, and five charging rates. Here, the aging mode classification accuracy is 86% using features within the first 50 cycles and increases to 88% beyond 225 cycles. The same features can quantify the percentage of end-of-life LAMPE with only 4.3% of error.

25 ENERGY STORAGE↗

Comparison of Expert Vocabulary Usage Patterns Between Mental Health and Nonmental Health Clinicians When Diagnosing Pediatric Anxiety Disorders

Objective: To compare the utilization patterns of expert vocabulary (EVo) in diagnosing pediatric anxiety between mental health and non-mental health clinical notes from electronic health records to understand the role of Evo in informing classification and decision-making in anxiety diagnoses. Study design: We conducted a retrospective study using a cohort less than age 25 from Cincinnati Children's Hospital including 897 685 patients with 61 586 446 notes. We analyzed EVo, collected from mental health clinicians, in both mental and nonmental health notes. We compared classification accuracy using EVo-based patient-level embedding from all clinical notes, mental-health notes, and nonmental health notes for 2 tasks: 1) pre-vs postdiagnosis anxiety patients, and 2) prediagnosis anxiety vs nonanxiety patients. Results: EVo usage was highest in prediagnosis anxiety, lower in nonanxiety, and lowest in post-diagnosis. Classification models using EVo features from all, mental-health, and non-mental health notes showed similar F1 scores for prediagnosis anxiety (0.70 ± 0.2 for 2 categories). For anxiety vs nonanxiety classification, all clinical and nonmental health notes had better F1 scores than mental-health notes (above 0.90 for 3 categories). There was a notable difference in class-wise performance across both tasks. Conclusions: There are significant differences in anxiety EVo use between mental health and nonmental health clinicians. Despite less anxiety-specific terminology, non-mental health notes still captured key aspects of patient presentations, emphasizing the importance of including all clinicians' notes in analysis. EVo's utility for anxiety classification is most effective in prediagnostic phases, suggesting the need for a dedicated diagnostic lexicon and further study before incorporating EVo into classification models.

feature engineering↗

In-situ electrochemical optical techniques in the investigation of lithium interfacial phenomena with a liquid and a solid-state electrolyte

An in-situ electrochemical optical diagnosis is the key to the investigation of electrode interface during a redox reaction. Because the morphology changes particularly, dendrite formation, dendrite shapes, solid electrolyte interface formation and gas generation can be revealed visually. The challenge of ensuring uniform current density on a flat Li anode in a liquid electrolyte was addressed and uniform Li plating was demonstrated. The dendrite shape change under different reduction current density was discussed. Here the Li dendrite shape change and the performance of Li anodes with a surface lamination of graphite and red phosphate were used as examples to demonstrate the capability of the in-situ optical cell. An in-situ electrochemical optical cell used in the investigation of the increasingly popular solid-state Li batteries has its own challenges. Due to the untransparent nature of a solid-state electrolyte, an optical investigation on a solid-state electrolyte Li battery needs to be done by exposing the cross-section of the cell. In addition, it is very difficult to assemble an optical cell with a brittle and fragile solid-state electrolyte in a glove box. A set of formation and transfer dies, and an optical cell were introduced. The Li dendrite growth at the interface can be observed in a solid-state Li cell.

25 ENERGY STORAGE↗

NaroNet: Discovery of tumor microenvironment elements from highly multiplexed images

Understanding the spatial interactions between the elements of the tumor microenvironment -i.e. tumor cells. fibroblasts, immune cells- and how these interactions relate to the diagnosis or prognosis of a tumor is one of the goals of computational pathology. We present NaroNet, a deep learning framework that models the multi-scale tumor microenvironment from multiplex-stained cancer tissue images and provides patient-level interpretable predictions using a seamless end-to-end learning pipeline. Trained only with multiplex-stained tissue images and their corresponding patient-level clinical labels, NaroNet unsupervisedly learns which cell phenotypes, cell neighborhoods, and neighborhood interactions have the highest influence to predict the correct label. To this end, NaroNet incorporates several novel and state-of-the-art deep learning techniques, such as patch-level contrastive learning, multi-level graph embeddings, a novel max-sum pooling operation, or a metric that quantifies the relevance that each microenvironment element has in the individual predictions. We validate NaroNet using synthetic data simulating multiplex-immunostained images where a patient label is artificially associated to the -adjustable- probabilistic incidence of different microenvironment elements. We then apply our model to two sets of images of human cancer tissues: 336 seven-color multiplex-immunostained images from 12 high-grade endometrial cancer patients; and 382 35-plex mass cytometry images from 215 breast cancer patients. In both synthetic and real datasets, NaroNet provides outstanding predictions of relevant clinical information while associating those predictions to the presence of specific microenvironment elements.

60 APPLIED LIFE SCIENCES↗

Accurate and rapid acoustic damage characterization in complex structures using sparse sensor networks and deep learning models

Damage diagnosis in critical components is essential for ensuring the safety and reliability of operations across industries, spanning manufacturing, aerospace, and energy. Traditional acoustic nondestructive testing methods primarily focus on detecting defects through the direct scattering of single-mode incident waves from the damage, which limit their applicability to simple structures and small inspection areas. Our earlier research demonstrated that machine learning algorithms combined with sparse sensor networks can identify critical defect signatures even from multiply scattered, multi-mode acoustic signals, indicating the potential for improved defect inspection in complex, real-world structures. In this work, we demonstrate the successful implementation of this approach in a fixed sensor configuration to rapidly and accurately detect simulated defects in a geometrically complex, real-world structure, a brake rotor hub. Three different types of defects were physically simulated on the surface of the hub, and the collected data were used to train an autoencoder-based deep learning model. Two models were tested, one using single measurements and the other using multiple measurements taking advantage of the spatial distribution of the sensor network. After training, the multi-measurement model achieved 100 % accuracy in identifying, classifying, and locating unseen, unique damages. This work illustrates the potential of the proposed method for a wide range of industrial applications.

36 MATERIALS SCIENCE↗

Reliable statistics-based detection and investigation of anomalies in a SMART valve system

Reliable anomaly detection and diagnosis are critical for the safe operation of complex engineered systems. This study presents a unified framework that integrates statistical, model-based, and data-driven techniques for anomaly detection and investigation, demonstrated on SMART valve systems in hybrid energy applications. Four detection methods—mean deviation, seasonal extreme studentized deviate, ARIMA forecasting, and matrix profiling—were implemented and compared. Matrix profiling was particularly effective in revealing subtle deviations and hidden relationships among variables. Anomaly investigation was performed by analyzing variable-level and grouped signal profiles, with system topology incorporated to distinguish primary faults from propagated effects. Grouping signals by type enhanced interpretability, enabling accurate localization of anomalies across multi-dimensional datasets. Experimental results confirmed the framework's capability to consistently detect and isolate anomalies while providing actionable insights into system interdependencies. The proposed methodology offers a robust, interpretable, and scalable solution for condition monitoring, with potential applications in safety-critical domains such as nuclear energy, aerospace, and process industries.

ARIMA models↗

Deep learning for Alzheimer's disease: Mapping large-scale histological tau protein for neuroimaging biomarker validation

Abnormal tau inclusions are hallmarks of Alzheimer's disease and predictors of clinical decline. Several tau PET tracers are available for neurodegenerative disease research, opening avenues for molecular diagnosis in vivo. However, few have been approved for clinical use. Understanding the neurobiological basis of PET signal validation remains problematic because it requires a large-scale, voxel-to-voxel correlation between PET and (immuno) histological signals. Large dimensionality of whole human brains, tissue deformation impacting co-registration, and computing requirements to process terabytes of information preclude proper validation. We developed a computational pipeline to identify and segment particles of interest in billion-pixel digital pathology images to generate quantitative, 3D density maps. The proposed convolutional neural network for immunohistochemistry samples, IHCNet, is at the pipeline's core. We have successfully processed and immunostained over 500 slides from two whole human brains with three phospho-tau antibodies (AT100, AT8, and MC1), spanning several terabytes of images. Our artificial neural network estimated tau inclusion from brain images, which performs with ROC AUC of 0.87, 0.85, and 0.91 for AT100, AT8, and MC1, respectively. Introspection studies further assessed the ability of our trained model to learn tau-related features. We present an end-to-end pipeline to create terabytes-large 3D tau inclusion density maps co-registered to MRI as a means to facilitate validation of PET tracers.

60 APPLIED LIFE SCIENCES↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

Diagnosing nuclear power plant pipe wall thinning due to flow accelerated corrosion using a passive, thermal non-destructive evaluation method: Feasibility assessment via numerical experiments

Flow accelerated corrosion (FAC) in nuclear power plant pipes is one of the leading causes of accidents, fatalities, damage and outages. Current FAC identification methods employ expensive sensing technology and are “active” methods, where the response of the piping system to an externally-generated thermal, mechanical or optical excitation must be measured. As a result, these techniques require a disruptive and time-consuming setup. Here we propose a method that utilizes pipe surface temperature measurements to passively monitor for FAC-induced pipe wall thinning without the need for expensive equipment or post-installation setup time. This diagnostic method utilizes a simulation data-driven diagnostic model to estimate the amount of thickness reduction in a pipe based on changes in measured steady-state pipe temperatures. In order to reduce the computational burden of generating large, simulation-based datasets, the behavior of the insulation of the pipe was modeled using a suitably calibrated heat transfer boundary parameter. Additionally, global sensitivity analysis was performed to determine system parameter(s), such as the temperature of water flowing inside the pipe, which significantly affect the steady state pipe wall temperature and could cause errors in diagnosis. Two diagnostic models, one using only the change in steady-state temperature as an indicator for FAC-induced pipe wall thinning and the other using water temperature as an additional diagnostic model input were evaluated for their ability to estimate thickness reductions in a pipe using simulated pipe wall temperature data. For the numerical experiments conducted in this work, both models estimated wall thickness with errors within 0.5 mm, indicating that the proposed technique can potentially be used as a low-cost, first-pass method for FAC monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Polychlorinated biphenyls, polychlorinated dibenzo- p -dioxins, polychlorinated dibenzofurans, pesticides, and diabetes in the Anniston Community Health Survey follow-up (ACHS II): single exposure and mixture analysis approaches

Dioxins and dioxin-like compounds measurements were added to polychlorinated biphenyls (PCBs) and organochlorine pesticides to expand the exposure profile in a follow-up to the Anniston Community Health Survey (ACHS II, 2014) and to study diabetes associations. Participants of ACHS I (2005–2007) still living within the study area were eligible to participate in ACHS II. Diabetes status (type-2) was determined by a doctor's diagnosis, fasting glucose ≥125 mg/dL, or being on any glycemic control medication. Incident diabetes cases were identified in ACHS II among those who did not have diabetes in ACHS I, using the same criteria. Thirty-five ortho-substituted PCBs, 6 pesticides, 7 polychlorinated dibenzo-p-dioxins (PCDD), 10 furans (PCDF), and 3 non-ortho PCBs were measured in 338 ACHS II participants. Dioxin toxic equivalents (TEQs) were calculated for all dioxin-like compounds. Main analyses used logistic regression models to calculate odds ratios (OR) and 95 % confidence intervals (CI). In models adjusted for age, race, sex, BMI, total lipids, family history of diabetes, and taking lipid lowering medication, the highest ORs for diabetes were observed for PCDD TEQ: 3.61 (95 % CI: 1.04, 12.46), dichloro-diphenyl dichloroethylene (p,p’-DDE): 2.07 (95 % CI 1.08, 3.97), and trans-Nonachlor: 2.55 (95 % CI 0.93, 7.02). The OR for sum 35 PCBs was 1.22 (95 % CI: 0.58–2.57). To complement the main analyses, we used BKMR and g-computation models to evaluate 12 mixture components including 4 TEQs, 2 PCB subsets and 6 pesticides; suggestive positive associations for the joint effect of the mixture analyses resulted in ORs of 1.40 (95% CI: -1.13, 3.93) for BKMR and 1.32 (95% CI: -1.12, 3.76) for g-computation. Furthermore, the mixture analyses provide further support to previously observed associations of trans-Nonachlor, p,p’- DDE, PCDD TEQ and some PCB groups with diabetes.

60 APPLIED LIFE SCIENCES↗

Degradation mechanisms and partial shading of glass-backsheet and double-glass photovoltaic modules in three climate zones determined by remote monitoring of time-series current–voltage and power datastreams

Degradation and partial shading impact the long-term reliability and power production of photovoltaic (PV) modules and power plants. Time-series power (P mp ) and current–voltage (I-V) curve datastreams from PV modules enable a remote diagnostic approach to quantify active degradation mechanisms and identify partial shading. We study three to nine years of these datastreams, including 3.6 million P mp I-V curves and 36 million values, from eight PV modules, four each of double-glass and glass-backsheet module architectures, located in three distinctly different Köppen-Geiger climate zones, to determine the module’s performance loss rates (PLR), identify active degradation mechanisms and power loss modes, along with partial shading by local objects. Considering both module architectures, PLR results indicate that the BSh climate zone is the most aggressive for module degradation, while the Alpine ET zone is the mildest climate. PLR of double-glass modules located in BWh and BSh climate zones are different due to the significantly greater uniform current loss (ΔP Isc ) for double-glass modules in BSh, at a 5% significance level. Power loss for four out of five modules located in the BWh and BSh climates are dominated by uniform current degradation. Statistical analysis of multistep I-V curves detects partial shading experienced by three studied modules with details of the shading profile, the shading Poynting vector diagram for the obstacle’s relative position, shading scenarios, and duration. Lastly, this work demonstrates how remote monitoring and diagnosis of P mp & I-V time-series of modules can provide quantitative operations and maintenance insights into system performance, degradation mechanisms, and shading.

14 SOLAR ENERGY↗

Comprehensive analysis of differentially expressed mRNA and circRNA in Ankylosing spondylitis patients’ platelets

Highlights: • 4996 mRNAs and 2942 circRNAs were identified differentially expressed in platelets of AS patients. • Several platelet-derived immune mediators were upregulated to regulate the interaction between platelets and immune cells. • Two downregulated circRNA were identified, and the corresponding circRNA-miRNA-mRNA regulatory network was constructed. • mRNAs and circRNAs found herein could be used as diagnostic biomarkers or new therapeutic targets. Ankylosing spondylitis (AS) is a chronic inflammatory disease significantly decreasing the quality of life. Platelets play an important and active role in the development of AS. Accumulating evidence demonstrated platelets contain diverse RNA repository inherited from megakaryocytes or microvesicles. Platelet RNAs are dynamically affected by pathological conditions and could be used as diagnostic or prognostic biomarkers. However, the role of the platelet RNAs in AS is elusive. In this study, we compared mRNA and circRNA profiles in platelets between AS patients and healthy controls using RNA sequencing and bioinformatic analysis, and found 4996 mRNAs and 2942 circRNAs were differently expressed. The significantly over-expressed mRNAs in AS patients are involved in platelet activity, gap junction, focal adhesion, rap1 and toll and Imd signaling pathway. The previous identified platelet-derived immune mediators such as P2Y1, P2Y12, PF4, GPIbα, CD40L, ICAM2, CCL5 (RANTES), TGF-β (TGF-β1 and TGF-β2) and PDGF (PDGFB and PDGFA) are also included in these over expressed mRNAs, implying these factors may trigger inflammatory cascades and promote the development of AS. Additionally, we found two down-regulated circRNA (circPTPN22 and circFCHSD2) from the intersection analyses of platelets and spinal ligament tissues of AS patients. The circRNA-miRNA-mRNA regulatory network of these two circRNAs was constructed, and the target mRNAs were enriched in Th17 cell differentiation, inflammatory bowel disease, cell adhesion molecules, cytokine-cytokine receptor interaction, Jak-STAT and Wnt signaling pathway, all these pathways participate in the bone remodeling and pro/anti-inflammatory immune regulation in AS. Then, qRT-PCR was performed to validate the expression of selected key mRNAs and circRNAs and the results demonstrated that the expression levels of P2Y12, GPIbα, circPTPN22 and circFCHSD2 were consistent with the sequencing analysis. In addition, the high expression of five predicted miRNAs interacting with circPTPN22 and circFCHSD2 were also detected in AS by qRT-PCR. Taken together, our study presents a comprehensive overview of mRNAs and circRNAs in platelets in AS patients and offers new insight into the mechanisms of platelet involving in the pathogenesis of AS. The mRNAs and circRNAs identified in this study may serve as candidates for diagnosis and targeted treatment of AS.

60 APPLIED LIFE SCIENCES↗

An Application of ASP in Nuclear Engineering: Explaining the Three Mile Island Nuclear Accident Scenario

Abstract The paper describes an ongoing effort in developing a declarative system for supporting operators in the Nuclear Power Plant (NPP) control room. The focus is on two modules: diagnosis and explanation of events that happened in NPPs. We describe an Answer Set Programming (ASP) representation of an NPP, which consists of declarations of state variables, components, their connections, and rules encoding the plant behavior. We then show how the ASP program can be used to explain the series of events that occurred in the Three Mile Island, Unit 2 (TMI-2) NPP accident, the most severe accident in the USA nuclear power plant operating history. We also describe an explanation module aimed at addressing answers to questions such as “why an event occurs?” or “what should be done?” given the collected data.

Computer Science↗

A Size-Selectively Biomolecule-Immobilized Nanoprobe-Based Chemiluminescent Lateral Flow Immunoassay for Detection of Avian-Origin Viruses

Here, a signal-amplifiable nanoprobe-based chemiluminescent lateral flow immunoassay (CL-LFA) was developed to detect avian influenza viruses (AIV) and other contagious and fatal viral avian-origin diseases worldwide. Signal-amplifiable nanoprobes are capable of size-selective immobilization of antibodies (binding receptors) and enzymes (signal transducers) on sensitive paper-based sensor platforms. Particle structure designs and conjugation pathways conducive for antigen accessibility to maximum amounts of immobilized enzymes and antibodies have advanced. The detection limit of the CL-LFA using the signal-amplifiable nanoprobe for the nucleoprotein of the H3N2 virus was 5 pM. Sensitivity tests for low pathogenicity avian influenza H9N2, H1N1, and high pathogenicity avian influenza H5N9 viruses were conducted, and the detection limits of CL-LFA were found to be 10 3.5 50% egg infective dose (EID 50 )/mL, 10 2.5 EID 50 /mL, and 10 4 EID 50 /mL, respectively, which is 20 to 100 times lower than that of a commercial AIV rapid test kit. Moreover, CL-LFA demonstrated high sensitivity and specificity against 37 clinical samples. The signal-amplifiable probe designed in this study is a potential diagnostic probe with ultrahigh sensitivity for applications in the field of clinical diagnosis, which requires sensitive antigen detection as evidenced by enhanced signaling capacity and sensitivity of the LFAs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

National Cancer Institute Think-Tank Meeting Report on Proteomic Cartography and Biomarkers at the Single-Cell Level: Interrogation of Premalignant Lesions

A Think-Tank Meeting was convened by the National Cancer Institute (NCI) to solicit experts’ opinion on the development and application of multi-omic single-cell analyses, and especially single-cell proteomics, to improve the development of a new generation of biomarkers for cancer risk, early detection, diagnosis, prognosis as well as to discuss the discovery of new targets for prevention and therapy. It is anticipated that such markers and targets will be based on cellular, subcellular, molecular and functional aberrations within the lesion and within individual cells. Additionally, single-cell proteomic data will be essential for the establishment of new tools that with searchable and scalable features that include spatial and temporal cartographies of premalignant and malignant lesions. Challenges and potential solutions that were discussed included: • The best way/s to analyze single-cells from fresh and preserved tissue • Detection and analysis of secreted molecules and from single cells, especially from a tissue slice • Detection of new, previously undocumented cell type/s in the premalignant and early stage cancer tissue microenvironment • Multi-omic integration of data to support and inform proteomic measurements • Subcellular organelles – identifying abnormal structure, function, distribution and location within individual premalignant and malignant cells • How to improve the dynamic range of single-cell proteomic measurements for discovery of differentially expressed proteins and their post translational modifications (PTM) • The depth of coverage measured concurrently using single-cell techniques • Quantitation - absolute or semiquantitative? • Single methodology or multiplexed combinations? • Application of analytical methods for identification of biologically significant subsets • Data visualization of N-dimensional datasets • How to construct intercellular signaling networks in individual cells within premalignant tumor microenvironments (TME) • Associations between intrinsic cellular processes and extrinsic stimuli • How to predict cellular responses to stress inducing stimuli • Identification of new markers for prediction of progression from precursor, benign and localized lesions to invasive cancer, based on spatial and temporal changes within individual cells • Identification of new targets for immunoprevention or immunotherapy – identification of neoantigens and surfactome of individual cells within a lesion

59 BASIC BIOLOGICAL SCIENCES↗

Prelithiated SiO x /Graphite-NMC811 Cells: Capacity Loss, Impedance Rise and Hidden Degradation Pathways Revealed Using Three-Electrode Diagnostics

Electrodes containing SiO x /graphite (Gr) materials are attractive as anodes for high-energy lithium-ion batteries. However, their mechanical deformation, electrochemical response, and impedance evolution during long-term cycling are strongly coupled, complicating accurate diagnosis of performance fade mechanisms. In this work, the behavior of electrochemically prelithiated SiO x /Gr anodes paired with NMC811 cathodes is systematically investigated using techniques that include in-situ dilatometry, three-electrode electrochemistry, and multiscale post-cycling microscopy. The SiO x /Gr electrode exhibits a maximum expansion of 49% upon lithiation to 10 mV vs Li + /Li, with 84% of the expansion and 91% of the capacity being reversible. In full cells, relatively stable cycling with only 12% capacity fade over 500 cycles is observed. Three-electrode experiments reveal cell-level impedance growth, which is dominated by the NMC811 cathode: the SiO x /Gr anode exhibits minimal net impedance rise and an initial impedance decrease at low potentials. Despite this apparent electrochemical stability, cross-sectional SEM, PFIB tomography, and cryo-STEM reveal irreversible anode thickening caused by the accumulation of an inorganic-rich solid electrolyte interphase (SEI) permeating the anode bulk. Electrode potential-shift analysis further demonstrates that Li + ions released from lithium reservoirs in the prelithiated anode mask true lithium inventory loss during aging. These results demonstrate that low-expansion SiO x /Gr anodes can simultaneously exhibit favorable cycling and impedance metrics while undergoing substantial, hidden degradation, underscoring the importance of electrode-resolved diagnostics for evaluating prelithiated silicon-based anodes.

25 ENERGY STORAGE↗

Bimetallic Metal–Organic Framework Fe/Co-MIL-88(NH 2 ) Exhibiting High Peroxidase-like Activity and Its Application in Detection of Extracellular Vesicles

Metal–organic frameworks (MOFs) have many attractive features, including tunable composition, rigid structure, controllable pore size, and large specific surface area, and thus are highly applicable in molecular analysis. Depending on the MOF structure, a high number of un-saturated metal sites can be exposed to catalyze chemical reactions. In the present work, we report that by using both Co(II) and Fe(III) to prepare the MIL-88(NH 2 ) MOF, we can produce the bimetallic MOF that can catalyze the conversion of 3,3', 5,5"-tetramethylbenzidine (TMB) to a color product through reaction with H 2 O 2 at a higher reaction rate than the monometallic Fe-MIL-88(NH 2 ). The Michaelis constants (K m ) of the catalytic reaction for TMB and H 2 O 2 are 3-5 times smaller, and the catalytic constants (k cat ) are 5-10 times higher than those of the horse-radish peroxidase (HRP), supporting ultrahigh peroxidase-like activity. These values are also much more superior to those of the HRP-mimicking MOFs reported previously. Interestingly, the bimetallic MOF can be coupled with glucose oxidase (GOx) to trigger the cascade enzymatic reaction for highly sensitive detection of extracellular vesicles (EVs), a family of important biomarkers. Through conjugation to the aptamer that recognizes the marker protein on EV surface, the MOF can help isolate the EVs from biological matrices, which are subsequently labeled by GOx via antibody recognition. The cascade enzymatic reaction between MOF and GOx enables detection of EVs at a concentration as low as 7.8 × 10 4 particles/ml. Further, the assay can be applied to monitor EV secretion by cultured cells, and also can successfully detect the different EV quantities in the sera samples collected from cancer patients and healthy controls. Overall, we prove that the bimetallic Fe/Co-MIL-88(NH 2 ) MOF, with its high peroxidase-activity and high biocompatibility, is a valuable tool deployable in clinical assays to facility disease diagnosis and prognosis.

36 MATERIALS SCIENCE↗

Rapid, Sensitive, Label-Free Electrical Detection of SARS-CoV-2 in Nasal Swab Samples

Rapid diagnosis of coronavirus disease 2019 (COVID-19) is key for the long-term control of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) amid renewed threats of mutated SARS-CoV-2 around the world. Here, we report on an electrical label-free detection of SARS-CoV-2 in nasopharyngeal swab samples directly collected from outpatients or in saliva-relevant conditions by using a remote floating-gate field-effect transistor (RFGFET) with a 2-dimensional reduced graphene oxide (rGO) sensing membrane. RFGFET sensors demonstrate rapid detection (<5 min), a 90.6% accuracy from 8 nasal swab samples measured by 4 different devices for each sample, and a coefficient of variation (CV) < 6%. Also, RFGFET sensors display a limit of detection (LOD) of pseudo-SARS-CoV-2 that is 10 000-fold lower than enzyme-linked immunosorbent assays, with a comparable LOD to that of reverse transcriptionpolymerase chain reaction (RT-PCR) for patient samples. To achieve this, comprehensive systematic studies were performed regarding interactions between SARS-CoV-2 and spike proteins, neutralizing antibodies, and angiotensin-converting enzyme 2, as either a biomarker (detection target) or a sensing probe (receptor) functionalized on the rGO sensing membrane. Finally, taken together, this work may have an immense effect on positioning FET bioelectronics for rapid SARS-CoV-2 diagnostics.

60 APPLIED LIFE SCIENCES↗