Graphene oxide nanofiltration membranes for desalination under realistic conditions
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Significance Researchers lack the tools for quantitatively evaluating the impact of their research on technology costs, especially when those technologies comprise multiple components or when the component costs are highly uncertain. We propose a suite of tools to aid in evaluating technology platforms, setting system- and component-level research targets and identifying high-impact innovation trajectories. These tools are applicable to any technology composed of multiple components whose performance or cost will benefit from innovation, but they are especially valuable for membrane systems in which the high interdependence in components amplifies or dampens the effects of innovation in nonintuitive ways.
In this project, we attempted to use additive manufacturing techniques to produce capacitive deionization (CDI) devices with improved performance. Direct ink writing, two-photon polymerization, and microstereolithography were used to produce segmented electrodes for CDI with a lower thickness than can be produced currently with bulk fabrication methods. The electrode thickness is a principle driver of device resistance, and, therefore, the energy consumption of the device. While we identified several pitfalls for producing interdigitated electrodes with low thickness and potential paths to overcome them, we were unable to print a useful structure within the scope of this project.
Abstract not provided.
Geologic carbon dioxide sequestration (GCS) will play a crucial role in limiting anthropogenic greenhouse gas emissions. GCS is the practice of capturing carbon dioxide (CO 2 ) from industrial sources and storing it in subsurface geologic formations, such as saline formations. These saline formations are typified by a porous interconnected rock strata, saturated with saline brine at a depth of >800 m. Because of the large volumes available, storage of CO 2 into deep saline formations with caprock seals and far from exiting faults will be key for long term reductions of anthropogenic CO 2 emissions. The high pressure injection of CO 2 into the subsurface can cause an increase in subsurface pressure. Open and highly porous formations can have CO 2 injected without causing a significant rise in formation pressure; however, closed or low porosity formations are more sensitive to the subsurface injection of CO 2 with regard to subsurface pressure. Such formations would ideally be located near existing fossil fuel power plants or other industrial emitters of CO 2 who would require GCS. In order to reduce the risk of induced seismic activity near minor fault structures, formation pressure management is needed. This will require the extraction of brines from the formation and these brines could be extracted prior to or during GCS. This extraction will maintain or reduce the subsurface pressure and enhance CO 2 storage capacity. The extracted brine can be dewatered/desalinated, becoming both a source of usable water and a concentrated brine which could be either reinjected into a nearby formation, crystallized, or discharged into an evaporation pond. The Department of Energy Office of Fossil Energy’s commitment to studying formation pressure management in GCS has been demonstrated with the recent awarding of $30,000,000 for two Brine Extraction Storage Test (BEST) projects, whose main goal is to develop and validate strategies for managing formation pressure through brine (Martin 2016). A secondary goal of these projects is to develop and demonstrate processes to extract usable water from these high salinity produced brines.
Abstract not provided.
A digital twin is a computer model that has sufficient breadth and fidelity to enable diagnostic and predictive analyses for outputs of interest. We have constructed a digital twin of the SB desal plant using the ProteusLib software developed for NAWI under task 4.2.2, and specifically the ProteusLib models of pumps, filters, mixers, splitters, and reverse osmosis units and a seawater property model. The steps needed to configure this digital twin with the real conditions of the SB desal plant are: (1) Data reconciliation, which is gathering the data and plant connectivity and ensure that all relevant values are present and in the correct units and validating the data using material and energy balances, and correct for errors, gaps, or deviations; (2) Parameter estimation, which is matching model parameters with data from previous step, filling missing parameters with initial estimates, then iteratively refining estimated values. Once we completed the digital twin, we used the optimization capabilities of ProteusLib to compute outputs of interest over a chosen range of inputs. The primary output of interest to the owners of the plant is its specific energy consumption (kWh/acre-foot). The remainder of this report will provide more detail on the data reconciliation, parameter estimation, and analyses we performed.
Abstract not provided.
The research team at UC Merced designed, prototyped, and tested (1) a novel low cost non-tracking solar thermal collector/concentrator called the Integrated Compound Parabolic Concentrator (ICPC) and (2) a low-cost phase-change thermal energy storage system. Together these technologies can significantly reduce the levelized cost of heat from solar thermal sources while also incorporating features of dispatchability and portability. The ICPC allows elevated temperature and efficiency in a low cost, non-tracking collector. The collector has demonstrated 60% ±4% solar to thermal modules efficiency at fluid outlet temperature of 120°C. The raw material cost of the collector system is reduced by utilizing low cost aluminum minichannels. The collector design is also amenable to economic mass production. A 200 tube, 10 kW prototype array was constructed and tested, yielding over 6 kWh/day on average at outlet fluid temperature exceeding 120°C.
Membrane treatment of secondary effluent for reuse applications is a promising approach to expand water supplies and provide flexibility to water resources management. However, effective control of membrane fouling and scaling is crucial for cost-effective treatment and system resilience. This study compared the performance of antiscalants to an alternating, current-induced electromagnetic field (EMF) as an alternative pretreatment method to reverse osmosis. Compared to the no-EMF control experiments, the EMF device resulted in 13% higher water recovery and 366% lower flux decline at 60% of water recovery, along with 2–8 times lower precipitation of fouling and scaling, as evidenced by scanning electron microscope, energy dispersive X-ray spectroscopy, and chemical extraction analysis. The combination of the EMF with antiscalant was more effective for reducing membrane fouling and scaling, increasing water recoveries up to 89.3%, as compared to the EMF (67.5%) and antiscalant-only (73.6%) configurations. This is the first study to demonstrate synergistic effects of using an EMF in combination with antiscalants and could lead to lower pretreatment costs. Additional research is required to quantify the economics of this approach and to fully understand the fundamental mechanisms governing fouling and scaling control by an EMF.
Conference proceedings for Foundations of Computer Aided Process Design (FOCAPD) 2024 that details a cost optimization model for pH control to prevent mineral scaling in high recovery reverse osmosis. This work applies a framework for incorporating detailed water chemistry predictions such as precipitation, pH change, and mineral scaling tendencies with process-scale optimization. It demonstrates that the acid choice for pH control can have a significant impact on pretreatment costs.
The present invention provides a membrane, kit, and method of making a hydrophilic-hydrophobic random copolymer membrane. The hydrophilic-hydrophobic random copolymer membrane includes a hydrophilic-hydrophobic random copolymer. The hydrophilic-hydrophobic random copolymer includes one or more hydrophilic monomers having a sulfonated polyarylsulfone monomer and a second monomer and one or more hydrophobic monomers having a non-sulfonated third monomer and a fourth monomer. The sulfonated polyarylsulfone monomer introduces a sulfonate into the hydrophilic-hydrophobic random copolymer prior to polymerization.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.