Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Curved detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A ten-day observation of Hercules X-1 from the OSO-7 satellite

The MIT X-ray detectors aboard the OSO-7 spacecraft viewed Hercules X-1 from November 14 to 24, 1972. X-ray turn-on in the 35-day cycle was observed to occur between phases 0.67 and 0.70 (November 18.64-18.70). A significant decrease in the X-ray intensity occurred near mid-orbital phase, approximately 1.5 days after X-ray turn-on. Using the 1-6 keV data obtained during the 35-day off state, we conclude that if the optical light curve is due to heating of the large star by a blackbody source of soft X-rays, then the source must be large (radius greater than 5,000 km) and cool (temperature (kT) less than 90 eV). During one eclipse period (November 20.8-21.0) we find evidence for 1-6 keV X-ray emission.

Mcclintock, J. E.↗

Leveraging differentiable programming in the inverse problem of neutron stars

Neutron stars (NSs) probe the high-density regime of the nuclear equation of state (EOS). However, inferring the EOS from observations of NSs is a computationally challenging task. Here, in this work, we efficiently solve this inverse problem by leveraging differential programming in two ways. First, we enable full Bayesian inference in under one hour of wall time on a GPU by using gradient-based samplers, without requiring pretrained machine learning emulators. Moreover, we demonstrate efficient scaling to high-dimensional parameter spaces. Second, we introduce a novel gradient-based optimization scheme that recovers the EOS of a given NS mass-radius curve. We demonstrate how our framework can reveal consistencies or tensions between nuclear physics and astrophysics. First, we show how the breakdown density of a metamodel description of the EOS can be determined from NS observations. Second, we demonstrate how degeneracies in EOS modeling using nuclear empirical parameters can influence the inverse problem during gradient-based optimization. Looking ahead, our approach opens up new theoretical studies of the relation between NS properties and the EOS, while effectively tackling the data analysis challenges brought by future detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the Design of Wide-Field X-ray Telescopes

X-ray telescopes having a relatively wide field-of-view and spatial resolution vs. polar off-axis angle curves much flatter than the parabolic dependence characteristic of Wolter I designs are of great interest for surveys of the X-ray sky and potentially for study of the Sun s X-ray emission. We discuss the various considerations affecting the design of such telescopes, including the possible use of polynomial mirror surface prescriptions, a method of optimizing the polynomial coefficients, scaling laws for mirror segment length vs. intersection radius, the loss of on-axis spatial resolution, and the positioning of focal plane detectors.

Elsner, Ronald F.↗

Spectral Characterizations of the Clouds and the Earth's Radiant Energy System (CERES) Thermistor Bolometers using Fourier Transform Spectrometer (FTS) Techniques

Fourier Transform Spectrometer (FTS) techniques are being used to characterize the relative spectral response, or sensitivity, of scanning thermistor bolometers in the infrared (IR) region (2 - >= 100-micrometers). The bolometers are being used in the Clouds and the Earth's Radiant Energy System (CERES) program. The CERES measurements are designed to provide precise, long term monitoring of the Earth's atmospheric radiation energy budget. The CERES instrument houses three bolometric radiometers, a total wavelength (0.3- >= 150-micrometers) sensor, a shortwave (0.3-5-micrometers) sensor, and an atmospheric window (8-12-micrometers) sensor. Accurate spectral characterization is necessary for determining filtered radiances for longwave radiometric calibrations. The CERES bolometers spectral response's are measured in the TRW FTS Vacuum Chamber Facility (FTS - VCF), which uses a FTS as the source and a cavity pyroelectric trap detector as the reference. The CERES bolometers and the cavity detector are contained in a vacuum chamber, while the FTS source is housed in a GN2 purged chamber. Due to the thermal time constant of the CERES bolometers, the FTS must be operated in a step mode. Data are acquired in 6 IR spectral bands covering the entire longwave IR region. In this paper, the TRW spectral calibration facility design and data measurement techniques are described. Two approaches are presented which convert the total channel FTS data into the final CERES spectral characterizations, producing the same calibration coefficients (within 0.1 percent). The resulting spectral response curves are shown, along with error sources in the two procedures. Finally, the impact of each spectral response curve on CERES data validation will be examined through analysis of filtered radiance values from various typical scene types.

Thornhill, K. Lee↗

Recurrent brief X-ray bursts from the globular cluster NGC 6624

Observational data are presented on ten brief X-ray bursts, recurrent at nearly equal time intervals, recorded during a two-day observation of 3U 1820-30 in the globular cluster NGC 6624 with the wide-field modulation collimator detectors on the SAS-3 X-ray observatory. The occurrence times were fitted by least squares to a linear sequence with an rms deviation of 621 sec, corresponding to a phase jitter of 3.9%. The bursts were observed in two energy channels. For a sequence of five of the most clearly observed bursts, the 2-6 keV rate rose to its peak value in about 1 sec and then decayed to preburst level in about 10 sec. The 6-11 keV rate rose more slowly and decayed similarly. The smooth decay of their averaged light curve suggests the temporal evolution may have a geometrical origin, where Compton scattering in a surrounding cloud of hot plasma stretches the pulse out and causes a progressive hardening of the spectrum.

Clark, G. W.↗

Liquid-vapour surface sensors for liquid nitrogen and hydrogen

The present paper identifies devices to serve as liquid-vapor detectors in zero gravity. The testing in LH2 was done in a sealed glass Dewar system to eliminate any chance of mixing H2 and air. Most of the tests were performed with the leads to the sensor horizontal. Some results of rapid cycle testing of LVDG in LH2 are presented. Findings of rapid-cycle testing of LVDG in LH2 are discussed. The sensor crossed the liquid surface when the position sensor registered 1.9 V, which occurred at about 0.4075 s. The delay time was about 1.5 ms. From the estimated slope of the position sensor curve at 1.9 V, the velocity of the sensor through the liquid surface is over 3 m/s. Results of tests of optical sensors are presented as well.

Siegwarth, J. D.↗

WaFIRS, a Waveguide Far-IR Spectrometer: Enabling Space-Borne Spectroscopy of High-z Galaxies in the Far-IR and Submm

The discovery of galaxies beyond z approximately equal to 1 which emit the bulk of their luminosity at long wavelengths has demonstrated the need for high sensitivity, broadband spectroscopy in the far-IR/submm/mm bands. Because many of these sources are not detectable in the optical, long wavelength spectroscopy is key to measuring their redshifts and ISM conditions. The continuum source list will increase in the next decade with new ground-based instruments (SCUBA2, Bolocam, MAMBO) and the surveys of HSO and SIRTF. Yet the planned spectroscopic capabilities lag behind, primarily due to the difficulty in scaling existing IR spectrograph designs to longer wavelengths. To overcome these limitations, we are developing WaFIRS, a novel concept for long-wavelength spectroscopy which utilizes a parallel-plate waveguide and a curved diffraction grating. WaFIRS provides the large (approximately 60%) instantaneous bandwidth and high throughput of a conventional grating system, but offers a dramatic reduction in volume and mass. WaFIRS requires no space overheads for extra optical elements beyond the diffraction grating itself, and is two-dimensional because the propagation is confined between two parallel plates. Thus several modules could be stacked to multiplex either spatially or in different frequency bands. The size and mass savings provide opportunities for spectroscopy from space-borne observatories which would be impractical with conventional spectrographs. With background-limited detectors and a cooled 3.5 telescope, the line sensitivity would be better than that of ALMA, with instantaneous broad-band coverage. We have built and tested a WaFIRS prototype for 1-1.6 mm, and are currently constructing Z-Spec, a 100 mK model to be used as a ground-based lambda/DELTAlambda approximately equal to 350 submillimeter galaxy redshift machine.

Bradford, C. M.↗

Results of the asteroid-meteoroid particle experiment on Pioneer 11

The Asteroid-Meteoroid Detector, an electro-optical instrument that detects and measures particles in space by sensing the sunlight reflected from them, is part of the payload of both the Pioneer 10 and 11 spacecraft. The Pioneer 11 instrument is essentially identical to that on Pioneer 10, with some minor modifications. Reduction of the Pioneer 11 data was complicated by the failure of one of the four sensor channels at about 1.1 AU from the sun. Detailed analysis yielded 51 events between 1.0 and 3.5 AU, which were used to determine the particle concentration distribution in that region of space. Weighted curve-fitting of the results shows agreement with the concentrations derived from Pioneer 10 to within about a factor of two. As with the Pioneer 10 results, the exponent of the size dependency varies from about -1.7 for 100-micron radius particles to about -3.2 for 10-cm bodies. The instrument, its operation, and the method of data analysis are reviewed.

Soberman, R. K.↗

Type 3 solar radio bursts

Using low frequency satellite observations, a direct comparison of the different theories is possible of the structure of the interplanetary medium. Measurements were made by satellite electron detectors in the same region of the interplanetary media where rapid drift type 3 solar radio bursts are generated. Results show, on the basis of this comparison, the general inadequacies of current type 3 burst theories and indicate a needed emphasis on formulating a new theory that is consistent with the low frequency observations. Representative observations from the RAE satellite are shown. The brightness temperature, which is a measure of the energy flux, versus frequency was plotted. Two events, a large burst and a large storm are also shown, each recorded at frequencies of 2.8 MHz and 700 KHz. High frequency curves obtained from ground-based observations are given.

Evans, L. G.↗

First Searches for Optical Counterparts to Gravitational-Wave Candidate Events

During the Laser Interferometer Gravitational-wave Observatory and Virgo joint science runs in 2009-2010, gravitational wave (GW) data from three interferometer detectors were analyzed within minutes to select GW candidate events and infer their apparent sky positions. Target coordinates were transmitted to several telescopes for follow-up observations aimed at the detection of an associated optical transient. Images were obtained for eight such GW candidates. We present the methods used to analyze the image data as well as the transient search results. No optical transient was identified with a convincing association with any of these candidates, and none of the GW triggers showed strong evidence for being astrophysical in nature. We compare the sensitivities of these observations to several model light curves from possible sources of interest, and discuss prospects for future joint GW-optical observations of this type.

gravitational waves↗

The MIT/OSO 7 catalog of X-ray sources - Intensities, spectra, and long-term variability

This paper is a summary of the observations of the cosmic X-ray sky performed by the MIT 1-40-keV X-ray detectors on OSO 7 between October 1971 and May 1973. Specifically, mean intensities or upper limits of all third Uhuru or OSO 7 cataloged sources (185 sources) in the 3-10-keV range are computed. For those sources for which a statistically significant (greater than 20) intensity was found in the 3-10-keV band (138 sources), further intensity determinations were made in the 1-15-keV, 1-6-keV, and 15-40-keV energy bands. Graphs and other simple techniques are provided to aid the user in converting the observed counting rates to convenient units and in determining spectral parameters. Long-term light curves (counting rates in one or more energy bands as a function of time) are plotted for 86 of the brighter sources.

Markert, T. H.↗

High energy primary electron spectrum observed by the emulsion chamber

A detector of the emulsion chamber type is used to measure the energy spectrum of cosmic-ray electrons. Two large emulsion chambers, each having an area of 40 by 50 sq cm, are exposed for about 25.5 hr at an average pressure altitude of 3.9 mbar. About 500 high-energy cascades (no less than about 600 GeV) are detected by searching for dark spots on the X-ray films. A power-law energy dependence formula is derived for the spectrum of primary cosmic-ray electrons in the energy region over 100 GeV. The results are in good agreement with the transition curves obtained previously by theoretical and Monte Carlo calculations.

Nishimura, J.↗

The NASA Spacecraft Transponding Modem

A new deep space transponder is being developed by the Jet Propulsion Laboratory for NASA. The Spacecraft Transponding Modem (STM) implements the standard transponder functions and the channel service functions that have previously resided in spacecraft Command/Data Subsystems. The STM uses custom ASICs, MMICs, and MCMs to reduce the active device parts count to 70, mass to I kg, and volume to 524 cc. The first STMs will be flown on missions launching in the 2003 time frame. The STM tracks an X-band uplink signal and provides both X-band and Ka-band downlinks, either coherent or non-coherent with the uplink. A NASA standard Command Detector Unit is integrated into the STM, along with a codeblock processor and a hardware command decoder. The decoded command codeblocks are output to the spacecraft command/data subsystem. Virtual Channel 0 (VC-0) (hardware) commands are processed and output as critical controller (CRC) commands. Downlink telemetry is received from the spacecraft data subsystem as telemetry frames. The STM provides the following downlink coding options: the standard CCSDS (7-1/2) convolutional coding, ReedSolomon coding with interleave depths one and five, (15-1/6) convolutional coding, and Turbo coding with rates 1/3 and 1/6. The downlink symbol rates can be linearly ramped to match the G/T curve of the receiving station, providing up to a 1 dB increase in data return. Data rates range from 5 bits per second (bps) to 24 Mbps, with three modulation modes provided: modulated subcarrier (3 different frequencies provided), biphase-L modulated direct on carrier, and Offset QPSK. Also, the capability to generate one of four non-harmonically related telemetry beacon tones is provided, to allow for a simple spacecraft status monitoring scheme for cruise phases of missions. Three ranging modes are provided: standard turn around ranging, regenerative pseudo-noise (PN) ranging, and Differential One-way Ranging (DOR) tones. The regenerative ranging provides the capability of increasing the ground received ranging SNR by up to 30 dB. Two different avionics interfaces to the command/data subsystem's data bus are provided: a MIL STD 1553B bus or an industry standard PCI interface. Digital interfaces provide the capability to control antenna selection (e.g., switching between high gain and low gain antennas) and antenna pointing (for future steered Ka-band antennas).

Berner, Jeff B.↗

Deuterated Xylene-Based Neutron Spectrometry

Deuterated scintillators, such as deuterated xylene (C8D10) have been theorized to offer better pulse shape discrimination (PSD) and neutron spectrometry performance than traditional protiated scintillators due to the anisotropy of neutron scattering on deuterium. However, the light output responses of said deuterated scintillators to monoenergetic has not been characterized in its entirety at both high and low energies. Several time-of-flight experiments were conducted at the Idaho national Laboratory to characterize a pair of EJ-301D deuterated xylene detectors. The low energy detector response to quasi-monoenergetic neutrons was measured using a Cf-252 source, and the high energy detector response was measured using a D-T source and angles of 20, 45, and 60 deg, corresponding to theoretical neutron energies of 13.2, 10.4, and 8.2 MeV. During post-processing, the neutron and gamma bands were clearly able to be separated, even at low light outputs, solidifying the superior PSD capability of deuterated xylene. An exponential of fit of LO=0.63E-2.22*(1-exp(-0.25E)), which has good agreement with previously measured data, was found as the light output response from deuteron recoils. Additionally, measurements of AmBe, D-T, and D-D sources were unfolded using the light output response curve, which resulted in favorable agreement with theoretical values. Further testing of the response matrix by unfolding more sources (such as PuBe) needs to be done, but the unfolding accuracy for currently available sources suggests that deuterated xylene can be used to measure and unfold both fission, monoenergetic, and continuous spectra.

scintillator↗

Inferring Water Content from Neutron Die-away Curves for Planetary Science Applications

Signatures of liquid water on planetary bodies may provide evidence for past, present, or future life elsewhere in the solar system. Multiple current and upcoming planetary science missions are prioritizing the search for water, using innovative technologies and creative algorithms. For this project, we explore the capabilities of an instrument similar to the Dragonfly spacecraft to map water content on the surface of Titan, the largest moon of Saturn. We simulate Dragonfly’s neutron observations for a variety of soil compositions and develop multiple techniques to extract water content from the resultant neutron data. Additionally, we supplement neutron observations with gamma spectroscopy in an attempt to further refine water content estimates. This work is part of a larger study to employ Gaussian process regression to estimate a map of water content along the surface of Titan. Using the estimated map, an algorithm based on prediction difference mapping is employed to optimally move multiple Dragonfly detectors around the surface of Titan, fully autonomously.

79 ASTRONOMY AND ASTROPHYSICS↗

Diurnal Lightning Distribution as Observed by the Optical Transient Detector (OTD)

Since April 1995, lightning activity around the globe has been monitored with the Optical Transient Detector (OTD). The OTD observations acquired during the one year period from September 1995 through August 1996 have been used to statistically determine the number of flashes that occur over the Earth during each hour of the diurnal cycle, expressed both as a function of local time and universal time. The globally averaged local [il,htnina activity displays a peak in late afternoon (1500-1800 local time) and a minimum in the morning hours (0600- 1000 local time) consistent with convection associated with diurnal heating. No diurnal variation is found for oceanic storms. The diurnal lightning distribution (universal time) for the globe displays a variation of about 35% about its mean as compared to the Carnegie curve which has a variation of only 15% above and below the mean.

Blakeslee, Richard J.↗

Dose Calibration of the ISS-RAD Fast Neutron Detector

The ISS-RAD instrument has been fabricated by Southwest Research Institute and delivered to NASA for flight to the ISS in late 2015 or early 2016. ISS-RAD is essentially two instruments that share a common interface to ISS. The two instruments are the Charged Particle Detector (CPD), which is very similar to the MSL-RAD detector on Mars, and the Fast Neutron Detector (FND), which is a boron-loaded plastic scintillator with readout optimized for the 0.5 to 10 MeV energy range. As the FND is completely new, it has been necessary to develop methodology to allow it to be used to measure the neutron dose and dose equivalent. This talk will focus on the methods developed and their implementation using calibration data obtained in quasi-monoenergetic (QMN) neutron fields at the PTB facility in Braunschweig, Germany. The QMN data allow us to determine an approximate response function, from which we estimate dose and dose equivalent contributions per detected neutron as a function of the pulse height. We refer to these as the "pSv per count" curves for dose equivalent and the "pGy per count" curves for dose. The FND is required to provide a dose equivalent measurement with an accuracy of 10% of the known value in a calibrated AmBe field. Four variants of the analysis method were developed, corresponding to two different approximations of the pSv per count curve, and two different implementations, one for real-time analysis onboard ISS and one for ground analysis. We will show that the preferred method, when applied in either real-time or ground analysis, yields good accuracy for the AmBe field. We find that the real-time algorithm is more susceptible to chance-coincidence background than is the algorithm used in ground analysis, so that the best estimates will come from the latter.

Zeitlin, C.↗