Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Observation of time-dependent internal charge amplification in a planar germanium detector at cryogenic temperature

For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 min after applying a bias voltage, the charge energy corresponding to a baseline of the 59.54 keVγ rays from a 241 Am source is amplified for a short period of time and then decreases back to the baseline. The amplification of charge energy depends strongly on the applied positive bias voltage with drifting holes across the detector. No such phenomenon is visible with drifting electrons across the detector. We find that the observed charge amplification is dictated by the impact ionization of charged states, which has a strong correlation with impurity level and applied electric field. We analyze the dominant physics mechanisms that are responsible for the creation and the impact ionization of charged states. Our analysis suggests that the appropriate level of impurity in a Ge detector can enhance charge yield through the impact ionization of charged states to achieve extremely low-energy detection threshold (< 10 meV) for MeV-scale dark matter searches if the charge amplification can be stabilized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving the performance of cryogenic calorimeters with nonlinear multivariate noise cancellation algorithms

Abstract State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical interference or microphonics. The sources of this environmental noise can often be monitored by adding specially designed “auxiliary devices” (e.g. microphones, accelerometers, seismometers, magnetometers, and antennae). A model can then be constructed to predict the detector noise based on the auxiliary device information, which can then be subtracted from the true detector signal. Here, we present a multivariate noise cancellation algorithm which can be used in a variety of settings to improve the performance of detectors using multiple auxiliary devices. To validate this approach, we apply it to simulated data to remove noise due to electromagnetic interference and microphonic vibrations. We then employ the algorithm to a cryogenic light detector in the laboratory and show an improvement in the detector performance. Finally, we motivate the use of nonlinear terms to better model vibrational contributions to the noise in thermal detectors. We show a further improvement in the performance of a particular channel of the CUORE detector when using the nonlinear algorithm in combination with optimal filtering techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband, millimeter-wave antireflection coatings for large-format, cryogenic aluminum oxide optics

Here, we present two prescriptions for broadband (~77 -252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano–convex elements, the other for densely packed arrays of quasi-optical elements—in our case, 5 mm diameter half-spheres (called “lenslets”). The coatings comprise three layers of commercially available, polytetrafluoroethylene-based, dielectric sheet material. The lenslet coating is molded to fit the 150 mm diameter arrays directly, while the large-diameter lenses are coated using a tiled approach. We review the fabrication processes for both prescriptions, then discuss laboratory measurements of their transmittance and reflectance. In addition, we present the inferred refractive indices and loss tangents for the coating materials and the aluminum oxide substrate. We find that at 150 GHz and 300 K the large-format coating sample achieves (97±2)% transmittance, and the lenslet coating sample achieves (94±3)% transmittance.

36 MATERIALS SCIENCE↗

Anti-reflection coating with mullite and Duroid for large-diameter cryogenic sapphire and alumina optics

We developed a broadband two-layer anti-reflection (AR) coating for use on a sapphire half-wave plate (HWP) and an alumina infrared (IR) filter for the cosmic microwave background (CMB) polarimetry. Measuring the faint CMB B-mode signals requires maximizing the number of photons reaching the detectors and minimizing spurious polarization due to reflection with an off-axis incident angle. Sapphire and alumina have high refractive indices of 3.1 and are highly reflective without an AR coating. This paper presents the design, fabrication, quality control, and measured performance of an AR coating using thermally sprayed mullite and Duroid 5880LZ. This technology enables large optical elements with diameters of 600 mm. We also present a thermography-based nondestructive quality control technique, which is key to assuring good adhesion and preventing delamination when thermal cycling. We demonstrate the average reflectance of about 2.6% (0.9%) for two observing bands centered at 90/150 (220/280) GHz. At room temperature, the average transmittance of a 105 mm square test sample at 220/280 GHz is 83%, and it will increase to 90% at 100 K, attributed to reduced absorption losses. Therefore, our developed layering technique has proved effective for 220/280 GHz applications, particularly in addressing dielectric loss concerns. This AR coating technology has been deployed in the cryogenic HWP and IR filters of the Simons Array and the Simons observatory experiments and applies to future experiments such as CMB-S4.

Sakaguri, Kana (ORCID:0000000156678118)↗

Cryogenic C-band wavelength division multiplexing system using an AIM Photonics Foundry process design kit

Cryogenic environments make superconducting computing possible by reducing thermal noise, electrical resistance and heat dissipation. Heat generated by the electronics and thermal conductivity of electrical transmission lines to the outside world constitute two main sources of thermal load in such systems. As a result, higher data rates require additional transmission lines which come at an increasingly higher cooling power cost. Hybrid or monolithic integration of silicon photonics with the electronics can be the key to higher data rates and lower power costs in these systems. We present a 4-channel wavelength division multiplexing photonic integrated circuit (PIC) built from modulators in the AIM Photonics process development kit (PDK) that operate at 25 Gbps at room temperature and 10 Gbps at 40 K. We further demonstrate 2-channel operation for 20 Gbps aggregate data rate at 40 K using two different modulators/wavelengths, with the potential for higher aggregate bit rates by utilizing additional channels.

42 ENGINEERING↗

Photorefraction-induced Bragg scattering in cryogenic lithium niobate ring resonators

We report intracavity Bragg scattering induced by the photorefractive (PR) effect in high-Q lithium niobate ring resonators at cryogenic temperatures. We show that when a cavity mode is strongly excited, the PR effect imprints a long-lived periodic space-charge field. This residual field in turn creates a refractive index modulation pattern that dramatically enhances the back scattering of an incoming probe light, and results in selective and reconfigurable mode splittings. This PR-induced Bragg scattering effect, despite being undesired for many applications, could be utilized to enable optically programmable photonic components.

42 ENGINEERING↗

Soft matter and nanomaterials characterization by cryogenic transmission electron microscopy

Soft matter has historically been an unlikely candidate for investigation by electron microscopy techniques due to damage by the electron beam as well as inherent instability under a high vacuum environment. Characterization of soft matter has often relied on ensemble-scattering techniques. The recent development of cryogenic transmission electron microscopy (cryo-TEM) provides the soft matter community with an exciting opportunity to probe the structure of soft materials in real space. Cryo-TEM reduces beam damage and allows for characterization in a native, frozen-hydrated state, providing direct visual representation of soft structure. This article reviews cryo-TEM in soft materials characterization and illustrates how it has provided unique insights not possible by traditional ensemble techniques. Soft matter systems that have benefited from the use of cryo-TEM include biological-based “soft” nanoparticles (e.g., viruses and conjugates), synthetic polymers, supramolecular materials as well as the organic–inorganic interface of colloidal nanoparticles. We conclude that while many challenges remain, such as combining structural and chemical analyses; the opportunity for soft matter research to leverage newly developed cryo-TEM techniques continues to excite.

36 MATERIALS SCIENCE↗

Atomic-scale cryogenic electron microscopy imaging of self-assembled peptoid nanostructures

Amphiphilic polypeptoids with defined sequences, versatile in forming various nanostructures, are ideal for mimicking biomacromolecular structures. The predictive design of nanostructures depends on our understanding of the relationship between molecular structure and the locations of atoms in the nanostructure. Factors of importance include chain conformation, crystal motifs, and the arrangement of the molecules within the nanostructure. Here, this review introduces the cryogenic transmission electron microscopy (cryo-TEM) method, sorting and averaging unit cells in nanosheets for resolution enhancement and identifying structural heterogeneity. The resulting atomic-scale images reveal the presence of two types of crystal motifs. The impact of processing conditions, capping group chemistry, and side chain chemistry on structural heterogeneity and crystal motifs can be quantified. The 3D reconstruction of nanosheets, wherein atomic-scale corrugations were revealed, is introduced in this review. New developments in cryo-TEM, such as phase retrieval reconstruction, hold great promise for atomic-scale imaging of soft nanostructures.

36 MATERIALS SCIENCE↗

Argonaut - A Robotic System for Cryogenic Environments

Fermilab and the HEP community invest significant resources into liquid argon detectors. The largest and most expensive of these detectors will be located in the Deep Underground Neutrino Experiment (DUNE). However, recent experiences have shown that there are limited avenues of monitoring, intervention, and interaction in the internal liquid environment. This proposal shows a technological path that could provide a valuable tool to ensure or at least improve the management of these HEP detectors. The development of a robotic system named Argonaut will demonstrate several technologies including 1) demonstration of suitable mobility of a small robotic device at liquid argon temperatures, 2) demonstration of wireless communication, 3) demonstration of improved diagnostics capabilities - such as tunable optics with motion control, 4) demonstration of interconnectivity of a robotic system with hardware residing within the detector. This initial research will be a seed for extended development in cold robotics and associated technologies. This work will allow FNAL to contribute a significant technology capability to recent efforts to cryogenic detector operations.

43 PARTICLE ACCELERATORS↗

Detectors and beam monitors based on wide bandgap semiconductors at cryogenic temperatures

Wide-bandgap semiconductors, such as single-crystal diamond and sapphire, can be used to measure the flux of passing particles through a particle-induced conductivity effect. We recently demonstrated a diamond-based, electrodeless electron beam halo monitor. This monitor utilized a thin diamond blade placed within an open, high-quality microwave resonator. The blade partially intercepted the beam and changes in the RF properties of the resonator were used to infer beam parameters. To enhance the sensitivity of our semiconductor sensors, we propose two new techniques: (1) biasing the semiconductor sensor to support avalanche multiplication of free carriers, and (2) operating at cryogenic temperatures to reduce intrinsic semiconductor losses and increase the mobility of induced carriers. These techniques are applicable not only to particle beam diagnostics but also to the detection of various types of ionizing radiation.

Accelerator Physics↗

Thermal Conductivity of Electroplated Copper Onto Bulk Niobium at Cryogenic Temperatures

Superconducting radio-frequency (SRF) cavities made of high-purity bulk niobium are widely used in modern particle accelerators. The development of metallic outer coatings with high thermal conductivity would have a beneficial impact in terms of improved thermal stability, reduced material cost and for the development of conduction-cooled, cryogen-free SRF cavities. Several high-purity, fine-grain Nb samples have been coated with 2-4 mm thick copper by electroplating. Measurements of the thermal conductivity of the bimetallic Nb/Cu samples in the range 2 ? 7 K showed values of the order of 1 kW/(m K) at 4.3 K. Very good adhesion between copper and niobium was achieved by depositing a thin Cu layer by cold spray on the niobium, prior to electroplating the bulk Cu layer.

Dhakal, P.↗

Development of an Advanced Hydrogen Energy Storage System using Aerogel in a Cryogenic Flux Capacitor (CFC)

The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature, high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, is constructed from readily available commercial materials, lends itself to a range of pressure applications, and is geometry insensitive. They can also be used in modular designs, affording even more flexibility for potential deployment. In addition to the aerogel adsorbent within the blanket material, a CFC includes thermally-conductive membrane layered with the aerogel, which acts as a large-area, quick-response thermal management system. The system conducts heat throughout the volume to discharge the unit quickly. This same thermal management system can also be connected to a refrigeration system, or cold fluid such as liquid nitrogen (LN2), to facilitate the charging up of the CFC. The charging and discharging can be performed as fast or as slow as desired by controlling the cooling or heating supplied to the CFC.

08 HYDROGEN↗

Tunable Permanent Magnet Quadrupole Operating at Cryogenic Temperatures for Accelerators

The project objective is to develop a compact and tunable quadrupole using Electron Energy Corporation (EEC)’s PM materials for cryogenic accelerator applications. To achieve this objective, EEC and SLAC National Accelerator Laboratory (SLAC) will collaborate to develop a cost-effective quadrupole and optimize the conventional manufacturing process. Based on previous experience, EEC designed an innovative field adjustment capability using tuning magnets which is able to achieve all the requirements for SLAC’s cold copper collider (C3 ) application. These novel ideas enable us to develop a compact and tunable quadrupole magnet superior to the current designs. Our approach is to leverage EEC's over 50 years of experience in magnet manufacturing and SLAC’s beamline test capabilities.

42 ENGINEERING↗

A multi-channel cryogenic low-noise skipper-CCD readout ASIC

• Skipper CCDs provide exceptionally low noise useful for dark matter detection• MIDNA ASIC enables scaled cryogenic Skipper CCD readout• Noise performance proven to specification at room temperature with CCD• Liquid nitrogen measurements show functionality with more to come• Future development will integrate more sensitive signals and averaging capability

England, Troy↗

Thermal Conductivity of Electroplated Copper Onto Bulk Niobium at Cryogenic Temperatures

Superconducting radio-frequency (SRF) cavities made of high-purity bulk niobium are widely used in modern particle accelerators. The development of metallic outer coatings with high thermal conductivity would have a beneficial impact in terms of improved thermal stability, reduced material cost and for the development of conduction-cooled, cryogen-free SRF cavities. Several high-purity, fine-grain Nb samples have been coated with 2-4 mm thick copper by electroplating. Measurements of the thermal conductivity of the bimetallic Nb/Cu samples in the range 2 ? 7 K showed values of the order of 1 kW/(m K) at 4.3 K. Very good adhesion between copper and niobium was achieved by depositing a thin Cu layer by cold spray on the niobium, prior to electroplating the bulk Cu layer.

Dhakal, P.↗

Project Report: High Frequency Axion LDRD - A Multiport Approach to Thermal Noise and Scattering Parameter Simulation of Cryogenic Experiments

In this report, a simple algorithm for detailed system-level thermal noise analysis is developed, demonstrated, and verified. This method uses noise-wave theory and noise covariance matrices to cascade noise and scattering parameters of multiport devices at different temperatures. This method addresses the effects of return loss, multiport isolation/coupling, and static temperature differentials between components, and will work in cases where the noise temperature is at or near the quantum noise limit. An ideal multidevice network will first be demonstrated to show that this method’s results are consistent with the Friis cascade when component parameters such as return loss and isolation are ideal. Following the ideal multidevice example, a cryogenic experiment is conducted to demonstrate that the proposed simulation method is successful when real data are used.

42 ENGINEERING↗