Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Unraveling Joint Evolution of Bars, Star Formation, and Active Galactic Nuclei of Disk Galaxies

We aim to unravel the interplay between bars, star formation (SF), and active galactic nuclei (AGNs) in barred galaxies. To this end, we utilize the SDSS DR12 to select a sample of nearby (0.02 < z < 0.06) disk galaxies that are suitable for bar examination (M r < –20.12 and inclination ≲53°). We identify 3662 barred galaxies and measure the length and axis ratio of each bar. We invent new bar parameters that mitigate the stellar and bulge mass biases and show, for the first time, that the evolution of non-AGN and AGN-hosting barred galaxies should be tracked using different bar parameters: the bar length for non-AGN galaxies and the bar axis ratio for AGN-hosting galaxies. Our analysis confirms that barred galaxies have a higher specific SF rate than unbarred control galaxies. Moreover, we find a positive correlation of bar length with both the SF enhancement and the centrally star-forming galaxy fraction, indicating the interconnectivity of bars and SF through the bar-driven gas inflow. We also find that, while the AGN fraction of barred galaxies is the same as that of the unbarred control sample, galaxies hosting more massive black holes (BHs) have rounder (i.e., higher axis ratio) bars, implying that the bar is not a cause of AGN activity; rather, AGNs appear to regulate bars. Our findings corroborate theoretical predictions that bars in non-AGN galaxies grow in length, and bars in AGN-hosting galaxies become rounder as BHs grow and eventually get destroyed.

79 ASTRONOMY AND ASTROPHYSICS↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Ultraviolet+Infrared Star Formation Rates: Hickson Compact Groups with Swift and SPitzer

We present Swift UVOT ultraviolet (UV; 1600-3000 A) data with complete three-band UV photometry for a sample of 41 galaxies in 11 nearby (<4500 km/s) Hickson Compact Groups (HCGs) of galaxies. We use UVOT uvw2-band (2000A) photometry to estimate the dust-unobscured component, SFR(sub uv), of the total star formation rate, SFR(sub TOTAL). We use Spitzer MIPS 24 micron photometry to estimate SFR(sub IR), the component of SFR(sub TOTAL) that suffers dust extinction in the UV and is re-emitted in the IR. By combining the two components, we obtain SFR(sub TOTAL) estimates for all HCG galaxies. We obtain total stellar mass, M(sub *) estimates by means of Two Micron All Sky Survey K(sub s)-band luminosities, and use them to calculate specific star formation rates, SSFR is identical with SFR(sub TOTAL)/ M (sub *). SSFR values show a clear and significant bimodality, with a gap between low (approximately <3.2 x 10(exp -11) / yr) and high-SSFR (approximately > 1.2 x lO)exp -10)/yr) systems. We compare this bimodality to the previously discovered bimodality in alpha-IRAC, the MIR activity index from a power-law fit to the Spitzer IRAC 4.5-8 micron data for these galaxies. We find that all galaxies with alpha-IRAC <= 0 (> 0) are in the high- (low-) SSFR locus, as expected if high levels of star-forming activity power MIR emission from polycyclic aromatic hydrocarbon molecules and a hot dust continuum. Consistent with this finding, all elliptical/SO galaxies are in the low-SSFR locus, while 22 out of 24 spirals / irregulars are in the high-SSFR locus, with two borderline cases. We further divide our sample into three subsamples (I, II, and III) according to decreasing H I richness of the parent galaxy group to which a galaxy belongs. Consistent with the SSFR and alpha-IRAC bimodality, 12 out of 15 type I (11 out of 12 type III) galaxies are in the high- (low-) SSFR locus, while type II galaxies span almost the full range of SSFR values. We use the Spitzer Infrared Nearby Galaxy Survey (SINGS) to construct a comparison subsample of galaxies that (1) match HCG galaxies in J-band total galaxy luminosity and (2) are not strongly interacting and largely isolated. This selection eliminates mostly low-luminosity dwarfs and galaxies with some degree of peculiarity, providing a substantially improved, quiescent control sample. Unlike HCG galaxies, galaxies in the comparison SINGS subsample are continuously distributed both in SSFR and alpha-IRAC, although they show ranges in SFR(sub TOTAL) values, morphologies and stellar masses similar to those for HCG systems. We test the SSFR bimodality against a number of uncertainties, and find that these can only lead to its further enhancement. Excluding galaxies belonging to HCGs with three giant galaxies (triplets) leaves both the SSFR and the alpha-IRAC bimodality completely unaffected. We interpret these results as further evidence that an environment characterized by high galaxy number densities and low galaxy velocity dispersions, such as the one found in compact groups, plays a key role in accelerating galaxy evolution by enhancing star formation processes in galaxies and favoring a fast transition to quiescence.

Tzanavaris, P.↗

Galaxies with biconical ionized structure in MaNGA – I. Sample selection and driven mechanisms

ABSTRACT Based on the integral field unit (IFU) data from Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey, we develop a new method to select galaxies with biconical ionized structures, building a sample of 142 edge-on biconical ionized galaxies. We classify these 142 galaxies into 81 star-forming galaxies, 31 composite galaxies, and 30 AGNs (consisting of 23 Seyferts and 7 LI(N)ERs) according to the [N ii]-BPT diagram. The star-forming bicones have bar-like structures while AGN bicones display hourglass structures, and composite bicones exhibit transitional morphologies between them due to both black hole and star formation activities. Star-forming bicones have intense star formation activities in their central regions, and the primary driver of biconical structures is the central star formation rate surface density. The lack of difference in the strength of central black hole activities (traced by dust attenuation corrected [O iii]λ5007 luminosity and Eddington ratio) between Seyfert bicones and their control samples can be naturally explained as that the accretion disc and the galactic disc are not necessarily coplanar. Additionally, the biconical galaxies with central LI(N)ER-like line ratios are edge-on disc galaxies that show strong central dust attenuation. The radial gradients of H α surface brightness follow the r−2.35 relation, roughly consistent with r−2 profile, which is expected in the case of photoionization by a central point-like source. These observations indicate obscured AGNs or AGN echoes as the primary drivers of biconical structures in LI(N)ERs.

Zhou, Zhi-Jie (ORCID:0000000317096005)↗

A study of the central stellar populations of galaxies in SDSS-IV MaNGA: identification of a subsample with unusually young and massive stars

ABSTRACT This paper describes a search for galaxy centres with clear indications of unusual stellar populations with an initial mass function flatter than Salpeter at high stellar masses. Out of a sample of 668 face-on galaxies with stellar masses in the range $10^{10}\!-\!10^{11} \, \mathrm{M}_{\odot }$, I identify 15 galaxies with young- to intermediate-age central stellar populations with unusual stellar population gradients in the inner regions of the galaxy. In these galaxies, the 4000-Å break is either flat or rising towards the centre of the galaxy, indicating that the central regions host evolved stars, but the H α equivalent width also rises steeply in the central regions. The ionization parameter [O iii]/[O ii] is typically low in these Galactic Centres, indicating that ionizing sources are stellar rather than AGN. Wolf–Rayet features characteristic of hot young stars are often found in the spectra and these also get progressively stronger at smaller galactocentric radii. These outliers are compared to a control sample of galaxies of similar mass with young inner stellar populations, but where the gradients in H α equivalent width and 4000-Å break follow each other more closely. The outliers exhibit central Wolf–Rayet red bump excesses much more frequently, they have higher central stellar and ionized gas metallicities, and they are also more frequently detected at 20-cm radio wavelengths. I highlight one outlier where the ionized gas is clearly being strongly perturbed and blown out either by massive stars after they explode as supernovae, or by energy injection from matter falling on to a black hole.

Kauffmann, Guinevere↗

Development and Experimental Evaluation of Passive Fuel Cell Thermal Control

To provide uniform cooling for a fuel cell stack, a cooling plate concept was evaluated. This concept utilized thin cooling plates to extract heat from the interior of a fuel cell stack and move this heat to a cooling manifold where it can be transferred to an external cooling fluid. The advantages of this cooling approach include a reduced number of ancillary components and the ability to directly utilize an external cooling fluid loop for cooling the fuel cell stack. A number of different types of cooling plates and manifolds were developed. The cooling plates consisted of two main types; a plate based on thermopyrolytic graphite (TPG) and a planar (or flat plate) heat pipe. The plates, along with solid metal control samples, were tested for both thermal and electrical conductivity. To transfer heat from the cooling plates to the cooling fluid, a number of manifold designs utilizing various materials were devised, constructed, and tested. A key aspect of the manifold was that it had to be electrically nonconductive so it would not short out the fuel cell stack during operation. Different manifold and cooling plate configurations were tested in a vacuum chamber to minimize convective heat losses. Cooling plates were placed in the grooves within the manifolds and heated with surface-mounted electric pad heaters. The plate temperature and its thermal distribution were recorded for all tested combinations of manifold cooling flow rates and heater power loads. This testing simulated the performance of the cooling plates and manifold within an operational fuel cell stack. Different types of control valves and control schemes were tested and evaluated based on their ability to maintain a constant temperature of the cooling plates. The control valves regulated the cooling fluid flow through the manifold, thereby controlling the heat flow to the cooling fluid. Through this work, a cooling plate and manifold system was developed that could maintain the cooling plates within a minimal temperature band with negligible thermal gradients over power profiles that would be experienced within an operating fuel cell stack.

Fuel Cells↗

Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS detector.

Wang, Zuwei↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

Unexpected Giant Microwave Conductivity in a Nominally Silent BiFeO 3 Domain Wall

Nanoelectronic devices based on ferroelectric domain walls (DWs), such as memories, transistors, and rectifiers, have been shown in recent years. Practical high-speed electronics, on the other hand, usually demand operation frequencies in the gigahertz (GHz) regime, where the effect of dipolar oscillation is important. Herein, an unexpected giant GHz conductivity on the order of 10 3 S m -1 is observed in certain BiFeO 3 DWs, which is about 100 000 times greater than the carrier-induced direct current (dc) conductivity of the same walls. Surprisingly, the nominal configuration of the DWs precludes the alternating current (ac) conduction under an excitation electric field perpendicular to the surface. Theoretical analysis reflects that the inclined DWs are stressed asymmetrically near the film surface, whereas the vertical walls in a control sample are not. The resultant imbalanced polarization profile can then couple to the out-of-plane microwave fields and induce power dissipation, which is confirmed by the phase-field modeling. Since the contributions from mobile-carrier conduction and bound-charge oscillation to the ac conductivity are equivalent in a microwave circuit, the research on local structural dynamics may open a new avenue to implement DW nano-devices for radio-frequency applications.

36 MATERIALS SCIENCE↗

Evaluation of Hybrid Perovskite Prototypes After 10-Month Space Flight on the International Space Station

Metal halide perovskites (MHPs) have emerged as a prominent new photovoltaic material combining a very competitive power conversion efficiency that rivals crystalline silicon with the added benefits of tunable properties for multijunction devices fabricated from solution which can yield high specific power. Perovskites have also demonstrated some of the lowest temperature coefficients and highest defect tolerance, which make them excellent candidates for aerospace applications. However, MHPs must demonstrate durability in space which presents different challenges than terrestrial operating environments. To decisively test the viability of perovskites being used in space, a perovskite thin film is positioned in low earth orbit for 10 months on the International Space Station, which was the first long-duration study of an MHP in space. Postflight high-resolution ultrafast spectroscopic characterization and comparison with control samples reveal that the flight sample exhibits superior photo-stability, no irreversible radiation damage, and a suppressed structural phase transition temperature by nearly 65 K, broadening the photovoltaic operational range. Further, significant photo-annealing of surface defects is shown following prolonged light-soaking postflight. Here these results emphasize that methylammonium lead iodide can be packaged adequately for space missions, affirming that space stressors can be managed as theorized.

14 SOLAR ENERGY↗

A comparative experimental study of the hygroscopic and mechanical behaviors of electrospun nanofiber membranes and solution–cast films of polybenzimidazole

This article reports a comparative experimental study of the hygroscopic and mechanical behaviors of electrospun polybenzimidazole (PBI) nanofiber membranes and solution-cast PBI films. As-electrospun nonwoven PBI nanofiber mats (with the nanofiber diameter of ~250 nm) were heat-pressed under controlled temperature, pressure and duration for the study; lab-made solution-cast PBI films and commercially available PBI films (the PBI Performance Product Inc., Charlotte, NC) were used as the control samples. Thermogravimetric and microtensile tests were utilized to characterize the hygroscopic (moisture absorption) and mechanical properties of the PBI nanofiber membranes at varying heat-pressing conditions, which were further compared to those of solution-cast PBI films. Experimental results indicated that the PBI nanofiber membranes carried slightly higher thermal stability and less hygroscopic properties than those of solution-cast PBI films. In addition, heat-pressing conditions significantly influenced the mechanical properties of the resulting PBI nanofiber membranes. The stiffness and tensile strength increase with increasing either the heat-pressing pressure or duration, and relevant mechanisms were explored. Here, the present study provides a rational understanding of the hygroscopic and mechanical behaviors of electrospun PBI nanofiber membranes and solution-cast PBI films that are beneficial to their reliable cutting-edge applications in high-temperature filtration, polymer electrolyte membranes (PEMs), etc.

25 ENERGY STORAGE↗

Isolation, Characterization, and Depolymerization of L -Cysteine Substituted Eucalyptus Lignin

Lignin condensation reactions are hard to avoid or control during separation, which is a deterrent to lignin isolation and post-conversation, especially for the full utilization of lignocelluloses. Selective protection of β-aryl ether linkages in the isolation process is crucial to lignin valorization. Herein, a two-step acid/alkali separation method assisted with l-cysteine for eucalyptus lignin separation is developed, and the isolated L -cysteine lignins (LCLs) are comprehensively characterized by 2D NMR, 31 P NMR, thioacidolysis, etc. Compared to the two-step control treatment, a much higher β-O-4 content is preserved without reducing the separation efficiency assisted by L -cysteine, which is also significantly higher than alkali lignin and kraft lignin. The results of hydrogenolysis show that LCLs generate a much higher monomer yield than that of control sample. Structural analysis of LCLs suggests that lignin condensation reaction, to some extent, is suppressed by adding L -cysteine during the two-step acid/alkali separation. Further, mechanistic studies using dimeric model compound reveals that L -cysteine may be the α-carbon protective agent in the two-step separation. The role of L -cysteine in the two-step lignin isolation method provides novel insights to the selective fractionation of lignin from biomass, especially for the full valorization of lignocellulosic biomass.

09 BIOMASS FUELS↗

A search for microscopic black holes, string balls, and sphalerons in proton-proton collisions at $\sqrt{s}=13$ TeV

A search for microscopic black holes, string balls, and electroweak sphalerons using proton-proton collisions at $\sqrt{s}=13$ TeV recorded with the CMS detector at the CERN LHC during the 2016–2018 data taking, and corresponding to an integrated luminosity of 138 fb −1 , is presented. Two search strategies based on control samples in data are used. Model-independent limits on the cross section of physics phenomena with multiple energetic jets, leptons, and photons are set using a method that relies on the shape invariance of the scalar sum of the transverse momenta of all objects in the event. Model-dependent limits on black hole and sphaleron production are set using a newly introduced method that has been developed for the identification of collider events with distinct kinematic features by separating them into classes based on phase space proximity. In the context of models with large extra dimensions, semiclassical black holes and string balls with masses below 8.4–11.4 TeV and 9.0–10.7 TeV, respectively, are excluded at 95% confidence level, significantly extending the reach beyond previous searches. Results of a dedicated search for electroweak sphalerons are used to derive an upper limit of 0.0034 at 95% confidence level on the fraction of quark-quark interactions, with a center-of-mass energy above the nominal sphaleron transition energy threshold of 9 TeV, that result in a sphaleron transition.

Beyond Standard Model↗

Search for top squarks in final states with many light-flavor jets and 0, 1, or 2 charged leptons in proton-proton collisions at $\sqrt{s}=13$ TeV

Several new physics models including versions of supersymmetry (SUSY) characterized by R-parity violation (RPV) or with additional hidden sectors predict the production of events with top quarks, low missing transverse momentum, and many additional quarks or gluons. The results of a search for top squarks decaying to two top quarks and six additional light-flavor quarks or gluons are reported. The search employs a novel machine learning method for background estimation from control samples in data using decorrelated discriminators. The search is performed using events with 0, 1, or 2 electrons or muons in conjunction with at least six jets. No requirement is placed on the magnitude of the missing transverse momentum. The result is based on a sample of proton-proton collisions at $\sqrt{s}=13$ TeV corresponding to 138 fb −1 of integrated luminosity collected with the CMS detector at the LHC in 2016–2018. With no statistically significant excess of events observed beyond the expected contributions from the standard model, the data are used to determine upper limits on the top squark pair production cross section in the frameworks of RPV and stealth SUSY. Models with top squark masses less than 700 (930) GeV are excluded at 95% confidence level for RPV (stealth) SUSY scenarios.

Hadron-Hadron Scattering↗

Efficient BiVO 4 /CoFeO x H y photoanodes using controlled annealing and conformal linear-sweep electrocatalyst photodeposition

Although monoclinic bismuth vanadate (BiVO 4 ) is a promising photoanode for solar water splitting, its practical use is hindered by imperfect photocurrent generation/collection, low photovoltage compared to the bandgap, and corrosion side reactions that limit durability. Here, we introduce a controlled-annealing sol–gel process for BiVO 4 thin-film photoanodes along with an optimized linear-sweep-voltammetry photodeposition of CoFeO x H y cocatalysts. The resulting BiVO 4 films annealed at 550 °C exhibited a photocurrent density of 4.1 mA/cm 2 at 1.23 V RHE under 1 sun AM 1.5G solar simulation and a low onset potential of 0.26 V RHE due to high majority carrier conductivity, a crystalline bulk with reduced defects as evidenced by x-ray photoelectron spectroscopy and photoluminescence lifetime analysis, and thus enhanced photocarrier collection. However, significant degradation in performance was found due to interfacial photocorrosion. To protect the surface and speed the oxygen-evolution reaction CoFeO x H y cocatalyst layers were deposited. By varying the number of consecutive sweeps and adjusting the applied bias range, an ultra-thin (~15 nm) CoFeO x H y cocatalyst layer was uniformly grown deposited over 30 cycles on the BiVO 4 surface. The resulting BiVO 4 /CoFeO x H y yielded 4.03 mA/cm 2 at 1.23 V RHE and onset potential of 0.24 V RHE , with stable operation (~15 % loss in photocurrent at 1.23 V RHE relative to ~60 % loss in the uncatalyzed control sample). These conformal CoFeO x H y catalytic layers function simultaneously to selectively collect photoexcited holes from the BiVO 4 , catalyze the water-oxidation reaction, and protect the BiVO 4 from photodegradation.

42 ENGINEERING↗

Comparative performance of bio-based coatings formulated with cellulose, chitin, and chitosan nanomaterials suitable for fruit preservation

Sustainable nanomaterials (SNMs) from wood, sugarcane and crab shell were prepared and used to coat selected fruits. The properties of SNMs and selected fruits were characterized and strawberry was used as an example to test antifungal activity and freshness preservation of the SNMs. The SNMs with their nano-structured morphology form strong shear-thinning dispersions for easy spraying on fruit surfaces. The fruit surface free energy was influenced by its surface morphology, predominant surface wax components, and cutin monomers. The antifungal activity of SNMs was influenced by their surface functional groups and particle size (crystals vs fibers). The coblend of wood nanocrystals (WCNCs) and chitosan nanofiber (CSNFs) exhibited the best antifungal property, which was comparable with the performance of the fungicide thiabendazole (80 mg L -1 ). The weight loss and color change of the WCNC/CSNF coated strawberries decreased by nearly half compared with the control samples, showing coating effectiveness on preserving fruit freshness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Moderate temperature sintering of BaZr 0.8 Y 0.2 O 3-δ protonic ceramics by A novel cold sintering pretreatment

The state-of-the-art protonic ceramic conductor BaZr 0.8 Y 0.2 O 3-δ (BZY20) requires an extremely high sintering temperature (≥1700 °C) to achieve the desired relative density and microstructure necessary to function as a proton conducting electrolyte. In this work, we developed a cold sintering pretreatment assisted moderate-temperature sintering method for the fabrication of high-quality pure BZY20 pellets. BZY20 pellets with high relative density of ~94% were fabricated with a final sintering temperature of 1500 °C (200 °C lower than the traditional sintering temperature). A comparison with BZY20 control samples indicated that the proper amount of BaCO 3 introduced on the BZY20 particle surface and the high green density achieved by cold sintering pretreatment were the main drivers for lowering the sintering temperature. The electrical conductivity measurement by electrochemical impedance spectroscopy showed that the as-prepared BZY20 pellets have a proton conductivity comparable to the state-of-the-art values. The cold sintering pretreatment outlined in this work has the potential to lower the sintering temperatures for similar types of protonic ceramic materials under consideration for a wide range of energy conversion and storage applications.

36 MATERIALS SCIENCE↗