Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

PROBING THE TRANSITION BETWEEN THE SYNCHROTRON AND INVERSE-COMPTON SPECTRAL COMPONENTS OF 1ES 1959+650

1ES 1959+650 is one of the most remarkable high-peaked BL Lacertae objects (HBL). In 2002, it exhibited a TeV {gamma}-ray flare without a similar brightening of the synchrotron component at lower energies. This orphan TeV flare remained a mystery. We present the results of a multifrequency campaign, triggered by the INTEGRAL IBIS detection of 1ES 1959+650. Our data range from the optical to hard X-ray energies, thus covering the synchrotron and inverse-Compton components simultaneously. We observed the source with INTEGRAL, the Swift X-Ray Telescope, and the UV-Optical Telescope, and nearly simultaneously with a ground-based optical telescope. The steep spectral component at X-ray energies is most likely due to synchrotron emission, while at soft {gamma}-ray energies the hard spectral index may be interpreted as the onset of the high-energy component of the blazar spectral energy distribution (SED). This is the first clear measurement of a concave X-ray-soft {gamma}-ray spectrum for an HBL. The SED can be well modeled with a leptonic synchrotron self-Compton model. When the SED is fitted this model requires a very hard electron spectral index of q {approx} 1.85, possibly indicating the relevance of second-order Fermi acceleration.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron self-Compton radiation from magnetically dominated turbulent plasmas in relativistic jets

ABSTRACT Relativistic jets launched by rotating black holes are powerful emitters of non-thermal radiation. Extraction of the rotational energy via electromagnetic stresses produces magnetically dominated jets, which may become turbulent. Studies of magnetically dominated plasma turbulence from first principles show that most of the accelerated particles have small pitch angles, i.e. the particle velocity is nearly aligned with the local magnetic field. We examine synchrotron self-Compton radiation from anisotropic particles in the fast cooling regime. The small pitch angles reduce the synchrotron cooling rate and promote the role of inverse Compton (IC) cooling, which can occur in two different regimes. In the Thomson regime, both synchrotron and IC components have soft spectra, νFν ∝ ν1/2. In the Klein–Nishina regime, synchrotron radiation has a hard spectrum, typically νFν ∝ ν, over a broad range of frequencies. Our results have implications for the modelling of BL Lacertae objects (BL Lacs) and gamma-ray bursts (GRBs). BL Lacs produce soft synchrotron and IC spectra, as expected when Klein–Nishina effects are minor. The observed synchrotron and IC luminosities are typically comparable, which indicates a moderate anisotropy with pitch angles θ ≳ 0.1. Rare orphan gamma-ray flares may be produced when θ ≪ 0.1. The hard spectra of GRBs may be consistent with synchrotron radiation when the emitting particles are IC cooling in the Klein–Nishina regime, as expected for pitch angles θ ∼ 0.1. Blazar and GRB spectra can be explained by turbulent jets with a similar electron plasma magnetization parameter, σe ∼ 104, which for electron–proton plasmas corresponds to an overall magnetization σ = (me/mp)σe ∼ 10.

79 ASTRONOMY AND ASTROPHYSICS↗

Comptonization by reconnection plasmoids in black hole coronae – III. Dependence on the guide field in pair plasma

ABSTRACT We perform non-radiative two-dimensional particle-in-cell simulations of magnetic reconnection for various strengths of the guide field (perpendicular to the reversing field), in magnetically dominated electron–positron plasmas. Magnetic reconnection under such conditions could operate in accretion disc coronae around black holes. There, it has been suggested that the transrelativistic bulk motions of reconnection plasmoids containing inverse-Compton-cooled electrons could Compton-upscatter soft photons to produce the observed non-thermal hard X-rays. Our simulations are performed for magnetizations 3 ≤ σ ≤ 40 (defined as the ratio of enthalpy density of the reversing field to plasma enthalpy density) and guide field strengths 0 ≤ Bg/B0 ≤ 1 (normalized to the reversing field strength B0). We find that the mean bulk energy of the reconnected plasma depends only weakly on the flow magnetization but strongly on the guide field strength – with Bg/B0 = 1 yielding a mean bulk energy twice smaller than Bg/B0 = 0. Similarly, the dispersion of bulk motions around the mean – a signature of stochasticity in the plasmoid chain’s motions – is weakly dependent on magnetization (for σ ≳ 10) but strongly dependent on the guide field strength – dropping by more than a factor of two from Bg/B0 = 0 to Bg/B0 = 1. In short, reconnection in strong guide fields (Bg/B0 ∼ 1) leads to slower and more ordered plasmoid bulk motions than its weak guide field (Bg/B0 ∼ 0) counterpart.

Astronomy & Astrophysics↗

Relativistic turbulence with strong synchrotron and synchrotron self-Compton cooling

Many relativistic plasma environments in high-energy astrophysics, including pulsar wind nebulae (PWN), hot accretion flows on to black holes, relativistic jets in active galactic nuclei and gamma-ray bursts, and giant radio lobes, are naturally turbulent. The plasma in these environments is often so hot that synchrotron and inverse-Compton (IC) radiative cooling becomes important. In this paper, we investigate the general thermodynamic and radiative properties (and hence the observational appearance) of an optically thin relativistically hot plasma stirred by driven magnetohydrodynamic (MHD) turbulence and cooled by radiation. We find that if the system reaches a statistical equilibrium where turbulent heating is balanced by radiative cooling, the effective electron temperature tends to attain a universal value θ=kT e /m e c 2 ~ 1/√τ T , where τT = n e σT L « 1 is the system's Thomson optical depth, essentially independent of the strength of turbulent driving and hence of the magnetic field. This is because both MHD turbulent dissipation and synchrotron cooling are proportional to the magnetic energy density. We also find that synchrotron self-Compton (SSC) cooling and perhaps a few higher order IC components are automatically comparable to synchrotron in this regime. The overall broad-band radiation spectrum then consists of several distinct components (synchrotron, SSC, etc.), well separated in photon energy (by a factor ~τ T -1 ) and roughly equal in power. The number of IC peaks is checked by Klein–Nishina effects and depends logarithmically on τT and the magnetic field. We also examine the limitations due to synchrotron self-absorption, explore applications to Crab PWN and blazar jets, and discuss links to radiative magnetic reconnection.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of deeply virtual Compton scattering at the future electron-ion collider

This study presents the impact of future measurements of deeply virtual Compton scattering (DVCS) with the ePIC detector at the electron-ion collider (EIC), currently under construction at Brookhaven National Laboratory. The considered process is sensitive to generalized parton distributions (GPDs), the understanding of which is a cornerstone of the EIC physics program. Our study marks a milestone in the preparation of DVCS measurements at EIC and provides a reference point for future analyses. In addition to presenting distributions of basic kinematic variables obtained with the latest ePIC design and simulation software, we examine the impact of future measurements on the understanding of nucleon tomography and DVCS Compton form factors, which are directly linked to GPDs. We also assess the impact of radiative corrections and background contribution arising from exclusive π 0 production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-dependent QED approach to x-ray nonlinear Compton scattering

Motivated by a recent experiment, we theoretically investigate the process of x-ray nonlinear Compton scattering (XNLC). Our approach is based on the time-dependent Schrödinger equation for an atomic system subject to an intense x-ray pulse, and explicitly accounts for the spontaneous scattering into a quantized photonic mode. We employ our framework to study multiple nonlinear scattering scenarios. Initially, we consider soft x rays at 500eV photon energy to scatter nonlinearly off a helium target. For this, we find that XNLC is dominated by certain third-order processes rather than the naïvely expected mechanisms pertaining to the lowest order of perturbation theory. Subsequently, we apply our model to XNLC in helium at 4.0keV photon energy and beryllium at 9.7keV. Contrary to the conclusions drawn from the experimental observations, our results suggest a good agreement of the XNLC spectrum with simple, free-electron model predictions. Furthermore, our studies reveal striking qualitative similarities of linear and nonlinear Compton scattering cross sections in this regime.

74 ATOMIC AND MOLECULAR PHYSICS↗

Free-electron laser inverse-Compton interaction x-ray source

Free-electron lasers (FEL) and synchrotron sources of high brilliance x-rays have been confirmed to be of tremendous value in basic and applied research. Inverse-Compton sources (ICS) can achieve brilliance matching the requirements of many applications pioneered at those FEL and synchrotron facilities—including phase contrast imaging, macromolecular x-ray crystallography, and x-ray microscopy—but with size, cost, and complexity compatible with a small laboratory. The free-electron laser inverse-Compton interaction compact x-ray source at the University of Hawaii at Manoa is a unique approach to an ICS which employs an FEL as the laser source. We have measured a total average flux of 3.0 × 10 5 photons / second with an average brilliance of 2.0 × 10 7 photons / s mm 2 mrad 2 0.1% of bandwidth (BW) with a peak energy of 10.9 keV from the source. While these results are modest in comparison to the standards set by other IC sources, upgrades to the system have the potential to increase the total average flux to 9.2 × 10 11 photons / second with an average brilliance of 1.9 × 10 12 photons / s mm 2 mrad 2 0.1% BW: comparing more favorably to other sources. We discuss the scientific program, the progress made in design and development, and the achievements of the source to date. We also outline future upgrades and integration needed to yield an enabling source for emerging high brilliance x-ray applications.

43 PARTICLE ACCELERATORS↗

Compton scattering from He 4 at the TUNL HI γ S facility

Differential cross sections for elastic Compton scattering from 4 He have been measured with high statistical precision at the High Intensity γ-ray Source at laboratory scattering angles of 55°, 90°, and 125° using a quasi-monoenergetic photon beam with a weighted mean energy value of 81.3 MeV. The results are compared to previous measurements and similar fore-aft asymmetry in the angular distribution of the differential cross sections is observed. Lastly, this experimental work is expected to strongly motivate the development of effective-field-theory calculations of Compton scattering from 4 He to fully interpret the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of deeply virtual Compton scattering off 4 He with the CEBAF Large Acceptance Spectrometer at Jefferson Lab

We report on the measurement of the beam spin asymmetry in the deeply virtual Compton scattering off $^4$He using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab using a 6 GeV longitudinally polarized electron beam incident on a pressurized $^4$He gaseous target. We detail the method used to ensure the exclusivity of the measured reactions, in particular the upgrade of CLAS with a radial time projection chamber to detect the low-energy recoiling $^4$He nuclei and an inner calorimeter to extend the photon detection acceptance at forward angles. Our results confirm the theoretically predicted enhancement of the coherent ($e^4$He$~\to~e'$$^4$He$'\gamma'$) beam spin asymmetries compared to those observed on the free proton, while the incoherent ($e^4$He$~\to~e'$p$'\gamma'$X$'$) asymmetries exhibit a 30$\%$ suppression. From the coherent data, we were able to extract, in a model-independent way, the real and imaginary parts of the only $^4$He Compton form factor, $\cal H_A$, leading the way toward 3D imaging of the partonic structure of nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploring the Structure of the Bound Proton with Deeply Virtual Compton Scattering

In the past two decades, deeply virtual Compton scattering of electrons has been successfully used to advance our knowledge of the partonic structure of the free proton and investigate correlations between the transverse position and the longitudinal momentum of quarks inside the nucleon. Meanwhile, the structure of bound nucleons in nuclei has been studied in inclusive deep-inelastic lepton scattering experiments off nuclear targets, showing a significant difference in longitudinal momentum distribution of quarks inside the bound nucleon, known as the EMC effect. In this work, we report the first beam spin asymmetry (BSA) measurement of exclusive deeply virtual Compton scattering (DVCS) off a proton bound in $^4$He. The data used here were accumulated using a $6$ GeV longitudinally polarized electron beam incident on a pressurized $^4$He gaseous target placed within the CLAS spectrometer in Hall-B at the Thomas Jefferson National Accelerator Facility. Here, the azimuthal angle ($\phi$) dependence of the BSA was studied in a wide range of virtual photon and scattered proton kinematics. The $Q^2$, $x_B$, and t dependencies of the BSA on the bound proton are compared with those on the free proton. In the whole kinematical region of our measurements, the BSA on the bound proton is smaller by 20\% to 40\%, indicating possible medium modification of its partonic structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiative Particle-in-Cell Simulations of Turbulent Comptonization in Magnetized Black-Hole Coronae

We report results from the first radiative particle-in-cell simulations of strong Alfvénic turbulence in plasmas of moderate optical depth. The simulations are performed in a local 3D periodic box and self-consistently follow the evolution of radiation as it interacts with a turbulent electron-positron plasma via Compton scattering. We focus on the conditions expected in magnetized coronae of accreting black holes and obtain an emission spectrum consistent with the observed hard state of Cyg X-1. Most of the turbulence power is transferred directly to the photons via bulk Comptonization, shaping the peak of the emission around 100 keV. The rest is released into nonthermal particles, which generate the MeV spectral tail. As a result, the method presented here shows promising potential for ab initio modeling of various astrophysical sources and opens a window into a new regime of kinetic plasma turbulence.

79 ASTRONOMY AND ASTROPHYSICS↗

First Measurement of Deeply Virtual Compton Scattering on the Neutron with Detection of the Active Neutron

Measuring deeply virtual Compton scattering (DVCS) on the neutron is one of the necessary steps to understand the structure of the nucleon in terms of generalized parton distributions (GPDs). Neutron targets play a complementary role to transversely polarized proton targets in the determination of the GPD E . This poorly known and poorly constrained GPD is essential to obtain the contribution of the quarks’ angular momentum to the spin of the nucleon. DVCS on the neutron was measured for the first time selecting the exclusive final state by detecting the neutron, using the Jefferson Lab longitudinally polarized electron beam, with energies up to 10.6 GeV, and the CLAS12 detector. The extracted beam-spin asymmetries, combined with DVCS observables measured on the proton, allow a clean quark-flavor separation of the imaginary parts of the Compton form factors H and E . Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Filtered Backprojection in Compton Imaging using a Spherical Harmonic Wiener Filter with Pixelated CdZnTe

Filtered backprojection is an image reconstruction technique for Compton imaging that provides reasonably high resolution at much lower computational costs when compared to iterative methods. Here, this work applies a Wiener filter that has been derived for spherical harmonics on Compton imaging using the OrionUM pixelated CdZnTe imaging-spectrometer. To regularize the filter, an investigation is made into the power spectral density of the signal and noise to develop an appropriate spectral signal-to-noise ratio model for the restoration process. Experimental measurements were conducted with two 228Th sources placed 30° apart. The resulting filtered image of the two sources have an average full-width-at-half-maximum (FWHM) of 9.8° or 7.5° when using a mean squared error and structural similarity optimization approach respectively; an improvement from the 29.0° FWHM image when using simple backprojection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New results from sub-3 MeV Compton spectrometer experiments

We report that our team at Los Alamos National Laboratory has successfully employed Compton spectrometers to measure the X-ray spectra of both continuous and flash radiographic sources. In this method, a collimated beam of X-rays incident on a converter foil ejects Compton electrons. A collimator may be inserted into the entrance of the spectrometer to narrow the angular acceptance of the forward-scattered electrons, which then enter the magnetic field region of the spectrometer. The position of the electrons at the magnet’s focal plane is proportional to the square root of their momentum, allowing the X-ray spectrum to be reconstructed. A new samarium-cobalt spectrometer with an energy range of 50 keV to 4 MeV has been fielded at two facilities. Finally, the X-ray generating machines produced intense photon beams (> 4 rad at 1 m) with spectral endpoints below 3 MeV. Recent experimental results will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-A-9A-03: Development and Verification of a Forward Model That Assists in Iterative Post-Processing Algorithms Used to Reduce Blur in Compton Backscatter Imaging Systems

Purpose: In Compton Backscatter Imaging (CBI), the source and detector reside on the same side of the patient. We previously demonstrated the applicability of CBI systems for medical purposes using an industrial system. To assist in post-processing images from a CBI system, a forward model based on radiation absorption and scatter principles has been developed. Methods: The forward model was developed in C++ using raytracing to track particles. The algorithm accepts phantoms of any size and resolution to calculate the fraction of incident photons scattered back to the detector, and can perform these calculations for any detector geometry and source specification. To validate the model, results were compared to MCNP-X, which is a Monte Carlo based simulation software, for various combinations of source specifications, detector geometries, and phantom compositions. Results: The model verified that the backscatter signal to the detector was based on three interaction probabilities: a) attenuation of photons going into the phantom, b) Compton scatter of photons toward the detector, and c) attenuation of photons coming out of the phantom. The results from the MCNP-X simulations and the forward model varied from 1 to 5%. This difference was less than 1% for energies higher than 30 keV, but was up to 4% for lower energies. At 50 keV, the difference was less than 1% for multiple detector widths and for both homogeneous and heterogeneous phantoms. Conclusion: As part of the optimization of a medical CBI system, an efficient and accurate forward model was constructed in C++ to estimate the output of CBI system. The model characterized individual components contributing to CBI output and increased computational efficiency over Monte Carlo simulations. It is now used in the development of novel post-processing algorithms that reduce image blur by reversing undesired contribution from outside the region of interest.

07 ISOTOPE AND RADIATION SOURCES↗

Poster — Thur Eve — 01: The effect of the number of projections on MTF and CNR in Compton scatter tomography

Purpose: To investigate the dependence of the reconstructed image quality on the number of projections in multi-projection Compton scatter tomography (MPCST). The conventional relationship between the projection number used for reconstruction and reconstructed image quality pertained to CT does not necessarily apply to MPCST, which can produce images from a single projection if the detectors have sufficiently high energy and spatial resolution. Methods: The electron density image was obtained using filtered-backprojection of the scatter signal over circular arcs formed using Compton equation. The behavior of the reconstructed image quality as a function of the projection number was evaluated through analytical simulations and characterized by CNR and MTF. Results: The increase of the projection number improves the contrast with this dependence being a function of fluence. The number of projections required to approach the asymptotic maximum contrast decreases as the fluence increases. Increasing projection number increases the CNR but not spatial resolution. Conclusions: For MPCST using a 500eV energy resolution and a 2×2mm{sup 2} size detector, an adequate image quality can be obtained with a small number of projections provided the incident fluence is high enough. This is conceptually different from conventional CT where a minimum number of projections is required to obtain an adequate image quality. While increasing projection number, even for the lowest dose value, the CNR increases even though the number of photons per projection decreases. The spatial resolution of the image is improved by increasing the sampling within a projection rather than by increasing the number of projections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗