Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Buildings Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

HP-FLEX: Field Demonstration of the Semantics-Driven Configuration of a Model Predictive Control System to Make Heat Pumps Flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Real time side-by-side experimental validation of energy and comfort performance of a zero net energy retrofit package for small commercial buildings

Making buildings zero-net energy (ZNE) is one of the major strategies for achieving carbon emission reduction goals. For this strategy to be successful, it entails a very significant reduction in energy use – 50% or more. In small commercial buildings, however, owners and building management teams usually have limited resources for identifying, analyzing, and procuring appropriate retrofit measures for reducing such use. An approach to overcome this limitation is the development of bundles of energy efficiency measures that can be presented to building owners/operators as a comprehensive package. The research presented in this paper focuses on an experimental evaluation of the impacts of a retrofit package developed for small office buildings in California. Performing this evaluation in a full-scale whole-building integrated systems test facility allowed a side-by-side evaluation in real time, against a reference case, of the impact of the retrofit package not only on energy use but also on visual and thermal comfort. Here, the retrofit package evaluated is comprised of a combination of HVAC, lighting (including daylighting), and plug load measures. The evaluation occurred at different times of the year in order to account for seasonal variations in environmental conditions, including solar angles and weather. The experimental facility allowed testing for two different façade orientations: south and west. Results show that the proposed ZNE retrofit package can save significant amounts of energy for small commercial buildings. During cooling-prevalent periods, total energy savings were 65% for south orientation and 68% for west orientation; during heating-prevalent periods total energy savings were 22% for south orientation and 25% for west orientation. Measurements indicate that the ZNE retrofit package resulted in small but not very significant changes in comfort levels for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Resolution, Lightweight, and Low-cost X-Ray Optics for the Lynx Observatory

We describe an approach to build an x-ray mirror assembly that can meet Lynx’s requirements of high-angular resolution, large effective area, light weight, short production schedule, and low-production cost. Adopting a modular hierarchy, the assembly is composed of 37,492 mirror segments, each of which measures ∼100 mm × 100 mm × 0.5 mm. These segments are integrated into 611 modules, which are individually tested and qualified to meet both science performance and spaceflight environment requirements before they in turn are integrated into 12 metashells. The 12 metashells are then integrated to form the mirror assembly. This approach combines the latest precision polishing technology and the monocrystalline silicon material to fabricate the thin and lightweight mirror segments. Because of the use of commercially available equipment and material and because of its highly modular and hierarchical building-up process, this approach is highly amenable to automation and mass production to maximize production throughput and to minimize production schedule and cost. As of fall 2018, the basic elements of this approach, including substrate fabrication, coating, alignment, and bonding, have been validated by the successful building and testing of single-pair mirror modules. In the next few years, the many steps of the approach will be refined and perfected by repeatedly building and testing mirror modules containing progressively more mirror segments to fully meet science performance, spaceflight environments, as well as programmatic requirements of the Lynx mission and other proposed missions, such as AXIS.

Zhang, William W.↗

New energy technologies for buildings

The principal objective of the present work is to identify a variety of strategic approaches which could significantly enhance the rate of commercial development and deployment of total energy systems, fuel cells, and solar conversion. Emphasis is on the need for integration of research, conference, legislation, federal program, and industrial program aspects, leading to a fruitful feedback and follow-through process involving new energy technologies. The discussions are on a general, lay level. Recommendations made feature (1) action which improves the environment for innovation and change, (2) action which decreases risk and creates positive incentives, and (3) action which reflects the distance a particular technology is from commercialization and widespread use, as determined by its position on a development/diffusion scale.

Schoen, R.↗

Commercial Integrated Heat Pump with Thermal Storage --Demonstrate Greater than 50% Average Annual Energy Savings, Compared with Baseline Heat Pump and Water Heater (Go/No-Go) FY16 4th Quarter Milestone Report

For this study, we authored a new air source integrated heat pump (AS-IHP) model in EnergyPlus, and conducted building energy simulations to demonstrate greater than 50% average energy savings, in comparison to a baseline heat pump with electric water heater, over 10 US cities, based on the EnergyPlus quick-service restaurant template building. We also assessed water heating energy saving potentials using ASIHP versus gas heating, and pointed out climate zones where AS-IHPs are promising.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient buildings for fire-adapted landscapes: EE and flexible loads integrated with solar and storage microgrids

Energy efficiency (EE) and flexible loads can be part of a resilient buildings packagewhen they are combined with solar and storage in a clean energy microgrid to reduce the carbonfootprint of buildings and enable resilience to extreme events. Recent large wildfires and an emerging understanding of the fire-adapted landscapes in the American West underscore the urgency of work towards scaling and commercializing these systems. For example, a recent power shutoff in Northern California (October 9-12, 2019) resulted in 738k customers disconnected at the peak of the outage and is emblematic of challenges to come. Our paper reports on insights from a clean energy microgrid deployment pilot that integrates a 50 kWAC PV array, a 109 kW / 174 kWh battery system, switchgear to safely isolate from the regional power system, and communicating controllers for HVAC and refrigeration. The project will be commissioned in May 2020 and is sited at a critical infrastructure site in rural Northern California – in this case a gasoline station with convenience store. Our experience and results shed light on capabilities of integrated microgrids to provide value to customers during blue sky conditions and resilience during black sky days with high fire risk, and what opportunities and barriers exist for scaling these integrated microgrid systems in the near term. We use a simulation model to estimate how EE and flexibility can extend the run time of solar and storage, improving the reliability of power at critical sites.

Alstone, Peter↗

Knoxville's Community Development Corporation

Develop and field validate integrated retrofit solutions (overclad composite panels, easy-to-install panel connections, and a cost-effective approach to gather measurements of existing facades) that are applicable to residential and mid-size commercial buildings, although components of the retrofit package can be implemented in other buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wireless Sensor for Measuring Pump Efficiency: Small Business Voucher Project with KCF Technologies

This document is to fulfill the final report requirements for the Small Business Voucher (SBV) CRADA project with ORNL and KCF Technologies (CRADA/NFE-16-06133). Pumping systems account for nearly 20% of the world’s electrical energy demand and range from 25-50% of the energy usage in many industrial and building power plants. The energy cost is the largest element in the total cost of owning a pump (~40%). In response to a recent DOE mandate for improved pump efficiency pump manufacturers are preparing for the changes that the impending regulations will bring, including design improvements. This mandate also establishes a need for new low cost pump efficiency measurement systems. The standard industry definition of pump efficiency is the mechanical water horsepower delivered divided by the electrical horsepower input to the motor. KCF Technologies has developed a new sensor measurement technique to estimate fluid pump efficiency using a thermodynamic approach. KCF Technologies applied for a SBV grant with ORNL as the research partner. KCF needed a research partner with the proper facilities to demonstrate the efficacy of its wireless sensor unit for measuring pump efficiency. The ORNL Building Technologies Research and Integration Center (BTRIC) test resources were used to test and demonstrate the successful measurement of pump efficiency with the KCF sensor technology. KCF is now working on next steps to commercialize this sensing technology.

42 ENGINEERING↗

Challenges and Lessons Learned from an Analysis of Three Zero Energy Buildings

Zero energy buildings, or zero energy ready buildings, which are designed and operated by public or private commercial property owners can play an important role in reducing carbon emissions. This paper discusses lessons learned and key takeaways from an in-depth analysis of three zero energy buildings that took an integrated design and construction approach to significantly reduce energy use. Two of these projects are new construction and one is a retrofit to zero energy. Findings are based on project literature review, data analysis, and in-depth interviews with the building design teams and staff who were involved during the design, construction, and operation of the buildings. The paper addresses value proposition and cost data in such a way that other building owners can replicate the strategies and technology solutions in response to regulatory mandates or organizational goals. It also provides details on operational improvements taken at each zero energy building to enhance energy performance and increase the potential for load flexibility, and discusses challenges and lessons gleaned from design teams and building staff. The findings serve as a reference for building owners, designers, engineers, contractors, or others interested in, or involved with, the design, construction, or use of new or existing buildings. The paper also includes recommended pathways for widespread adoption of zero energy strategies that can be applied in various locations.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

MICROREACTOR APPLICATIONS, RESEARCH, VALIDATION, AND EVALUATION (MARVEL) REACTOR ? STATUS, CONSTRUCTION, AND TESTING

The paper presents the current status of the Microreactor Applications, Research, Validation, and Evaluation (MARVEL) microreactor design, qualification testing, fabrication, and high-level construction schedule. An overview of initial criticality, low power physics testing, and start-up testing is included, as well as an overview of the envisioned processes in which end-users can engage the project for access to operational data or specific demonstrations. Designed by the Idaho National Laboratory (INL) under the auspices of the US Department of Energy’s Microreactor Program for construction and operation at the INL, MARVEL is a small, fully functional advanced reactor with UZrH fuel and thermal output of 85 kW. It offers a unique opportunity for scaled demonstrations that can dramatically accelerate the design, licensing, and deployment of commercial microreactors for power production or process heat applications. MARVEL’s objective is to build a small liquid-metal thermal reactor at the INL to demonstrate design and operating processes for microreactors, microgrid integration, and process heat applications. MARVEL finished 90%-final-design in September 2023 and completed an independent project assessment in early 2024. Fabrication of long-lead components and fuel, safety analysis review, and procurement for construction are underway. MARVEL assembly and construction will start in 2025 and fuel loading is expected in mid- 2027. Initial criticality will be performed in a dry condition in late 2027, followed by loading of NaK coolant and start-up testing. Approximately six months later, release for unrestricted operations will enable subsequent testing of microreactor characteristics, microgrid integration and select heat extraction applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Paths Forward: Approaches to Achieve Plug and Process Load Efficiency and Control in Commercial Buildings: Preprint

To accomplish net-zero carbon in the built environment by 2050, we must equitably decarbonize commercial buildings, which includes reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not directly associated with major building end uses like lighting and heating, ventilating, and air conditioning. PPLs account for a growing portion of U.S. commercial building energy consumption. Although commercial building PPL strategies and technologies are available today, they have not been adopted at a level sufficient to achieve significant savings and load flexibility across the building stock. In our "Pathways to Plug and Process Load Efficiency and Control" study, we investigated why these technologies and strategies have not seen widespread adoption and identified five behavior and technology pathways to increase PPL reduction in commercial buildings. In this paper, we expand beyond identifying the pathways and discuss approaches for achieving them. We discuss the importance of collecting and sharing data and case studies on PPL energy consumption and savings from control technology implementation, including code-required measures, for increasing adoption. Centralizing case studies and data, engaging industry organizations, and promoting awareness of PPL efficiency benefits to relevant groups are also key approaches. Additionally, funding, incentives, and rebate programs play important roles in driving PPL efficiency and control adoption. Finally, we discuss integrating PPL efficiency into broader company goals, such as environmental, social and governance (ESG) strategies and green building certifications, to further drive adoption.

adoption pathways↗

A Three-in-One Hybrid Strategy for High-Performance Semiconducting Polymers Processed from Anisole

The development of semiconducting polymers with good processability in green solvents and competitive electrical performance is essential for realizing sustainable large-scale manufacturing and commercialization of organic electronics. A major obstacle is the processability-performance dichotomy that is dictated by the lack of ideal building blocks with balanced polarity, solubility, electronic structures, and molecular conformation. Herein, through the integration of donor, quinoid and acceptor units, an unprecedented building block, namely TQBT, is introduced for constructing a serial of conjugated polymers. The TQBT, distinct in non-symmetric structure and high dipole moment, imparts enhanced solubility in anisole—a green solvent—to the polymer TQBT-T. Furthermore, PTQBT-T possess a highly rigid and planar backbone owing to the nearly coplanar geometry and quinoidal nature of TQBT, resulting in strong aggregation in solution and localized aggregates in film. Remarkably, PTQBT-T films spuncast from anisole exhibit a hole mobility of 2.30 cm 2 V -1 s -1 , which is record high for green solvent-processable semiconducting polymers via spin-coating, together with commendable operational and storage stability. The hybrid building block emerges as a pioneering electroactive unit, shedding light on future design strategies in high-performance semiconducting polymers compatible with green processing and marking a significant stride towards ecofriendly organic electronics.

36 MATERIALS SCIENCE↗

Quantum Testbeds Stakeholder Workshop (QTSW) Report meeting purpose and agenda.

Quantum computing (QC) is a promising early-stage technology with the potential to provide scientific computing capabilities far beyond what is possible with even an Exascale computer in specific problems of relevance to the Office of Science. These include (but are not limited to) materials modeling, molecular dynamics, and quantum chromodynamics. However, commercial QC systems are not yet available and the technical maturity of current QC hardware, software, algorithms, and systems integration is woefully incomplete. Thus, there is a significant opportunity for DOE to define the technology building blocks, and solve the system integration issues to enable a revolutionary tool. Once realized, QC will have world changing impact on economic competitiveness, the scientific enterprise, and citizen well-being. Prior to this workshop, DOE / Office of Advanced Scientific Computing Research (ASCR) hosted a workshop in 2015 to explore QC scientific applications. The goal of that workshop was to assess the viability of QC technologies to meet the computational requirements in support of DOE’s science and energy mission and to identify the potential impact of these technologies.

97 MATHEMATICS AND COMPUTING↗

VIPER Rover: Flight Build and Environmental Test Status

The NASA Artemis Program plans to return humans to the Moon to stay. Extended human stays on the Moon will require substantial resources to sustain human presence, requiring continuous supplies delivered from the Earth. However, if some of the resources were indigenously available, Earth logistical requirements could be substantially reduced by “living off the land” with in-situ lunar resources. Local volatiles could be processed into propellants and human life-supporting needs, reducing risk of maintaining a permanent human presence on the Moon. LCROSS, LRO and other missions have confirmed the presence of lunar volatiles resources in polar regions, so the next step is to understand the physical distribution of those resources, as well as the scientific basis for how water got there, and why it is still there. The Volatiles Investigating Polar Exploration Resource (VIPER) is a surface mobility scientific platform, designed to spend ~100 days mapping and surveying four different Ice Stability Regions to understand the scientific nature and distribution of water and other volatiles. VIPER will also provide scientific mineralogical context of the lunar regolith, such as the presence of silicon and light metals in lunar regolith, providing a composite picture of resource availability and sustainment. This paper will discuss VIPER’s completion of the flight rover build, as well as current progress in environmental testing, preparedness for mission operations, and overall readying for launch integration with our CLPS partner. VIPER is managed within NASA’s Science Mission Directorate (SMD), utilizing the Commercial Lunar Payload Services (CLPS) lunar delivery model.

VIPER↗

Viper Rover: Flight Build and Environmental Test Status

The NASA Artemis Program plans to return humans to the Moon to stay. Extended human stays on the Moon will require substantial resources to sustain human presence, requiring continuous supplies delivered from the Earth. However, if some of the resources were indigenously available, Earth logistical requirements could be substantially reduced by “living off the land” with in-situ lunar resources. Local volatiles could be processed into propellants and human life-supporting needs, reducing risk of maintaining a permanent human presence on the Moon. LCROSS, LRO and other missions have confirmed the presence of lunar volatiles resources in polar regions, so the next step is to understand the physical distribution of those resources, as well as the scientific basis for how water got there, and why it is still there. The Volatiles Investigating Polar Exploration Resource (VIPER) is a surface mobility scientific platform, designed to spend ~100 days mapping and surveying four different Ice Stability Regions to understand the scientific nature and distribution of water and other volatiles. VIPER will also provide scientific mineralogical context of the lunar regolith, such as the presence of silicon and light metals in lunar regolith, providing a composite picture of resource availability and sustainment. This paper will discuss VIPER’s completion of the flight rover build, as well as current progress in environmental testing, preparedness for mission operations, and overall readying for launch integration with our CLPS partner. VIPER is managed within NASA’s Science Mission Directorate (SMD), utilizing the Commercial Lunar Payload Services (CLPS) lunar delivery model.

rover↗

VIPER Rover Flight Build and Environmental Test Status

The NASA Artemis Program plans to return humans to the Moon to stay. Extended human stays on the Moon will require substantial resources to sustain human presence, requiring continuous supplies delivered from the Earth. However, if some of the resources were indigenously available, Earth logistical requirements could be substantially reduced by “living off the land” with in-situ lunar resources. Local volatiles could be processed into propellants and human life-supporting needs, reducing risk of maintaining a permanent human presence on the Moon. LCROSS, LRO and other missions have confirmed the presence of lunar volatiles resources in polar regions, so the next step is to understand the physical distribution of those resources, as well as the scientific basis for how water got there, and why it is still there. The Volatiles Investigating Polar Exploration Resource (VIPER) is a surface mobility scientific platform, designed to spend ~100 days mapping and surveying four different Ice Stability Regions to understand the scientific nature and distribution of water and other volatiles. VIPER will also provide scientific mineralogical context of the lunar regolith, such as the presence of silicon and light metals in lunar regolith, providing a composite picture of resource availability and sustainment. This paper will discuss VIPER’s completion of the flight rover build, as well as current progress in environmental testing, preparedness for mission operations, and overall readying for launch integration with our CLPS partner. VIPER is managed within NASA’s Science Mission Directorate (SMD), utilizing the Commercial Lunar Payload Services (CLPS) lunar delivery model.

rover↗

Xcel Energy – LBNL ‘Beyond Widgets’ Project. Workstation Specific Lighting with Daylight Dimming Controls System Program Manual

This program manual was developed through a U.S. Department of Energy project to develop streamlined utility program approaches to the deployment of integrated systems in commercial offices. Integrated systems present deep opportunities for energy savings, however by nature these systems have additional levels of complexity and effort required for their design and energy savings assessment, which create barriers for utility incentive programs to develop streamlined cost effective incentive programs to capture these savings. This project worked with Xcel Energy in Colorado and Minnesota to select an integrated system and develop a streamlined approach to its deployment for small and large commercial offices. Xcel Energy worked with LBNL to select a workstation specific lighting system with daylight dimming controls, applied as a retrofit in commercial office spaces. Previous studies indicated a potential lighting annual energy savings of 28-63%, with an average of 47% for this system type, due to reduced fixture LPD and controls only, not including a full fixture replacement from a condition such as T8 to LED. Xcel also had a desire to incorporate this fixture replacement in their integrated system package, and as a result annual energy lighting savings are expected to be higher. FLEXLAB testing of the system for 500 lux minimum output conditions translated into a 94% annual energy savings for this system. Market analysis was developed for large and medium commercial office buildings in Xcel’s Minnesota and Colorado markets showing a potential for 48-295 and 120-672 GWh of energy savings potential for Colorado and Minnesota respectively. Total Resource Costs (TRC) vary by location and technology package used (enterprise versus non-enterprise lighting controls system), and vary from 0.29 to 1.27 and 0.06 and 0.44 for a Retrofit case, and 0.20 to 1.63 and 0.07 to 0.57 for a Replace on Burnout strategy for Colorado and Minnesota respectively. These results indicate good potential for demonstrating a strong technical and economic case for deployment of this system type in Xcel’s Colorado territory, while deployment in the Minnesota market may be advisable as well as part of a portfolio of programs, or as an effort to help shift the market into integrated systems deployment in general. It should be noted that the cost of avoided energy in both markets is significantly low ($0.07/kWh for Minnesota, $0.08/kWh for Colorado), and these TRC values would not be representative of deployment potential in other markets with higher utility rates. In addition, installation costs used for these systems may decrease with time, further enhancing their return on investment. Overall, workstation specific lighting systems with daylight dimming controls present a very strong potential for cost effective lighting energy savings, as demonstrated by the FLEXLAB test results and previous case studies. Further energy savings may be realized from the use of fixture-specific occupancy sensors as well, although this approach was not considered in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗