End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impacts of Model Building Energy Codes – Interim Update

The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates state and national impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, assessed the prospective impacts of national model building energy codes from 2010 through 2040. The model codes of interest in this report are the International Energy Conservation Code (IECC) for residential buildings and ASHRAE Standard 90.1 for commercial buildings. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions at the state and national levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Model Building Energy Codes

The Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates state and national impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, assessed the prospective impacts of national model building energy codes from 2010 through 2040. The model codes of interest in this report are the International Energy Conservation Code (IECC) for residential buildings and ASHRAE Standard 90.1 for commercial buildings. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions at the state and national levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimation of the Relationship Between Remotely Sensed Anthropogenic Heat Discharge and Building Energy Use

This paper examined the relationship between remotely sensed anthropogenic heat discharge and energy use from residential and commercial buildings across multiple scales in the city of Indianapolis, Indiana, USA. The anthropogenic heat discharge was estimated with a remote sensing-based surface energy balance model, which was parameterized using land cover, land surface temperature, albedo, and meteorological data. The building energy use was estimated using a GIS-based building energy simulation model in conjunction with Department of Energy/Energy Information Administration survey data, the Assessor's parcel data, GIS floor areas data, and remote sensing-derived building height data. The spatial patterns of anthropogenic heat discharge and energy use from residential and commercial buildings were analyzed and compared. Quantitative relationships were evaluated across multiple scales from pixel aggregation to census block. The results indicate that anthropogenic heat discharge is consistent with building energy use in terms of the spatial pattern, and that building energy use accounts for a significant fraction of anthropogenic heat discharge. The research also implies that the relationship between anthropogenic heat discharge and building energy use is scale-dependent. The simultaneous estimation of anthropogenic heat discharge and building energy use via two independent methods improves the understanding of the surface energy balance in an urban landscape. The anthropogenic heat discharge derived from remote sensing and meteorological data may be able to serve as a spatial distribution proxy for spatially-resolved building energy use, and even for fossil-fuel CO2 emissions if additional factors are considered.

Multi-scale↗

A Guide for Creating a Building-Level Action Plan to Improve Energy Efficiency and Reduce Carbon Emissions

Action plans are tools for commercial building owners to create pathways for reducing energy use and decarbonize, hence reducing carbon emissions. This template and associated direction manual provides a method for creating an action plan. Originally created for the Better Buildings Low Carbon Pilot, it can also be applied to the Better Buildings Climate Challenge and for any building owner striving towards lower carbon footprints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IS BLOCKCHAIN A SUITABLE TECHNOLOGY FOR ENSURING THE INTEGRITY OF DATA SHARED BY LIGHTING AND OTHER BUILDING SYSTEMS?

Increasing amounts of data are available from lighting and other building systems. In commercial buildings, these data can be used to improve system and energy performance, detect and diagnose faults, and facilitate maintenance. Building data are not only of interest to owners and operators of the building systems, however. Owners and operators of similar buildings, manufacturers of building systems, utilities, and city agencies also have interesting use cases. Energy data can, for example, be used to verify the performance of energy-conservation measures, issue renewableenergy certificates, and financially settle grid services. Increased data sharing, however, significantly expands the cyber-attack surface, creating new challenges. In this work, blockchain is explored as an option for ensuring the integrity of data that are shared by lighting and other building systems. Blockchain fundamentals and variants are briefly reviewed, and value propositions relevant to building systems are discussed. A recently developed blockchain applicability framework (BAF) that builds upon and addresses the limitations of previous applicability models is also briefly reviewed. The BAF is used to assess the suitability of blockchain over other technologies or approaches for building-data applications, using emerging connected lighting systems as an example use case.

blockchain, connected lighting system, data integr↗

An open control sequence specification to scale building demand flexibility via analytics software

For over two decades, researchers and practitioners have showcased the ability of large commercial buildings to provide grid services by shedding or shifting load. Various utility demand response (DR) and virtual power plant (VPP) programs throughout the United States are presently utilizing these demand-side resources. However, growth of these programs have been limited, in part due to the high cost necessary to integrate the DR control strategies into the building automation system (BAS). Implementing these strategies involves adjusting control sequences, necessitating dozens of hours of customized programming per building, limiting their adoption to large organizations and progressive owners. Recent efforts by researchers and industry have demonstrated the capability of energy management and information systems (EMIS), originally designed for fault detection and diagnostics, to interface with existing BAS and perform supervisory control to optimize building operations. While these approaches are quickly being adopted by industry, demand flexibility (DF) control strategies remain limited in product offerings. One of the challenges is the lack of documented best-practice DF sequences, despite the rich literature on field implementations. This paper develops a new open-specification for a zone-based temperature adjustment shed strategy for commercial building HVAC systems, describing the specification’s implementation in two EMIS tools in both experimental and field settings. Both implementations successfully reduced electric load by at least 40% on average during the called event, while maintaining temperature limits. This study’s detailed process from specification to deployment shows the potential for scalability as well as highlights challenges related to integration with heterogeneous BAS products.

Granderson, Jessica↗

Western States Building Energy & Controls Apprenticeship (BECA) Program

How does this project help to understand the challenges of workforce development in the commercial building energy management industry? The purpose of this project was to create a replicable, scalable, and portable apprenticeship program for building energy management and controls. This paper will demonstrate how local processes can be more adaptable and inclusive than federal processes in achieving workforce development goals. Our work provides insights into the technical effectiveness of the program, enabling others to achieve greater success in their workforce development initiatives. The project required more time and financial resources than initially anticipated and spent a year in a no-cost extension working to accomplish the Statement of Project Objectives. The original goal was to create an Industry Related Apprenticeship Program (IRAP). The development of this apprenticeship presented challenges due to the lack of existing programs for reference and the absence of relevant industry classification codes by the Department of Labor (DOL). Notably, the role of a commercial building energy analyst is not recognized by the DOL. The SIC (industry codes) do not have a good description of this job. There are many that may fall into related categories, but none are the actual duties of an energy analyst. Discussions with the DOL indicated that substantial groundwork was necessary before a national apprenticeship program could be implemented, causing delays in the program’s commencement. As a result, students experienced longer wait times before starting their apprenticeship component. The apprenticeship program officially launched on September 14, 2021. The success of the State of Oregon’s apprenticeship program, the first of its kind in the state, underscored the flexibility and effectiveness of local initiatives compared to federal efforts. The COVID-19 pandemic also significantly impacted the project’s success. Beginning in March 2020, the pandemic led to widespread closures of schools and colleges by fall 2020. By September 2021, when the apprenticeship option became available, enrollment in colleges and universities nationwide had decreased, affecting student participation in the program. Moreover, as employers transitioned their employees to remote work, there was limited interaction with external personnel, influencing the willingness of training agents (employers) to integrate additional workers into their teams. This paper addresses several challenges encountered during the project, with the hope that future workforce development efforts will benefit from these experiences. We Final Technical Report 4 | Page encourage others to engage with state and federal agencies to enhance and update pathways for workforce development and apprenticeship programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Empirical Modeling of Direct Expansion (DX) Cooling System for Multiple Research Use Cases

This study provides a general procedure to generate a direct expansion (DX) cooling coil system for a roof top unit (RTU), which is a typical heating ventilation and air-conditioning (HVAC) system for commercial buildings in the United States. Experimental data from a full-scale unoccupied 2-story commercial building is used for the HVAC modeling. The regression for identifying the model coefficients was carried out with multiple stages, and the results were validated with measured data. The model’s applicability was evaluated with multiple case studies, including a building energy simulation (BES) program validation, model-based predictive control (MPC), and fault diagnostics and detection (FDD).

42 ENGINEERING↗

Integrated and Advanced Lighting Controls: The Next Frontier in Energy Savings?

Lighting energy use has significantly declined as a portion of overall building energy usage due largely to the uptake of more efficient light-emitting diode technology. Although the per unit cost of lighting controls has declined, the installation and use of lighting controls are low and the installation and use of advanced controls are abysmally low. Increased use of advanced and connected lighting controls, and the ability to integrate lighting with other building systems (e.g., heat and air, plug loads, miscellaneous loads) that make the building “smarter,” offer the potential for additional energy savings. Studies into the performance of new, advanced lighting control technologies in commercial buildings have generated new findings. Although each field evaluation has interesting results individually, an analysis of their collective findings across a spectrum of commercial building types will help establish the current state of the technology and implications related to market readiness. This paper will analyze results from available field evaluation studies (recently completed as well as ongoing) of retrofit sites and share findings and insights including: • The amount of energy savings that may be expected from these systems. • Cost effectiveness, monetization, and cost points of these systems. • Ideal characteristics of these systems the most viable. • Lessons learned from the installation, commissioning, and occupant response of these systems. The results will support Department of Energy research investments and help inform efficiency programs of the potential of these emerging technologies and how they may fit within the clean energy future.

Myer, Michael↗

Using non-invasive MEMS pressure sensors for measuring building envelope air leakage

Micro-electromechanical systems (MEMS)-based sensors have seen significant improvements in accuracy and cost over the past several years, and due to the need for altitude sensing in unmanned aerial vehicles and wearable technologies, absolute pressure sensors have shown the most dramatic improvements. This paper investigates applications of MEMS sensors in commercial buildings, including pairing two absolute pressure sensors to determine differential pressures between different locations in and around buildings. Differential pressure measurements are commonly made in commercial buildings for a number of applications, including static pressure measurements for variable-speed supply fan control, air balancing in hospitals, and for envelope and duct air leakage testing. This paper focuses specifically on envelope air-leakage testing applications of these sensors. The use of continuous pressure measurements in addition to one-time non-intrusive outdoor airflow measurements of rooftop packaged units is investigated. A comparison with standardized leakage testing indicated that continuous measurements with MEMS pressure-sensors were able to estimate envelope leakage to within 3–16% of the standardized test result. In addition, the magnitude and stability of differential pressure differences that can be resolved with absolute pressure sensors are also investigated in the laboratory and the field. Results show that the sensors can be effectively used for pressures seen in low rise buildings with rooftop units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

Enhancing Performance Contracts with Monitoring-Based Commissioning (MBCx)

Integrating monitoring-based commissioning (MBCx) software tools into performance contracts is a timely topic given recent developments in MBCx software offerings and the growing number of MBCx deployments nationwide. Many commercial building owners have started to install MBCx software tools that tie in advanced metering infrastructure, building automation systems, and local weather data to enable ongoing commissioning and identify energy conservation measures. To support federal and commercial building owners in understanding, procuring, and implementing MBCx software tools, this report provides an overview of their capabilities, the MBCx process, and how MBCx can be integrated into - and benefit - each phase of a performance contract. This report is intended to spur increased use of MBCx in performance contracts, whether an agency has previously installed or is considering adding MBCx at the time of their project. Additionally, case studies illustrate successful experiences using MBCx within performance contracts at a university campus and across a large number of buildings managed by the General Services Administration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Artificial Intelligence for Enhancing Multiscale Analysis: Buildings Focus

This project aims to develop multi-scale building energy data, potentially improving the representation of the U.S. buildings sector in GCAM-USA, an U.S.-focused human-energy-Earth systems model. Existing building energy datasets are typically limited to national or regional levels, which constrains the ability of models to capture fine-scale human-energy-Earth systems interactions and reduces their relevance for decision-making on issues such as energy security, resilience, and energy planning. By leveraging AI and advanced data integration methods, this work fuses multiple existing datasets to enhance the physical and geographic representation of both residential and commercial building energy use. So far, progress includes processing residential building data, designing the data structure for commercial buildings, and testing AI approaches for integrating datasets and addressing spatial-temporal gaps. This effort can not only advances GCAM-USA’s capability in modeling the buildings sector but also supports broader DOE missions, such as developing digital testbeds, enhancing grid resilience analysis, and improving building–energy system modeling at decision-relevant scales.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗