Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Evaluation of inter-laminar shear strength of GFRP composed of bonded glass/polyimide tapes and cyanate-ester/epoxy blended resin for ITER TF coils

The insulation system of the ITER TF coils consists of multi-layer glass/polyimide tapes impregnated a cyanate-ester/epoxy resin. The ITER TF coils are required to withstand an irradiation of 10 MGy from gamma-ray and neutrons since the ITER TF coils is exposed by fast neutron (>0.1 MeV) of 10{sup 22} n/m{sup 2} during the ITER operation. Cyanate-ester/epoxy blended resins and bonded glass/polyimide tapes are developed as insulation materials to realize the required radiation-hardness for the insulation of the ITER TF coils. To evaluate the radiation-hardness of the developed insulation materials, the inter-laminar shear strength (ILSS) of glass-fiber reinforced plastics (GFRP) fabricated using developed insulation materials is measured as one of most important mechanical properties before/after the irradiation in a fission reactor of JRR-3M. As a result, it is demonstrated that the GFRPs using the developed insulation materials have a sufficient performance to apply for the ITER TF coil insulation.

07 ISOTOPE AND RADIATION SOURCES↗

High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range

In several low-field Nuclear Magnetic Resonance (LF-NMR) and surface nuclear magnetic resonance applications, i.e., in the frequency range of kHz, high sensitivity magnetic field detectors are needed. Usually, low-T{sub c} superconducting quantum interference devices (SQUIDs) with a high field sensitivity of about 1 fT/Hz{sup 1/2} are employed as detectors. Considering the flux trapping and operational difficulties associated with low-T{sub c} SQUIDs, we designed and fabricated liquid-nitrogen-cooled Cu coils for NMR detection in the kHz range. A cooled coil system consisting of a 9-cm diameter Cu coil and a low noise preamplifier was systematically investigated and reached a sensitivity of 2 fT/Hz{sup 1/2} at 77 K, which is 3 times better compared to the sensitivity at 300 K. A Q-switch circuit as an essential element for damping the ringing effects of the pickup coil was developed to acquire free induction decay signals of a water sample with minimum loss of signal. Our studies demonstrate that cooled Cu coils, if designed properly, can provide a comparable sensitivity to low-T{sub c} SQUIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

Record magnetic field generation by short-pulse laser-driven capacitor-coil targets

Magnetic fields generated by capacitor-coil targets driven by intense short-pulse lasers have been characterized using ultrafast proton radiography. A 1-kJ, 15-ps laser at a center wavelength of 1053 nm irradiated the back plate of the capacitor with an intensity of ∼8.3 × 10 18 W/cm 2 , creating ultra large currents in the connecting coils. High-quality proton data obtained in the axial probing geometry show definitive signatures of magnetic field generation, allowing precision measurement of the field distribution and strength. The data show a coil current of 120 ± 10 kA producing 200 ± 20 Tesla magnetic fields at the coil center at 1.127 ns after the laser drive. In conclusion, this sets a record for magnetic field generation by the short-pulse-powered capacitor-coil targets.

Gao, Lan [Princeton Plasma Physics Laboratory (PPP↗

High-field quench behavior and dependence of hot spot temperature on quench detection voltage threshold in a Bi 2 Sr 2 CaCu 2 O x coil

Here, small insert coils have been built using a multifilamentary Bi 2 Sr 2 CaCu 2 O x round wire, and characterized in background fields to explore the quench behaviors and limits of Bi 2 Sr 2 CaCu 2 O x superconducting magnets, with an emphasis on assessing the impact of slow normal zone propagation on quench detection. Using heaters of various lengths to initiate a small normal zone, a coil was quenched safely more than 70 times without degradation, with the maximum coil temperature reaching 280 K. Coils withstood a resistive voltage of tens of mV for seconds without quenching, showing the high stability of these coils and suggesting that the quench detection voltage shall be greater than 50 mV to not to falsely trigger protection. The hot spot temperature for the resistive voltage of the normal zone to reach 100 mV increases from ~40 K to ~80 K with increasing the operating wire current density J o from 89 A/mm -2 to 354 A/mm -2 whereas for the voltage to reach 1 V, it increases from ~60 K to ~140 K, showing the increasing negative impact of slow normal zone propagation on quench detection with increasing J o and the need to limit the quench detection voltage to < 1 V. These measurements, coupled with an analytical quench model, were used to access the impact of the maximum allowable voltage and temperature upon quench detection on the quench protection, assuming to limit the hot spot temperature to <300 K.

43 PARTICLE ACCELERATORS↗

Measuring magnetic fields in laser-driven coils with dual-axis proton deflectometry

Abstract By driving hot electrons between two metal plates connected by a wire loop, high power lasers can generate multi-tesla, quasi-static magnetic fields in miniature coil targets. Many experiments involving laser-coil targets rely on proton deflectometry directed perpendicular to the coil axis to extract a measurement of the magnetic field. In this paper, we show that quantitative measurements using perpendicular probing are complicated by the presence of GV m −1 electric fields in the target that develop on sub-ns timescales. Probing parallel to the coil axis with fiducial grids is shown to reliably separate the electric and magnetic field measurements, giving current estimates of I ≈ 5 kA in 1 mm- and 2 mm-diameter wire loops. An analytic model of proton deflection in electric and magnetic fields is used to benchmark results from the particle-in-cell code and help deconvolve the magnetic and electric field deflections. Results are used to motivate a new experimental scheme that combines a single-plate target with axial proton probing and direct current measurements. This scheme has several important advantages over the traditional target and diagnostic set-up, enabling the robust measurement of coil magnetic fields and plasma properties, as well as making it easier to validate different theoretical models at a range of laser intensities.

Bradford, P. (ORCID:0000000296186342)↗

An experimental study to investigate magnetic field and winding force-dependent contact resistance of NI REBCO coil

Abstract This paper reports the magnetic field and winding force-dependent contact resistance, also known as characteristic resistance, of no-insulation (NI) REBCO coil. Three NI coils were wound with different winding forces ( < 1 kgf, 3 kgf, and 5 kgf) using the same REBCO-coated conductor, and they were tested at 4.2 K in a background field of 0, 5, 10, and 14 T. The contact resistance of each coil is measured at each field. As a result of the measurements, we draw two conclusions. First, a quadratic function for magnetic field intensity reasonably reproduces the measurement results of each NI test coil’s magnetic field-dependent contact resistance, where the practical fit function’s coefficients are determined depending on the winding force. Second, the contact resistance of each coil is partially inconsistent with the magnetoresistance of the electroplated material, i.e. copper, of the REBCO-coated conductor. This paper will present the measurement results in detail, discuss them with Kohler’s rule, and formulate the contact resistance using winding force and magnetic field terms.

Bang, Jeseok (ORCID:0000000247616334)↗

Coil Power Density Optimization and Trade-off Study for a 100kW Electric Vehicle IPT Wireless Charging System

This paper presents a trade–off study examining the impacts of modifying resonant frequency and coil current density on coil power density for a 100kW electric vehicle charging system. We find that power density can be increased significantly by moving to higher operating frequency and current density with marginal impact to overall coil–to–coil transfer efficiency. A detailed prototype model of a 150 kVA rated coil set is presented along with loss estimates from magnetic field simulations and initial test results up to 50kW.

Pries, Jason↗

Spaced Orthocyclic Winding Pattern for Improved Die Compressed Coils

Winding fill, coil fill, or packing factor, is critical to the performance of many types of electromagnetic devices from electric machines to actuators, transformers, inductors, etc. One technique to increase the packing of conductors in the winding area is to compress round magnet wire conductors in a die, so that they deform and air voids between coil turns are removed. The winding layout of the coil turns on a bobbin before compression has a direct impact on the achievable coil fill and the damage to the coil insulation or conductors after compression. It is thought that winding the turns in an orthocyclic pattern on the bobbin before compression would minimize damage to the turns. This however causes turns to displace during the winding compression process. A new pre-compression winding pattern is proposed, a spaced orthocyclic winding, to minimize turn displacement and damage. A design of experiments study has been carried out to optimize this winding method and to compare it to the traditional orthocyclic winding.

33 ADVANCED PROPULSION SYSTEMS↗

Encapsulation Residual Stress and Ferrite Loss in Inductive Coil Assemblies

As inductive wireless charging reaches higher power levels, thermal management and mechanical durability become more critical. To address these concerns, past works have demonstrated the benefit of encapsulating coil assemblies in thermally conductive materials. However, due to the sensitivity of the MnZn ferrites commonly used in coil assemblies to mechanical stress, care must be taken to avoid creating large stresses in the ferrite that cause higher hysteresis loss. The stress formation in the encapsulant curing process is overviewed and modeled and an experiment is performed to demonstrate the effect in a small-scale coil assembly. Finally, the effect is shown in the reduced coil-coil efficiency of a first generation high power inductive power transfer prototype using a stiff epoxy compared to better performance in a second prototype using a softer thermally-conductive silicone encapsulant.

Foote, Andrew↗

Design of High-Power Polyphase PCB Coil Systems for Wireless Power Transfer

Printed circuit board (PCB) coils have been proposed prior for implementation as inductive wireless charging coils to minimize size and cost. Utilization of PCBs can allow for a reduced cost, improved manufacturability, and a wide range of geometric customization options. To circumvent material limitations on insulation and thermal performance, parallel paths can be implemented to divide the current per path accordingly. Within this paper, an unconventional high-power PCB coil is designed employing all possible techniques for wiring with axial and radial parallel paths with equivalent transposition to minimize circulating currents. Design studies are simulated in 3D finite element analysis (FEA) to evaluate imbalance between phases with and without transposition. Two experimental prototype coils were fabricated with measurements for self-inductance and mutual inductance between phases. These measurements were validated to be sufficiently consistent with FEA results. Additionally, a method is proposed for a two-step optimization of coupling coefficient and coil losses.

Lewis, Donovin D.↗

Thermal Analysis of Wireless Power Transfer Coils for Dynamic Wireless Electric Vehicle Charging

In this paper, safe operating conditions of a wireless power transfer coil were identified and road infrastructure for a dynamic wireless electric vehicle charging system was studied. Magneto-thermal simulations were used to map the power loss directly into the computed fluid dynamics solver. This method allowed the authors to analyze the heating pattern of the enclosed wireless power transfer coil in the road structure, as well as for the vehicle coil. Thermal heating patterns for three types of rectangular coil structures were analyzed. Heating patterns were analyzed for 200 kW coils and different magnetic field densities in the magnetic core.

Wojda, Rafal↗

Comparison of Magnetic Field Emission from Unipolar and Bipolar Coil-Based Wireless Charging Systems

In this study, the leakage magnetic field (LMF) from the unipolar (circular, rectangular, etc.) and bipolar (double-D) coil-based wireless charging systems (WCSs) are investigated and compared. The unipolar and bipolar pads, which are the two most widely adopted charging-pads, have significantly different magnetic field emission characteristics. In this paper, the spatial-distribution and vector-pattern of the leakage magnetic field are studied and compared for similar 11 kW unipolar and bipolar coil-based WCSs. The field emissions are simulated using finite element analysis (FEA) and tested experimentally with an 11 kW bipolar coil-based WCS prototype. The results show that the leakage magnetic field of the unipolar and bipolar pads have widely different vector-orientation and spatial distributions of the leakage magnetic field. The results show that the unipolar coil based WCS has a dominant vertical and the bipolar pads coil-based WCS has dominant horizontally aligned leakage magnetic field. Considering the shielding, the aluminum plate is found highly effective for the unipolar pad and almost ineffective for bipolar pads.

Mohammad, Mostak↗

Design and Performance Assessment of Intermediary Coils for Misalignment Tolerance Improvement in Wireless Power Transfer Systems

This paper investigates the use of intermediate coils positioned between the primary and secondary coils in Wireless Power Transfer (WPT) systems for electric vehicle (EV) charging, with the objective of improving power transfer efficiency and robustness under misalignment conditions. An optimized 1 kW power system that operates at 85 kHz is developed and the misalignment performance was analyzed and compared with and without intermediate coils. A preliminary increase in efficiency of 2.3% at a misalignment of 52% of the coil radius is shown to be possible for a passive intermediate coil. An experimental prototype is built for design verification.

Sivka, Gozde [ORNL]↗

Status of Long Coil Production for the MQXFB Nb3Sn Prototype Quadrupole for the HiLumi LHC

The High luminosity LHC upgrade target is to increase the integrated luminosity by a factor 10, resulting in an integrated luminosity of 3000 fb-1. One major improvement foreseen is the reduction of the beam size at the collision points. This requires the development of 150 mm single aperture quadrupoles for the interaction regions. These quadrupoles are under development in a joint collaboration between CERN and the US-LHC Accelerator Research Program (LARP). The chosen approach for achieving a nominal quadrupole field gradient of 132.6 T/m is based on the Nb3Sn technology. The coils with a length of 7281 mm will be the longest Nb3Sn coils fabricated so far for accelerator magnets. The production of the long coils was launched in 2016 based on practise coils made from copper. This paper provides a status of the production of the first low grade and full performance coils and describes the production process and applied quality control. Furthermore an outlook for the prototype assembly is provided.

43 PARTICLE ACCELERATORS↗

Electromagnetic Interaction between the Component Coils of Multi-Plex Magnets

Ultra-high field pulsed magnets are usually designed as a group of nested, concentric coils driven by separated power sources to reduce the required driving voltages and to distribute the mechanical load and to reduce the driving voltages. Since the magnet operates in a fast transient mode, there will be strong and complicated electromagnetic couplings between the component coils. The high eddy currents generated in the reinforcement shells of the component coils during the pulses also strongly affect these couplings. Therefore, understanding the electromagnetic interaction between the component coils will allow safer, more optimized design and operation of our magnets. As a result, this paper will focus on our finite element modeling and experimental results for the electromagnetic interactions between the component coils of the 100-T nondestructive magnet and 80-T duplex magnet at our facility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Elliptic Aperture CCT Coils for HTS Dipole Magnets

High-temperature REBa$_{2}$Cu$_{3}$O$_{7-x}$ (REBCO) superconductors are a route to increase the field of accelerator magnets beyond the 15-16T practical limit of Nb$_{3}$Sn. REBCO cabled in a CORC geometry is a promising fit for this application, enabling the design of low inductance magnets with conductor transposition. However, the use of CORC in coils with the tight conductor bending radii typical of accelerator magnets remains a key challenge, with on-going research both on the conductor development and coil design fronts seeking to address this issue. Here, in this work we explore the tradeoffs between circular and elliptic aperture canted-cosine-theta (CCT) coils when the conductor minimum bending radius is a key consideration, concluding that aperture ellipticity is an important free parameter in the optimization of magnetically efficient CORC dipole magnets. In particular, we show that elliptic bore designs enable a regime of smaller aperture HTS coils, an important result for LTS-HTS hybrid magnets and more generally for accelerator applications benefiting from non-circular magnet apertures. To this end we present an elliptic aperture dipole design optimized for hybrid testing within the US Magnet Development Program (US-MDP) and share 77 K test results of a prototype coil which provides first experimental confirmation of the advantages.

Brouwer, L. [Lawrence Berkeley National Laboratory↗

Sci—Thur AM: YIS - 08: Constructing an Attenuation map for a PET/MR Breast coil

In 2013, around 23000 Canadian women and 200 Canadian men were diagnosed with breast cancer. An estimated 5100 women and 55 men died from the disease. Using the sensitivity of MRI with the selectivity of PET, PET/MRI combines anatomical and functional information within the same scan and could help with early detection in high-risk patients. MRI requires radiofrequency coils for transmitting energy and receiving signal but the breast coil attenuates PET signal. To correct for this PET attenuation, a 3-dimensional map of linear attenuation coefficients (μ-map) of the breast coil must be created and incorporated into the PET reconstruction process. Several approaches have been proposed for building hardware μ-maps, some of which include the use of conventional kVCT and Dual energy CT. These methods can produce high resolution images based on the electron densities of materials that can be converted into μ-maps. However, imaging hardware containing metal components with photons in the kV range is susceptible to metal artifacts. These artifacts can compromise the accuracy of the resulting μ-map and PET reconstruction; therefore high-Z components should be removed. We propose a method for calculating μ-maps without removing coil components, based on megavoltage (MV) imaging with a linear accelerator that has been detuned for imaging at 1.0MeV. Containers of known geometry with F18 were placed in the breast coil for imaging. A comparison between reconstructions based on the different μ-map construction methods was made. PET reconstructions with our method show a maximum of 6% difference over the existing kVCT-based reconstructions.

60 APPLIED LIFE SCIENCES↗