Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CoNNECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Parametric Finite-Element Model for Evaluating Segmented Mirrors with Discrete, Edgewise Connectivity

Since future astrophysics missions require space telescopes with apertures of at least 10 meters, there is a need for on-orbit assembly methods that decouple the size of the primary mirror from the choice of launch vehicle. One option is to connect the segments edgewise using mechanisms analogous to damped springs. To evaluate the feasibility of this approach, a parametric ANSYS model that calculates the mode shapes, natural frequencies, and disturbance response of such a mirror, as well as of the equivalent monolithic mirror, has been developed. This model constructs a mirror using rings of hexagonal segments that are either connected continuously along the edges (to form a monolith) or at discrete locations corresponding to the mechanism locations (to form a segmented mirror). As an example, this paper presents the case of a mirror whose segments are connected edgewise by mechanisms analogous to a set of four collocated single-degree-of-freedom damped springs. The results of a set of parameter studies suggest that such mechanisms can be used to create a 15-m segmented mirror that behaves similarly to a monolith, although fully predicting the segmented mirror performance would require incorporating measured mechanism properties into the model. Keywords: segmented mirror, edgewise connectivity, space telescope

Gersh-Range, Jessica A.↗

Implementing Connected Component Labeling as a User Defined Operator for SciDB

We have implemented a flexible User Defined Operator (UDO) for labeling connected components of a binary mask expressed as an array in SciDB, a parallel distributed database management system based on the array data model. This UDO is able to process very large multidimensional arrays by exploiting SciDB's memory management mechanism that efficiently manipulates arrays whose memory requirements far exceed available physical memory. The UDO takes as primary inputs a binary mask array and a binary stencil array that specifies the connectivity of a given cell to its neighbors. The UDO returns an array of the same shape as the input mask array with each foreground cell containing the label of the component it belongs to. By default, dimensions are treated as non-periodic, but the UDO also accepts optional input parameters to specify periodicity in any of the array dimensions. The UDO requires four stages to completely label connected components. In the first stage, labels are computed for each subarray or chunk of the mask array in parallel across SciDB instances using the weighted quick union (WQU) with half-path compression algorithm. In the second stage, labels around chunk boundaries from the first stage are stored in a temporary SciDB array that is then replicated across all SciDB instances. Equivalences are resolved by again applying the WQU algorithm to these boundary labels. In the third stage, relabeling is done for each chunk using the resolved equivalences. In the fourth stage, the resolved labels, which so far are "flattened" coordinates of the original binary mask array, are renamed with sequential integers for legibility. The UDO is demonstrated on a 3-D mask of O(1011) elements, with O(108) foreground cells and O(106) connected components. The operator completes in 19 minutes using 84 SciDB instances.

UDO↗

Saturn's Plasma Density Depletions Along Magnetic Field Lines Connected to the Main Rings

We report on a set of clear and abrupt decreases in the high-frequency boundary of whistlerode emissions detected by Cassini at high latitudes (about ±40°) during the low-altitude proximal flybys f Saturn . These abrupt decreases or dropouts have start and stop locations that correspond to L shells at the dges of the A and B rings. Langmuir probe measurements can confirm, in some cases, that the abrupt decrease in the high-frequency whistler mode boundary is associated with a corresponding abrupt electron density dropout over evacuated field lines connected to the A and B rings. Wideband data also reveal electron plasma oscillations and whistler mode cutoffs consistent with a low-density plasma in the region. he observation of the electron density dropout along ring-connecting field lines suggests that strong ambipolar forces are operating, drawing cold ionospheric ions outward to fill the flux tubes. There is an analog with the refilling of flux tubes in the terrestrial plasmasphere. We suggest that the ring-connected electron density dropouts observed between 1.1 and 1.3 R(sub s) are connected to the low-density ring plasma cavity observed overtop the A and B rings during the 2004 Saturn orbital insertion pass.

Farrell, W. M.↗

Slow Solar Wind Connection Science during Solar Orbiter's First Close Perihelion Passage

The Slow Solar Wind Connection Solar Orbiter Observing Plan (Slow Wind SOOP) was developed to utilize the extensive suite of remote-sensing and in situ instruments on board the ESA/NASA Solar Orbiter mission to answer significant outstanding questions regarding the origin and formation of the slow solar wind. The Slow Wind SOOP was designed to link remote-sensing and in situ measurements of slow wind originating at open–closed magnetic field boundaries. The SOOP ran just prior to Solar Orbiter's first close perihelion passage during two remote-sensing windows (RSW1 and RSW2) between 2022 March 3–6 and 2022 March 17–22, while Solar Orbiter was at respective heliocentric distances of 0.55–0.51 and 0.38–0.34 au from the Sun. Coordinated observation campaigns were also conducted by Hinode and IRIS. The magnetic connectivity tool was used, along with low-latency in situ data and full-disk remote-sensing observations, to guide the target pointing of Solar Orbiter. Solar Orbiter targeted an active region complex during RSW1, the boundary of a coronal hole, and the periphery of a decayed active region during RSW2. Postobservation analysis using the magnetic connectivity tool, along with in situ measurements from MAG and SWA/PAS, showed that slow solar wind originating from two out of three of the target regions arrived at the spacecraft with velocities between ∼210 and 600 km s −1 . The Slow Wind SOOP, despite presenting many challenges, was very successful, providing a blueprint for planning future observation campaigns that rely on the magnetic connectivity of Solar Orbiter.

Slow solar wind↗

Single bus star connected reluctance drive and method

A system and methods for operating a switched reluctance machine includes a controller, an inverter connected to the controller and to the switched reluctance machine, a hysteresis control connected to the controller and to the inverter, a set of sensors connected to the switched reluctance machine and to the controller, the switched reluctance machine further including a set of phases the controller further comprising a processor and a memory connected to the processor, wherein the processor programmed to execute a control process and a generation process.

33 ADVANCED PROPULSION SYSTEMS↗

A QCQP Approach for OPF in Multiphase Radial Networks with Wye and Delta Connections: Preprint

This paper examines the AC Optimal Power Flow (OPF) problem for multiphase distribution networks featuring renewable energy resources (RESs). We start by outlining a power flow model for radial multiphase systems that accommodates wye-connected and delta-connected RESs and non-controllable energy assets. We then formalize an AC OPF problem that accounts for both types of connections. Similar to various AC OPF renditions, the resultant problem is a non convex quadratically-constrained quadratic program. However, the so-called Feasible Point Pursuit-Successive Convex Approximation algorithm is leveraged to obtain a feasible and yet locally-optimal solution. The merits of the proposed solution approach are demonstrated using two unbalanced multiphase distribution feeders with both wye and delta connections.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Switch-connected HyperX network

A network system includes a plurality of sub-network planes and global switches. The sub-network planes have a same network topology as each other. Each of the sub-network planes includes edge switches. Each of the edge switches has N ports. Each of the global switches is configured to connect a group of edge switches at a same location in the sub-network planes. In each of the sub-network planes, some of the N ports of each of the edge switches are connected to end nodes, and others of the N ports are connected to other edge switches in the same sub-network plane, other of the N ports are connected to at least one of the global switches.

42 ENGINEERING↗

Temperature control to reduce capacity mismatch in parallel-connected lithium ion cells

The temperature and capacity of individual cells affect the current distribution in a battery pack. Non uniform current distribution among parallel-connected cells can lead to capacity imbalance and premature aging. This paper develops models that calculate the current in parallel-connected cells and predict their capacity fade. The model is validated experimentally for a nonuniform battery pack at different temperatures. The paper also proposes and validates the hypothesis that temperature control can reduce capacity mismatch in parallel-connected cells. Three Lithium Iron Phosphate cells, two cells at higher initial capacity than the third cell, are connected in parallel. The pack is cycled for 1500 Hybrid Electric Vehicles cycles with the higher capacity cells regulated at 40 C and the lower capacity cell at 20 C. As predicted by the model, the higher capacity and temperature cells age faster, reducing the capacity mismatch by 48% over the 1500 cycles. A case study shows that cooling of low capacity cells can reduce capacity mismatch and extend pack life.

25 ENERGY STORAGE↗

We Just Want to Pump…You Up! Forecasting Grid-Connected Heat Pump Water Heater Energy Savings and Load Shifting Potential for the Southeast U.S.

Heat pump water heaters (HPWH) can achieve energy savings of 60-70% compared to conventional electric-resistance water heaters. However, even with a favorable simple payback period within the typical product lifetime, HPWHs make up only 1% of all electric water heaters sold in the residential sector. Market adoption is challenged, in part, by the lack of effective energy efficiency programs in the U.S. region with the greatest amount of residential electric water heaters. The recent integration of connected functionality into HPWHs offers the capability to shift load without undue negative impact on customers. This capability can provide value to utilities with peak load constraints, motivating them to promote HPWHs for the first time. This paper will present a methodology to forecast connected HPWH energy use and extrapolate load shifting potential for the Southeast U.S. region. The methodology leverages data from a robust connected HPWH field study conducted in the Pacific Northwest. A coefficient of performance (COP) relationship for HPWHs was developed using ambient and inlet water temperature data to forecast HPWH performance on a month-by-month basis. Using the forecasted COP, HPWH operating hours were calculated for meeting load, which serve as the proxy to extrapolate load shifting potential from the Pacific Northwest to the Southeast. As a use case, analytical results are presented for a specific utility. This methodology, in combination with market analysis, facilitates the development of customized energy savings and load shifting forecasts to understand the potential impacts of launching connected HPWH programs in specific utility service territories.

heat pump water heater, energy savings, load shift↗

Hermetic edge-connect headers and corresponding connectors

A hermetically-sealed edge-connect header that can withstand high temperatures, high pressures (or high vacuum levels), and high vibration environments, along with two corresponding connectors are disclosed. After brazing the edge-connect header components, the assembly is machined to form a slot with a portion of each of a plurality of electrical conductors removed in the machining process, resulting in a header with a high pin density. During the process of mating the first connector design to the edge-connect header, a plurality of wipers in the connector deflect, thereby causing the wipers to extend from the connector and contact the corresponding electrical conductors in the header. During the process of mating the second connector design to the edge-connect header, each of a plurality of wipers formed of low-mass, compliant metal wool, forms multiple contact points with a corresponding electrical conductor in the header.

Kellogg, Rick A.↗

Hermetic edge-connect headers and corresponding connectors

A hermetically-sealed edge-connect header that can withstand high temperatures, high pressures (or high vacuum levels), and high vibration environments, along with two corresponding connectors are disclosed. After brazing the edge-connect header components, the assembly is machined to form a slot with a portion of each of a plurality of electrical conductors removed in the machining process, resulting in a header with a high pin density. During the process of mating the first connector design to the edge-connect header, a plurality of wipers in the connector deflect, thereby causing the wipers to extend from the connector and contact the corresponding electrical conductors in the header. During the process of mating the second connector design to the edge-connect header, each of a plurality of wipers formed of low-mass, compliant metal wool, forms multiple contact points with a corresponding electrical conductor in the header.

Kellogg, Rick A.↗

Connecting Electric Vehicle Charging Infrastructure to Commercial Buildings

Electric vehicles (EVs) are growing in popularity and gaining meaningful market share with record sales year over year in the last decade. EV charging equipment, also known as EV chargers (EVC) or EV supply equipment (EVSE), must proportionally match the growing number of new EVs on the road for a comparable experience to gas-powered vehicles. The majority of EV charging currently happens at residential buildings. However, demand for EV charging at commercial buildings will significantly increase with wider mainstream EV adoption and as businesses return to more normal operation following COVID-19 pandemic disruptions. Charging equipment can include various sub-systems like power conditioning module, control software, safety devices, metering, communication, cooling, connectors, and its wiring. EV charging at commercial buildings could be used for public, workplace, and commercial fleet charging. This document aims to describe how EVC can be connected to commercial buildings, including considerations for facility managers, and the effects that charging will have on the buildings electrical distribution system. More specifically, this resource provides an overview of: understanding EV charging basics: how charging equipment connects to the building and to EVs; required infrastructure updates needed at the building site to connect EVC to existing distribution systems; network strategies for cost-effective operation; metering and utility considerations for billing and incentives; charging equipment ownership options; future trends in EVC connection to buildings.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Hermetic edge-connect headers and corresponding connectors

A hermetically-sealed edge-connect header that can withstand high temperatures, high pressures (or high vacuum levels), and high vibration environments, along with two corresponding connectors are disclosed. After brazing the edge-connect header components, the assembly is machined to form a slot with a portion of each of a plurality of electrical conductors removed in the machining process, resulting in a header with a high pin density. During the process of mating the first connector design to the edge-connect header, a plurality of wipers in the connector deflect, thereby causing the wipers to extend from the connector and contact the corresponding electrical conductors in the header. During the process of mating the second connector design to the edge-connect header, each of a plurality of wipers formed of low-mass, compliant metal wool, forms multiple contact points with a corresponding electrical conductor in the header.

Kellogg, Rick A.↗

A series of pure inorganic eight-connected self-catenated network based on Silverton-type polyoxometalate

In this paper, three pure inorganic eight-connected self-catenated networks based on the Silverton-type polyoxometalate [CeMo{sub 12}O{sub 42}]{sup 8-} with lanthanide, transition metal and alkali metal cations as linkers: [Li(H{sub 2}O){sub 4}]{sub 2}Co(H{sub 2}O){sub 4}Ce(H{sub 2}O){sub 3}[CeMo{sub 12}O{sub 42}].3H{sub 2}O (1), H{sub 0.5}[Li(H{sub 2}O){sub 4}]{sub 2.5}[Ni(H{sub 2}O){sub 4}]{sub 0.5}Ce(H{sub 2}O){sub 3}[CeMo{sub 12}O{sub 42}].3H{sub 2}O (2) and H[Li(H{sub 2}O){sub 4}]{sub 3}Ce(H{sub 2}O){sub 3}[CeMo{sub 12}O{sub 42}].3H{sub 2}O (3) have been successfully synthesized and characterized by elemental analysis, IR spectroscopy, thermal gravimetric analysis, X-ray photoelectron spectroscopy, electrochemical analyses and single crystal X-ray diffraction. The single crystal X-ray diffraction analyses reveal that compounds 1-3 are isostructural. The [Ce{sup IV}Mo{sub 12}O{sub 42}]{sup 8-} polyoxoanions are connected by Ce{sup 4+} to form the infinite 1D chains. And then the parallel stacking chains linked by transition metal cations and lithium ions construct to an eight-connected self-catenated 4{sup 24}56{sup 3} topology framework. - Graphical Abstract: Three extended frameworks based on Silverton-type polyoxometalate have been successfully synthesized. In these compounds, [Ce{sup IV}Mo{sub 12}O{sub 42}]{sup 8-} clusters are connected by lanthanide, transition metal and Li{sup +} to form a 4{sup 24}56{sup 3} network.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Design and dispatch optimization of packaged ice storage systems within a connected community

The traditional implementation of cool thermal energy storage (CTES) must be reimagined within the context of a dynamic grid and smart buildings operating as connected communities. As most buildings do not operate central chillers or connect to district cooling loops, this necessitates a broader use of packaged CTES. Our objective is to begin answering the question of how such packaged CTES should be implemented within a connected community. We do so by presenting a simulation–optimization workflow employing building energy modeling software and a mixed-integer linear program to design and dispatch a packaged CTES technology to achieve minimum total annual cost. We demonstrate this methodology on a seven-building case study using current utility rates and find that total annual cooling energy costs can be reduced by 17.8% compared to baseline, after accounting for the cost of storage. We perform three parametric sensitivity studies to evaluate modeling assumptions and obtain the prioritization of storage procurement as a function of annualized life-cycle cost of storage. We find that a community optimization approach provides significantly different results than individual building optimizations and provides greater savings compared to baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The cross-aisle seismic performance of storage rack base connections

Steel storage racks used in retail stores and warehouses are seismically designed as moment resisting frames in the down-aisle direction, and braced frames in the cross-aisle direction. While their down-aisle response is relatively well understood, there is little understanding of their cross-aisle response, especially as it pertains to the desired mode of inelastic deformation and associated design methods. In this paper, results are presented from six full scale tests on braced frames representing storage racks in the cross-aisle direction. These tests investigate the base plate thickness and dimensions, and the upright (column) cross section. The experiments indicate that inelastic deformation in the base plate provides stable hysteretic response with significant ductility and energy dissipation. Ductile tearing is also observed in welds connecting the base plate to the upright. However, it does not appear to negatively influence the hysteretic response. The tests are complemented by Finite Element (FE) simulations of the base connections. These simulations provide insights into internal force distributions within the connections. Based on these insights, analytical equations are proposed for characterizing the backbone curve of the hysteretic response, for use in displacement based design methods. It is determined that the current approach for characterizing design forces in the anchors is unconservative, since it does not incorporate the effects of strain hardening or the membrane action as the base plate undergoes large deformations. A new approach which incorporates these phenomena is presented, and determined to be significantly more accurate. Finally, limitations of the study are outlined and directions for future work are identified.

36 MATERIALS SCIENCE↗

At the interfaces of the hydrologic sciences: Connecting water, elements, ecosystems, and people through the major contributions of Dr. Emily Bernhardt

Here, in this paper, we describe the major contributions of Professor Emily Bernhardt to the hydrologic sciences. Dr. Bernhardt’s work addresses how carbon, nutrient, and contaminant dynamics respond to a wide range of environmental perturbations that alter hydrologic dynamics within and connectivity among ecosystems. Her research leverages intensive and extensive field sampling, experimental manipulations, macroscale data harmonization and exploration, and continental to global-scale synthesis activities to uncover key drivers and patterns of the impacts human perturbations have on water and elemental cycles. Dr. Bernhardt’s research program is defined by her ability to ask questions and use approaches that explicitly consider connectivity and interfaces in a variety of ways. Here, we highlight significant contributions from Dr. Bernhardt’s work, organized by connectivity, interfaces, and interactions among and across (1) elemental cycles, (2) ecosystems, (3) watersheds, (4) scales, and (5) disciplines. We conclude with a section on Dr. Bernhardt’s impact on the hydrologic sciences and beyond through her exceptional dedication to mentorship, engagement, and service.

58 GEOSCIENCES↗