Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Charger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Framework to Analyze the Requirements of a Multiport Megawatt-Level Charging Station for Heavy-Duty Electric Vehicles

Widespread adoption of heavy-duty (HD) electric vehicles (EVs) will soon necessitate the use of megawatt (MW)-scale charging stations to charge high-capacity HD EV battery packs. Such a station design needs to anticipate possible station traffic, average and peak power demand, and charging/wait time targets to improve throughput and maximize revenue-generating operations. High-power direct current charging is an attractive candidate for MW-scale charging stations at the time of this study, but there are no precedents for such a station design for HD vehicles. We present a modeling and data analysis framework to elucidate the dependencies of a MW-scale station operation on vehicle traffic data and station design parameters and how that impacts vehicle electrification. This framework integrates an agent-based charging station model with vehicle schedules obtained through real-world vehicle telemetry data analysis to explore the station design and operation space. A case study applies this framework to a Class 8 vehicle telemetry dataset and uses Monte Carlo simulations to explore various design considerations for MW-scale charging stations and EV battery technologies. The results show a direct correlation between optimal charging station placement and major traffic corridors such as cities with ports, e.g., Los Angeles and Oakland. Corresponding parametric sweeps reveal that while good quality of service can be achieved with a mix of 1.2-megawatt and 100-kilowatt chargers, the resultant fast charging time of 35–40 min will need higher charging power to reach parity with refueling times.

33 ADVANCED PROPULSION SYSTEMS↗

Mining Product Reviews for Important Product Features of Refurbished iPhones

Problem: Remanufacturers want to increase consumer interest in refurbished products, which motivates the need to understand which product features are important to buyers of refurbished products such as mobile phones. Research Questions: This study addresses two questions. First, which product features are most important for buyers of refurbished iPhones? Second, how do those preferences differ from the preferences of buyers of new iPhones? Methods: Online reviews of iPhones are obtained and converted into a document–term matrix. Using this text model, three subsets of features are identified using statistical analysis of frequency of mention: most frequent, average, and least frequent. A logistic regression (LR) model is then used to identify which features are most predictive of whether a review is for a new or refurbished phone. Results: Buyers of refurbished phones mention battery health, screen/display, shell condition, and brand significantly more often than other features. Directly contrasting reviews of refurbished versus new phones shows that shell condition, brand, speaker, and charger are found to be the most predictive product features indicated in reviews for refurbished phones. Of those, the shell condition is significantly more predictive than the others. Implications: The results identify product features that remanufacturers of iPhones can emphasize to increase customer demand.

Anisi, Atefeh↗

Impact of Regional and Seasonal Characteristics on Battery Electric Vehicle Operational Costs in the U.S.

This study investigates the operational cost competitiveness of battery electric vehicles (BEVs) in the United States, considering regional climates, energy prices, and driving patterns. By comparing BEVs with plug-in hybrid electric vehicles (PHEVs), hybrid electric vehicles (HEVs), and the alternative use of BEVs and conventional vehicles (Convs), the analysis incorporates thermal dynamometer tests, real-world vehicle miles traveled (VMT), and state-specific energy prices. Using detailed simulations, the study evaluates energy consumption across varying temperatures and driving distances. The findings reveal that, while BEVs remain cost-effective for short trips in moderate climates, PHEVs are more economical for long-range trips and cold environments, due to the excessive cost of using external direct current fast chargers (DCFCs) and reduced BEV efficiency at low temperatures. HEVs are identified as the most cost-efficient option in regions like New England, characterized by high residential electricity prices. These insights are critical for shaping vehicle electrification strategies, particularly under diverse regional and seasonal conditions, and for advancing policies on alternative energy and fuels.

Kim, Kyung-Ho (ORCID:0009000450851732)↗

Depot Charging Schedule Optimization for Medium- and Heavy-Duty Battery-Electric Trucks

Charge management, which lowers charging costs for fleets and prevents straining the electrical grid, is critical to the successful deployment of medium- and heavy-duty battery-electric trucks (MHD BETs). This study introduces an energy demand and cost management framework that optimizes depot charging for MHD BETs by combining an energy consumption machine learning model and a linear program optimization model. The framework considers key factors impacting real-world MHD BET operations, including vehicle and charger configurations, duty cycles, use cases, geographic and climate conditions, operation schedules, and utilities’ time-of-use (TOU) rates and demand charges. The framework was applied to a hypothetical fleet of 100 MHD BETs in California under three different utilities for 365 days, with results compared to unmanaged charging. The optimized charging solution avoided more than 90% of on-peak charging, reduced fleet charging peak load by 64–75%, and lowered fleet energy variable costs by 54–64%. This study concluded that the proposed charge management framework significantly reduces energy costs and peak loads for MHD BET fleets while making recommendations for fleet electrification infrastructure planning and the design of utility TOU rates and demand charges.

Song, Shuhan↗

Scaled Implementation of Smart Charge Management for Electric Vehicles

Smart charge management (SCM) has become a critical strategy for mitigating potential grid impacts and reducing electricity costs for all customers. This study will evaluate the economics of implementing light-duty EV SCM at scale across the United States. This work will enhance distribution system analysis by estimating SCM implementation costs, exploring viable business cases, and developing a framework for national-level applications. The primary methodology involves leveraging detailed grid modeling from a specific service territory and using spatial extrapolation techniques to generalize findings to other regions. The analysis will develop key metrics to quantify the costs and benefits of SCM, including implementation costs relative to strategy and scale, the cost of distribution system upgrades with and without SCM, and the percentage of peak-load reduction. The objective is to produce a comprehensive report and a parameterized framework that enables utilities to self-assess the value of SCM in their own service territories. This will support the development of cost-effective charging strategies, accelerate the energization of new EV chargers, and facilitate the seamless integration of EVs into the nation's power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Apollo experience report: Battery subsystem

Experience with the Apollo command service module and lunar module batteries is discussed. Significant hardware development concepts and hardware test results are summarized, and the operational performance of batteries on the Apollo 7 to 13 missions is discussed in terms of performance data, mission constraints, and basic hardware design and capability. Also, the flight performance of the Apollo battery charger is discussed. Inflight data are presented.

Trout, J. B.↗

Mariner Mars 1971 battery design, test, and flight performance

The design, integration, fabrication, test results, and flight performance of the battery system for the Mariner Mars spacecraft launched in May 1971 are presented. The battery consists of 26 20-Ah hermetically sealed nickel-cadmium cells housed in a machined magnesium chassis. The battery package weighs 29.5 kg and is unique in that the chassis also serves as part of the spacecraft structure. Active thermal control is accomplished by louvers mounted to the battery baseplate. Battery charge is accomplished by C/10 and C/30 constant current chargers. The switch from the high-rate to low-rate charge is automatic, based on terminal voltage. Additional control is possible by ground command or onboard computer. The performance data from the flight battery is compared to the data from various battery tests in the laboratory. Flight battery data was predictable based on ground test data.

Bogner, R. S.↗

Power subsystem performance prediction /PSPP/ computer program.

A computer program which simulates the operation of the Viking Orbiter Power Subsystem has been developed. The program simulates the characteristics and interactions of a solar array, battery, battery charge controls, zener diodes, power conditioning equipment, and the battery spacecraft and zener diode-spacecraft thermal interfaces. This program has been used to examine the operation of the Orbiter power subsystem during critical phases of the Viking mission - from launch, through midcourse maneuvers, Mars orbital insertion, orbital trims, Lander separation, solar occultations and unattended operation - until the end of the mission. A typical computer run for the first 24 hours after launch is presented which shows the variations in solar array, zener diode, battery charger, batteries and user load characteristics during this period.

Weiner, H.↗

Performance of 3rd electrode cells in OAO.

The OAO 2 satellite employed nickel-cadmium batteries with auxiliary (signal) electrodes for overcharge control. During the early life of the satellite, these third-electrode signals provided an orbit-by-orbit indication of the overcharge received by the batteries. By ground command, the battery charger was adjusted on a need basis to provide optimum recharge conditions as indicated by the third-electrode signals during all phases of spacecraft operation and orientation. After more than two years, an unusual degradation in third-electrode signals was observed, providing the first indication of battery degradation. The present paper examines the operation of the battery system and analyzes the battery degradation mechanism. The abnormal performance of the third electrode is related to cell-voltage divergence during periods of overcharge. Cells that had a higher cell voltage showed signs (third-electrode degradation) of small amounts of hydrogen gas generation.

Ford, F. E.↗

Radioisotope thermal generator (RTG) power conditioner

New regulator: (a) permits operation with high-impedance radioisotope thermal generators at conversion efficiencies typically above 90%; (b) does not require input filtering; (c) eliminates current spiking; and (d) is simple, efficient, and reliable. Converter-charger pair could be adapted for other power levels by changing transistor, diode, capacitor bank, and inductor.

Stacey, W. S.↗

Wind power demonstration and siting problems

Technical and economic feasibility studies on a small windmill to provide overnight charging for an electrically driven car are reported. The auxiliary generator provides power for heating and cooling the vehicle which runs for 25 miles on battery power alone, and for 50 miles with the onboard charger operating. The blades for this windmill have a diameter of 12 feet and are coupled through to a conventional automobile alternator so that they are able to completely recharge car batteries in 8 hours. Optimization of a windmill/storage system requires detailed wind velocity information which permits rational sitting of wind power system stations.

Bergey, K. H.↗

Terrestrial applications of FEP-encapsulated solar cell modules

The NASA-Lewis Research Center program of transferring the FEP-encapsulated solar cell technology developed for the space program to terrestrial applications is presented. The electrical power system design and the array mechanical design are described, and power systems being tested are discussed. The latter are located at NOAA-RAMOS weather stations at Sterling, Va., and Mammoth Mountain, Calif.; on the roof of the Lewis Research Center; on a NOAA-Coast Guard buoy in the Gulf of Mexico; in a U.S. Forest Service mountaintop voice repeater station in the Inyo National Forest, Calif., and in a backpack charger for portable transmitter/receivers being used in the same place. Preliminary results of testing are still incomplete, but show that rime ice can cause cracks in modular cells without damaging the FEP though, which keeps the grid lines intact, and that electrically active elements of the module must be completely sealed from salt water to prevent FEP delamination.

Forestieri, A. F.↗

Design of the High Energy Astronomy Observatory /HEAO/ power subsystem

Observatory power is generated by a partially deployable solar array which is modularized to facilitate adaptation to three missions having different power requirements. Three nickel-cadmium batteries are controlled independently from dedicated modular chargers to increase subsystem adaptability and decrease sensitivity to temperature differences between batteries. Battery level redundancy is employed, enabling mission completion with two of three battery/charger combinations operational. Bus voltage limiting is accomplished by a modularized shunt regulator which can survive any single part failure and meet all mission requirements. Relatively low shunt electronics power dissipation internal to the observatory is achieved by sequenced operation of linear shunt segments which are coupled to a large area resistive shunt radiator. Summaries of solar array, battery and subsystem breadboard test results are provided.

Reppucci, G. M.↗

Baseline tests of the power-train electric delivery van

Vehicle maximum speed, range at constant speed, range over stop-and-go driving schedules, maximum acceleration, gradeability, gradeability limit, road energy consumption, road power, indicated energy consumption, braking capability, battery charger efficiency, and battery characteristics were determined for a modified utility van powered by sixteen 6-volt batteries connected in series. A chopper controller actuated by a foot accelerator pedal changes the voltage applied to the 22-kilowatt (30-hp) series-wound drive motor. In addition to the conventional hydraulic braking system, the vehicle has hydraulic regenerative braking. Cycle tests and acceleration tests were conducted with and without hydraulic regeneration.

Lumannick, S.↗