Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design. This revision models the individual maximum fan reduced flow capacity from 38,000 cfm to 31,200 cfm; no changes to the duct design are made.

42 ENGINEERING↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3420 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3420 Building filtered exhaust stack system. The updated system will increase the number of fans from three to four and will include ductwork to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing three-fan stack was previously found to comply with the ANSI/HPS N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified four-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing three-fan system showed good agreement with test data collected from the 3420 Building stack. Modeling was performed to develop a suitable four-fan design. Initial modeling of the four-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design. The modeled final four-fan design, which meets the all the mixing criteria, included an air blender that is oversized relative to the main duct diameter to minimize the additional pressure drop created.

3420↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design.

42 ENGINEERING↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High capacity Li/Ni rich Ni-Ti-Mo oxide cathode for Li-ion batteries

With the rising cost and insufficient supply of cobalt, the thrust for cobalt-free cathode materials with the high specific capacity to build Li-ion batteries has increased significantly. Using nickel as the prime electrochemical active species, we have synthesized a new-class of materials with the combination of ordered and disordered phases. To obtain high capacity and electrical charge neutrality, stoichiometry of cations designed in a way that it forms Li/Ni rich Ni-Ti-Mo oxide materials. In addition to conventional capacity from redox activity of transition metals, partially reversible oxygen redox reaction also contributes to electrochemical activity and thus results in unusual high capacity. The resultant cathode materials of LiNi 0.5 Ti 0.5 O 2 -(Li 4 MoO 5 ) 0.8 and LiNiO 2 mixture phases reach the specific capacity of 240 mAh/g. Detailed soft X-ray absorption spectroscopy and electron microscopy are used to reveal the crystal phases in this system and trace changes in the Ni 2+ /Ni 4+ redox couple during charge-discharge processes. Finally, such comprehensive analysis of ordered-disordered oxides suggesting potentiality to develop high-capacity cobalt-free cathodes.

25 ENERGY STORAGE↗

Knowledge Transfer Program for International Nuclear Safeguards

Nuclear safeguards were first announced in 1945 by the U.S., Canadian and British governments as a means to exchange scientific information about peaceful uses of atomic energy and prevent the use of nuclear material for weapons. International nuclear safeguards, now under the provision of the International Atomic Energy Agency (IAEA), serves to hold accountable the 140 member countries (States) that have entered into treaties and agreements against the spread of nuclear weapons. Most notably, the IAEA acts as a nuclear materials inspectorate under the global Nuclear Non-Proliferation Treaty, brought about in 1968, that specifies commitments member States make to the world?s non-proliferation regime. The Office of International Nuclear Safeguards (OINS) is part of the National Nuclear Security Administration, a semi-autonomous agency within the U.S. Department of Energy. Within OINS, the Human Capital Development program recognizes the need to build workforce capacity and safeguards expertise. This includes supporting the education and training of younger generations working in international nuclear safeguards. One of the program?s main concerns is core competencies being lost to retirement or attrition and building knowledge retention pipelines from senior to new professionals. One identified core competency is knowledge gained by individuals who have completed IAEA assignments such as missions to member States to conduct safeguards inspections. Such individuals possess unique knowledge, and efforts are being put forth to effectively capture this knowledge within the national laboratories complex. To this end, we report findings from a one-year mentor-mentee knowledge retention program in which an international safeguards subject matter expert imparted knowledge and skills to a willing professional mentee. The knowledge and skills stem from the mentor?s multi-year assignment at the IAEA in Vienna, Austria.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Improving Power System Modeling. A Tool to Link Capacity Expansion and Production Cost Models

Capacity expansion models (CEM) provide a high-level long-term view at the prospects of the evolving power system. In simulating the possibilities of long-term capacity expansion, it is important to maintain the viability of power system operation in the short-term (daily, hourly and sub-hourly) scales. Production-cost models (PCM) simulate routine power system operation on these shorter time scales using detailed load, transmission and generation fleet data by minimizing production costs and following reliability requirements. When based on CEM 'predictions' about generating unit retirements and buildup, PCM provide more detailed simulation for the short-term system operation and, consequently, may confirm the validity of capacity expansion predictions. Further, production cost model simulations of a system that is based on capacity expansion model solution are 'evolutionary' sound: the generator mix is the result of logical sequence of unit retirement and buildup resulting from policy and incentives. The above has motivated us to bridge CEM with PCM by building a capacity expansion - to - production cost model Linking Tool (CEPCoLT). The Linking Tool is built to onset capacity expansion model prescriptions onto production cost model inputs. NREL's ReEDS and Energy Examplar's PLEXOS are the capacity expansion and the production cost models, respectively. Via the Linking Tool, PLEXOS provides details of operation for the regionally-defined ReEDS scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Very low temperature radiant heating/cooling indoor end system for efficient use of renewable energies

Solar or solar-assisted space heating systems are becoming more and more popular. The solar energy utilization efficiency is high when the collector is coupled with indoor radiant heating suppliers, since in principle, lower supply temperature means lower demand temperature and then the system heat loss is less. A new type radiant end system is put forward for even lower supply temperature compared to the conventional radiant floor heating systems. A three dimensional model was established to investigate its energy supply capacities. Simulation results show that 50 W per meter length tube can be achieved with the medium temperature of 30 C for heating and 15 C for cooling. The predicted results agree well with the actual data from a demonstration building. Furthermore, it is demonstrated that a supply temperature of 22 C in winter and of 17 C in summer already met the indoor requirements. The new end system has good prospects for effective use of local renewable resources. (author)

14 SOLAR ENERGY↗

Seismic Assessment of Buildings: Proposal of a New Modified Uncoupled Modal Response History Analysis

This paper develops a new modified uncoupled modal response history analysis (M-UMRHA) in order to study the seismic behavior of structures. It aims to provide an acceptable accuracy with reduced calculation duration in comparison to complete analysis, i.e. the THA. The proposed method improves the existing UMRHA, developed by Chopra and Goel [1], by considering an energy based approach to build the capacity curve [2] and a pseudo-adaptive feature to account for changes in modal shapes after yielding, motivated by an adaptive method [3]. Validation is made by comparison with NLTHA as well as other simplified methods. Low and medium-rise RC buildings were analyzed under real ground motion records. Results show good estimates of structural parameters and give good correlation between damage and story displacements as well as drifts. Like other simplified methods, accuracy decreases in the inelastic domain. However, this procedure gives acceptable estimates of structural response with a few additional calculations and it has the potential to be used in large scale studies, and probabilistic approaches.

42 ENGINEERING↗

Comparative Policy Study for Green Buildings in U.S. and China

Prominent barriers facing the U.S. green building industry include the fact that government bodies that supervise health, fire safety, land, and other public operations are slow to revise codes to accommodate green building (regulatory barrier). In China, the lack of a green building professional accreditation process similar to the Leadership in Energy and Environmental Design (LEED) AP process limits the green building workforce capacity development (informational barrier). The main policies highlighted in this report to tackle these barriers are 1) comprehensive codes and labeling plan (informational, institutional), 2) government-led targets and demonstrations (risk), 3) education and awareness programs (informational), 4) fiscal policy that supports green building investment (financial), and 5) integrated design promotion (institutional, financial).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Laboratory Test Report for Six ENERGY STAR Dehumidifiers

This report documents the measured performance of six residential ENERGY STAR vapor compression dehumidifiers. The performance of each was measured over a wide range of inlet air conditions and fit to a numerical model for capacity and efficiency. Performance curves were developed for use in EnergyPlus. Test data from all six dehumidifiers were also fit to generic performance curves. This work can be used by energy modelers and equipment manufacturers to understand how current products will operate in a wide range of environments, and to develop advanced space conditioning systems for efficient, safe, durable and healthy homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Net Metering Expansion on the Winnebago Tribe of Nebraska Reservation (Final Technical Report)

The Winnebago Tribe of Nebraska, through their affiliated economic development entity Ho-Chunk, Inc; their affiliated non-profit Ho-Chunk Community Development Corporation; and an additional project partner Nebraska Renewable Energy Systems conducted a community scale renewable energy project on their reservation in Nebraska. Over the two-year project period, we installed PV Solar systems on ten tribally owned commercial/retail/office facilities, which included both six roof mounted and four pole mount installations. The project was undertaken as a part of the Tribe’s broader initiative to increase renewable energy production on the reservation, reduce the Tribe’s financial obligations for purchasing energy, and lessen our reliance upon outside sources of energy to meet our basic needs. The project enabled us to formalize and strengthen community collaborations and build our capacity to pursue additional renewable energy opportunities that will enhance our energy sovereignty.

14 SOLAR ENERGY↗

IEA Wind TCP Task 26: Impacts of Wind Turbine Technology on the System Value of Wind in Europe

This report analyzes the impact of different land-based wind turbine designs on grid integration and related system value and cost. This topic has been studied in a number of previous publications, showing the potential benefits of wind turbine technologies that feature higher capacity factors. Building on the existing literature, this study aims to quantify the effects of different land-based wind turbine designs in the context of a projection of the European power system to 2030. This study contributes with insights on the quantitative effects in a likely European market setup, taking into account the effect of existing infrastructure on both existing conventional and renewable generation capacities. Furthermore, the market effects are put into perspective by comparing cost estimates for deploying different types of turbine design. Although the study focuses on Europe, similar considerations and results can be applied to other power systems with high wind penetration.

17 WIND ENERGY↗

Experimental investigation on performance of ice storage air-conditioning system with separate heat pipe

An experimental study on operation performance of ice storage air-conditioning system with separate helical heat pipe is conducted in this paper. The experimental system of ice storage air-conditioning system with separate heat pipe is set up. The performance parameters such as the evaporation pressure and the condensation pressure of refrigeration system, the refrigeration capacity and the COP (coefficient of performance) of the system, the IPF (ice packing factor) and the cool storage capacity in the cool storage tank during charging period, and the cool discharge rate and the cool discharge capacity in the cool storage tank, the outlet water temperature in the cool storage tank and the outlet air temperature in room unit during discharging period are investigated. The experimental results show that the ice storage air-conditioning system with separate helical heat pipe can stably work during charging and discharging period. This indicates that the ice storage air-conditioning system with separate helical heat pipe is well adapted to cool storage air-conditioning systems in building. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Health Security and Threat Reduction through Sharing Sequence Data

With the rapid development and broad applications of next-generation sequencing platforms and bioinformatic analytical tools, genomics has become a popular area for biosurveillance and international scientific collaboration. Governments from countries including the United States (US), Canada, Germany, and the United Kingdom have leveraged these advancements to support international cooperative programs that aim to reduce biological threats and build scientific capacity worldwide. A recent conference panel addressed the impacts of the enhancement of genomic sequencing capabilities through three major US bioengagement programs on international scientific engagement and biosecurity risk reduction. Here, the panel contrasted the risks and benefits of supporting the enhancement of genomic sequencing capabilities through international scientific engagement to achieve biological threat reduction and global health security. The lower costs and new bioinformatic tools available have led to the greater application of sequencing to biosurveillance. Strengthening sequencing capabilities globally for the diagnosis and detection of infectious diseases through mutual collaborations has a high return on investment for increasing global health security. International collaborations based on genomics and shared sequence data can build and leverage scientific networks and improve the timeliness and accuracy of disease surveillance reporting needed to identify and mitigate infectious disease outbreaks and comply with international norms. Further efforts to promote scientific transparency within international collaboration will improve trust, reduce threats, and promote global health security.

60 APPLIED LIFE SCIENCES↗

Transient analysis and energy optimization of solar heating and cooling systems in various configurations

In this paper, a transient simulation model of solar-assisted heating and cooling systems (SHC) is presented. A detailed case study is also discussed, in which three different configurations are considered. In all cases, the SHC system is based on the coupling of evacuated solar collectors with a single-stage LiBr-H{sub 2}O absorption chiller, and a gas-fired boiler is also included for auxiliary heating, only during the winter season. In the first configuration, the cooling capacity of the absorption chiller and the solar collector area are designed on the basis of the maximum cooling load, and an electric chiller is used as the auxiliary cooling system. The second layout is similar to the first one, but, in this case, the absorption chiller and the solar collector area are sized in order to balance only a fraction of the maximum cooling load. Finally, in the third configuration, there is no electric chiller, and the auxiliary gas-fired boiler is also used in summer to feed the absorption chiller, in case of scarce solar irradiation. The simulation model was developed using the TRNSYS software, and included the analysis of the dynamic behaviour of the building in which the SHC systems were supposed to be installed. The building was simulated using a single-lumped capacitance model. An economic model was also developed, in order to assess the operating and capital costs of the systems under analysis. Furthermore, a mixed heuristic-deterministic optimization algorithm was implemented, in order to determine the set of the synthesis/design variables that maximize the energy efficiency of each configuration under analysis. The results of the case study were analyzed on monthly and weekly basis, paying special attention to the energy and monetary flows of the standard and optimized configurations. The results are encouraging as for the potential of energy saving. On the contrary, the SHC systems appear still far from the economic profitability: however, this is notoriously true for the great majority of renewable energy systems. (author)

14 SOLAR ENERGY↗