Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CSI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Design of High Power Density 100 kW Surface Permanent Magnet Machine with No Heavy Rare Earth Material Using Current Source Inverter for Traction Application

Surface permanent magnet (SPM) machines are appealing candidates for traction applications because of high power density and high efficiency. Rare-earth magnets deliver high performance but raise concerns about material supply dependability, particularly if they use heavy rare-earth materials. This paper presents the design of a high-performance SPM machine without any heavy rare-earth material that is optimized specifically for a current-source inverter (CSI) traction drive. This machine is designed for a constant-power speed ratio (CPSR) of 3. A genetic algorithm has been performed to achieve a target of 50 kW/L active power density at speeds up to 20,000 rpm. Operation at a peak line-to-line voltage of 800 V can be achieved using 1200 V power devices with a safety margin. The predicted electromagnetic and rotor structural performance characteristics are presented using both analytical and finite element analysis (FEA) results.

(CPSR)↗

Building America Guidance for Identifying and Overcoming Code, Standard, and Rating Method Barriers

This guidance document was prepared using the input from the meeting summarized in the draft CSI Roadmap to provide Building America research teams and partners with specific information and approaches to identifying and overcoming potential barriers to Building America innovations arising in and/or stemming from codes, standards, and rating methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metal Halide Scintillators with Fast and Self‐Absorption‐Free Defect‐Bound Excitonic Radioluminescence for Dynamic X‐Ray Imaging

Abstract Scintillators for radiation detection are of great significance in medical imaging, security, and nondestructive inspection. The current challenge for scintillators is to simultaneously achieve high scintillation light yield, fast radioluminescence, simple film fabrication, large X‐ray attenuation efficiency as well as stable and nontoxic compositions; no previous scintillators fulfill all the above requirements. Here, metal halide Rb 2 AgBr 3 , possessing defect‐bound excitonic radioluminescence, is shown as efficient and fast scintillators. This nontoxic and stable scintillator emits from excitons bound to neutral bromine vacancies, enjoying an efficient and spin‐allowed fast emission with minimized self‐absorption. Rb 2 AgBr 3 thus has a high light yield (25 600 photons MeV −1 ), fast scintillation decay time (5.31 ns), and a record value of light yield versus decay time (4821 photons MeV −1 ns −1 ). The close‐space sublimation method is developed for fast and scalable fabrication of oriented Rb 2 AgBr 3 films. The scintillator film is further integrated with commercial flat‐panel imagers, and the spatial resolution reaches 10.2 line pairs per millimeter at the modulation transfer function of 0.2, doubling the resolution of conventional CsI:Tl flat‐panel detectors. The dynamic X‐ray imaging and its use to real‐time monitoring of bone movement without ghosting effect is also demonstrated.

Zhang, Muyi↗

In Situ Synchrotron-Based IR Microspectroscopy To Study Catalytic Reactions in Zeolite Crystals

CSI: Carbocation species identification: The nonhomogeneous distribution of the reaction products of styrene oligomerization on large ZSM-5 crystals was mapped with in situ IR microspectroscopy. Diffraction-limited spatial resolution was achieved with synchrotron light. IR spectra for possible reaction products were calculated with DFT/B3LYP; by comparison with experimental results carbocationic reaction species formed in zeolite channels could be singled out.

43 PARTICLE ACCELERATORS↗

Toward Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ): Initial fabrication and characterization

Purpose We present the first prototype Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ). This detector includes a layer of avalanche amorphous Selenium (a‐Se) ( HARP ) as the photoconductor in an indirect detector to amplify the signal and reduce the effects of electronic noise to obtain quantum noise‐limited images for low‐dose applications. It is the first time avalanche a‐Se has been used in a solid‐state imaging device and poses as a possible solution to eliminate the effects of electronic noise, which is crucial for low‐dose imaging performance of AMFPI . Methods We successfully deposited a solid‐state HARP structure onto a 24 × 30 cm 2 array of thin‐film transistors ( TFT array) with a pixel pitch of 85 μm. The HARP layer consists of 16 μm of a‐Se with a hole‐blocking and electron‐blocking layer to prevent charge injection from the high‐voltage bias and pixel electrodes, respectively. An electric field ( E S e ) up to 105 V μm −1 was applied across the a‐Se layer without breakdown. A 150 μm thick‐structured CsI:Tl scintillator was used to form SHARP ‐ AMFPI . The x‐ray imaging performance is characterized using a 30 kV p Mo/Mo beam. We evaluate the spatial resolution, noise power, and detective quantum efficiency at zero frequency of the system with and without avalanche gain. The results are analyzed using cascaded linear system model ( CLSM ). Results An avalanche gain of 76 ± 5 was measured at E S e = 105 V μm −1 . We demonstrate that avalanche gain can amplify the signal to overcome electronic noise. As avalanche gain is increased, image quality improves for a constant (0.76 mR ) exposure until electronic noise is overcome. Our system is currently limited by poor optical transparency of our high‐voltage electrode and long integrating time which results in dark current noise. These two effects cause high‐spatial frequency noise to dominate imaging performance. Conclusions We demonstrate the feasibility of a solid‐state HARP x‐ray imager and have fabricated the largest active area HARP sensor to date. Procedures to reduce secondary quantum and dark noise are outlined. Future work will improve optical coupling and charge transport which will allow for frequency DQE and temporal metrics to be obtained.

Scheuermann, James R.↗

Bragg-Primakoff axion photoconversion in crystal detectors

Abstract Axions and axion-like pseudoscalar particles with dimension-5 couplings to photons exhibit coherent Primakoff scattering with ordered crystals at keV energy scales, making for a natural detection technique in searches for solar axions. We find that there are large suppressive corrections, potentially greater than a factor of$$ \mathcal{O} $$ O (10 3 ), to the coherent enhancement when taking into account absorption of the final state photon. This effect has already been accounted for in light-shining-through-wall experiments through the language of Darwin classical diffraction, but is missing from the literature in the context of solar axion searches that use a matrix element approach. We extend the treatment of the event rate with a heuristic description of absorption effects to bridge the gap between these two languages. Furthermore, we explore the Borrmann effect of anomalous absorption in lifting some of the event rate suppression by increasing the coherence length of the conversion. We study this phenomenon in Ge, NaI, and CsI crystal experiments and its impact on the projected sensitivities of SuperCDMS, LEGEND, and SABRE to the solar axion parameter space. Lastly, we comment on the reach of multi-tonne scale crystal detectors and strategies to maximize the discovery potential of experimental efforts in this vein.

Physics↗

A statistical analysis of the COHERENT data and applications to new physics

The observation of coherent elastic neutrino nucleus scattering (CEvNS) by the COHERENT collaboration in 2017 has opened a new window to both test Standard Model predictions at relatively low energies and probe new physics scenarios. Our investigations show, however, that a careful treatment of the statistical methods used to analyze the data is essential to derive correct constraints and bounds on new physics parameters. In this manuscript we perform a detailed analysis of the publicly available COHERENT CsI data making use of all available background data. We point out that Wilks’ theorem is not fulfilled in general and a calculation of the confidence regions via Monte Carlo simulations following a Feldman-Cousins procedure is necessary. As an example for the necessity of this approach to test new physics scenarios we quantify the allowed ranges for several scenarios with neutrino non-standard interactions. Furthermore, we provide accompanying code to enable an easy implementation of other new physics scenarios as well as data files of our results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of Lung Contour with Closed Principal Curve and Machine Learning

Radiation therapy plays an essential role in the treatment of cancer. In radiation therapy, the ideal radiation doses are delivered to the observed tumor while not affecting neighboring normal tissues. In three-dimensional computed tomography (3D-CT) scans, the contours of tumors and organs-at-risk (OARs) are often manually delineated by radiologists. The task is complicated and time-consuming, and the manually delineated results will be variable from different radiologists. We propose a semi-supervised contour detection algorithm, which firstly uses a few points of region of interest (ROI) as an approximate initialization. Then the data sequences are achieved by the closed polygonal line (CPL) algorithm, where the data sequences consist of the ordered projection indexes and the corresponding initial points. Finally, the smooth lung contour can be obtained, when the data sequences are trained by the backpropagation neural network model (BNNM). We use the private clinical dataset and the public Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset to measure the accuracy of the presented method, respectively. To the private dataset, experimental results on the initial points which are as low as 15% of the manually delineated points show that the Dice coefficient reaches up to 0.95 and the global error is as low as 1.47 × 10{sup −2}. The performance of the proposed algorithm is also better than the cubic spline interpolation (CSI) algorithm. While on the public LIDC-IDRI dataset, our method achieves superior segmentation performance with average Dice of 0.83.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision Compton polarimetry for the QWeak experiment at Jefferson Lab

The Q Weak experiment, scheduled to run in 2010-2012 in Hall C at Jefferson Lab, will measure the parity-violating asymmetry in elastic electron-proton scattering at 1.1 GeV to determine the weak charge of the proton, Q{sub Weak}{sup p} = 1 - 4 sin{sup 2} {theta}{sub W}. The dominant experimental systematic uncertainty will be the knowledge of the electron beam polarization. With a new Compton polarimeter we aim to measure the beam polarization with a statistical precision of 1% in one hour and a systematic uncertainty of 1%. A low-gain Fabry-Perot cavity laser system provides the circularly polarized photons. The scattered electrons are detected in radiation-hard diamond strip detectors, and form the basis for a coincidence trigger using distributed logic boards. The photon detector uses a fast, undoped CsI crystal with simultaneous sampling and integrating read-out. Coincident events are used to cross-calibrate the photon and electron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a phoswich detector system for radioxenon monitoring

Abstract Measurement of radioactive xenon in the atmosphere is one of several techniques to detect nuclear weapons testing. For high sensitivity, some existing systems use beta/gamma coincidence detection to suppress background, which is very effective, but increases complexity due to separate beta and gamma detectors that require careful calibration and gain matching. In this paper, we will describe the development and evaluation of a simpler detector system, named PhosWatch, consisting of a CsI(Tl)/ BC-404 phoswich well detector, digital readout electronics, and pulse shape analysis algorithms implemented in a digital signal processor on the electronics, and compare its performance to existing multi-detector systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Compton-Vetoed Germanium Detector with Increased Sensitivity at Low Energies

The difficulty to directly detect plutonium in spent nuclear fuel due to the high Compton background of the fission products motivates the design of a Gamma detector with improved sensitivity at low energies. We have built such a detector by operating a thin high-purity Ge detector with a large scintillator Compton veto directly behind it. The Ge detector is thin to absorb just the low-energy Pu radiation of interest while minimizing Compton scattering of high energy radiation from the fission products. The subsequent scintillator is large so that forward scattered photons from the Ge detector interact in it at least once to provide an anti-coincidence veto for the Ge detector. For highest sensitivity, additional material in the line-of-sight is minimized, the radioactive sample is kept thin, and its radiation is collimated. We will discuss the instrument design, and demonstrate the feasibility of the approach with a prototype that employs two large CsI scintillator vetoes. Initial spectra of a thin Cs-137 calibration source show a background suppression of a factor of {approx}2.5 at {approx}100 keV, limited by an unexpectedly thick 4 mm dead layer in the Ge detector.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Emission from Crystals Irradiated with a Beam of Runaway Electrons

An investigation of the spectral and amplitude-temporal characteristics of emission from different crystals, promising in terms of their application as detectors of runaway electrons, is performed. This emission is excited by subnanosecond electron beams generated in a gas diode. It is found out that at the electron energies of tens–hundreds of kiloelectronvolts, the main contribution into the emission from CsI, ZnS, type IIa artificial and natural diamonds, sapphire, CaF{sub 2}, ZrO{sub 2}, Ga{sub 2}O{sub 3}, CaCO{sub 3}, CdS, and ZnSe crystals comes from the cathodoluminescence; the radiation pulse duration depends on the crystal used and sufficiently exceeds the Cherenkov radiation pulse duration. It is demonstrated that the latter radiation exhibits low intensity and can be detected in the short-wave region of the spectrum in the cases where a monochromator and a high-sensitivity photomultiplier tube (PMT) are used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Understanding the influence of boron in additively manufactured GammaPrint®-700 CoNi-based superalloy

Boron is commonly added to superalloys in small amounts to enhance creep resistance, but can lead to cracking at high concentrations, especially during the additive manufacturing process. Two variants of CoNi-based GammaPrint®-700 superalloy with different B contents (0.08 at% vs 0.16 at%) were printed via laser powder bed fusion (LPBF) with the same printing parameters, with only the high B alloy exhibiting solidification cracking. Atom probe tomography (APT) revealed stronger segregation behaviors in the high B alloy compared to the low B alloy at both the inter-dendritic regions and grain boundaries (GBs). The segregation behavior at inter-dendritic regions was well captured with Scheil simulation and can correlate with the existing cracking susceptibility index (CSI) on cracking tendencies, although high angle GBs are where cracking occurs according to electron backscatter diffraction (EBSD) measurements. Additionally, the extent of GB segregation was compared between the high B and low B alloy. Higher B additions led to significantly more GB B segregation in the high B alloy compared to the low B alloy. Further, for the high B alloy, the cracked region of one GB exhibited higher levels of B compared to the uncracked region of the same GB. However, much higher B contents were also found in two other uncracked GBs in the high B alloy, which demonstrates that higher GB B concentrations are not fully responsible for the cracking. A much larger variance in GB B segregation content was found in the high B alloy compared to the low B alloy. These phenomena were explained with a solidification model with the GB segregation content expressed explicitly by a modified Langmuir-McLean equation. This model linked the GB segregation content with solidification undercooling, which can be used as quantitative cracking criteria for future builds.

36 MATERIALS SCIENCE↗

Precise half-life determination of 131 Ba and 125 Xe

Barium-131 and Xenon-125 are valuable radioisotopes with numerous scientific and medical applications. Here, we produced both isotopes via proton irradiation of a cesium iodide (CsI) target at the Brookhaven Tandem Van de Graaff accelerator (BTVG). Following irradiation, we conducted systematic γ-ray spectroscopy measurements at the National Nuclear Data Center (NNDC) decay station using a calibrated High-Purity Germanium (HPGe) detector, collecting data over a 2-month period (spanning approximately 4.5 half-lives for 131 Ba). Through careful analysis of the characteristic γ-ray emissions from both isotopes, we determined the half-life of 131 Ba to be 11.55(6) days, which agrees with the previously evaluated value. For 125 Xe, we measured a half-life of 16.56(8) hours, slightly lower than the evaluated value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ameloblastin binding to biomimetic models of cell membranes – A continuum of intrinsic disorder

A 37-residue amino acid sequence corresponding to the segment encoded by exon-5 of murine ameloblastin (Ambn), AB2 (Y67-Q103), has been implicated with membrane association, ameloblastin self-assembly, and amelogenin-binding. Here, our aim was to characterize, at the residue level, the structural behavior of AB2 bound to chemical mimics of biological membranes using NMR spectroscopy. To better define the structure of AB2 using NMR-based methods, recombinant 13 C- and 15 N-labelled AB2 (*AB2) was prepared and data collected free in solution and with deuterated dodecylphosphocholine (dPC) micelles, deuterated bicelles, and both small and large unilamellar vesicles. Amide chemical shift and intensity perturbations observed in 1 H- 15 N HSQC spectra of *AB2 in the presence of bicelles and dPC micelles suggest that a region of *AB2, S6-E36 (murine Ambn S68 – E98), associates with the membrane biomimetics. A CSI-3 analysis of the NMR chemical shift assignments for *AB2 free in solution and bound to dPC micelles indicated the peptide remains disordered except for the adoption of a short, 12-residue α-helix, F10-G21 (murine Ambn F72-G83). In dPC micelles, the NOE NMR data was void of patterns characteristic of long-lived helical structure indicating this helix was transient in nature. A continuum of intrinsic disorder in the membrane-bound state may be responsible for ameloblastin’s ability to dynamically interact with multiple partners at the same site during amelogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Dose-Effect Relationships for Adverse Events After Cranial Radiation Therapy in Long-term Childhood Cancer Survivors

Purpose: To evaluate the prevalence and severity of clinical adverse events (AEs) and treatment-related risk factors in childhood cancer survivors treated with cranial radiation therapy (CRT), with the aim of assessing dose-effect relationships. Methods and Materials: The retrospective study cohort consisted of 1362 Dutch childhood cancer survivors, of whom 285 were treated with CRT delivered as brain irradiation (BI), as part of craniospinal irradiation (CSI), and as total body irradiation (TBI). Individual CRT doses were converted into the equivalent dose in 2-Gy fractions (EQD{sub 2}). Survivors had received their diagnoses between 1966 and 1996 and survived at least 5 years after diagnosis. A complete inventory of Common Terminology Criteria for Adverse Events grade 3.0 AEs was available from our hospital-based late-effect follow-up program. We used multivariable logistic and Cox regression analyses to examine the EQD{sub 2} in relation to the prevalence and severity of AEs, correcting for sex, age at diagnosis, follow-up time, and the treatment-related risk factors surgery and chemotherapy. Results: There was a high prevalence of AEs in the CRT group; over 80% of survivors had more than 1 AE, and almost half had at least 5 AEs, both representing significant increases in number of AEs compared with survivors not treated with CRT. Additionally, the proportion of severe, life-threatening, or disabling AEs was significantly higher in the CRT group. The most frequent AEs were alopecia and cognitive, endocrine, metabolic, and neurologic events. Using the EQD{sub 2}, we found significant dose-effect relationships for these and other AEs. Conclusion: Our results confirm that CRT increases the prevalence and severity of AEs in childhood cancer survivors. Furthermore, analyzing dose-effect relationships with the cumulative EQD{sub 2} instead of total physical dose connects the knowledge from radiation therapy and radiobiology with the clinical experience.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Failure After Proton Therapy in Medulloblastoma; Linear Energy Transfer Distributions and Relative Biological Effectiveness Associations for Relapses

Purpose: The pattern of failure in medulloblastoma patients treated with proton radiation therapy is unknown. For this increasingly used modality, it is important to ensure that outcomes are comparable to those in modern photon series. It has been suggested this pattern may differ from photons because of variations in linear energy transfer (LET) and relative biological effectiveness (RBE). In addition, the use of matching fields for delivery of craniospinal irradiation (CSI) may influence patterns of relapse. Here we report the patterns of failure after the use of protons, compare it to that in the available photon literature, and determine the LET and RBE values in areas of recurrence. Methods and Materials: Retrospective review of patients with medulloblastoma treated with proton radiation therapy at Massachusetts General Hospital (MGH) between 2002 and 2011. We documented the locations of first relapse. Discrete failures were contoured on the original planning computed tomography scan. Monte Carlo calculation methods were used to estimate the proton LET distribution. Models were used to estimate RBE values based on the LET distributions. Results: A total of 109 patients were followed for a median of 38.8 months (range, 1.4-119.2 months). Of the patients, 16 experienced relapse. Relapse involved the supratentorial compartment (n=8), spinal compartment (n=11), and posterior fossa (n=5). Eleven failures were isolated to a single compartment; 6 failures in the spine, 4 failures in the supratentorium, and 1 failure in the posterior fossa. The remaining patients had multiple sites of disease. One isolated spinal failure occurred at the spinal junction of 2 fields. None of the 70 patients treated with an involved-field-only boost failed in the posterior fossa outside of the tumor bed. We found no correlation between Monte Carlo-calculated LET distribution and regions of recurrence. Conclusions: The most common site of failure in patients treated with protons for medulloblastoma was outside of the posterior fossa. The most common site for isolated local failure was the spine. We recommend consideration of spinal imaging in follow-up and careful attention to dose distribution in the spinal junction regions. Development of techniques that do not require field matching may be of benefit. We did not identify a direct correlation between lower LET values and recurrence in medulloblastoma patients treated with proton therapy. Patterns of failure do not appear to differ from those in patients treated with photon therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗