Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONFIGURATION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Performance Prediction of Big Data Transfer Through Experimental Analysis and Machine Learning

Big data transfer in next-generation scientific applications is now commonly carried out over connections with guaranteed bandwidth provisioned in High-performance Networks (HPNs) through advance bandwidth reservation. To use HPN resources efficiently, provisioning agents need to carefully schedule data transfer requests and allocate appropriate bandwidths. Such reserved bandwidths, if not fully utilized by the requesting user, could be simply wasted or cause extra overhead and complexity in management due to exclusive access. This calls for the capability of performance prediction to reserve bandwidth resources that match actual needs. Towards this goal, we employ machine learning algorithms to predict big data transfer performance based on extensive performance measurements, which are collected over a span of several years from a large number of data transfer tests using different protocols and toolkits between various end sites on several real-life physical or emulated HPN testbeds. We first identify a comprehensive list of attributes involved in a typical big data transfer process, including end host system configurations, network connection properties, and control parameters of data transfer methods. We then conduct an in-depth exploratory analysis of their impacts on application-level throughput, which provides insights into big data transfer performance and motivates the use of machine learning. We also investigate the applicability of machine learning algorithms and derive their general performance bounds for performance prediction of big data transfer in HPNs. Experimental results show that, with appropriate data preprocessing, the proposed machine learning-based approach achieves 95% or higher prediction accuracy in up to 90% of the cases with very noisy real-life performance measurements.

Yun, Daqing↗

Performance Prediction of Big Data Transfer Through Experimental Analysis and Machine Learning

Big data transfer in next-generation scientific ap- plications is now commonly carried out over connections with guaranteed bandwidth provisioned in High-performance Net- works (HPNs) through advance bandwidth reservation. To use HPN resources efficiently, provisioning agents need to carefully schedule data transfer requests and allocate appropriate band- widths. Such reserved bandwidths, if not fully utilized by the requesting user, could be simply wasted or cause extra overhead and complexity in management due to exclusive access. This calls for the capability of performance prediction to reserve bandwidth resources that match actual needs. Towards this goal, we employ machine learning algorithms to predict big data transfer perfor- mance based on extensive performance measurements, which are collected over a span of several years from a large number of data transfer tests using different protocols and toolkits between various end sites on several real-life physical or emulated HPN testbeds. We first identify a comprehensive list of attributes involved in a typical big data transfer process, including end host system configurations, network connection properties, and control parameters of data transfer methods. We then conduct an in-depth exploratory analysis of their impacts on application- level throughput, which provides insights into big data transfer performance and motivates the use of machine learning. We also investigate the applicability of machine learning algorithms and derive their general performance bounds for performance prediction of big data transfer in HPNs. Experimental results show that, with appropriate data preprocessing, the proposed machine learning-based approach achieves 95% or higher pre- diction accuracy in up to 90% of the cases with very noisy real-life performance measurements.

Yun, Daqing↗

Radio frequency passband signal generation using photonics

Devices, methods and systems for generating wideband, high-fidelity arbitrary radio frequency (RF) passband signals are described. A voltage tunable optical filter for arbitrary RF passband signal generation includes a first input configured to receive a broadband optical pulse train, a second input configured to receive a first control voltage representative of an amplitude signal, an electrooptic modulator to receive the broadband optical pulse train and the first control voltage, to modulate the broadband optical pulse train in accordance with the amplitude signal, and to produce two complementary optical outputs that form two arms of an interferometer, an optical delay component to impart an optical path difference into one of the complementary outputs of the electrooptic modulator, and a combiner or a splitter to receive two complementary optical outputs of the electrooptic modulator after impartation of the optical path difference and to produce an output interference pattern of fringes.

Gowda, Apurva Shantharaj↗

Radio frequency passband signal generation using photonics

Devices, methods and systems for generating wideband, high-fidelity arbitrary radio frequency (RF) passband signals are described. A voltage tunable optical filter for arbitrary RF passband signal generation includes a first input configured to receive a broadband optical pulse train, a second input configured to receive a first control voltage representative of an amplitude signal, an electrooptic modulator to receive the broadband optical pulse train and the first control voltage, to modulate the broadband optical pulse train in accordance with the amplitude signal, and to produce two complementary optical outputs that form two arms of an interferometer, an optical delay component to impart an optical path difference into one of the complementary outputs of the electrooptic modulator, and a combiner or a splitter to receive two complementary optical outputs of the electrooptic modulator after impartation of the optical path difference and to produce an output interference pattern of fringes.

Gowda, Apurva Shantharaj↗

Adaptive Laboratory Evolution for Enhanced Performance of Cupriavidus necator on Formic Acid

The need to decarbonize our economy is becoming ever more pressing. CO2, can be electrochemically reduced to formic acid, a soluble C1 molecule that can be used to store carbon and energy. Cupriavidus necator H16, a soil bacterium, capable of consuming and growing on formic acid as its sole carbon source, is well positioned to upgrade CO2-derived formic acid into value added chemicals such as sustainable aviation fuel. To improve the performance of C. necator on formic acid adaptive laboratory evolution (ALE), a proven tool for improving microbial fitness, has been conducted using continuous pH-stat bioreactors. The system works on the basis that consumption of formic acid raises the pH and triggers the addition of more formic acid to maintain the pH at 6.7, such that formic acid is provided at the same rate as it is consumed. This system has been coupled with level control to achieve continuous fermentation where cells acquiring mutations that improve growth on formic acid become more abundant in the population, from which they can be isolate and characterized. This configuration where the dilution rate is controlled by pH-stat has been found to seek out a dilution rate that matches the exponential growth rate of the organism. During developmental experiments it was discovered that formic acid accumulated to inhibitory levels. It was determined that the nitrogen source, ammonium hydroxide, must be tailored to the carbon consumption to avoid formic acid accumulation. ALE has run in three lineages for 2000+ hours and 300+ generations. Growth of evolved isolates derived from all lineages will be evaluated on formic acid and those with improved growth rates or biomass yield will be subjected to whole genome sequencing to identify potentially causative mutations. These mutations will be evaluated individually and in combination to identify those that improve growth on formic acid.

adaptive laboratory evolution↗

Apparatuses and methods for optical code-delay reflectometry (OcoDR)

Apparatuses and methods for optical code-delay reflectometry (OCoDR) are disclosed. An apparatus includes a modulator, a receiver, and control circuitry. The modulator is configured to receive incident electromagnetic (EM) radiation at a substantially fixed frequency generated by one or more EM radiation sources. The incident EM radiation includes continuous-wave EM radiation. The modulator is configured to impart a sequence onto an amplitude, a phase, or both of the incident EM radiation to generate modulated EM radiation. The modulated EM radiation includes continuous-wave EM radiation. The receiver is configured to receive reference EM radiation. The receiver is also configured to receive reflected EM radiation from an optical system responsive to the modulated EM radiation and generate interfered EM radiation responsive to the reference EM radiation and the reflected EM radiation. The receiver is further configured to generate a continuous interferogram responsive to the interfered EM radiation.

Seeley, Ryan↗

Development of a Multi-Robot System for Autonomous Inspection of Nuclear Waste Tank Pits

This paper introduces the overall design plan, development timeline, and preliminary progress of the Autonomous Pit Exploration System project. This project aims to develop an advanced multi-robot system for the efficient inspection of nuclear waste-storage tank pits. The project is structured into three phases: Phase 1 involves data collection and interface definition in collaboration with Hanford Site experts and university partners, focusing on tank riser geometry and hardware solutions. Phase 2 includes the selection of sensors and robot components, detailed mechanical design, and prototyping. Phase 3 integrates all components into a cohesive system managed by a master control package which also incorporates digital twin and surrogate models, and culminates in comprehensive testing and validation at a simulated tank pit at the Idaho National Laboratory. Additionally, the system’s communication design ensures coordinated operation through shared data, power, and control signals. For transportation and deployment, an electric vehicle (EV) is chosen to support the system for a full 10 h shift with better regulatory compliance for field deployment. A telescopic arm design is selected for its simple configuration and superior reach capability and controllability. Preliminary testing utilizes an educational robot to demonstrate the feasibility of splitting computational tasks between edge and cloud computers. Successful simultaneous localization and mapping (SLAM) tasks validate our distributed computing approach. More design considerations are also discussed, including radiation hardness assurance, SLAM performance, software transferability, and digital twinning strategies.

Nuclear waste management↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Learning Local Volt/VAR Controllers Toward Efficient Network Operation with Stability Guarantees: Preprint

This paper considers the problem of voltage regulation in distribution network. The primary motivation is to keep voltages within pre-assigned operating limits by commanding the reactive power output of distributed energy resources (DERs) deployed in the grid. We develop a framework for developing local Volt/Var control that comprises of two main steps. In the first, exploiting historical data and for each DER, we learn a function representing desirable equilibrium points for the power network. These points approximate solutions of an Optimal Power Flow problem. In the second, we propose a control scheme for steering the network towards these favorable configurations. Theoretical conditions are derived to formally guarantee the stability of the developed control scheme and numerical simulations illustrate the effectiveness of the proposed approach.

data-driven control↗

Real-time plasma equilibrium reconstruction and shape control for the MAST Upgrade tokamak

Real-time magnetic control has been developed to deliver precise control of multiple plasma shape parameters for advanced divertor configurations, including double-null, Super-X, X-point target and X-divertor for the first time on the MAST Upgrade (MAST-U) spherical tokamak. Successful real-time magnetic equilibrium control of different plasma shape variables has been accomplished in the 2022–2023 MAST-U experimental campaign for the advanced MAST-U divertor configurations. Application of the MAST-U boundary reconstruction algorithm, LEMUR, is described and compared with off-line equilibrium reconstruction and diagnostic measurements. The process of design and verification of the axisymmetric magnetic control schemes using a suite of control analysis tools (known collectively as TokSys) is also described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Actively controlled coolant tank to increase thermal storage capacity of hybrid electric vehicles

An engine and cabin thermal management system for use with a vehicle having an engine, a cabin heating system configured to thermally heat a cabin of the vehicle, a coolant system operably coupled to the engine and to the cabin heating system to thermally manage a temperature of the engine and a temperature of the cabin. The coolant system having one or more coolant thermal storage units fluidly coupled with a radiator and heater core of the coolant system forming a coolant loop. The system further having a control system configured to monitor and maintain at least a predetermined coolant temperature at the cabin heating system even during a coolant temperature decrease at the engine stops.

Amini, Mohammad Reza↗

Power supply circuit with multiple stages for converting high voltage to low voltage and power train having the same

A power supply circuit for converting a first voltage to a second voltage where the first voltage is greater than the second voltage, and a power train having the same, are provided. The power supply circuit may have multiple stages and each stage of the power supply circuit may include a first circuit block configured to provide a start-up power to a second circuit block; a second circuit block configured to generate a Pulse-Width-Modulation (PWM) signal that controls a pulse duration of a transistor; a third circuit block configured to activate or deactivate the transistor based on the PWM signal; a fourth circuit block configured to reset a magnetic flux in a transformer to a zero state when the transistor is deactivated; and a fifth circuit block configured to maintain an output of a stage below a predetermined value by adjusting a voltage across the transformer.

Singh, Brij N.↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗

Development of Control System Functional Capabilities within the IES Plug-and-Play Simulation Environment

The concept of an Integrated Energy System (IES) is meant to combine different energy technologies in synergistic ways to achieve a more secure and economical energy supply. The RAVEN-based HYBRID framework is used to find the optimal installed capacity and the optimal economical dispatch of each component of the IES. A new RAVEN (Risk Analysis Virtual ENvironment) plugin for grid and capacity optimization (HERON) has been developed for optimizing the production variables of the IES given the demand profile. Currently, only the limits that affect the production variables and their corresponding time rates of change are considered (explicit constraints). However, other variables are additionally subject to constraints, but the associated limits are not accounted for (implicit constraints). In particular, for the power dispatch problem, the optimization algorithm takes into account the limits on the electrical power output and the corresponding hourly power variations but does not consider other constraints on process variables whose response effects the service life of the IES. This report describes a scheme that allows accounting for implicit constraints without increasing the size of the optimization problem. The Reference Governor (RG) algorithm is traditionally used for enforcing state and control constraints by modifying the set-point trajectories supplied to the feedback regulators. In our application, the RG is coupled within an iterative loop with the HERON-power dispatcher to generate optimal trajectories that ensure the operational constraints are met. A data-driven procedure to derive a representation of the dynamics of the controlled system was developed. First, the variables that represented the state of the system are selected (PCA-based approach), and then state-space representation matrices are derived from the collected measurements (DMDc algorithm). A preliminary version of the developed workflow based on Linear Time Invariant matrices was assessed by adopting a two-unit test case. More sophisticated versions of this workflow foreseeing the on-line derivation of system matrices will be deployed in FY 2021. Finally, a “plug-and-play” library of controllers and state observers was developed in Dymola. Some aspects of the current configuration of the IES unit components, e.g., the encapsulation of the control schemes into dedicated blocks, are consistent with the “plug-and-play” philosophy. Other features, e.g., the system buses collecting the input and the output variables, are not. For this reason, once listed and described the limits of the current configuration, necessary modifications to the plant model interface are presented. As a test-case, the interfaces of the SES model in the RAVEN-based HYBRID framework were reworked accordingly, and two different control schemes were applied to the same plant model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart-DS: Synthetic Models for Advanced, Realistic Testing: Distribution Systems and Scenarios

The explosion of new ideas for distributed energy resources and advanced distribution grid algorithms faces a critical challenge: how can one effectively develop and evaluate these breakthrough technologies without an adequate set of power systems network, load, and resource data to test against? Today's open test systems, particularly for distribution systems, are tiny and incomplete; and though with enough effort, obtaining utility data under NDA can overcome scale challenges, the results can't be openly shared, preventing fair comparison. The Smart-DS project-led by NREL in partnership with MIT, Universidad Pontificia Comillas, CYME, and EDD-is working to overcome this gap by generating multiple large-scale, open, synthetic, distribution systems that are realistic but not real. These datasets go beyond a single medium voltage feeder (~1000 customers) to cover entire metropolitan areas and their surrounds with up to hundreds of feeders and millions of customers, complete with low voltage customer connections and high voltage sub-transmission. This scale allows adequate testing and analysis of not just local controls and advanced DERs, but also multiple substation interactions, optimized switching, full-scale distribution-OPF, and more. To accompany these datasets, the project is also building a rich set of scenario generation tools that can be used for distribution and transmission systems alike. This includes automated, spatially aware access to world-class, high-resolution solar, wind, and weather data: forward looking generation mixes: and highly configurable DER, load, climate, outage, control-scheme, and other scenarios. We will also highlight DiTTo, an exciting open-source, multi-way distribution dataset transformation tool for many-to-many format translation with scenario, merge/split, and many other manipulation capabilities.

DERs↗

Permanent magnets for ELM suppression in tokamaks: feasibility and operational compatibility

Permanent magnets can provide static magnetic fields without power supplies or feed lines, offering a simpler alternative to conventional electromagnets in tokamaks. This work examines permanent magnet arrays (PMAs) for edge localized mode (ELM) control in double-null (DN) configurations, where traditional RMP coils exhibit limited effectiveness. Linear plasma response calculations using IPEC assess high-field-side (HFS) permanent magnet placement, benchmarking performance against DIII-D low-field-side (LFS) internal coils (I-coils) while evaluating engineering constraints. Modeling results demonstrate that HFS permanent magnet configurations generate HFS plasma response amplitudes more than 5 times larger than conventional I-coil systems. While other resonant response metrics show comparable or reduced response relative to I-coils, the combination of conventional RMP systems and permanent magnets is expected to provide enhanced performance. Operational impact assessments of persistent magnetic fields, including sideband field effects and startup/ramp-up compatibility, reveal acceptable performance within established operational boundaries. This analysis establishes PMAs as a technically viable approach for DN ELM control with reductions in system complexity, motivating further experimental validation on existing tokamak facilities.

3D magnetic perturbation↗

Utah FORGE: Fault Shear Reactivation Experimental Data for Fluid Injection-Rate Controls on Seismic Moment

Included are experimental data recorded from shear experiments that specifically explore the link between fluid-injection rate and seismic moment resulting from shear reactivation of laboratory faults. Raw mechanical data from three experiments are included alongside corresponding MATLAB scripts that import and plot the data, as well as use it to calculate shear and normal stress. Experiments are performed on 2.5-3 inch long granitoid cores from the Utah FORGE EGS demonstration site, containing a single inclined fracture with small-scale roughness added to the fracture surface. The raw data included here were recorded from an aluminum triaxial pressure vessel (TEMCO) configured with three independent servo-controlled pumps, with distilled water used as the working fluid. The pumps control confining pressure, upstream pore pressure, and axial pressure, with each pump connected to a LabView interface to record applied pressures, cumulative injected water volumes, and pump flow rates. The downstream outlet from the fracture is closed to allow pressurization, which is measured by an external pressure transducer. A linear variable differential transformer (LVDT) attached to the axial piston measures axial displacement, from which we calculate shear displacement along the fracture. Additionally, P-wave transducers are used to record acoustic signatures, where acoustic emission events and maximum amplitudes are compared against seismic moment and shear slip velocity. Fluid injection rates range between 0.05 mL/min, 0.25 mL/min, and 0.75 mL/min for each experiment. Along-fault pressure distributions are progressively less uniform as injection rates increase, representing a switch from steady-state to transient conditions. Triggered shear displacement is used as a proxy for seismic moment and is indexed against cumulative injection volume and rate. Each experiment is performed under constant shear stress conditions, and the sample is fully saturated with DI water. Axial and confining stresses are applied to 3 MPa through pressure-stepping in 500 kPa increments. The pore pressure is held constant at 200 kPa prior to initiating the experiment, and initial axial displacement is recorded. The axial stress is then increased to initiate shear mobilization during the loading phase (run-in) until a peak steady state is achieved. The initial shear stress is reduced to approximately 80% of the peak shear stress by decreasing the axial stress, then held constant for the duration of each experiment.

15 GEOTHERMAL ENERGY↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗