Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CLOSURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Fabrication and Testing of DOE Standard Canister Closure Leak Test Assembly

DOE manages over 300 types of spent nuclear fuel (SNF), many of which are located at the Idaho National Laboratory (INL) site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in onsite storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale road-ready dry storage program at the INL site. In support of establishing a large-scale road-ready dry storage program at the INL site, the Road-Ready Demonstration will first package Fort St. Vrain SNF currently in dry storage at INL into several DOE Standard Canisters (DOESCs). These DOESCs will in turn be loaded into another containment similar to commercial multi-purpose canisters. This multi-purpose canister will then be compatible with a transportation or storage system, such as a storage cask for interim storage or transportation package for offsite transport. These DOESCs will remain sealed over the course of their storage, transportation, and applicable disposal functions. The closure process for the DOESC will include fuel and basket loading, welding, inspection, leak testing, and, if needed, repair. As a follow-up to previous discussions on the design of the DOE Closure Leak Test Assembly (LTA), this report describes recent fabrication and testing efforts performed at INL. DOESCs are sealed by two sequential gas tungsten arc welds, both of which are performed by remotely operated and semiautomatic welding systems. The first weld is a circumferential pipe weld that completes the assembly of the canister body and lid assembly. The second and final closure weld attaches the vent plug to the vent socket via a butt joint. After the second weld is performed, the welds are helium leak tested using an evacuated envelope technique. The LTA was designed for both remote and manual operation. This report describes the fabrication and performance testing associated with the evacuated envelope technique. INL staff designed, fabricated, and tested the LTA at INL facilities. This testing included establishing technique and system sensitivities in accordance with ASME and American National Standards Institute N14.5 requirements. Forthcoming work will cover such areas as design optimization, process and personnel qualification, and implementation in Road-Ready Demonstration operations.

42 ENGINEERING↗

Fabrication and Testing of DOE Standard Canister Closure Leak Test Assembly – 24139

DOE manages over 300 types of spent nuclear fuel (SNF), many of which are located at the Idaho National Laboratory (INL) site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in onsite storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale road-ready dry storage program at the INL site. In support of establishing a large-scale road-ready dry storage program at the INL site, the Road-Ready Demonstration will first package Fort St. Vrain SNF currently in dry storage at INL into several DOE Standard Canisters (DOESCs). These DOESCs will in turn be loaded into another containment similar to commercial multi-purpose canisters. This multi-purpose canister will then be compatible with a transportation or storage system, such as a storage cask for interim storage or transportation package for offsite transport. These DOESCs will remain sealed over the course of their storage, transportation, and applicable disposal functions. The closure process for the DOESC will include fuel and basket loading, welding, inspection, leak testing, and, if needed, repair. As a follow-up to previous discussions on the design of the DOE Closure Leak Test Assembly (LTA), this report describes recent fabrication and testing efforts performed at INL. DOESCs are sealed by two sequential gas tungsten arc welds, both of which are performed by remotely operated and semiautomatic welding systems. The first weld is a circumferential pipe weld that completes the assembly of the canister body and lid assembly. The second and final closure weld attaches the vent plug to the vent socket via a butt joint. After the second weld is performed, the welds are helium leak tested using an evacuated envelope technique. The LTA was designed for both remote and manual operation. This report describes the fabrication and performance testing associated with the evacuated envelope technique. INL staff designed, fabricated, and tested the LTA at INL facilities. This testing included establishing technique and system sensitivities in accordance with ASME and American National Standards Institute N14.5 requirements. Forthcoming work will cover such areas as design optimization, process and personnel qualification, and implementation in Road-Ready Demonstration operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE NEED FOR A NEW JOINING TECHNOLOGY FOR THE CLOSURE WELDING OF RADIOACTIVE MATERIALS CONTAINERS

One of the activities associated with cleanup throughout the Department of Energy (DOE) complex is packaging radioactive materials into storage containers. Much of this work will be performed in high-radiation environments requiring fully remote operations, for which existing, proven systems do not currently exist. These conditions demand a process that is capable of producing acceptable (defect-free) welds on a consistent basis; the need to perform weld repair, under fully-remote operations, can be extremely costly and time consuming. Current closure welding technology (fusion welding) is not well suited for this application and will present risk to cleanup cost and schedule. To address this risk, Fluor and the Pacific Northwest National Laboratory (PNNL), are proposing that a new and emerging joining technology, Friction Stir Welding (FSW), be considered for this work. FSW technology has been demonstrated in other industries (aerospace and marine) to produce near flaw-free welds on a consistent basis. FSW is judged capable of providing the needed performance for fully-remote closure welding of containers for radioactive materials for the following reasons: FSW is a solid-state process; material is not melted. As such, FSW does not produce the type of defects associated with fusion welding, e.g., solidification-induced porosity, cracking, distortion due to weld shrinkage, and residual stress. In addition, because FSW is a low-heat input process, material properties (mechanical, corrosion and environmental) are preserved and not degraded as can occur with 'high-heat' fusion welding processes. When compared to fusion processes, FSW produces extremely high weld quality. FSW is performed using machine-tool technology. The equipment is simple and robust and well-suited for high radiation, fully-remote operations compared to the relatively complex equipment associated with the fusion-welding processes. Additionally, for standard wall thicknesses of radioactive materials containers, the FSW process can perform final closure welding in a single pass (GTAW requires multiple passes) resulting in increased productivity. Together, the performance characteristics associated with FSW, i.e., high weld quality, simple machine-tool equipment and increased welding efficiency, are expected to reduce risk to upcoming DOE radioactive materials packaging campaigns. FSW technology requires some development/adaptation for this application, along with approval from the governing code of construction prior to production operations. This paper addresses the need for a new joining technology, a description of the FSW process and why it is well-suited for this application, and several activities required for commercialization.

42 ENGINEERING↗

Constrained optimization framework for interface-aware sub-scale dynamics models for voids closure in Lagrangian hydrodynamics

In hydrocodes, voids are used to represent vacuum and model free boundaries between vacuum and real materials. We give a systematic description of a new treatment of void closure in the framework of the multimaterial arbitrary Lagrangian–Eulerian (ALE) methods. This includes a new formulation of the interface-aware sub-scale-dynamics (IA-SSD) closure model for multimaterial cells with voids, which is used in the Lagrangian stage of our indirect ALE scheme. The results of the comprehensive testing of the new model are presented for one- and two-dimensional multimaterial calculations in the presence of voids. Finally, we also present a sneak peek of a realistic shaped charge calculation in the presence of voids and solids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Closure Report for Corrective Action Unit 563: Septic Systems, Nevada Test Site, Nevada

Corrective Action Unit (CAU) 563 is identified in the Federal Facility Agreement and Consent Order (FFACO) as “Septic Systems” and consists of the following four Corrective Action Sites (CASs), located in Areas 3 and 12 of the Nevada Test Site: · CAS 03-04-02, Area 3 Subdock Septic Tank · CAS 03-59-05, Area 3 Subdock Cesspool · CAS 12-59-01, Drilling/Welding Shop Septic Tanks · CAS 12-60-01, Drilling/Welding Shop Outfalls Closure activities were conducted from September to November 2009 in accordance with the FFACO (1996, as amended February 2008) and the Corrective Action Plan for CAU 563. The corrective action alternatives included No Further Action and Clean Closure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modelling the effect of divertor closure on detachment onset in DIII-D with the SOLPS code

SOLPS modelling has shown that divertor plasma detachment occurs at a lower upstream separatrix density in the more closed DIII-D upper divertor than the open lower divertor, demonstrating the utility of the divertor closure in widening the range of acceptable densities for adequate heat handling. To achieve reduced heat flux and erosion at the plasma-facing components, future devices will need to operate in at least partially detached divertor conditions . Two-dimensional fluid plasma models coupled to Monte Carlo neutral transport simulations, such as SOLPS, have been widely used to predict the onset of detachment. In modelling the DIII-D discharges, the cross-field transport coefficients are constrained to reproduce the experimental upstream profiles. The closed divertor has been modelled with the same input parameters of the open divertor, allowing a direct comparison of the target conditions in both geometries. SOLPS simulations indicate that a higher molecular density correlates strongly with lower electron temperatures. The increased closure of the upper divertor improves the trapping of neutrals, thereby reducing the power density deposited at the target and facilitating detachment, in agreement with experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Closure of Bronchopleural Fistula with Angio-Seal

Bronchopleural fistula is rare and occurs most often after trauma or surgery. Conservative management and support comprise the initial treatment, but if unsuccessful, surgical closure is usually required. We describe for what is to our knowledge the first successful use of an Angio-Seal vascular closure device in a patient who was not a candidate for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy and Safety of a Novel Vascular Closure Device (Glubran 2 Seal) After Diagnostic and Interventional Angiography in Patients with Peripheral Arterial Occlusive Disease

To prospectively evaluate safety and efficacy of a novel vascular closure device (Glubran 2 Seal) after peripheral angiography in patients with peripheral arterial occlusive disease (PAOD). From December 2010 to June 2011, all consecutive patients with PAOD undergoing peripheral angiography were prospectively enrolled onto the study after percutaneous antegrade or retrograde puncture of the common femoral artery. After angiography, the Glubran 2 Seal device was used to achieve hemostasis. The following data were registered: technical success and manual compression duration, patients' discomfort (scale 0-5), operators' technical difficulty (scale 0-5), and vascular complications. The site of hemostasis was evaluated by clinical inspection and color-coded Duplex ultrasound performed 1 day and 1 month after the procedure. One hundred seventy-eight patients were enrolled (112 male, mean age 70.8 years) with a total of 206 puncture sites, including 104 (50.5 %) antegrade accesses. The device was successful in 198(96.1 %) of 206 procedures, with 8 cases of manual compression lasting longer than 5 min (maximum 20 min). No major vascular complications were observed, resulting in 100 % procedural success. Minor complications occurred in seven procedures (3.4 %), including two cases of pseudoaneurysms, successfully treated by ultrasound-guided glue injection. The mean {+-} standard deviation score for patients' discomfort was 0.9 {+-} 0.7, whereas the mean score for operators' difficulty was 1.2 {+-} 0.9. In patients with PAOD, the Glubran 2 Seal represents a simple, painless, and efficient vascular closure device, able to achieve hemostasis both in antegrade and retrograde accesses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility and Safety of Vascular Closure Devices in an Antegrade Approach to Either the Common Femoral Artery or the Superficial Femoral Artery

Introduction: The purpose of the present study was to analyze complications following antegrade puncture of the common femoral artery (CFA) and the superficial femoral artery (SFA) using vascular closure systems (VCS). Methods: A single-center, retrospective study was performed after obtaining approval from the institutional review board and informed consent from all patients. At our center, the CFA or SFA are used for arterial access. All patients were evaluated clinically on the same day. If there was any suspicion of an access site problem, Duplex ultrasound was performed. Results: Access location was the CFA in 50 patients and the SFA in 130 patients. The sheath size ranged from 4F to 10F. Two patients had to be excluded because of lack of follow-up. Successful hemostasis was achieved in 162 of 178 cases (91 %). The following complications were observed in 16 patients (8.9 %): 4 pseudoaneurysms (2.2 %), 11 hematomas (6.2 %), and 1 vascular occlusion (0.5 %). The two pseudoaneurysms healed spontaneously, in one case an ultrasound-guided thrombin injection was performed, and one aneurysm was compressed manually. No further medical therapy was needed for the hematomas. The one vascular occlusion was treated immediately with angioplasty using a contralateral approach. No significant difference was noted between the CFA and the SFA group with respect to complications (p = 1.000). Conclusions: The use of closure devices for an antegrade approach up to 10F is feasible and safe. No differences in low complication rates were observed between CFA and SFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An efficient algorithm for generating diverse microstructure sets and delineating properties closures

Properties closures delineate the theoretical objective space for materials design problems, allowing designers to make informed trade-offs between competing constraints and target properties. In this paper, we present a new algorithm called hierarchical simplex sampling (HSS) that approximates properties closures more efficiently and faithfully than traditional optimization based approaches. By construction, HSS generates samples of microstructure statistics that span the corresponding microstructure hull. As a result, we also find that HSS can be coupled with synthetic polycrystal generation software to generate diverse sets of microstructures for subsequent mesoscale simulations. Finally, by more broadly sampling the space of possible microstructures, it is anticipated that such diverse microstructure sets will expand our understanding of the influence of microstructure on macroscale effective properties and inform the construction of higher-fidelity mesoscale structure-property models.

36 MATERIALS SCIENCE↗

On the surface energy balance closure at different temporal scales

Measurements of the surface energy fluxes (turbulent and radiative) and other ancillary atmospheric/soil parameters made in the Columbia River Basin (Oregon) in an area of complex terrain during a 10-month long portion of the second Wind Forecast Improvement Project (WFIP 2) field campaign are used to study the surface energy budget (SEB) and surface fluxes over different temporal scales. This study analyzes and discusses SEB closure based on half-hourly, daily, monthly, seasonal, and sub-annual (~10-month) temporal averages. The data were collected over all four seasons for different states of the underlying ground surface (dry, wet, and frozen). Our half-hourly direct measurements of energy balance show that the sum of the turbulent sensible and latent heat fluxes systematically underestimate positive net radiation by around 20–30% during daytime and overestimate negative net radiation at night. This imbalance of the surface energy budget is comparable to other terrestrial sites. However, on average, the residual energy imbalance is significantly reduced at daily, weekly, and monthly averaging timescales, and moreover, the SEB can be closed for this site within reasonable limits on seasonal and sub-annual timescales (311-day averaging for the entire field campaign dataset). Increasing the averaging time to daily and longer time intervals substantially reduces the ground heat flux and storage terms, because energy locally entering the soil, air column, and vegetation in the morning is released in the afternoon and evening. Averaging on daily to sub-annual timescales also reduces random instrumental measurement errors and other uncertainties as well as smooths out a hysteresis effect (phase lag) in the SEB relationship between different components. This study shows that SEB closure is better for dry soils compared to wet soils and the statistical dependence of the turbulent fluxes and net radiation for freezing soil surfaces appears weak, if not non-existent, apparently due to lack of the latent heat of fusion term in the traditional SEB equation.

54 ENVIRONMENTAL SCIENCES↗

Single-Channel Current Through Nicotinic Receptor Produced by Closure of Binding Site C-Loop

We investigated the initial coupling of agonist binding to channel gating of the nicotinic acetylcholine receptor using targeted molecular-dynamics (TMD) simulation. After TMD simulation to accelerate closure of the C-loops at the agonist binding sites, the region of the pore that passes through the cell membrane expands. To determine whether the structural changes in the pore result in ion conduction, we used a coarse-grained ion conduction simulator, Biology Boltzmann transport Monte Carlo, and applied it to two structural frames taken before and after TMD simulation. The structural model before TMD simulation represents the channel in the proposed resting state, whereas the model after TMD simulation represents the channel in the proposed active state. Under external voltage biases, the channel in the active state was permeable to cations. Our simulated ion conductance approaches that obtained experimentally and recapitulates several functional properties characteristic of the nicotinic acetylcholine receptor. Thus, closure of the C-loop triggers a structural change in the channel sufficient to account for the open channel current. This approach of applying Biology Boltzmann transport Monte Carlo simulation can be used to further investigate the binding to gating transduction mechanism and the structural bases for ion selection and translocation.

60 APPLIED LIFE SCIENCES↗

A closure model for predicting crack growth under creep-fatigue loading

A strip-yield model was formulated here to simulate creep-fatigue crack growth and to quantify the influence of hold time on plasticity-induced crack closure during creep-fatigue crack growth. Creep-fatigue experiments have shown that longer creep hold times result in faster crack growth rates in subsequent fatigue cycles. This model advances the idea that a decrease of plasticity-induced crack closure is experienced by the crack during fatigue loading when a longer hold time is applied each creep-fatigue cycle. Consequently, the crack tip experiences an increase in the effective stress intensity factor range causing faster growth rate during the fatigue loading. The weight function method was used to compute stress intensity factors and surface displacements for cracks embedded in a material experiencing elastic, plastic and creep deformations at elevated temperatures. It is shown that the longer the hold time, the larger the creep deformation and crack opening displacements in the near crack-tip region. In turn, this leads to a decrease in the crack-tip opening stress/load and faster crack growth rates during the subsequent fatigue cycle. The model was used to perform simulations of creep-fatigue crack growth at elevated temperatures in a nickel-base superalloy and AISI 316 austenitic steel.

42 ENGINEERING↗

The influence of plasticity-induced crack closure on creep-fatigue crack growth in two heat-resistant steels

Finite element simulations are performed to predict plasticity-induced crack closure and creep-fatigue crack growth rates in two heat-resistant steels, the austenitic 20Cr-25Ni (Alloy 709) and martensitic 9Cr-1Mo (modified 1Cr-9Mo) steels. In a creep-fatigue cycle, total crack growth rate is usually computed by the addition of the fatigue crack growth rate during cyclic loading and creep crack growth rate during hold time. Two-dimensional finite element analyses of compact tension specimens are performed to simulate crack growth under cyclic and time-dependent loading conditions, with the consideration of elastic-plastic and creep deformations of the material at the crack tip. The simulations quantify the effect of hold time on crack opening load induced by the combined action of plasticity-induced crack closure and creep-induced stress relaxation at the crack tip. It is shown that increasing hold time during a creep-fatigue cycle results in a decrease of crack-tip opening load, thus increasing crack growth rate during the next cyclic loading. Experimental results of creep-fatigue crack growth rates in Alloy 709 are presented. The finite element simulations predicted crack growth rates under creep-fatigue loading in agreement with experimental values for both Alloy 709 and modified 9Cr-1Mo steels.

36 MATERIALS SCIENCE↗

High strain-rate strength response of single crystal tantalum through in-situ hole closure imaging experiments

The properties of crystalline materials often depend on directionality and operating conditions. Specifically, the strength of materials can depend anisotropically on crystal direction and the loading condition. To probe these effects, a preliminary series of high strain-rate (> 105/s) strength plate-impact hole closure experiments were performed on high purity single crystal Tantalum cubes. The orientation of the single crystals with respect to impact/loading were varied to provide data to inform crystal plasticity modeling efforts. The experiments consist of in-situ high-resolution X-ray radiographic imaging of the hole collapse under dynamic compression conditions to infer the material strength via its resistance to closure at increasing levels of plastic strain. The experiments are compared against hydrocode simulation predictions. Here, a comparison with simple elastic perfectly plastic strength model predictions is presented to elucidate the response of the different crystal orientations at high strain-rate and large plastic strains.

36 MATERIALS SCIENCE↗

Time-series learning of latent-space dynamics for reduced-order model closure

In this work, we study the performance of long short-term memory networks (LSTMs) and neural ordinary differential equations (NODEs) in learning latent-space representations of dynamical equations for an advection-dominated problem given by the viscous Burgers equation. Our formulation is devised in a nonintrusive manner with an equation-free evolution of dynamics in a reduced space with the latter being obtained through a proper orthogonal decomposition. In addition, we leverage the sequential nature of learning for both LSTMs and NODEs to demonstrate their capability for closure in systems that are not completely resolved in the reduced space. We assess our hypothesis for two advection-dominated problems given by the viscous Burgers equation. We observe that both LSTMs and NODEs are able to reproduce the effects of the absent scales for our test cases more effectively than does intrusive dynamics evolution through a Galerkin projection. This result empirically suggests that time-series learning techniques implicitly leverage a memory kernel for coarse-grained system closure as is suggested through the Mori–Zwanzig formalism.

97 MATHEMATICS AND COMPUTING↗

A dynamic closure modeling framework for model order reduction of geophysical flows

Here in this paper, a dynamic closure modeling approach has been derived to stabilize the projection-based reduced order models in the long-term evolution of forced-dissipative dynamical systems. To simplify our derivation without losing generalizability, the proposed reduced order modeling (ROM) framework is first constructed by Galerkin projection of the single-layer quasigeostrophic equation, a standard prototype of large-scale general circulation models, onto a set of dominant proper orthogonal decomposition modes. We then propose an eddy viscosity closure approach to stabilize the resulting surrogate model considering the analogy between large eddy simulation (LES) and truncated modal projection. Our efforts, in particular, include the translation of the dynamic subgrid-scale model into our ROM setting by defining a test truncation similar to the test filtering in LES. Finally, the a posteriori analysis shows that our approach is remarkably accurate, allowing us to integrate simulations over long time intervals at a nominally small computational overhead.

42 ENGINEERING↗

Interface learning in fluid dynamics: Statistical inference of closures within micro–macro-coupling models

Many complex multiphysics systems in fluid dynamics involve using solvers with varied levels of approximations in different regions of the computational domain to resolve multiple spatiotemporal scales present in the flow. The accuracy of the solution is governed by how the information is exchanged between these solvers at the interface and several methods have been devised for such coupling problems. In this article, we construct a data-driven model by spatially coupling a microscale lattice Boltzmann method (LBM) solver and macroscale finite difference method (FDM) solver for reaction-diffusion systems. The coupling between the micro-macro solvers has one to many mapping at the interface leading to the interface closure problem, and we propose a statistical inference method based on neural networks to learn this closure relation. The performance of the proposed framework in a bifidelity setting partitioned between the FDM and LBM domain shows its promise for complex systems where analytical relations between micro-macro solvers are not available.

42 ENGINEERING↗