Development of Zeolite Nonwoven for the Adsorption of Radioactive Cesium - 13288

The zeolite nonwoven fabric produced by TDS (Totally Dry System) process has some advantages such as the control of zeolite content, flexibility, strength and water-resistant property depending on the purpose. Hence the zeolite nonwoven fabric is expected for the application in various fields of the decontamination of Cs-contaminated water. In this study, Cs adsorption properties of zeolite nonwoven fabrics were examined by batch experiments, and the radiation stability, thermal stability and chemical durability were evaluated. As for batch adsorption properties, relatively large uptake rate of Cs{sup +} was obtained; the uptake equilibrium attained within 20 min and the uptake (%) was above 95%. The differences in zeolite content had no effects on the Cs{sup +} uptake (%). The uptake (%) of Cs{sup +} in seawater was slightly lowered compared to that in the presence of HNO{sub 3}. The uptake (%) of Cs{sup +} in seawater was estimated to be above 90% after 2 h-shaking, indicating the considerable enhancement of uptake rate compared to the conventional granular zeolites. The uptake (%) of Cs{sup +} for the zeolite high content type was estimated to be above 99% by using {sup 137}Cs tracer. As for the comparison of sealing treatment, the uptake (%) for the zeolite sheet treated with edge sealing was larger than that with rapping treatment. The uptake (%) for the zeolite sheet (zeolite high content type) was estimated to be about 95%, which is independent of sealing treatment and NaOH concentration. As for the stability, the surface morphology and the structure of zeolite sheet were not altered by the treatment with acid and alkaline solutions under the experimental conditions. The zeolite sheets were also stable after {sup 60}Co-γ ray irradiation up to 7.01x10{sup 6} R. On the other hand, color change for both fiber and zeolite and the shrinkage of the fiber were observed after heat treatment at 150 deg. C for 2 h. Thus the considerable enhancement of adsorption properties was observed by using zeolite nonwoven fabrics compared to the conventional granular zeolites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adsorption properties of Cs{sup +} for composite adsorbents and their irradiation stabilities

Novel composite adsorbents using impregnation-precipitation methods have been developed; these fine crystals are loaded in the macro-pores of porous silica gels and zeolites. The 2 following composite adsorbents: KCoFC-NM (NM: natural mordenite, 0.4-1.0 mm), KCoFC-SG (SG: porous silica gel, NH and Q-10)) were prepared by impregnation-precipitation methods. This article presents the results of tests about their characterization, their selective adsorption ability of Cs{sup 137} and their irradiation stability. It is shown that the KCoFC-SG and KCoFC-NM composites are thus efficient for the selective separation of Cs{sup 137} in low-level radioactive waste (LLW) containing highly concentrated sodium nitrate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Potential for Transport of Cesium as Bio-colloids in a High Ionic Strength System

The Waste Isolation Pilot Plant (WIPP) is a deep geologic repository for long-term disposal of transuranic, radioactive waste that is a byproduct from the nation's nuclear defense program. Most likely release scenario → human intrusion (potentially through drilling) (US DOE 1995; 1996). Brine may proceed through the Rustler formation (the most transmissive layer) (Perkins et al., 1999). There is a need to investigate halophilic microbes including their mobility in the Rustler formation and the potential for enhancing transport of cesium as a bio-colloid. Objectives: To quantify the change in mobility of Cs by interaction with microbes (Chromohalobacter) that may be present near Waste Isolation Pilot Plant. What is Chromohalobacter?: a halophilic microbe, isolated from near the WIPP site, able to thrive in the high salt concentrations relevant to the repository. Does the microbe growth phase effect uptake of Cs? Experiments conducted with actively growing and stationary phase Chromohalobacter. Uptake may differ if Cs{sup +} is mistaken for K{sup +} in an actively growing (Log) phase versus stationary phase microbes (not actively reproducing). Materials: 1'' Teflon column packed with 1 gram of dolomite [355-500 μm, CaMg(CO{sub 3}){sub 2}] connected to a syringe pump and fraction collector via Teflon tubing. Chromohalobacter (100 million cells/mL) and dolomite collected near the WIPP. Synthetic brine - 15% NaCl (w/v ∼2.78 M) + 3 mM NaHCO{sub 3}. Methodology: Negative Control 5,000 ppb Cs initially injected into mini-columns with brine. Injection solution was then switched to only brine. Cs Experiments with Stationary Phase Chromo: Set 1: Viable stationary Chromo injected into minicolumns after reaction with 200 ppb Cs. Injection solution was then switched to only brine (without Cs or microbes). Set 2: Stressed stationary Chromo initially injected into mini-columns after reaction with 200 ppb Cs. Then, switched to brine only. Cs Experiments with Log phase Chromo: Set 1: Chromo injected into mini-columns after reaction with 5,000 ppb Cs. Injection then switched to only brine (without Cs or microbes). Set 2: Chromo grown with 5,000 ppb Cs and spiked with additional Cs before injection into columns. Preliminary Conclusions: Cs was not taken up or mobilized by Chromohalobacter in the actively growing or stationary phases or under stressed conditions. Competition may have occurred between Cs and K{sup +} at lower ionic strength, significantly greater concentrations of K{sup +} were present. Results suggest that Chromohalobacter can selectively uptake K{sup +} in the presence of Cs{sup +}. Future Research: K{sup +} and Cs{sup +} uptake will be monitored at high ionic strength in K{sup +} depleted media to consider uptake of Cs in the absence of K.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PRELIMINARY REPORT ON EVALUATION OF POTENTIAL ELUANTS FOR NON-ACID ELUTION OF CESIUM FROM RESORCINOL-FORMALDEHYDE RESIN

Small-column ion exchange (SCIX) units installed in high-level waste tanks to remove Cs-137 from highly alkaline salt solutions are among the waste treatment plans in the DOE-complex. Spherical Resorcinol-Formaldehyde (sRF) is the ion exchange resin selected for use in the Hanford Waste Treatment and Immobilization Plant (WTP). It is also the primary ion exchange material under consideration for SCIX at the Hanford site. The elution step of the multi-step ion exchange process is typically done with 0.5 M nitric acid. An acid eluant is a potential hazard in the event of a spill, leak, etc. because the high-level waste tanks are made of carbon steel. Corrosion and associated structural damage may ensue. Studies are ongoing to explore non-acid elution as an alternative. Batch contact sorption equilibrium screening tests have been conducted with 36 potential non-acid eluants. The sorption tests involve equilibrating each cesium-containing eluant solution with the sRF resin for 48 hours at 25 C in a shaker oven. In the sorption tests, an eluant is deemed to have a high cesium elution potential if it minimizes cesium sorption onto the sRF resin. The top candidates (based on lowest cesium sorption distribution coefficients) include ammonium carbonate, ammonium carbonate/ammonium hydroxide, ammonium bicarbonate, rubidium carbonate, ammonium acetate, ammonium acetate/ammonium hydroxide, ammonium bicarbonate/ammonium hydroxide, calcium chloride, and magnesium chloride. The next phase of testing for this work will focus on the following down selected eluants: Ammonium carbonate, ammonium acetate, calcium acetate, magnesium acetate, nitric acid, and ammonium hydroxide. The next testing phase is a confirmation of the elution ability of the selected eluants. It will mimic a typical sRF cesium ion exchange process i.e., sorption or loading, caustic wash, water rinse, and elution via batch contact sorption and quasi column caustic wash/water rinse/elution. Due to corrosion concerns, calcium acetate and magnesium acetate will be tested instead of calcium chloride and magnesium chloride respectively. Nitric acid is for benchmarking since it is the baseline sRF eluant. The information at hand indicates ammonium hydroxide, while a weak base, may hold promise as an effective eluant. Hence, its inclusion among the eluants to be studied despite the fact that it was not tested as a stand-alone eluant earlier.

36 MATERIALS SCIENCE↗

SELECTIVE REMOVAL OF STRONTIUM AND CESIUM FROM SIMULATED WASTE SOLUTION WITH TITANATE ION EXCHANGERS IN A FILTER CARTRIDGE CONFIGURATION

This report describes experimental results for the selective removal of strontium and cesium from simulated waste solutions using monosodium titanate (MST) and crystalline silicotitanate (CST)-laden filter cartridges. Four types of ion exchange cartridge media (CST and MST designed by both 3M and POROX{reg_sign}) were evaluated. In these proof-of-principle tests effective uptake of both Sr-85 and Cs-137 was observed. However, the experiments were not performed long enough to determine the saturation levels or breakthrough curve for each filter cartridge. POREX{reg_sign} MST cartridges, which by design were based on co-sintering of the active titanates with polyethylene particles, seem to perform as well as the 3M-designed MST cartridges (impregnated filter membrane design) in the uptake of strontium. At low salt simulant conditions (0.29 M Na{sup +}), the instantaneous decontamination factor (D{sub F}) for Sr-85 with the 3M-design MST cartridge measured 26, representing the removal of 96% of the Sr-85. On the other hand, the Sr-85 instantaneous D{sub F} with the POREX{reg_sign} design MST cartridge measured 40 or 98% removal of the Sr-85. Strontium removal with the 3M-design MST and CST cartridges placed in series filter arrangement produced an instantaneous decontamination factor of 41 or 97.6% removal compared to an instantaneous decontamination factor of 368 or 99.7% removal of the strontium with the POREX{reg_sign} MST and CST cartridge design placed in series. At high salt simulant conditions (5.6 M Na{sup +}), strontium removal with 3M-designed MST cartridge only and with 3M-designed MST and CST cartridges operated in a series configuration were identical. The instantaneous decontamination factor and the strontium removal efficiency, under the above configuration, averaged 8.6 and 88%, respectively. There were no POREX{reg_sign} cartridge experiments using the higher ionic strength simulant solution. At low salt simulant conditions, the uptake of Cs-137 with POREX{reg_sign} CST cartridge out performed the 3M-designed CST cartridges. The POREX{reg_sign} CST cartridge, with a Cs-137 instantaneous decontamination factor of 55 and a Cs-137 removal efficiency of 98% does meet the Cs-137 decontamination goals in the low salt simulant liquor. The Cs-137 removal with 3M-designed CST cartridge produced a decontamination factor of 2 or 49% removal efficiency. The Cs-137 performance graph for the 3M-designed CST cartridge showed an early cessation in the uptake of cesium-137. This behavior was not observed with the POREX{reg_sign} CST cartridges. No Cs-137 uptake tests were performed with the POREX{reg_sign} CST cartridges at high salt simulant conditions. The 3M-designed CST cartridges, with an instantaneous Cs-137 decontamination factor of less than 3 and a Cs-137 removal efficiency of less than 50% failed to meet the Cs-137 decontamination goals in both the low and high salt simulant liquors. This poor performance in the uptake of Cs-137 by the 3M CST cartridges may be attributed to fabrication flaws for the 3M-designed CST cartridges. The reduced number of CST membrane wraps per cartridge during the cartridge design phase, from 3-whole wraps to about 1.5, may have contributed to Cs-137 laden simulant channeling/by-pass which led to the poor performance in terms of Cs-137 sorption characteristics for the 3M designed CST cartridges. The grinding of CST ion exchange materials, to reduce the particle size distribution and thus enhance their easy incorporation into the filter membranes and the co-sintering of MST with polyethylene particles, did not adversely affect the sorption kinetics of both CST and MST in the uptake of Cs-137 and Sr-85, respectively. In general, the POREX{reg_sign} based cartridges showed more resistance to simulant flow through the filter cartridges as evidenced by higher pressure differences across the cartridges. Based on these findings they conclude that incorporating MST and CST sorbents into filter membranes represent a promising method for the semi-continuous removal of radioisotopes of strontium and cesium from waste solutions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cesium dynamics in long pulse operation of negative hydrogen ion sources for fusion

Large scale negative hydrogen ion sources operating stable for 1 h (cw mode) are required for the neutral beam heating system of the fusion experiment ITER. The formation of negative hydrogen ions relies on the surface effect for which cesium is evaporated into the source. In order to monitor the cesium dynamics the laser absorption spectroscopy technique is applied to the long pulse test facility MANITU. In the vacuum phase, without plasma operation the evaporation of cesium and the built-up of the cesium in the source are measured. Typical neutral cesium densities are 10{sup 15} m{sup -3}. During plasma operation and after the plasma phase a high cesium dynamics is observed, showing also depletion of cesium during long pulses with low cesium amount. The co-extracted electron current decreases with the cesium amount to a certain level whereas the ion current indicates an optimum density range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cesium control and diagnostics in surface plasma negative ion sources

For efficient and reliable negative ion generation it is very important to improve a cesium control and diagnostics. Laser beam attenuation and resonance fluorescence can be used for measurement of cesium distribution and cesium control. Resonant laser excitation and two-photon excitation can be used for improved cesium ionization and cesium trapping in the discharge chamber. Simple and inexpensive diode lasers can be used for cesium diagnostics and control. Cesium migration along the surface is an important mechanism of cesium escaping. It is important to develop a suppression of cesium migration and cesium accumulation on the extraction system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of heterogeneous water vapor uptake by metal iodide cluster ions via differential mobility analysis-mass spectrometry

The sorption of vapor molecules onto pre-existing nanometer sized clusters is of importance in understanding particle formation and growth in gas phase environments and devising gas phase separation schemes. Here, we apply a differential mobility analyzer-mass spectrometer based approach to observe directly the sorption of vapor molecules onto iodide cluster ions of the form (MI){sub x}M{sup +} (x = 1-13, M = Na, K, Rb, or Cs) in air at 300 K and with water saturation ratios in the 0.01-0.64 range. The extent of vapor sorption is quantified in measurements by the shift in collision cross section (CCS) for each ion. We find that CCS measurements are sensitive enough to detect the transient binding of several vapor molecules to clusters, which shift CCSs by only several percent. At the same time, for the highest saturation ratios examined, we observed CCS shifts of up to 45%. For x < 4, cesium, rubidium, and potassium iodide cluster ions are found to uptake water to a similar extent, while sodium iodide clusters uptake less water. For x ≥ 4, sodium iodide cluster ions uptake proportionally more water vapor than rubidium and potassium iodide cluster ions, while cesium iodide ions exhibit less uptake. Measured CCS shifts are compared to predictions based upon a Kelvin-Thomson-Raoult (KTR) model as well as a Langmuir adsorption model. We find that the Langmuir adsorption model can be fit well to measurements. Meanwhile, KTR predictions deviate from measurements, which suggests that the earliest stages of vapor uptake by nanometer scale species are not well described by the KTR model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Negative ion source development for fusion application (invited)

Giant negative ion sources, producing high-current of several tens amps with high energy of several hundreds keV to 1 MeV, are required for a neutral beam injector (NBI) in a fusion device. The giant negative ion sources are cesium-seeded plasma sources, in which the negative ions are produced on the cesium-covered surface. Their characteristic features are discussed with the views of large-volume plasma production, large-area beam acceleration, and high-voltage dc holding. The international thermonuclear experimental reactor NBI employs a 1 MeV-40 A of deuterium negative ion source, and intensive development programs for the rf-driven source plasma production and the multistage electrostatic acceleration are in progress, including the long pulse operation for 3600 s. Present status of the development, as well as the achievements of the giant negative ion sources in the working injectors, is also summarized.

43 PARTICLE ACCELERATORS↗

Evaluation of Potential Eluants for Non-Acid Elution of Cesium From Resorcinol-Formaldehyde Resin

Small-column ion exchange (SCIX) units installed in high-level waste tanks to remove Cs-137 from highly alkaline salt solutions are among the waste treatment plans in the DOE-complex. Spherical Resorcinol-Formaldehyde (sRF) is the ion exchange resin selected for use in the Hanford Waste Treatment and Immobilization Plant (WTP). It is also the primary ion exchange material under consideration for SCIX at the Hanford site. The elution step of the multi-step ion exchange process is typically done with 0.5 M nitric acid. An acid eluant is a potential hazard in the event of a spill, leak, etc. because the high-level waste tanks are made of carbon steel. Corrosion and associated structural damage may ensue. A study has been conducted to explore non-acid elution as an alternative. Batch contact sorption equilibrium screening tests have been conducted with 36 potential non-acid eluants. The sorption tests involve equilibrating each cesium-containing eluant solution with the sRF resin for 48 hours at 25 C in a shaker oven. In the sorption tests, an eluant is deemed to have a high cesium elution potential if it minimizes cesium sorption onto the sRF resin. The top candidates (based on lowest cesium sorption distribution coefficients) include ammonium carbonate, ammonium carbonate/ammonium hydroxide, ammonium bicarbonate, rubidium carbonate, ammonium acetate, ammonium acetate/ammonium hydroxide, ammonium bicarbonate/ammonium hydroxide, calcium chloride, and magnesium chloride. A select few of the top candidate eluants from the screening tests were subjected to actual sorption (loading) and elution tests to confirm their elution ability. The actual sorption (loading) and elution tests mimicked the typical sRF-cesium ion exchange process (i.e., sorption or loading, caustic wash, water rinse, and elution) via batch contact sorption and quasi column caustic wash/water rinse/elution. The eluants tested included ammonium carbonate, ammonium acetate, calcium acetate, magnesium acetate, and nitric acid. Calcium acetate and magnesium acetate were substitutes for calcium chloride and magnesium chloride respectively due to corrosion concerns. Nitric acid was selected for benchmarking since it is the baseline cesium eluant for sRF resin. The cesium elution performance of ammonium carbonate and ammonium acetate was approximately the same as the benchmark eluant, nitric acid. Ninety-seven (97), 94, and 100% percent of the cesium sorbed or loaded were eluted by ammonium carbonate, ammonium acetate, and nitric acid was respectively. The performance of calcium acetate and magnesium acetate, on the other hand, was mediocre. Percent elution was 16 and 8 respectively.

36 MATERIALS SCIENCE↗

Molecular and negative ion production by a standard electron cyclotron resonance ion source

Molecular and negative ion beams, usually produced in special ion sources, play an increasingly important role in fundamental and applied atomic physics. The ATOMKI-ECRIS is a standard ECR ion source, designed to provide highly charged ion (HCI) plasmas and beams. In the present work, H{sup -}, O{sup -}, OH{sup -}, O{sub 2}{sup -}, C{sup -}, C{sub 60}{sup -} negative ions and H{sub 2}{sup +}, H{sub 3}{sup +}, OH{sup +}, H{sub 2}O{sup +}, H{sub 3}O{sup +}, O{sub 2}{sup +} positive molecular ions were generated in this HCI-ECRIS. Without any major modification in the source and without any commonly applied tricks (such as usage of cesium or magnetic filter), negative ion beams of several {mu}A and positive molecular ion beams in the mA range were successfully obtained.

43 PARTICLE ACCELERATORS↗

REMOVAL OF CESIUM FROM SAVANNAH RIVER SITE WASTE WITH SPHERICAL RESORCINOL FORMALDEHYDE ION EXCHANGE RESIN EXPERIMENTAL TESTS

A principal goal at the Savannah River Site (SRS) is to safely dispose of the large volume of liquid nuclear waste held in many storage tanks. In-tank ion exchange (IX) columns are being considered for cesium removal. The spherical form of resorcinol formaldehyde ion exchange resin (sRF) is being evaluated for decontamination of dissolved saltcake waste at SRS, which is generally lower in potassium and organic components than Hanford waste. The sRF performance with SRS waste was evaluated in two phases: resin batch contacts and IX column testing with both simulated and actual dissolved salt waste. The tests, equipment, and results are discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗