Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CARLO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

"K-Effective of the World" and Other Concerns for Monte Carlo Eigenvalue Calculations

Monte Carlo methods have been used to compute k eff and the fundamental model eigenfunction of critical systems since the 1950s. Despite the sophistication of today's Monte Carlo codes for representing realistic geometry and physics interactions, correct results can be obtained in criticality problems only if users pay attention to source convergence in the Monte Carlo iterations and to running a sufficient number of neutron histories to adequately sample all significant regions of the problem. Recommended best practices for criticality calculations are reviewed and applied to several practical problems for nuclear reactors and criticality safety, including the "K-effective of the World" problem. Numerical results illustrate the concerns about convergence and bias. The general conclusion is that with today's high-performance computers, improved understanding of the theory, new tools for diagnosing convergence (e.g., Shannon entropy of the fission distribution), and clear practical guidance for performing calculations, practitioners will have a greater degree of confidence than ever of obtaining correct results for Monte Carlo criticality calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-Throughput Computation and the Applicability of Monte Carlo Integration in Fatigue Load Estimation of Floating Offshore Wind Turbines

Long-term fatigue loads for floating offshore wind turbines are hard to estimate because they require the evaluation of the integral of a highly nonlinear function over a wide variety of wind and wave conditions. Current design standards involve scanning over a uniform rectangular grid of metocean inputs (e.g., wind speed and direction and wave height and period), which becomes intractable in high dimensions as the number of required evaluations grows exponentially with dimension. Monte Carlo integration offers a potentially efficient alternative because it has theoretical convergence proportional to the inverse of the square root of the number of samples, which is independent of dimension. In this paper, we first report on the integration of the aeroelastic code FAST into NREL's systems engineering tool, WISDEM, and the development of a high-throughput pipeline capable of sampling from arbitrary distributions, running FAST on a large scale, and postprocessing the results into estimates of fatigue loads. Second, we use this tool to run a variety of studies aimed at comparing grid-based and Monte Carlo-based approaches with calculating long-term fatigue loads. We observe that for more than a few dimensions, the Monte Carlo approach can represent a large improvement in computational efficiency, but that as nonlinearity increases, the effectiveness of Monte Carlo is correspondingly reduced. The present work sets the stage for future research focusing on using advanced statistical methods for analysis of wind turbine fatigue as well as extreme loads.

17 WIND ENERGY↗

Monte Carlo capabilities of the SCALE code system

SCALE is a broadly used suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, licensees, and research institutions around the world have used SCALE for nuclear safety analysis and design. SCALE provides a “plug-and-play” framework that includes three deterministic and three Monte Carlo radiation transport solvers that can be selected based on the desired solution, including hybrid deterministic/Monte Carlo simulations. SCALE includes the latest nuclear data libraries for continuous-energy and multigroup radiation transport as well as activation, depletion, and decay calculations. SCALE’s graphical user interfaces assist with accurate system modeling, visualization, and convenient access to desired results. SCALE 6.2 will provide several new capabilities and significant improvements in many existing features, especially with expanded continuous-energy Monte Carlo capabilities for criticality safety, shielding, depletion, and sensitivity and uncertainty analysis. Finally, an overview of the Monte Carlo capabilities of SCALE is provided here, with emphasis on new features for SCALE 6.2.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo fuel burnup analyses of the Accelerator-Driven Subcritical systems

Here, we discuss the Monte Carlo fuel burnup analysis performed for the Argonne National Laboratory (ANL) Accelerator-Driven Subcritical (ADS) conceptual design. The ANL ADS conceptual design was determined to dispose of the 131 tons of Minor Actinides (MA) fuel of the current United States Spent Nuclear Fuel (SNF) inventory. It uses a neutron source from 1 GeV 25MW proton beam with the liquid lead target to drive the subcritical fission assembly. It utilizes the liquid metal slurry fuel concept to load the MAs fuel. The subcritical fission assembly has a neutron multiplication factor of 0.98. The total fission power generated in the system is about 2.67 GW. The system is designed to operate for 35 full power years. Monte Carlo fuel burnup analyses were performed to calculate the amount of MAs consumed by the ANL ADS conceptual design. The MCNP6 computer program was used to simulate the high energy physics of the protons striking the liquid lead target for generating the neutron source. The MCB5 and SERPENT Monte Carlo burnup computer programs were used to simulate the fuel burnup during the ADS operation. In the ANL ADS conceptual configuration, the reactivity loss during the fuel burnup is compensated by adding fresh fuel into the subcritical assembly. In this paper, both batch and continuous fueling modes are examined. The fresh fuel particles are loaded into the slurry fuel carrier at the beginning of each burnup step of the batch-fueling mode and loaded continuously into the slurry fuel carrier during the operation in the continuous fueling mode. Monte Carlo fuel burnup analyses show that one ANL ADS conceptual design can consume about 25.7 tons of MAs fuel during the 35 full power years with the continuous fueling mode. About five units is required to dispose of the 131 tons of MAs

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CASM Monte Carlo: Calculations of the thermodynamic and kinetic properties of complex multicomponent crystals

Monte Carlo techniques play a central role in statistical mechanics approaches that connect macroscopic thermodynamic and kinetic properties to the electronic structure of a material. This paper describes the implementation of Monte Carlo techniques for the study of multicomponent crystalline materials within the Clusters Approach to Statistical Mechanics (CASM) software suite, and demonstrates their use in model systems to calculate free energies and kinetic coefficients, study phase transitions, and construct phase diagrams from first principles. Many crystal structures are complex, with multiple sublattices occupied by differing sets of chemical species, along with the presence of vacancies or interstitial species. This imposes constraints on concentration variables, the form of thermodynamic potentials, and the values of kinetic transport coefficients. The framework used by CASM to formulate thermodynamic potentials and kinetic transport coefficients accounting for arbitrarily complex crystal structures is presented and demonstrated with examples of increasing complexity. Additionally, an overview of the capabilities of the CASM software specific to Monte Carlo methods is given, and a new CASM software package is introduced, casm-flow, which helps automate the setup, submission, management, and analysis of Monte Carlo simulations.

Cluster expansion↗

A kinetic Monte Carlo method on super-lattices for the study of the defect formation in the growth of close packed structures

A modified Kinetic Lattice Monte Carlo model has been developed to predict growth rate regimes and defect formation in the case of the homo-epitaxial growth of close packed crystalline structures. The model is an improvement over standard Monte Carlo algorithms, which usually retain fixed atom positions and bond partners indicative of perfect crystal lattices. Indeed, we extend the concepts of Monte Carlo growth simulations on super-lattices containing additional sites (defect sites) with respect to those of the reference material. This extension implies a reconsideration of the energetic mapping, which is extensively presented, and allows to describe a complex phenomenology that is out of accessibility of standard stochastic approaches. Results obtained using the Kawasaki and the Bond-Counting rules for the transition probability of the Monte Carlo event are discussed in details. These results demonstrate how the defect types (local or extended), the formation mechanisms and the defect generation regimes can be characterized using our approach.

36 MATERIALS SCIENCE↗

A hybrid transport-diffusion Monte Carlo method for frequency-dependent radiative-transfer simulations

Discrete Diffusion Monte Carlo (DDMC) is a technique for increasing the efficiency of Implicit Monte Carlo radiative-transfer simulations in optically thick media. In DDMC, particles take discrete steps between spatial cells according to a discretized diffusion equation. Each discrete step replaces many smaller Monte Carlo steps, thus improving the efficiency of the simulation. In this paper, we present an extension of DDMC for frequency-dependent radiative transfer. We base our new DDMC method on a frequency-integrated diffusion equation for frequencies below a specified threshold, as optical thickness is typically a decreasing function of frequency. Above this threshold we employ standard Monte Carlo, which results in a hybrid transport-diffusion scheme. With a set of frequency-dependent test problems, we confirm the accuracy and increased efficiency of our new DDMC method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Obtaining identical results with double precision global accuracy on different numbers of processors in parallel particle Monte Carlo simulations

We describe and compare different approaches for achieving numerical reproducibility in photon Monte Carlo simulations. Reproducibility is desirable for code verification, testing, and debugging. Parallelism creates a unique problem for achieving reproducibility in Monte Carlo simulations because it changes the order in which values are summed. This is a numerical problem because double precision arithmetic is not associative. Parallel Monte Carlo, both domain replicated and decomposed simulations, will run their particles in a different order during different runs of the same simulation because the non-reproducibility of communication between processors. In addition, runs of the same simulation using different domain decompositions will also result in particles being simulated in a different order. In [1], a way of eliminating non-associative accumulations using integer tallies was described. This approach successfully achieves reproducibility at the cost of lost accuracy by rounding double precision numbers to fewer significant digits. This integer approach, and other extended and reduced precision reproducibility techniques, are described and compared in this work. Increased precision alone is not enough to ensure reproducibility of photon Monte Carlo simulations. Non-arbitrary precision approaches require a varying degree of rounding to achieve reproducibility. For the problems investigated in this work double precision global accuracy was achievable by using 100 bits of precision or greater on all unordered sums which where subsequently rounded to double precision at the end of every time-step.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Metropolis Monte Carlo method with CUDA enabled Graphic Processing Units

We present a CPU–GPU system for runtime acceleration of large molecular simulations using GPU computation and memory swaps. The memory architecture of the GPU can be used both as container for simulation data stored on the graphics card and as floating-point code target, providing an effective means for the manipulation of atomistic or molecular data on the GPU. To fully take advantage of this mechanism, efficient GPU realizations of algorithms used to perform atomistic and molecular simulations are essential. Our system implements a versatile molecular engine, including inter-molecule interactions and orientational variables for performing the Metropolis Monte Carlo (MMC) algorithm, which is one type of Markov chain Monte Carlo. By combining memory objects with floating-point code fragments we have implemented an MMC parallel engine that entirely avoids the communication time of molecular data at runtime. Our runtime acceleration system is a forerunner of a new class of CPU–GPU algorithms exploiting memory concepts combined with threading for avoiding bus bandwidth and communication. The testbed molecular system used here is a condensed phase system of oligopyrrole chains. A benchmark shows a size scaling speedup of 60 for systems with 210,000 pyrrole monomers. Our implementation can easily be combined with MPI to connect in parallel several CPU–GPU duets. -- Highlights: •We parallelize the Metropolis Monte Carlo (MMC) algorithm on one CPU—GPU duet. •The Adaptive Tempering Monte Carlo employs MMC and profits from this CPU—GPU implementation. •Our benchmark shows a size scaling-up speedup of 62 for systems with 225,000 particles. •The testbed involves a polymeric system of oligopyrroles in the condensed phase. •The CPU—GPU parallelization includes dipole—dipole and Mie—Jones classic potentials.

97 MATHEMATICS AND COMPUTING↗

The many-body Wigner Monte Carlo method for time-dependent ab-initio quantum simulations

The aim of ab-initio approaches is the simulation of many-body quantum systems from the first principles of quantum mechanics. These methods are traditionally based on the many-body Schrödinger equation which represents an incredible mathematical challenge. In this paper, we introduce the many-body Wigner Monte Carlo method in the context of distinguishable particles and in the absence of spin-dependent effects. Despite these restrictions, the method has several advantages. First of all, the Wigner formalism is intuitive, as it is based on the concept of a quasi-distribution function. Secondly, the Monte Carlo numerical approach allows scalability on parallel machines that is practically unachievable by means of other techniques based on finite difference or finite element methods. Finally, this method allows time-dependent ab-initio simulations of strongly correlated quantum systems. In order to validate our many-body Wigner Monte Carlo method, as a case study we simulate a relatively simple system consisting of two particles in several different situations. We first start from two non-interacting free Gaussian wave packets. We, then, proceed with the inclusion of an external potential barrier, and we conclude by simulating two entangled (i.e. correlated) particles. The results show how, in the case of negligible spin-dependent effects, the many-body Wigner Monte Carlo method provides an efficient and reliable tool to study the time-dependent evolution of quantum systems composed of distinguishable particles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Monte Carlo method for the simulation of coagulation and nucleation based on weighted particles and the concepts of stochastic resolution and merging

Monte Carlo simulations based on weighted simulation particles can solve a variety of population balance problems and allow thus to formulate a solution-framework for many chemical engineering processes. This study presents a novel concept for the calculation of coagulation rates of weighted Monte Carlo particles by introducing a family of transformations to non-weighted Monte Carlo particles. The tuning of the accuracy (named ‘stochastic resolution’ in this paper) of those transformations allows the construction of a constant-number coagulation scheme. Furthermore, a parallel algorithm for the inclusion of newly formed Monte Carlo particles due to nucleation is presented in the scope of a constant-number scheme: the low-weight merging. This technique is found to create significantly less statistical simulation noise than the conventional technique (named ‘random removal’ in this paper). Both concepts are combined into a single GPU-based simulation method which is validated by comparison with the discrete-sectional simulation technique. Two test models describing a constant-rate nucleation coupled to a simultaneous coagulation in 1) the free-molecular regime or 2) the continuum regime are simulated for this purpose.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of the interindividual human variation in bioactivation of methyleugenol using physiologically based kinetic modeling and Monte Carlo simulations

The present study aims at predicting the level of formation of the ultimate carcinogenic metabolite of methyleugenol, 1′-sulfooxymethyleugenol, in the human population by taking variability in key bioactivation and detoxification reactions into account using Monte Carlo simulations. Depending on the metabolic route, variation was simulated based on kinetic constants obtained from incubations with a range of individual human liver fractions or by combining kinetic constants obtained for specific isoenzymes with literature reported human variation in the activity of these enzymes. The results of the study indicate that formation of 1′-sulfooxymethyleugenol is predominantly affected by variation in i) P450 1A2-catalyzed bioactivation of methyleugenol to 1′-hydroxymethyleugenol, ii) P450 2B6-catalyzed epoxidation of methyleugenol, iii) the apparent kinetic constants for oxidation of 1′-hydroxymethyleugenol, and iv) the apparent kinetic constants for sulfation of 1′-hydroxymethyleugenol. Based on the Monte Carlo simulations a so-called chemical-specific adjustment factor (CSAF) for intraspecies variation could be derived by dividing different percentiles by the 50th percentile of the predicted population distribution for 1′-sulfooxymethyleugenol formation. The obtained CSAF value at the 90th percentile was 3.2, indicating that the default uncertainty factor of 3.16 for human variability in kinetics may adequately cover the variation within 90% of the population. Covering 99% of the population requires a larger uncertainty factor of 6.4. In conclusion, the results showed that adequate predictions on interindividual human variation can be made with Monte Carlo-based PBK modeling. For methyleugenol this variation was observed to be in line with the default variation generally assumed in risk assessment. - Highlights: • Interindividual human differences in methyleugenol bioactivation were simulated. • This was done using in vitro incubations, PBK modeling and Monte Carlo simulations. • Major enzymatic reactions causing interindividual differences were identified. • A chemical-specific adjustment factor (CASF) for intraspecies variation was derived. • The default uncertainty factor for kinetic human variability covers 90% of population.

60 APPLIED LIFE SCIENCES↗

Analytic treatment of source photon emission times to reduce noise in implicit Monte Carlo calculations

Statistical uncertainty is inherent to any Monte Carlo simulation of radiation transport problems. In space-angle-frequency independent radiative transfer calculations, the uncertainty in the solution is entirely due to random sampling of source photon emission times. We have developed a modification to the Implicit Monte Carlo algorithm that eliminates noise due to sampling of the emission time of source photons. In problems that are independent of space, angle, and energy, the new algorithm generates a smooth solution, while a standard implicit Monte Carlo solution is noisy. For space- and angle-dependent problems, the new algorithm exhibits reduced noise relative to standard implicit Monte Carlo in some cases, and comparable noise in all other cases. In conclusion, the improvements are limited to short time scales; over long time scales, noise due to random sampling of spatial and angular variables tends to dominate the noise reduction from the new algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Monte Carlo Thermal Radiative Transfer Solver with Nonlinear Elimination

Here in this paper, we present a new Monte Carlo method for solving the thermal radiative transfer (TRT) equations via the method of nonlinear elimination (NLEM). This method is inspired by the previous application of NLEM to thermal radiation diffusion. Our approach, called diffusion accelerated Implicit Monte Carlo (DAIMC), is a hybrid technique which combines a Monte Carlo method for solving a purely-absorbing transport equation and a diffusion solution that accounts for effective scattering, or absorption–reemission. The method aims to improve the implicitness of the traditional implicit Monte Carlo (IMC) method. We derive DAIMC generally for 3D Cartesian geometries, but in this paper, we present results and analysis in 1D slab geometry. These preliminary results indicate that DAIMC implementations may provide more accurate and robust TRT solutions than IMC in certain test problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo simulations of time-of-flight PET with double-ended readout: calibration, coincidence resolving times and statistical lower bounds

Here, this paper demonstrates through Monte Carlo simulations that a practical positron emission tomograph with (1) deep scintillators for efficient detection, (2) double-ended readout for depth-of-interaction information, (3) fixed-level analog triggering, and (4) accurate calibration and timing data corrections can achieve a coincidence resolving time (CRT) that is not far above the statistical lower bound. One Monte Carlo algorithm simulates a calibration procedure that uses data from a positron point source. Annihilation events with an interaction near the entrance surface of one scintillator are selected, and data from the two photodetectors on the other scintillator provide depth-dependent timing corrections. Another Monte Carlo algorithm simulates normal operation using these corrections and determines the CRT. A third Monte Carlo algorithm determines the CRT statistical lower bound by generating a series of random interaction depths, and for each interaction a set of random photoelectron times for each of the two photodetectors. The most likely interaction times are determined by shifting the depth-dependent probability density function to maximize the joint likelihood for all the photoelectron times in each set. Example calculations are tabulated for different numbers of photoelectrons and photodetector time jitters for three 3 × 3 × 30 mm 3 scintillators: Lu 2 SiO 5 :Ce,Ca (LSO), LaBr 3 :Ce, and a hypothetical ultra-fast scintillator. To isolate the factors that depend on the scintillator length and the ability to estimate the DOI, CRT values are tabulated for perfect scintillator-photodetectors. For LSO with 4000 photoelectrons and single photoelectron time jitter of the photodetector J = 0.2 ns (FWHM), the CRT value using the statistically weighted average of corrected trigger times is 0.098 ns FWHM and the statistical lower bound is 0.091 ns FWHM. For LaBr 3 :Ce with 8000 photoelectrons and J = 0.2 ns FWHM, the CRT values are 0.070 and 0.063 ns FWHM, respectively. For the ultra-fast scintillator with 1 ns decay time, 4000 photoelectrons, and J = 0.2 ns FWHM, the CRT values are 0.021 and 0.017 ns FWHM, respectively. Lastly, the examples also show that calibration and correction for depth-dependent variations in pulse height and in annihilation and optical photon transit times are necessary to achieve these CRT values.

60 APPLIED LIFE SCIENCES↗

Static Self-Energy and Effective Mass of the Homogeneous Electron Gas from Quantum Monte Carlo Calculations

We discuss the methodology of quantum Monte Carlo calculations of the effective mass based on the static self-energy Σ(k,0). We then use variational Monte Carlo calculations of Σ(k,0) of the homogeneous electron gas at various densities to obtain results very close to perturbative G 0 W 0 calculations for values of the density parameter 1 ≤ r s ≤ 10. Here, the obtained values for the effective mass are close to diagrammatic Monte Carlo results and disagree with previous quantum Monte Carlo calculations based on a heuristic mapping of excitation energies to those of an ideal gas.

36 MATERIALS SCIENCE↗

Coupling Deterministic and Monte Carlo Transport Methods for the Simulation of Gamma-Ray Spectroscopy Scenarios

Radiation transport modeling methods used in the radiation detection community fall into one of two broad categories: stochastic (Monte Carlo) and deterministic. Monte Carlo methods are typically the tool of choice for simulating gamma-ray spectrometers operating in homeland and national security settings (e.g. portal monitoring of vehicles or isotope identification using handheld devices), but deterministic codes that discretize the linear Boltzmann transport equation in space, angle, and energy offer potential advantages in computational efficiency for many complex radiation detection problems. This paper describes the development of a scenario simulation framework based on deterministic algorithms. Key challenges include: formulating methods to automatically define an energy group structure that can support modeling of gamma-ray spectrometers ranging from low to high resolution; combining deterministic transport algorithms (e.g. ray-tracing and discrete ordinates) to mitigate ray effects for a wide range of problem types; and developing efficient and accurate methods to calculate gamma-ray spectrometer response functions from the deterministic angular flux solutions. The software framework aimed at addressing these challenges is described and results from test problems that compare coupled deterministic-Monte Carlo methods and purely Monte Carlo approaches are provided.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

An EGSnrc Monte Carlo-calculated database of TG-43 parameters

Monte Carlo methods are used to calculate a complete TG-43 dosimetry parameter data set for 27 low-energy photon emitting brachytherapy sources (18 {sup 125}I and 9 {sup 103}Pd). All Monte Carlo calculations are performed using the EGSnrc user-code BrachyDose. TG-43 dosimetry parameters, including dose rate constants, radial dose functions (with functional fitting parameters), and anisotropy data, are calculated with finer spatial resolution, greater range of distances, and smaller uncertainties than data currently available in the literature for many of these sources. In particular, for most of the seeds, this is the first time that anisotropy data have been tabulated at distances less than 0.5 cm from the source. These calculations employ the state-of-the-art XCOM photon cross sections, and detailed source geometries are modeled using Yegin's multigeometry package. This data set serves as a completely independent verification of the currently available dosimetry parameters calculated using other Monte Carlo codes, including MCNP and PTRAN. This report also describes the Carleton Laboratory for Radiotherapy Physics TG-43 Parameter Database, a publicly accessible web site (at http://www.physics.carleton.ca/clrp/seed{sub d}atabase/) through which all of the data calculated for this study can be accessed. Also available on the web site are descriptions of the methods and Monte Carlo models used in this study and comparisons of data calculated in this study with data calculated by other authors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗