Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CARDIOVASCULAR SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Cerebrovascular Accident Incidence in the NASA Astronaut Population

The development of atherosclerosis is strongly associated with an increased risk for cerebrovascular accidents (CVA), including stroke and transient ischemic attacks (TIA). Certain unique occupational exposures that individuals in the NASA astronaut corps face, specifically high-performance aircraft training, SCUBA training, and spaceflight, are hypothesized to cause changes to the cardiovascular system. These changes, which include (but are not limited to) oxidative damage as a result of radiation exposure and circadian rhythm disturbance, increased arterial stiffness, and increased carotid-intima-media thickness (CIMT), may contribute to the development of atherosclerosis and subsequent CVA. The purpose of this study was to review cases of CVA in the NASA astronaut corps and describe the comorbidities and occupational exposures associated with CVA.

LaPelusa, Michael B.↗

Effects of Spaceflight on Venous and Arterial Compliance

The visual impairment and intracranial pressure (VIIP) syndrome is a spaceflight-associated set of symptoms affecting more than 50% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures (e.g. optic disc edema, choroidal folds, and globe flattening) and is hypothesized to be related to elevated intracranial pressure secondary to a cephalad fluid shift. However, ocular symptoms have not been replicated in subjects completing prolonged bed rest, a well-accepted spaceflight analog. Altered vascular compliance along with spaceflight factors such as diet, radiation exposure, or environmental factors may cause alterations in the cardiovascular system that contribute to the manifestation of ocular changes. Loss of visual acuity could be a significant threat to crew health and performance during and after an exploration mission and may have implications for years post-flight. The overall objective of this project is to determine if spaceflight alters vascular compliance and whether such an adaptation is related to the incidence of VIIP. This objective will be met by completing three separate but related projects.

Ribeiro, L. C.↗

Modeling Microgravity Induced Fluid Redistribution Autoregulatory and Hydrostatic Enhancements

Space flight induces a marked cephalad (headward) redistribution of blood and interstitial fluid potentially resulting in a loss of venous tone and reduction in heart muscle efficiency upon introduction into the microgravity environment. Using various types of computational models, we are investigating how this fluid redistribution may induce intracranial pressure changes, relevant to reported reductions in astronaut visual acuity, part of the Visual Impairment and Intracranial Pressure (VIIP) syndrome. Methods: We utilize a lumped parameter cardiovascular system (CVS) model, augmented by compartments comprising the cerebral spinal fluid (CSF) space, as the primary tool to describe how microgravity, and the associated lack of hydrostatic gradient, impacts fluid redistribution. Models of ocular fluid pressures and biomechanics then accept the output of the above model as boundary condition input to allow more detailed, local analysis (see IWS Abstract by Ethier et al.). Recently, we enhanced the capabilities our previously reported CVS model through the implementation of robust autoregulatory mechanisms and a more fundamental approach to the implementation of hydrostatic mechanisms. Modifying the approach of Blanco et al., we implemented auto-regulation in a quasi-static manner, as an averaged effect across the span of one heartbeat. This approach reduced the higher frequency perturbations from the regulatory mechanism and was intended to allow longer simulation times (days) than models that implement within-beat regulatory mechanisms (minutes). A more fundamental approach to hydrostatics was implemented by a quasi-1D approach, in which compartment descriptions include compartment length, orientation and relative position, allowed for modeling of body orientation, relative body positioning and, in the future, alternative gravity environments. At this time the inclusion of hydrostatic mechanisms supplies additional capabilities to train and validate the CVS model with terrestrial data. Results and Conclusions: With the implementation of auto-regulation and hydrostatic modeling capabilities, the model performs as expected in the maintaining the CA (Central Artery) compartment pressure when simulating orientations ranging from supine to standing. The model appears to generally overpredict heart rate and thus cardiac output, possibly indicating sensitivity to the nominal heart rate, which is used as an initial set point of the regulation mechanisms. Despite this sensitivity, the model performs consistently for many hours of simulation time, indicating the success of our quasi-static implementation approach.

biomechanics↗

VESsel GENeration Analysis (VESGEN): Innovative Vascular Mappings for Astronaut Exploration Health Risks and Human Terrestrial Medicine

Currently, astronauts face significant health risks in future long-duration exploration missions such as colonizing the Moon and traveling to Mars. Numerous risks include greatly increased radiation exposures beyond the low earth orbit (LEO) of the ISS, and visual and ocular impairments in response to microgravity environments. The cardiovascular system is a key mediator in human physiological responses to radiation and microgravity. Moreover, blood vessels are necessarily involved in the progression and treatment of vascular-dependent terrestrial diseases such as cancer, coronary vessel disease, wound-healing, reproductive disorders, and diabetes. NASA developed an innovative, globally requested beta-level software, VESsel GENeration Analysis (VESGEN) to map and quantify vascular remodeling for application to astronaut and terrestrial health challenges. VESGEN mappings of branching vascular trees and networks are based on a weighted multi-parametric analysis derived from vascular physiological branching rules. Complex vascular branching patterns are determined by biological signaling mechanisms together with the fluid mechanics of multi-phase laminar blood flow.

astronaut↗

Evaluation of Human Spaceflight-Related Tissue Weight Relief Using Whole Body Finite Element Model Simulations

Tissue Weight Relief (TWR) is a physiological condition observed in human spaceflight. It not only impacts the injury biomechanics of soft tissue but also the physiological responses of the cardiovascular system both due to fluid redistribution and the effect of tissue-related transmural pressure on the large venous blood vessels. Understanding the effects of tissue weight relief is especially important because of the role it may play in understanding the cause of Space Associated Neuro-Ocular Syndrome (SANS). SANS can be characterized by a number of ocular changes which reduce visual acuity and SANS related symptoms occur in up to 51% of astronauts. A prevailing theory for the causation of SANS is that of headward (cephalad) fluid shift and a prolonged increase of Intracranial Pressure (ICP) similar to intracranial hypertension, which is not fully supported by the experimental data or astronaut symptom reporting. However, it is still believed that SANS is caused by a pressure change in the eye and the surrounding tissues. It has been proposed that TWR plays a substantial role in affecting internal pressures and fluid shifts in microgravity. In this effort, two whole-body Finite Element (FE) models – Elemance and THUMS – are used to ascertain the microgravity-associated TWR of the musculature surrounding the lower body veins. Elemance and THUMS are physics-based computational models that have been validated and verified for several automotive and domestic applications, and as such, can simulate the relief of soft tissue weight due to changes in the gravitation vector. Specifically, the current effort modeled the transition of the gravitational vector from 1G to 0G, applied across the whole-body model in a supine position. For each 1G to 0G transition simulation, the lower body vein’s transmural pressure-time profile was extracted and averaged around the anterior portion of the thigh muscle. The ascertained transmural pressure changes from 1G to 0G transition are given in Figure 1 for the Elemance and the THUMS FE models. The transmural pressure changes of 10 mmHg and 21 mmHg are in the same order of magnitude as Lu’s value of 44 mmHg. It is to be noted that Lu implemented a 0D to 1D lumped parameter model and the Elemance and THUMS are 3D higher order computational models. This proof-of-concept approach demonstrates that TWR pressure can be adequately estimated with in silico techniques however, further in silico investigations need to be conducted to address the unique contributions to the transmural pressure from each of the computational models.

Finite element modeling↗

Dose-Dependent Analysis of Acute Medical Effects of Mixed Neutron-Gamma Radiation from Selected Severe Uranium-235 or Plutonium-239 Criticality Accidents in USSR, United States and Argentina

Eight of the most severe cases of acute radiation disease (ARS) known to have occurred in man (as the result of criticality accidents) had survival times less than 120 hours (herein defined as “early death”). These accidents were analyzed and are discussed with respect to the specific accident scenarios and the resulting accident specific, mixed neutron-gamma radiation clinical dose distributions. Our analysis concludes that the cardiovascular system appears to be the most critical organ system failure for causing “early death”, following approximate total body, mixed gamma-neutron irradiations doses greater than 40–50 Gy. The clinical data also suggests that there is definite chest dose dependence in the resulting survival times for these eight workers, who unfortunately suffered profound radiation injury and unusual clinical effects from such high dose radiation exposures. In addition “toxemic syndrome” is correlated with the irradiation of large volumes of soft tissues. Doses to the hands or legs greater than 80 –100 Gy or radiation lung injury also play significant, but secondary, roles for causing “early death”, in accidents delivering chest doses greater than 50 Gy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cardiovascular and other dynamic systems in long-term space flight

The paper examines the physiology of the cardiovascular system, and to a lesser extent the endocrine, renal, and hematopoietic systems. The paper highlights the aspects of these areas that are most pertinent to space manufacturing, i.e., working in space. Areas covered include the physiological costs of working in microgravity and partial gravity (e.g., the moon or Mars), countermeasures to potentially adverse physiological adaptations, and problems associated with return to earth after long periods of weightlessness.

Tipton, David A.↗

Nonlinear systems dynamics in cardiovascular physiology: The heart rate delay map and lower body negative pressure

A preliminary study of the applicability of nonlinear dynamic systems analysis techniques to low body negative pressure (LBNP) studies. In particular, the applicability of the heart rate delay map is investigated. It is suggested that the heart rate delay map has potential as a supplemental tool in the assessment of subject performance in LBNP tests and possibly in the determination of susceptibility to cardiovascular deconditioning with spaceflight.

Hooker, John C.↗

Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 2

The development of a cardiovascular monitoring system to noninvasively monitor the blood pressure and heart rate using pulse wave velocity was described. The following topics were covered: (1) pulse wave velocity as a measure of arterial blood pressure, (2) diastolic blood pressure and pulse wave velocity in humans, (3) transducer development for blood pressure measuring device, and (4) cardiovascular monitoring system. It was found, in experiments on dogs, that the pulse wave velocity is linearly related to diastolic blood pressure over a wide range of blood pressure and in the presence of many physiological perturbations. A similar relationship was observed in normal, young human males over a moderate range of pressures. Past methods for monitoring blood pressure and a new method based on pulse wave velocity determination were described. Two systems were tested: a Doppler ultrasonic transducer and a photoelectric plethysmograph. A cardiovascular monitoring system was described, including operating instructions.

Mark, R. G.↗

The importance of the renin-angiotensin system in normal cardiovascular homeostasis

Studies were carried out on adult mongrel dogs (20 to 30 kilograms) to investigate the importance of the renin-angiotensin system. Results indicate that the renin-angiotensin system plays a major role in the maintenance of circulatory homeostasis when extracellular fluid volume is depleted. It was also found that angiotensin II concentration, in addition to renal perfusion pressure, is a factor in the regulation of renin release.

Haber, E.↗

Uncoupling of the baroreflex by N(N)-cholinergic blockade in dissecting the components of cardiovascular regulation

Systemic administration of adrenergic agonists and nitric oxide donors is used extensively to determine cardiovascular receptor sensitivity. Conclusions regarding receptor sensitivity in the presence of the baroreflex may be misleading. In 8 normal volunteers, we determined the heart rate and blood pressure changes after incremental bolus doses of isoproterenol, phenylephrine, and sodium nitroprusside before and during neuronal nicotinic cholinergic (N(N)-cholinergic) blockade with trimethaphan. Results are given as median (25th/75th percentile). With trimethaphan, the baroreflex slope (as determined by bolus doses of nitroprusside and phenylephrine) decreased from 24 (22/26) to 0.00 (0.00/0.09) ms/mm Hg (P<0.01). The dose of isoproterenol that decreased systolic blood pressure (SBP) 12.5 mm Hg changed from 0.61 (0.51/5.3) to 0.17 (0.12/0.21) microg (P<0.01); the dose required to increase heart rate 12.5 bpm changed from 0.22 (0.17/0.41) to 0.74 (0.33/2.3) microg (P<0.01). The dose of nitroprusside required to decrease SBP 12.5 mm Hg changed from 2.3 (1.3/3.4) to 0.18 (0.14/0.24) microg/kg (P<0.01). The dose of phenylephrine required to increase SBP 12.5 mm Hg changed from 135 (110/200) to 16 (10/30) microg (P<0.01). We conclude that the efferent arc of the baroreflex can be completely interrupted with N(N)-cholinergic blockade. Estimation of adrenoreceptor sensitivity and sensitivity to nitric oxide donors by systemic administration of agonists is severely confounded by baroreflexes. Uncoupling of the baroreflex by N(N)-cholinergic blockade may be a useful method to obtain an integrated measure of adrenergic receptor sensitivity and sensitivity to nitric oxide donors in humans. This approach would permit the comparison of normal and abnormal physiological states without the "noise" of baroreflex buffering.

NASA Discipline Regulatory Physiology↗

Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mathematical models of physiological systems

Calcium/musculoskeletal, cardiovascular, erythropoieses, and fluid and electrolyte/renal regulation are discussed. Modeling and software development are also discussed.

White, R. J.↗

Efficacy of Female Rat Models in Translational Cardiovascular Aging Research

Cardiovascular disease is the leading cause of death in women in the United States. Aging is a primary risk factor for the development of cardiovascular disease as well as cardiovascular-related morbidity and mortality. Aging is a universal process that all humans undergo; however, research in aging is limited by cost and time constraints. Therefore, most research in aging has been done in primates and rodents; however it is unknown how well the effects of aging in rat models translate into humans. To compound the complication of aging gender has also been indicated as a risk factor for various cardiovascular diseases. This review addresses the systemic pathophysiology of the cardiovascular system associated with aging and gender for aging research with regard to the applicability of rat derived data for translational application to human aging.

59 BASIC BIOLOGICAL SCIENCES↗

Use of implantable telemetry systems for study of cardiovascular phenomena.

Preliminary observations of cardiovascular function have been made in four chimpanzees using multichannel implantable units. Measurements of right- and left-sided pressures were periodically made in these animals over a four-month period, including continuous observations for selected 24-hour periods. Pressures recorded with animals in an awake, unanesthetized, unrestrained state were much lower than pressures reported for restrained animals in similar situations. Diurnal variations of pressure tended to occur, but were not as clear-cut as those reported to occur for humans. The ability to implant a transmitter chronically and receive useful multichannel information in the chimpanzee encourages the future use of such implant devices as part of the control system for an artificial heart or directly for use in man.

Sandler, H.↗

Role of the anterior region of the third ventricle in the cardiovascular responses produced by systemic injection of a nitric oxide synthase inhibitor

This study examined whether a prior electrolytic lesion of the tissue surrounding the anteroventral third ventricle (AV3V) would affect the increase in mean arterial blood pressure (MAP) and the fall in heart rate (HR) produced by systemic injection of the nitric oxide synthesis (NOS) inhibitor, NG-nitro-L-arginine methyl ester (L-NAME; 25 micromol/kg, i.v.) in conscious rats. L-NAME produced a smaller increase in MAP in AV3V-lesion than in sham-lesion rats (+19+/-3 vs. +40+/-3 mmHg, respectively; P<0.05). In contrast, L-NAME produced similar falls in HR in the AV3V-lesion and sham-lesion rats (-103+/-15 vs. -97+/-8 bpm, respectively; P<0.05). These findings demonstrate that the L-NAME-induced pressor response is dependent upon the integrity of the AV3V region, whereas the L-NAME-induced bradycardia is not. Copyright 1999 Elsevier Science B. V.

Non-NASA Center↗