Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAPSULES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Design and testing of a boron carbide capsule for spectral-tailoring in mixed-spectrum reactors

A boron carbide capsule has been designed and used for spectral-tailoring experiments at the TRIGA reactor at Washington State Univ.. Irradiations were conducted in pulsed mode and in continuous operation for up to 4 h. A cadmium cover was used to reduce thermal heating. The neutron spectrum calculated with the Monte Carlo N-particle transport code was found to be in good agreement with reactor dosimetry measurements using the STAY'SL computer code. The neutron spectrum resembles that of a fast reactor. The design of a capsule using boron carbide fully enriched in {sup 10}B shows that it is possible to produce a neutron spectrum similar to that of {sup 235}U fission. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cs-135 Content of Cesium Capsules and Strontium/Cesium Heat Sources - 18509

The United States Department of Energy (DOE) is responsible for disposing of 1,335 cesium capsules and 34 strontium and cesium heat sources that are currently stored at the Hanford Site. The documented radionuclide inventories for these wastes report quantities of Sr-90 and Cs-137 but do not report quantities of other strontium and cesium isotopes, some of which need to be estimated for the purpose of conducting a postclosure performance assessment for the eventual disposal facility. The purpose of this paper is to present a method for estimating the quantity of Cs-135 present in the cesium capsules and in the strontium/cesium heat sources. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Safety and Efficacy of Oxycodone Versus Fentanyl in Percutaneous Microwave Ablation of a Liver Tumour Abutting the Capsule

Purpose: The present study compared the safety and efficacy of oxycodone with those of fentanyl under non-intubated general anaesthesia in percutaneous microwave ablation (MWA) of a liver tumour abutting the capsule. Materials and Methods: Thirty-eight patients underwent MWA of liver cancers abutting the capsule. Patients received 0.1 mg/kg oxycodone (O group) or 1 μg/kg fentanyl (F group) prior to the start of ablation. Both groups received continuous infusions of propofol for non-intubated general anaesthesia during ablation. The primary outcomes were the pain scores (11-point numeric rating scale, NRS) within 24 h after MWA. Vital signs, body movement during ablation, and opioid side effects after ablation were recorded. The need for additional analgesics was recorded 24 h after MWA. Results: The pain NRS scores were lower in the O group than in the F group at 0.5 (P = 0.035), 3 (P = 0.002), and 6 h (P = 0.001) after MWA, and fewer patients required additional analgesics in the O group (6 of 20 vs. 13 of 18, P = 0.022) within 24 h. The average 24-h dose of dezocine was 5.5 ± 4.1 mg in the F group and 2.1 ± 3.3 mg in the O group (P = 0.008). A significant reduction in the respiratory rate (P = 0.020) and more body movements were observed in the F group (P = 0.027) during ablation with non-intubated general anaesthesia. No differences in post-operative nausea and vomiting (PONV) were observed between the two groups, but dizziness occurred significantly more often in the O group (P = 0.033). No significant differences in other vital signs were observed before, during, and after the procedure. Conclusions: Oxycodone provides better analgesia and reduces post-operative opioid consumption without significant respiratory or hemodynamic instability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Eulerian Vlasov-Fokker–Planck algorithm for spherical implosion simulations of inertial confinement fusion capsules

Here, we present a numerical algorithm that enables a phase-space adaptive Eulerian Vlasov–Fokker–Planck (VFP) simulation of inertial confinement fusion (ICF) capsule implosions. The approach relies on extending a recent mass, momentum, and energy conserving phase-space moving-mesh adaptivity strategy to spherical geometry. In configuration space, we employ a mesh motion partial differential equation (MMPDE) strategy while, in velocity space, the mesh is expanded/contracted and shifted with the plasma’s evolving temperature and drift velocity. The mesh motion is dealt with by transforming the underlying VFP equations into a computational (logical) coordinate, with the resulting inertial terms carefully discretized to ensure conservation. To deal with the spatial and temporally varying dynamics in a spherically imploding system, we have developed a novel nonlinear stabilization strategy for MMPDE in the configuration space. The strategy relies on a nonlinear optimization procedure that optimizes between mesh quality and the volumetric rate change of the mesh to ensure both accuracy and stability of the solution. Implosions of ICF capsules are driven by several boundary conditions: (1) an elastic moving wall boundary; (2) a time-dependent Maxwellian Dirichlet boundary; and (3) a pressure-driven Lagrangian boundary. Of these, the pressure-driven Lagrangian boundary driver is new to our knowledge. The implementation of our strategy is verified through a set of test problems, including the Guderley and Van-Dyke implosion problems — the first-ever reported using a Vlasov–Fokker–Planck model.

1D2V↗

Demonstrating imaging plate detector stacks for proton radiography using exploding pusher capsules

A new detector design has been fielded on the Omega-60 laser facility using a D 3 He backlighter capsule to radiograph a magnetized experiment. D 3 He capsules produce a low flux (~ 10 8 total yield in 4π) of protons requiring detectors with close-to single-particle sensitivity to be employed. The new detector stack consisted of both imaging plate (IP) and CR-39 to detect 14.7 MeV protons where, historically, only CR-39 has been used. IP is sensitive to significant contributions in signal from both x-rays and protons so additional filtering has to be added to attenuate the x-rays. Here, the signals and features observed from a single shot are detected by both IP and CR-39, giving confirmation that it is protons creating the signatures on the IP. Measurements of PSL/pixel are used to calculate approximate on-shot proton yields and agree with commonly measured yields. A second IP is used at the rear of the stack to measure, and subsequently remove, a background signal. The spatial resolution at the IP is limited, primarily, by a range of proton energies with varying deflections being recorded at the detector, causing potential ‘blurring’ of features. We find for this setup that the blurring effect is less than the smallest identifiable features observed at the detector, and therefore of minimal impact. A large benefit to this new stack design is that IP can be scanned and processed on much faster timescales than CR-39 allowing for prompt shot feedback. Future designs and modifications to the stack design fielded on this experiment could help improve the contrast of the radiograph on IP, as well as detecting protons produced at alternative energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Critical processes and parameters in the development of accident tolerant fuels drop-in capsule irradiation tests

The goal of the Accident Tolerant Fuel (ATF) program is to develop the next generation of Light Water Reactor (LWR) fuels with improved performance, reliability, and safety characteristics during normal operations and accident conditions and with reduced waste generation. An irradiation test series has been defined to assess the performance of proposed ATF concepts under normal LWR operating conditions. The Phase I ATF irradiation test series is planned to be performed as a series of drop-in capsule tests to be irradiated in the Advanced Test Reactor (ATR) operated by the Idaho National Laboratory (INL). Design, analysis, and fabrication processes for ATR drop-in capsule experiment preparation are presented in this paper to demonstrate the importance of special design considerations, parameter sensitivity analysis, and precise fabrication and inspection techniques for figure innovative materials used in ATF experiment assemblies. A Taylor Series Method sensitivity analysis approach was used to identify the most critical variables in cladding and rodlet stress, temperature, and pressure calculations for design analyses. The results showed that internal rodlet pressure calculations are most sensitive to the fission gas release rate uncertainty while temperature calculations are most sensitive to cladding I.D. and O.D. dimensional uncertainty. The analysis showed that stress calculations are most sensitive to rodlet internal pressure uncertainties, however the results also indicated that the inside radius, outside radius, and internal pressure were all magnified as they propagate through the stress equation. This study demonstrates the importance for ATF concept development teams to provide the fabricators as much information as possible about the material properties and behavior observed in prototype testing, mock-up fabrication and assembly, and chemical and mechanical testing of the materials that may have been performed in the concept development phase. Special handling, machining, welding, and inspection of materials, if known, should also be communicated to the experiment fabrication and inspection team.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Irradiation of an enriched uranium (NaCl-UCl 3 ) fuel salt capsule, summary of nondestructive post-irradiation examinations, and solidification modeling

Molten salt reactors (MSRs) are gaining attention due to their potential for safe, carbon-free nuclear energy with reduced waste. However, licensing these reactors is hindered by limited experimental data on fueled salts, both pre- and post-irradiation. Here, the novel Molten-salt Research Temperature-controlled Irradiation (MRTI) vehicle was designed to address knowledge gaps in irradiating enriched‑uranium-bearing salts. The MRTI experiment irradiated 13 cm 3 of UCl₃-NaCl (93 % U-235) salt in the Neutron Radiography (NRAD) Reactor, achieving a burnup of 0.196 GWd/MTU over 390 h. Despite a heater failure, the thermocouple data suggested fission heat kept the salt molten. The MRTI assembly was remotely disassembled for nondestructive post-irradiation examination (PIE), which included precision gamma-ray scanning (PGS) and neutron radiography. Radiograph images showed the location of the salt and the solidification pattern. PGS results provided an early indication that activated materials of construction did not increase in relative intensity in the region of the capsule where the salt was in contact with the material of construction. Additionally, PGS data showed the presence of several gamma emitting fission products, such as Nb-95, Zr-95, Ru-103, Ce-141, and La-140, where Ru-103 had the highest counts at the bottom of the capsule. Computational fluid dynamics modeling supported observations of salt solidification patterns and proved to be a valuable tool to inform PIE activities. The MRTI experiment has thus far provided critical data and lessons learned for fuel salt PIE activities, essential for advancing the technical readiness of MSRs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGTR1 blocker attenuates activation of Tenon's capsule fibroblasts after glaucoma filtration surgery via the NF-κB signaling pathway

Activation of Tenon's capsule fibroblasts limits the success rate of glaucoma filtration surgery (GFS), the most efficacious therapy for patients with glaucoma. Angiotensin type 1 receptor (AGTR1) is involved in tissues remodeling and fibrogenesis. However, whether AGTR1 is involved in the progress of fibrogenesis after GFS is not fully elucidated. The aim of this study was to investigate the role of an AGTR1 in scar formation after GFS and the potential anti-fibrosis effect of AGTR1 blocker. AGTR1 expression level was increased in subconjunctival tissues in a rat model of GFS and transforming growth factor-beta 2 (TGF-β2)-induced human Tenon's capsule fibroblasts (HTFs). AGTR1 blocker treatment suppressed TGF-β2-induced HTF migration and α-smooth muscle actin (α-SMA) and fibronectin (FN) expression. AGTR1 blocker treatment also attenuated collagen deposition and α-SMA and FN expression in subconjunctival tissues of the rat model after GFS. Moreover, AGTR1 blocker decreased TGF-β2-induced P65 phosphorylation, P65 nuclear translocation, and nuclear factor kappa B (NF-κB) luciferase activity. Additionally, BAY 11–7082 (an NF-κB inhibitor) significantly suppressed HTF fibrosis. In conclusion, our results indicate that AGTR1 is involved in scar formation after GFS. The AGTR1 blocker attenuates subconjunctival fibrosis after GFS by inhibiting the NF-κB signaling pathway. These findings indicate that targeting AGTR1 is a potential approach to attenuate fibrosis after GFS.

60 APPLIED LIFE SCIENCES↗

Sulfate Separation from Aqueous Alkaline Solutions by Selective Crystallization of Alkali Metal Coordination Capsules

Self-assembly of a tris(urea) anion receptor with Na{sub 2}SO{sub 4} or K{sub 2}SO{sub 4} yields crystalline capsules held together by coordinating Na{sup +} or K{sup +} cations and hydrogen-bonding water bridges, with the sulfate anions encapsulated inside urea-lined cavities. The sodium-based capsules can be selectively crystallized in excellent yield from highly competitive aqueous alkaline solutions ({approx}6 M Na{sup +}, pH 14), thereby providing for the first time a viable approach to sulfate separation from nuclear wastes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Urea-functionalized crystalline capsules for recognition and separation of tetrahedral oxoanions

We reviewed the persistent ability of tripodal TREN-based tris-urea receptors (TREN = tris(2-aminoethyl)amine) to self-assemble with a variety of oxoanions into dimeric capsules upon crystallization. The capsule crystallization allows for charge-, shape-, and size-selective encapsulation of tetrahedral XO 4 n- anions (n = 2,3), and provides an effective way to separate these anions from competitive aqueous environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spallation as a dominant source of pusher-fuel and hot-spot mix in inertial confinement fusion capsules

We suggest that a potentially dominant but previously neglected source of pusher-fuel and hot-spot “mix” may have been the main degradation mechanism for fusion energy yields of modern inertial confinement fusion (ICF) capsules designed and fielded to achieve high yields — not hydrodynamic instabilities. This potentially dominant mix source is the spallation of small chunks or “grains” of pusher material into the fuel regions whenever (1) the solid material adjacent to the fuel changes its phase by nucleation, and (2) this solid material spalls under shock loading and sudden decompression. Finally, we describe this mix mechanism, support it with simulations and experimental evidence, and explain how to eliminate it and thereby allow higher yields for ICF capsules and possibly ignition at the National Ignition Facility.

42 ENGINEERING↗

Simulation and assessment of ion kinetic effects in a direct-drive capsule implosion experiment

The first simulations employing a kinetic treatment of both fuel and shell ions to model inertial confinement fusion experiments are presented, including results showing the importance of kinetic physics processes in altering fusion burn. A pair of direct drive capsule implosions performed at the OMEGA facility with two different gas fills of deuterium, tritium, and helium-3 are analyzed. During implosion shock convergence, highly non-Maxwellian ion velocity distributions and separations in the density and temperature amongst the ion species are observed. Finally, diffusion of fuel into the capsule shell is identified as a principal process that degrades fusion burn performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Capsule physics comparison of National Ignition Facility implosion designs using plastic, high density carbon, and beryllium ablators

Indirect drive implosion experiments on the National Ignition Facility (NIF) [E. I. Moses et al., Phys. Plasmas 16, 041006 (2009)] have now tested three different ablator materials: glow discharge polymer plastic, high density carbon, and beryllium. How do these different ablators compare in current and proposed implosion experiments on NIF? What are the relative advantages and disadvantages of each? This paper compares these different ablator options in capsule-only simulations of current NIF experiments and potential future designs. The simulations compare the impact of the capsule fill tube, support tent, and interface surface roughness for each case, as well as all perturbations in combination. According to the simulations, each ablator is impacted by the various perturbation sources differently, and each material poses unique challenges in the pursuit of ignition on NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using time-resolved penumbral imaging to measure low hot spot x-ray emission signals from capsule implosions at the National Ignition Facility

Here, we have developed and fielded a new x-ray pinhole-imaging snout that exploits time-resolved penumbral imaging of low-emission hot spots in capsule implosion experiments at the National Ignition Facility (NIF). We report on results for a series of indirectly driven Be capsule implosions that aim at measuring x-ray Thomson scattering (XRTS) spectra at extreme density conditions near stagnation. In these implosions, x-ray emission at stagnation is reduced by 100 – 1000x compared to standard inertial confinement fusion (ICF) implosions to mitigate undesired continuum background in the XRTS spectra. Our snout design enables not only measurements of peak x-ray emission times, t o , where standard ICF diagnostics would not record any signal, but also allows for inference of hot spots shapes. Measurement of t o is crucial to account for shot-to-shot variations in implosion velocity and therefore to benchmark the achieved plasma conditions between shots and against radiation hydrodynamics simulations. Additionally, we used differential filtering to infer a hot spot temperature of 520 ± 80 eV, which is in good agreement with predictions from radiation hydrodynamic simulations. Here, we find that, despite fluctuations of the x-ray flash intensity of up to 5x, the emission time history is similar from shot to shot, and slightly asymmetric with respect to peak x-ray emission.

47 OTHER INSTRUMENTATION↗

Stable and confined burn in a Revolver ignition capsule

In this paper, the main burn phase physics in a Revolver ignition capsule is analyzed and found to exhibit a new feature where pusher stagnation is persistent and burn occurs with the fuel at a fixed volume. The pressure and density gradients at the fuel-pusher interface are both positive making it stable to Rayleigh-Taylor growth. Expansion cooling and RT mixing are absent from the Revolver burn during this time. The effect is due to the massive heavy metal pusher shell being compressed during implosion and heated on an inner layer by the Marshak wave. The pusher is driven to a higher pressure than the DT fuel and becomes a fuel confining shell starting at stagnation and continuing past the time of peak burn. This period of persistent stagnation lasts for approximately 100 ps (in the baseline design) with a fuel burnup during stagnation of 40%. Finally, this behavior does not occur in any other capsule designs, including the double shell schemes that also employ a heavy metal pusher.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrodynamic instabilities seeded by the X-ray shadow of ICF capsule fill-tubes [X-ray shadow imprint of hydrodynamic instabilities seeded by the fill-tube]

During the first few hundred picoseconds of indirect drive for inertial confinement fusion on the National Ignition Facility, x-ray spots formed on the hohlraum wall when the drive beams cast shadows of the fuel fill-tube on the capsule surface. Differential ablation at the shadow boundaries seeds perturbations which are hydrodynamically unstable under subsequent acceleration and can grow to impact capsule performance. Furthermore, we have characterized this shadow imprint mechanism and demonstrated two techniques to mitigate against it using (i) a reduced diameter fuel fill-tube, and (ii) a pre-pulse to blow down the fill-tube before the shadow forming x-ray spots from the main outer drive beams develop.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First demonstration of improved capsule implosions by reducing radiation preheat in uranium vs gold hohlraums

In indirectly-driven Inertial Confinement Fusion (ICF) implosions, supra-thermal M-band (>2 keV) radiation from principally 4–3 resonance line transitions generated during laser irradiation at the peak power of Au hohlraum walls can preheat the fusion capsule and reduce compressional pressure. Higher Z, un-lined depleted uranium (DU) hohlraums were used for the first time in ICF implosions on the National Ignition Facility (NIF) to reduce M-band radiation levels while keeping the total radiation flux similar to Au hohlraums. First implosions in DU demonstrate an increase in in-flight density (+15%) of high density carbon capsules, and hence in stagnated hot spot temperature (+15%), hot spot x-ray (+200%) and fusion neutron yields (+100%) compared to Au hohlraums. We show analytically that these changes are consistent with the observed 40% reduction in M-band x-ray flux in DU, and are in agreement with 2D hydrodynamic simulations. This result had a major impact on ICF research on the NIF where a significant fraction of high neutron yield implosions are currently using un-lined DU hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of areal-density asymmetries on the loss of confinement and ignition threshold in inertial confinement fusion capsules

In inertial confinement fusion implosion experiments, variations in the shell areal density reduce the shell’s inertia to confine the core pressure. Distorted capsules with large areal-density modulations decompress faster than uniform capsules in the disassembly phase. A simple 3-D analytic hot-spot model is derived to include the effects of low-mode areal-density modulations in the ignition criterion. The generalized 3-D ignition criterion for low modes is shown to depend on both the harmonic mean and the arithmetic mean of the areal density. Here, the “thin spots” in the shell are shown to dominate the loss of confinement as reflected by the harmonic mean definition of areal densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗