Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

TU-G-201-03: Imaging Systems in Radiotherapy: Buying, Installing, and Using

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

Miniature Time-of-Flight Mass Spectrometer

Major advances must occur to protect astronauts from prolonged periods in near-zero gravity and high radiation associated with extended space travel. The dangers of living in space must be thoroughly understood and methods developed to reverse those effects that cannot be avoided. Six of the seven research teams established by the National Space Biomedical Research Institute (NSBRI) are studying biomedical factors for prolonged space travel to deliver effective countermeasures. To develop effective countermeasures, each of these teams require identification of and quantitation of complex pharmacological, hormonal, and growth factor compounds (biomarkers) in humans and in experimental animals to develop an in-depth knowledge of the physiological changes associated with space travel. At present, identification of each biomarker requires a separate protocol. Many of these procedures are complicated and the identification of each biomarker requires a separate protocol and associated laboratory equipment. To carry all of this equipment and chemicals on a spacecraft would require a complex clinical laboratory; and it would occupy much of the astronauts time. What is needed is a small, efficient, broadband medical diagnostic instrument to rapidly identify important biomarkers for human space exploration. The Miniature Time-Of- Flight Mass Spectrometer Project in the Technology Development Team is developing a small, high resolution, time-of-flight mass spectrometer (TOFMS) to quantitatively measure biomarkers for human space exploration. Virtues of the JHU/APL TOFMS technologies reside in the promise for a small (less than one cubic ft), lightweight (less than 5 kg), low-power (less than 50 watts), rugged device that can be used continuously with advanced signal processing diagnostics. To date, the JHU/APL program has demonstrated mass capability from under 100 to beyond 10,000 atomic mass units (amu) in a very small, low power prototype for biological analysis. Further, the electronic nature of the TOFMS output makes it ideal for rapid telemetry to earth for in-depth analysis by ground support teams.

Potember, Richard S.↗

Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction

Background: The benefits of attenuation correction (AC) in technetium-99m myocardial perfusion imaging (MPI) have been well established. However, the value of thallium (Tl-201) AC and routine computed tomography AC (CTAC) were less well established. The aims of this study were to evaluate the diagnostic performance of thallium (Tl-201) MPI with additional CTAC and to determine which participants would benefit most. Methods and Results: A total of 108 consecutive patients who underwent Tl-201 MPI and received coronary angiography within 3 months were enrolled. Diagnostic performance was determined by sensitivity, specificity, and receiver operating characteristic curve analysis. Subgroup analyses were performed using gender and obesity. CTAC improved the area under the curve (0.84 vs. 0.77, P = 0.037 at patient level), primarily due to a significant improvement in specificity (0.78 vs. 0.57, P = 0.013) and no significant difference in sensitivity (0.79 vs. 0.82, P = 0.75). In subgroup analysis, CTAC was most helpful in obese subjects, men, and especially right coronary artery lesions. Conclusions: CTAC significantly improved diagnostic performance primarily by increasing the specificity, and the improvements were significantly greater in obese patients and male patients. These findings suggest that CTAC should be applied to Tl-201 MPI as routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

BI-RADS 3: Current and Future Use of Probably Benign

Purpose of Review: Probably benign (BI-RADS 3) causes confusion for interpreting physicians and referring physicians and can induce significant patient anxiety. The best uses and evidence for using this assessment category in mammography, breast ultrasound, and breast MRI will be reviewed; the reader will have a better understanding of how and when to use BI-RADS 3. Recent Findings: Interobserver variability in the use of BI-RADS 3 has been documented. The 5th edition of the BI-RADS atlas details the appropriate use of BI-RADS 3 for diagnostic mammography, ultrasound, and MRI, and discourages its use in screening mammography. Data mining, elastography, and diffusion weighted MRI have been evaluated to maximize the accuracy of BI-RADS 3. Summary: BI-RADS 3 is an evolving assessment category. When used properly, it reduces the number of benign biopsies while allowing the breast imager to maintain a high sensitivity for the detection of early stage breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Evaluation of Image Acquisition Techniques, Radiographic Practice, and Technical Quality in Neonatal Chest Radiography

Neonatal chest radiography is a frequently performed diagnostic examination, particularly in preterm infants where anatomical and/or biochemical immaturity impacts on respiratory function. However, the quality of neonatal radiographic images has been criticized internationally and a prevailing concern has been that radiographers (radiologic technologists) fail to appreciate the unique nature of neonatal and infant anatomical proportions. The aim of this study was to undertake a retrospective evaluation of neonatal chest radiography image acquisition techniques against key technical criteria.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-248: Contributions of Tumor and Stroma Phenotyping in Computer-Aided Diagnosis

Purpose: To gain insight into the role of parenchyma stroma in the characterization of breast tumors by incorporating computerized mammographic parenchyma assessment into breast CADx in the task of distinguishing between malignant and benign lesions. Methods: This study was performed on 182 biopsy-proven breast mass lesions, including 76 benign and 106 malignant lesions. For each full-field digital mammogram (FFDM) case, our quantitative imaging analysis was performed on both the tumor and a region-of-interest (ROI) from the normal contralateral breast. The lesion characterization includes automatic lesion segmentation and feature extraction. Radiographic texture analysis (RTA) was applied on the normal ROIs to assess the mammographic parenchymal patterns of these contralateral normal breasts. Classification performance of both individual computer extracted features and the output from a Bayesian artificial neural network (BANN) were evaluated with a leave-one-lesion-out method using receiver operating characteristic (ROC) analysis with area under the curve (AUC) as the figure of merit. Results: Lesion characterization included computer-extracted phenotypes of spiculation, size, shape, and margin. For parenchymal pattern characterization, five texture features were selected, including power law beta, contrast, and edge gradient. Merging of these computer-selected features using BANN classifiers yielded AUC values of 0.79 (SE=0.03) and 0.67 (SE=0.04) in the task of distinguishing between malignant and benign lesions using only tumor phenotypes and texture features from the contralateral breasts, respectively. Incorporation of tumor phenotypes with parenchyma texture features into the BANN yielded improved classification performance with an AUC value of 0.83 (SE=0.03) in the task of differentiating malignant from benign lesions. Conclusion: Combining computerized tumor and parenchyma phenotyping was found to significantly improve breast cancer diagnostic accuracy highlighting the need to consider both tumor and stroma in decision making. Funding: University of Chicago Dean Bridge Fund, NCI U24-CA143848-05, P50-CA58223 Breast SPORE program, and Breast Cancer Research Foundation. COI: MLG is a stockholder in R2 technology/Hologic and receives royalties from Hologic, GE Medical Systems, MEDIAN Technologies, Riverain Medical, Mitsubishi, and Toshiba. MLG is a cofounder and stockholder in Quantitative Insights.

60 APPLIED LIFE SCIENCES↗

Theranostic Radiopnictogens: 71 As, 72 As, and 119 Sb (Final Technical Report)

This project has developed new methods for the cyclotron production of medically relevant radionuclides 71 As and 119 Sb. Arsenic and antimony are chemically homologous elements (group 5A, also known as the pnictogens) that have radionuclides that are of considerable interest within nuclear medicine. Such radiopnictogens include the potentially therapeutic radionuclides 119 Sb (t 1/2 = 38 h) that decays with the emission of 24.5 low energy, high potency electrons per decay with little concomitant photon radiation and 77 As (t 1/2 = 39 h) that decays with average beta energy of 230 keV and diagnostic nuclides 71 As (t 1/2 = 65 h, 28% β+) and 72 As (t 1/2 = 26 h, 80% β+) for positron emission tomography (PET). This work has had major success developing new methods for the cyclotron production and radiochemical isolation of 71 As, supporting parallel developments for 119 Sb, and assessing the chemical similarities between these two homologous radionuclides. This project brought into collaboration two universities with complimentary skill sets, proficiencies, expertise, and facilities: the University of Wisconsin (UWisc) and the University of Missouri (Mizzou). Professors Ellison and Engle have experience in the small cyclotron production and radiochemical isolation of radionuclides, including 72 As and 119 Sb. Their recently developed metallurgic methods for fabricating cyclotron targets have great potential to expand and allow for the biomedical cyclotron production of long- lived, lower positron energy 71 As. Professors Hennkens and Jurisson have significant experience in the reactor production, radiochemical isolation, and biological functionalization of radioarsenic. Recent development of trithiol-based chelator molecules for functionalizing radioarsenic provide a platform for the investigation of the fundamental challenges of the promising low-energy-electron emitter, 119 Sb. Through their positions within their respective University’s graduate schools, the PIs and Co-Is effectively trained of graduate students and postdoctoral researchers in nuclear and radiochemistry, sub-specialties specifically identified in the Department of Energy (DOE) Office of Science Isotope Program long-range plan. Annual laboratory research visits for students between UWisc and Mizzou provided essential broad-field experience and scientific networking that is critical for maintaining their path along the training pipeline to productive careers in isotope production. This research collaboration has provided significant benefits to the DOE University Isotope Network and radionuclide-using researchers around the country.

07 ISOTOPE AND RADIATION SOURCES↗

Dual-Energy CT Pulmonary Angiography: Quantification of Disease Burden and Impact on Management

Purpose of Review: Computed tomography pulmonary angiography (CTPA) has become the imaging modality of choice for patients with suspected pulmonary embolism (PE). Post-processing techniques currently available for dual-energy CT pulmonary angiography (DE-CTPA) enhance image quality and provide additional value in the diagnosis of PE. The objective of this article is to summarize these recent developments and discuss the appropriate use of DE-CTPA post-processing applications. Recent Findings: DE-CTPA post-processing applications enable reconstruction of virtual monoenergetic images (VMI) and color-coded iodine-perfusion maps to increase contrast conditions and visualize lung perfusion defects in case of embolic occlusion of pulmonary arteries. Both techniques revealed a superior diagnostic performance for the detection of pulmonary emboli and assessment of the pulmonary perfusion compared to the standard image reconstructions. Summary: DE-CTPA is a well-established method for excluding or diagnosing PE. Continued developments in DE-CTPA post-processing techniques improve patient management and allow for a quantification of disease burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Rotational Angiography of the Foot in Critical Limb Ischemia: A New Dimension in Revascularization Strategy

Purpose. To evaluate the additional value of three-dimensional rotational angiography (3DRA) of the foot compared with digital subtraction angiography (DSA) in patients with critical limb ischemia (CLI). Technique. For 3DRA, the C-arm was placed in the propeller position with the foot in an isocentric position. The patient's unaffected foot was positioned in a footrest outside the field of view. For correct timing of 3DRA, the delay from contrast injection in the popliteal artery at the level of knee joint to complete pedal arterial enhancement was assessed using DSA. With this delay, 3DRA was started after injection of 15 ml contrast. Imaging of the 3DRA could directly be reconstructed and visualized.Materials and MethodsPatients undergoing 3DRA of the foot were prospectively registered. DSA and 3DRA images were scored separately for arterial patency and presence of collaterals. Treatment strategies were proposed based on DSA with and without the availability of 3DRA. Results. Eleven patients underwent 3DRA of the foot. One 3DRA was not included because the acquisition was focused on the heel instead of the entire foot. Diagnostic quality of 3DRA was good in all ten patients. 3DRA compared with DSA showed additional patent arteries in six patients, patent plantar arch in three patients, and collaterals between the pedal arteries in five patients. Additional information from 3DRA resulted in a change of treatment strategy in six patients. Conclusion, 3DRA of the foot contains valuable additional real-time information to better guide peripheral vascular interventions in patients with CLI and nonhealing tissue lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Children, medical radiation and the environment: An important dialogue

There are unique considerations in the medical care of children, which includes the use of medical imaging. Medical imaging is frequently necessary and is essential in diagnosis and management of children with illness and injury. Much of medical imaging requires ionizing radiation. While virtually all diagnostic imaging radiation is considered low-dose level, there is still a broad misperception about what modalities use ionizing radiation and how much radiation risk exists in the medical environment. A discussion of radiation exposure is especially relevant in children due to their increased vulnerability, including to radiation-induced cancer. Ionizing radiation is both naturally occurring and man-made, including medical sources that have been increasing over the past few decades and can vary in radiation dose both between different modalities and for similar examinations. Perspectives vary regarding cancer risk and levels of radiation resulting from diagnostic imaging, however most medical and scientific organization support the perspective that the risk of cancer at these levels is uncertain. It is important to have balanced and informed resources for the use of ionizing radiation in the care of children, and it is equally important to assure that the delivery of this content is appropriate to the audience to which it is intended. For these reasons, it is valuable to review the issues related to use of ionizing radiation in medical imaging in children.

54 ENVIRONMENTAL SCIENCES↗

MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and patient alignment. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

Advanced Diagnostic and Sample Preparation Platform for Early Threat Surveillance

Emerging infectious diseases present a profound threat to global health, economic development, and political stability, and therefore represent a significant national security concern for the United States. The increased prevalence of international travel and globalized trade further amplify the threat of infectious disease outbreaks of catastrophic effect. The key to containing and eradicating an outbreak before it goes global is rapid identification of index cases and initial clusters of affected individuals. This depends upon establishment of a biosurveillance network that effectively reaches infectious disease hotspots in even the most remote regions of the world and provides a network-integrated, location-appropriate diagnostic capability. At present, there are two critical needs which must be addressed in order to extend biosurveillance activities beyond centralized laboratory facilities: 1) A simple, reliable, and safe method for immediate stabilization of clinical specimens in the field; and 2) A flexible sample processing platform that enables in-field preparation of clinical specimens for rapid, on-site analysis using a variety of diagnostic assay platforms. These needs are not necessarily mutually exclusive; in fact, we propose that they are most efficiently addressed by a deployable sample processing platform that immediately stabilizes the information content of clinical specimens through transformation of the inherently unstable analytes of interest into stable equivalents that are appropriately formatted for downstream analysis. In order to address this problem, we have developed a sample processing pipeline and microfluidics-based platform modules enabling: 1) Extraction of total RNA from finger-stick quantities of human whole blood; and 2) Microscale synthesis of appropriately-formatted cDNA products that capture the information content of blood RNA in a stable form that supports pathogen detection and/or characterization via PCR and/or Second Generation Sequencing (SGS). Through this research we have discovered new, effective solutions for problems that thus far have hindered use of digital microfluidics (DMF) in biomedical applications. Our work reveals a clear path forward to fieldable, automated sample processing systems that will enable rapid, on-site identification of usual-suspect and novel pathogens in clinical specimens for improved biosurveillance.

59 BASIC BIOLOGICAL SCIENCES↗

Physiological adaptation to space flight

In space, adaptive physiological changes have been observed in virtually all body systems, but how far these changes progress with time is not known. Their time course demonstrates variable patterns; some systems show evidence of gradual and progressive change. Biomedical postflight data have shown that a compensatory period of readaptation to one gravity is required after space flight, with longer intervals required for longer missions. Consistent readaptation trends include orthostatic intolerance and neurovestibular difficulties. For the long-duration missions of the exploration era, it is critical to determine the extent to which deleterious changes (e.g., bone loss and possible immunological changes) can be reversed upon return to earth. Radiation protection is another critical enabling element for missions beyond low earth orbit. Radiation exposure guidelines have not been established for exploration missions. Currently our experience is insufficient to prescribe countermeasures for the stay times associated with a lunar base or a mission to Mars. Artificial gravity may provide a solution, but the level and duration of exposure necessary to prevent deconditioning must be determined. Central issues for medical care in remote settings are preventive, diagnostic, and therapeutic care and the minimization of risk.

Nicogossian, Arnauld E.↗

Compact Microscope Imaging System Developed

The Compact Microscope Imaging System (CMIS) is a diagnostic tool with intelligent controls for use in space, industrial, medical, and security applications. The CMIS can be used in situ with a minimum amount of user intervention. This system, which was developed at the NASA Glenn Research Center, can scan, find areas of interest, focus, and acquire images automatically. Large numbers of multiple cell experiments require microscopy for in situ observations; this is only feasible with compact microscope systems. CMIS is a miniature machine vision system that combines intelligent image processing with remote control capabilities. The software also has a user-friendly interface that can be used independently of the hardware for post-experiment analysis. CMIS has potential commercial uses in the automated online inspection of precision parts, medical imaging, security industry (examination of currency in automated teller machines and fingerprint identification in secure entry locks), environmental industry (automated examination of soil/water samples), biomedical field (automated blood/cell analysis), and microscopy community. CMIS will improve research in several ways: It will expand the capabilities of MSD experiments utilizing microscope technology. It may be used in lunar and Martian experiments (Rover Robot). Because of its reduced size, it will enable experiments that were not feasible previously. It may be incorporated into existing shuttle orbiter and space station experiments, including glove-box-sized experiments as well as ground-based experiments.

McDowell, Mark↗

Breast Imaging of Transgender Individuals: A Review

Purpose: This review will inform radiologists about the evidence base regarding radiographic imaging for transgender individuals and considerations for providing culturally sensitive care for this population. Findings: Transgender individuals are increasingly referred for both screening and diagnostic breast imaging. It is important that the clinic environment is welcoming, the medical staff utilize accepted terminology and patients are able to designate their gender and personal history to ensure appropriate care. Hormone and surgical treatments used for transition by many transgender women and men may change the approach to imaging. Summary: Although not yet evidence-based, screening mammography is currently suggested for transgender women with risk factors, including those receiving hormone treatment over 5 years. The risk for breast cancer in transgender individuals is still being defined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-209-00: Identifying Image Artifacts, Their Causes, and How to Fix Them

Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

60 APPLIED LIFE SCIENCES↗

Imaging the Breast in Pregnant or Lactating Women

Purpose of Review: To describe the imaging evaluation of common benign and malignant breast lesions encountered in pregnant or lactating women. Recent Findings: There is increasing prevalence of pregnancy-associated breast cancer as the age of women during pregnancy increases. Women in the first 10 years following pregnancy demonstrate an elevated risk for breast cancer compared to the average population. MRI has been shown to be more sensitive for evaluating the extent of disease in lactating patients than mammography or ultrasound. Summary: The hormonal effects of pregnancy and lactation on the breast lead to distinct physiologic changes and pathologic lesions, which can manifest in unique imaging appearances. Most patients will undergo ultrasound for primary diagnostic evaluation. While mammography is not routinely utilized, it is not contraindicated even in pregnancy given the negligible radiation dose to the fetus. While most detected lesions are benign, pregnancy-associated breast cancer (PABC) is a rare diagnosis that must always be excluded. Women with PABC have a worse prognosis than age-matched controls partly due to delay in diagnosis. Thus prompt and accurate work-up of PABC is critical to improve outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗