Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bad data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Isoliquiritigenin induces growth inhibition and apoptosis through downregulating arachidonic acid metabolic network and the deactivation of PI3K/Akt in human breast cancer

Arachidonic acid (AA)-derived eicosanoids and its downstream pathways have been demonstrated to play crucial roles in growth control of breast cancer. Here, we demonstrate that isoliquiritigenin, a flavonoid phytoestrogen from licorice, induces growth inhibition and apoptosis through downregulating multiple key enzymes in AA metabolic network and the deactivation of PI3K/Akt in human breast cancer. Isoliquiritigenin diminished cell viability, 5-bromo-2′-deoxyuridine (BrdU) incorporation, and clonogenic ability in both MCF-7 and MDA-MB-231cells, and induced apoptosis as evidenced by an analysis of cytoplasmic histone-associated DNA fragmentation, flow cytometry and hoechst staining. Furthermore, isoliquiritigenin inhibited mRNA expression of multiple forms of AA-metabolizing enzymes, including phospholipase A2 (PLA2), cyclooxygenases (COX)-2 and cytochrome P450 (CYP) 4A, and decreased secretion of their products, including prostaglandin E{sub 2} (PGE{sub 2}) and 20-hydroxyeicosatetraenoic acid (20-HETE), without affecting COX-1, 5-lipoxygenase (5-LOX), 5-lipoxygenase activating protein (FLAP), and leukotriene B{sub 4} (LTB{sub 4}). In addition, it downregulated the levels of phospho-PI3K, phospho-PDK (Ser{sup 241}), phospho-Akt (Thr{sup 308}), phospho-Bad (Ser{sup 136}), and Bcl-x{sub L} expression, thereby activating caspase cascades and eventually cleaving poly(ADP-ribose) polymerase (PARP). Conversely, the addition of exogenous eicosanoids, including PGE{sub 2}, LTB{sub 4} and a 20-HETE analog (WIT003), and caspase inhibitors, or overexpression of constitutively active Akt reversed isoliquiritigenin-induced apoptosis. Notably, isoliquiritigenin induced growth inhibition and apoptosis of MDA-MB-231 human breast cancer xenografts in nude mice, together with decreased intratumoral levels of eicosanoids and phospho-Akt (Thr{sup 308}). Collectively, these data suggest that isoliquiritigenin induces growth inhibition and apoptosis through downregulating AA metabolic network and the deactivation of PI3K/Akt in human breast cancer. - Highlights: • Isoliquiritigenin induces growth inhibition and apoptosis in human breast cancer. • The proapoptotic action of isoliquiritigenin has been studied in vitro and in vivo. • Arachidonic acid metabolic network mediates isoliquiritigenin-induced apoptosis. • PI3K/Akt deactivation is asssociated with isoliquiritigenin-induced apoptosis. • Isoliquiritigenin may be a multi-target drug in the treatment of breast cancer.

60 APPLIED LIFE SCIENCES↗

Shuttle Repair Tools Automate Vehicle Maintenance

Successfully building, flying, and maintaining the space shuttles was an immensely complex job that required a high level of detailed, precise engineering. After each shuttle landed, it entered a maintenance, repair, and overhaul (MRO) phase. Each system was thoroughly checked and tested, and worn or damaged parts replaced, before the shuttle was rolled out for its next mission. During the MRO period, workers needed to record exactly what needed replacing and why, as well as follow precise guidelines and procedures in making their repairs. That meant traceability, and with it lots of paperwork. In 2007, the number of reports generated during electrical system repairs was getting out of hand-placing among the top three systems in terms of paperwork volume. Repair specialists at Kennedy Space Center were unhappy spending so much time at a desk and so little time actually working on the shuttle. "Engineers weren't spending their time doing technical work," says Joseph Schuh, an electrical engineer at Kennedy. "Instead, they were busy with repetitive, time-consuming processes that, while important in their own right, provided a low return on time invested." The strain of such inefficiency was bad enough that slow electrical repairs jeopardized rollout on several occasions. Knowing there had to be a way to streamline operations, Kennedy asked Martin Belson, a project manager with 30 years experience as an aerospace contractor, to co-lead a team in developing software that would reduce the effort required to document shuttle repairs. The result was System Maintenance Automated Repair Tasks (SMART) software. SMART is a tool for aggregating and applying information on every aspect of repairs, from procedures and instructions to a vehicle s troubleshooting history. Drawing on that data, SMART largely automates the processes of generating repair instructions and post-repair paperwork. In the case of the space shuttle, this meant that SMART had 30 years worth of operations that it could apply to ongoing maintenance work. According to Schuh, "SMART standardized and streamlined many shuttle repair processes, saving time and money while increasing safety and the quality of repairs." Maintenance technicians and engineers now had a tool that kept them in the field, and because SMART is capable of continually evolving, each time an engineer put it to use, it would enrich the Agency-wide knowledge base. "If an engineer sees something in the work environment that they could improve, a repair process or a procedure, SMART can incorporate that data for use in future operations," says Belson.

Source record↗

A Probabilistic Software System Attribute Acceptance Paradigm for COTS Software Evaluation

Standard software requirement formats are written from top-down perspectives only, that is, from an ideal notion of a client s needs. Despite the exactness of the standard format, software and system errors in designed systems have abounded. Bad and inadequate requirements have resulted in cost overruns, schedule slips and lost profitability. Commercial off-the-shelf (COTS) software components are even more troublesome than designed systems because they are often provided as is and subsequently delivered with unsubstantiated validation of described capabilities. For COTS software, there needs to be a way to express the client s software needs in a consistent and formal manner using software system attributes derived from software quality standards. Additionally, the format needs to be amenable to software evaluation processes that integrate observable evidence garnered from historical data. This paper presents a paradigm that effectively bridges the gap between what a client desires (top-down) and what has been demonstrated (bottom-up) for COTS software evaluation. The paradigm addresses the specification of needs before the software evaluation is performed and can be used to increase the shared understanding between clients and software evaluators about what is required and what is technically possible.

Morris, A. Terry↗

MISR Level 2 TOA/Cloud Stereo parameters (MIL2TCST_V2)

The MISR Top-of-Atmosphere (TOA)/Cloud Stereo geophysical parameters include stereoscopically-derived cloud motion vectors (winds), cloud-top heights, and an accompanying cloud mask. The Stereo product geophysical parameters include a stereoscopically-derived cloud mask and cloud height on a 1.1 km grid. It also includes cloud motion vectors on a 70.4 km grid. The three types of stereo heights are: the BestWind heights are only calculated for those regions where the associated wind vectors passed the quality tests. Therefore, they have sparse coverage but since the wind correction is included, these contain our 'best guess' as to what the true heights are. The WithoutWind heights are calculated assuming a constant wind vector of zero. They have almost complete coverage and therefore form a nice 'pretty picture' of the relative cloud heights over small areas. The RawWind heights are a diagnostic product as they are calculated using all available wind vectors (even the bad ones). It is therefore recommended that one only use the Best and Without wind products. It is important to remember that the stereo matchers pick up the layer of maximum contrast, which is not necessarily the same as the highest cloud so all the stereo heights are keyed to this level of maximum contrast. Therefore, higher and thinner cirrus layers may not be detected by any of the height fields. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1.1 km; Longitude_Resolution=1.1 km; Temporal_Resolution=about 15 orbits/day].

CLOUD MASK↗

Structural changes and self-activated photoluminescence in reductively annealed Sr{sub 3}AlO{sub 4}F

White light emission of self-activated photoluminescence (PL) in Sr{sub 3}AlO{sub 4}F under 254 nm light is only observed after annealing in a reducing atmosphere of 5%H{sub 2}/95%Ar. High-resolution neutron powder diffraction reveals that the FSr{sub 6} octahedrons and AlO{sub 4} tetrahedrons in this anti-perovskite structure are closer packed in reduced than in air-annealed samples which show no PL. Careful analysis of temperature-dependent neutron powder diffraction data establishes smaller isotropic displacement parameters for Sr(1) and O in Sr{sub 3}AlO{sub 4}F annealed in a reducing atmosphere indicating that the denser packing of the polyhedral sub-units leads to a slightly deeper potential for the Sr(1) and O atoms. Both the air- and reductively-annealed samples have identical thermal expansion within the temperature range between 3 and 350 K. The Debye temperatures were calculated using the atomic displacement parameters and show no significant differences between the air and reductively annealed samples making the Debye temperature a bad proxy for self-activated PL. - Graphical abstract: Annealing Sr{sub 3}AlO{sub 4}F under reducing conditions results in an intense self-activated photoluminescence which is correlated with a denser packing of FSr{sub 6} and AlO{sub 4} polyhedra. - Highlights: • Sr{sub 3}AlO{sub 4}F made in air does not show self-activated photoluminescence. • Only when annealing Sr{sub 3}AlO{sub 4}F in a reducing gas is photoluminescence observed. • FSr{sub 6} and AlO{sub 4} polyhedra in reduced Sr{sub 3}AlO{sub 4}F structure are packed more efficient. • Smaller displacement parameters are found for under-bonded Sr(1) and O sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary floor, seat, and dummy data

According to preliminary examination of the data, out of 179 data channels that were onboard the aircraft in support of the seat experiments, there is data from 168. There was somewhat more severe environment imposed in the structure of the obstacles than by the ground impact. Therefore, both ground impact and obstacle impact are of interest for crashworthiness experiments. Most of the data channels that were studied are fairly consistent with the physical evidence: they show acceleration levels that are reasonable, and in many cases these integrate out to a reasonable velocity change. Finally, from observation thus far, the ground impact did not fail or significantly damage any seat. Nor did any of the energy absorbers in the modified seats extend. The accelerations do not appear high enough and/or energetic enough to cause this to happen. At this time, the onboard films have not been studied; only some videotape have been viewed. Some of the seats were so badly damaged by the fire that any failures which might have occurred were obscured. A close examination of the onboard films using a stop-action projector will allow a more thorough evaluation.

Cannon, M. R.↗

MISR Level 2 TOA/Cloud Stereo parameters (MIL2TCST_V1)

The MISR Top-of-Atmosphere (TOA)/Cloud Stereo geophysical parameters include stereoscopically-derived cloud motion vectors (winds), cloud-top heights, and an accompanying cloud mask. The Stereo product geophysical parameters include a stereoscopically-derived cloud mask and cloud height on a 1.1 km grid. It also includes cloud motion vectors on a 70.4 km grid. The three types of stereo heights are: the BestWind heights are only calculated for those regions where the associated wind vectors passed the quality tests. Therefore, they have sparse coverage but since the wind correction is included, these contain our 'best guess' as to what the true heights are. The WithoutWind heights are calculated assuming a constant wind vector of zero. They have almost complete coverage and therefore form a nice 'pretty picture' of the relative cloud heights over small areas. The RawWind heights are a diagnostic product as they are calculated using all available wind vectors (even the bad ones). It is therefore recommended that one only use the Best and Without wind products. It is important to remember that the stereo matchers pick up the layer of maximum contrast, which is not necessarily the same as the highest cloud so all the stereo heights are keyed to this level of maximum contrast. Therefore, higher and thinner cirrus layers may not be detected by any of the height fields. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1.1 km; Longitude_Resolution=1.1 km; Horizontal_Resolution_Range=1 km - < 10 km or approximately .01 degree - < .09 degree; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=Daily - < Weekly].

EOSDIS↗

The Good, the Bad, and the Ugly: Pseudopotential Inconsistency Errors in Molecular Applications of Density Functional Theory

The pseudopotential (PP) approximation is one of the most common techniques in computational chemistry. Despite its long history, the development of custom PPs has not tracked with the explosion of different density functional approximations (DFAs). As a result, the use of PPs with exchange/correlation models for which they were not developed is widespread, although this practice is known to be theoretically unsound. The extent of PP inconsistency errors (PPIEs) associated with this practice has not been systematically explored across the types of energy differences commonly evaluated in chemical applications. Here, we evaluate PPIEs for a number of PPs and DFAs across 196 chemically relevant systems of both transition-metal and main-group elements, as represented by the W4-11, TMC34, and S22 data sets. Near the complete basis set limit, these PPs are found to cleanly approach all-electron (AE) results for noncovalent interactions but introduce root-mean-squared errors (RMSEs) upwards of 15 kcal mol –1 into predictions of covalent bond energies for a number of popular DFAs. We achieve significant improvements through the use of empirical atom- and DFA-specific PP corrections, indicating considerable systematicity of the PPIEs. The results of this work have implications for chemical modeling in both molecular contexts and for DFA design, which we discuss.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Is the 80 - 20 Principle a Friend or a Foe? Critical Remarks on the Dominant Flat Gradient - 17206

The well-known 80 - 20 principle, also known as the Pareto principle, describes the fact that usually 80 % of the result is achieved by 20 % of the effort, because many probability distributions are caused by a power-law. This principle is valued in the realm of project management and management in general because of the fast progress which generally takes place in the first fifth of the process. If the final result is not exactly specified or resources are spent wisely, 100 % of the planned result will be reached easily. However, in nuclear business safety is a principal parameter. Therefore precision is inevitable. In long-lasting projects the bad end of the Pareto-distribution is dominant: The very shallowly-inclined gradient at the end of the graph means that results at that point come at a very high effort and cost. The graph reaches the 100% only asymptomatically, meaning the initially projected results are never met. Especially if in earlier project phases the Pareto principle is applied very successfully, a lot of work is transferred to the future. For example, in decommissioning projects the waste often is badly characterized causing an enormous effort in the process of characterization and qualification. Especially if funding or time are limited, it is important to be aware of the asymmetric distribution of applied work and result. The 80 - 20 principle is a great advantage, if you start a project and respect the asymmetric distribution of applied resources and results in your project plan. Especially in long-lasting projects with changing perspectives, this asymmetric distribution may cause massive delays and expansion of costs, because small changes near the end cause large/big effort due to consequences on the existing data. If the proper goal of a project is not entirely known in the beginning, it is very probable that the last 5 - 10 % of the result will cause major financial threat and extensions of the estimated time frame. If funding or time are limited, it is almost impossible to readjust a project in the estimated frame of resources. In this case a complete restart of the project may be more reasonable than a long-lasting change management with uncertain results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Individual NSLS-II Multipole Magnet Alignment by Laser Trackers

The magnet alignment of the 90 th and final multipole girder assembly was completed January 17 th , 2013. Our procedure of “rough” pre-alignment by laser trackers and final alignment by vibrating wire & “Differential Variable Reluctance Transducers” (DVRT) has been quite successful, achieving magnet to magnet alignment well under the 30 micron specification. The pre-alignment accuracy is verified by the initial scan from the vibrating wire. The alignment residuals can be calculated from the offsets of a best fit line. The results are impressive, especially considering the environment of the Building 902 Annex (which has a large bay door that would open during pre-alignment, without fail), the sloppiness of the magnets’ fiducials, and especially the fact that the girders were pre-aligned to their mechanical centers, but the vibrating wire reports the magnetic centers which may be considerably different. This result hints at the potential feasibility of alignment with laser trackers for replacement magnets of NSLS-II and maybe even all magnets of future accelerators. But, it is difficult to predict the achievable accuracy until the main three error sources (a.k.a. Survey group excuses) are eliminated: measuring environment, bad magnet fiducials, and mechanical/magnetic center differences. The test performed on a large aperture quadrupole on girder assembly C19G4 was designed to answer the following questions with the aforementioned error sources either eliminated or simulated: 1) How accurately can a NSLS-II multipole be realigned after repair or other disturbance given the existing fiducials? 2) How accurately can a replacement NSLS-II multipole be installed in situ if its magnetic center is known relative to good fiducials? 3) If the current NSLS-II spares are never magnetically fiducialized, how well can they be installed using only mechanical data? 4) Could the magnets of a future accelerator (with similar alignment specifications as NSLS-II) be aligned using commercially available metrology instruments? This paper will answer these questions.

36 MATERIALS SCIENCE↗

X-ray lines from dark matter: the good, the bad, and the unlikely

We consider three classes of dark matter (DM) models to account for the recently observed 3.5 keV line: metastable excited state DM, annihilating DM, and decaying DM. We study two examples of metastable excited state DM. The first, millicharged composite DM, has both inelasticity and photon emission built in, but with a very constrained parameter space. In the second example, up-scattering and decay come from separate sectors and is thus less constrained. The decay of the excited state can potentially be detectable at direct detection experiments. However we find that CMB constraints are at the border of excluding this as an interpretation of the DAMA signal. The annihilating DM interpretation of the X-ray line is found to be in mild tension with CMB constraints. Lastly, a generalized version of decaying DM can account for the data with a lifetime exceeding the age of the Universe for masses ∼<10{sup 6} GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-AB-207A-03: Image Quality, Dose, and Clinical Applications

Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid-changing advanced technologies given the two-hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X-ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in-depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off-focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross-talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel-beam, fan-beam, and cone-beam geometries will be discussed. To address the issue of radiation dose related to x-ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non-ideal conditions of major system components, image artifact often arise in the reconstructed images. Because of the limited scope of this course, only major imaging artifacts, their appearance, and possible mitigation and corrections will be discussed. Assessment of the performance of a CT scanner is a complicated subject. Procedures to measure common image quality metrics such as high contrast spatial resolution, low contrast detectability, and slice profile will be described. The reason why these metrics used for FBP may not be sufficient for statistical iterative reconstruction will be explained. Optimizing radiation dose requires comprehension of CT dose metrics. This course will briefly describe various dose metrics, and interaction with acquisition parameters and patient habitus. CT is among the most frequently used imaging tools due to its superior image quality, easy to operate, and a broad range of applications. This course will present several interesting CT applications such as a mobile CT unit on an ambulance for stroke patients, low dose lung cancer screening, and single heartbeat cardiac CT. Learning Objectives: Understand the function and impact of major components of X-ray tube on the image quality. Understand the function and impact of major components of CT detector on the image quality. Be familiar with the basic procedure of CT image reconstruction. Understand the effect of image reconstruction on CT image quality and artifacts. Understand the root causes of common CT image artifacts. Be familiar with image quality metrics especially high and low contrast resolution, noise power spectrum, slice sensitivity profile, etc. Understand why basic image quality metrics used for FBP may not be sufficient to characterize the performance of advanced iterative reconstruction. Be familiar with various CT dose metrics and their interaction with acquisition parameters. New development in advanced CT clinical applications. JH: Employee of GE Healthcare. FD: No disclosure.; J. Hsieh, Jiang Hsieh is an employee of GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Observations of frontal zone structures with a VHF Doppler radar and radiosondes, part 1.2A

The SOUSY-VHF-Radar is a pulsed coherent radar operating at 53.5 MHz and located near Bad Lauterbert, West Germany. Since 1977, the facility, operated by the Max-Planck-Institut fur Aeronomie, has been used to make a series of frontal passage observations in the spring and fall. Experiments in winter have been difficult because part of the transmitting and receiving array is usually covered by snow during that part of the year. Wavelengths around 6 m are known to be sensitive to the vertical temperature structure of the atmosphere (GREEN and GAGE, 1980; RASTOGI and ROTTGER, 1982). Thus, it has been possible to use radars operating at frequencies near 500 MHz to locate the tropopause. Comparisons between radar data and radiosonde data have shown that there is a large gradient in the radar reflectivity at the height where the radiosonde tropopause occurs. An experiment carried out by ROTTGER (1979) on March 15 to 16, 1977, showed that the radar's sensitivity to the vertical temperature structure could also be used to locate the position of fronts. The SOUSY-VHF-Radar consists of a transmitting array, also used for receiving in some configurations, that can be scanned in the off-vertical direction but not at sufficiently low elevation angles to study the horizontal extent of structures.

Larsen, M. F.↗

Performance of mean-frequency estimators for Doppler radar and lidar

The performance of mean-frequency estimators for Doppler radar and lidar measurements of winds is presented in terms of two basic parameters: Phi, the ratio of the average signal energy per estimate to the spectral noise level; and Omega, which is proportional to the number of independent samples per estimate. For fixed Phi and Omega, the Cramer-Rao bound (CRB) (theoretical best performance) for unbiased estimators of mean frequency (normalized by the spectral width of the signal), signal power, and spectral width are essentially independent of the number of data samples M. For large Phi, the estimators of mean frequency are unbiased and the performance is independent of M. The spectral domain estimators and covariance based estimators are bounded by the approximate period of M. The spectral domain estimators and covariance based estimators are bounded by the approximate periodogram CRB. The standard deviation of the maximum-likelihood estimator approaches the exact CRB, which can be more than a factor of 2 better than the performance of the spectral domain estimators or covariance-based estimators for typical Omega. For small Phi, the estimators are biased due to the effects of the uncorrelated noise (white noise), which results in uniformly distributed 'bad' estimates. The fraction of bad estimates is a function of Phi and M with weak dependence on the parameter Omega. Simple empirical models describe the standard deviation of the good estimates and the fraction of bad estimates. For Doppler lidar and for large Phi, better performance is obtained by using many low-energy pulses instead of one pulse with the same total energy. For small Phi, the converse is true.

Frehlich, R. G.↗

Local lattice distortions drive the transition of BaIrO 3 into a ferromagnetic insulator state

Using variable temperature total and resonant x-ray scattering at the K edge of Ir species, we study the “bad metal” to insulator transition in BaIrO 3 , a canonical third transition series oxide. The usage of advanced experimental techniques and large-scale computer modeling helps us show that, contrary to the widely accepted view, charge disproportionation leading to the formation of Ir-trimers with a different number of 5d valence electrons already exists at room temperature. The charge disbalance between the trimers does not evolve much with decreasing temperature while local lattice distortions do, suggesting that the latter and not the former make a key contribution to the emergence of the enigmatic ferromagnetic insulator state of BaIrO 3 . The conclusion is supported by DFT calculations based on unmodified experimental structure data. Our work calls for a reconsideration of the role of lattice distortions in determining the electronic properties of third transition series oxides. It also charts a path to assessing these properties on a realistic and not assumed crystal structure basis.

36 MATERIALS SCIENCE↗

Estimation of attitude sensor timetag biases

This paper presents an extended Kalman filter for estimating attitude sensor timing errors. Spacecraft attitude is determined by finding the mean rotation from a set of reference vectors in inertial space to the corresponding observed vectors in the body frame. Any timing errors in the observations can lead to attitude errors if either the spacecraft is rotating or the reference vectors themselves vary with time. The state vector here consists of the attitude quaternion, timetag biases, and, optionally, gyro drift rate biases. The filter models the timetags as random walk processes: their expectation values propagate as constants and white noise contributes to their covariance. Thus, this filter is applicable to cases where the true timing errors are constant or slowly varying. The observability of the state vector is studied first through an examination of the algebraic observability condition and then through several examples with simulated star tracker timing errors. The examples use both simulated and actual flight data from the Extreme Ultraviolet Explorer (EUVE). The flight data come from times when EUVE had a constant rotation rate, while the simulated data feature large angle attitude maneuvers. The tests include cases with timetag errors on one or two sensors, both constant and time-varying, and with and without gyro bias errors. Due to EUVE's sensor geometry, the observability of the state vector is severely limited when the spacecraft rotation rate is constant. In the absence of attitude maneuvers, the state elements are highly correlated, and the state estimate is unreliable. The estimates are particularly sensitive to filter mistuning in this case. The EUVE geometry, though, is a degenerate case having coplanar sensors and rotation vector. Observability is much improved and the filter performs well when the rate is either varying or noncoplanar with the sensors, as during a slew. Even with bad geometry and constant rates, if gyro biases are independently known, the timetag error for a single sensor can be accurately estimated as long as its boresight is not too close to the spacecraft rotation axis.

Sedlak, J.↗

WE-G-BRA-08: Failure Modes and Effects Analysis (FMEA) for Gamma Knife Radiosurgery

Purpose: To perform a failure modes and effects analysis (FMEA) study for Gamma Knife (GK) radiosurgery processes at our institution based on our experience with the treatment of more than 13,000 patients. Methods: A team consisting of medical physicists, nurses, radiation oncologists, neurosurgeons at the University of Pittsburgh Medical Center and an external physicist expert was formed for the FMEA study. A process tree and a failure mode table were created for the GK procedures using the Leksell GK Perfexion and 4C units. Three scores for the probability of occurrence (O), the severity (S), and the probability of no detection (D) for failure modes were assigned to each failure mode by each professional on a scale from 1 to 10. The risk priority number (RPN) for each failure mode was then calculated (RPN = OxSxD) as the average scores from all data sets collected. Results: The established process tree for GK radiosurgery consists of 10 sub-processes and 53 steps, including a sub-process for frame placement and 11 steps that are directly related to the frame-based nature of the GK radiosurgery. Out of the 86 failure modes identified, 40 failure modes are GK specific, caused by the potential for inappropriate use of the radiosurgery head frame, the imaging fiducial boxes, the GK helmets and plugs, and the GammaPlan treatment planning system. The other 46 failure modes are associated with the registration, imaging, image transfer, contouring processes that are common for all radiation therapy techniques. The failure modes with the highest hazard scores are related to imperfect frame adaptor attachment, bad fiducial box assembly, overlooked target areas, inaccurate previous treatment information and excessive patient movement during MRI scan. Conclusion: The implementation of the FMEA approach for Gamma Knife radiosurgery enabled deeper understanding of the overall process among all professionals involved in the care of the patient and helped identify potential weaknesses in the overall process.

60 APPLIED LIFE SCIENCES↗

Demonstration of variable speed permanent magnet generator at small, low-head hydro site

Small hydro developers face a limited set of bad choices when choosing a generator for a small low-head hydro site. Direct drive synchronous generators are expensive and technically complex to install. Simpler induction generators are higher speed, requiring a speed increaser, which results in inefficiencies and maintenance problems. In addition, both induction and synchronous generators turn at a fixed speed, causing the turbine to run off its peak efficiency curve whenever the available head is different than the designed optimum head.The solution to these problems is the variable speed Permanent Magnet Generators (PMG). At the Weisenberger Mill in Midway, KY, a variable speed Permanent Magnet Generator has been installed and demonstrated. This new PMG system replaced an existing induction generator that had a HTD belt drive speed increaser system. Data was taken from the old generator before it was removed and compared to data collected after the PMG system was installed. The new variable speed PMG system is calculated to produce over 96% more energy than the old induction generator system during an average year. This significant increase was primarily due to the PMG generator operating at the correct speed at the maximum head, and the ability for the PMG generator to reduce its speed to lower optimum speeds as the stream flow increased and the net head decreased.This demonstration showed the importance of being able to adjust the speed of fixed blade turbines. All fixed blade turbines with varying net heads could achieve higher efficiencies if the speed can be matched to the optimum speed as the head changes. In addition, this demonstration showed that there are many potential efficiencies that could be realized with variable speed technology at hydro sites where mismatched turbine and generator speeds result in lower power output, even at maximum head. Funding for this project came from the US Dept. of Energy, through Award Number DE-EE0005429.

13 HYDRO ENERGY↗