Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PRODUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Simulation of ion beam transport through the 400 Kv ion implanter at Michigan Ion Beam Laboratory

The Michigan Ion Beam Laboratory houses a 400 kV ion implanter. An application that simulates the ion beam trajectories through the implanter from the ion source to the target was developed using the SIMION Registered-Sign code. The goals were to have a tool to develop an intuitive understanding of abstract physics phenomena and diagnose ion trajectories. Using this application, new implanter users of different fields in science quickly understand how the machine works and quickly learn to operate it. In this article we describe the implanter simulation application and compare the parameters of the implanter components obtained from the simulations with the measured ones. The overall agreement between the simulated and measured values of magnetic fields and electric potentials is {approx}10%.

43 PARTICLE ACCELERATORS↗

First experiment with the double solenoid RIBRAS system

A description of the double solenoid system (RIBRAS) operating since 2004 in one of the beam lines of the Pelletron Laboratory of the Institute of Physics of the University of Sao Paulo is presented. The recent installation of the secondary scattering chamber after the second solenoid is reported and the first experiment in RIBRAS using both solenoids is described.

43 PARTICLE ACCELERATORS↗

Beam handling and transport solutions

The main purpose of the present study is to investigate the possibility to characterize the particle beams produced by the laser-target interaction in terms of collection, focusing and energy selection in order to evaluate the feasibility of a laser-driven facility in the field of medical application and, in particular, for hadrontherapy.

43 PARTICLE ACCELERATORS↗

Monte Carlo simulation for the transport beamline

In the framework of the ELIMED project, Monte Carlo (MC) simulations are widely used to study the physical transport of charged particles generated by laser-target interactions and to preliminarily evaluate fluence and dose distributions. An energy selection system and the experimental setup for the TARANIS laser facility in Belfast (UK) have been already simulated with the GEANT4 (GEometry ANd Tracking) MC toolkit. Preliminary results are reported here. Future developments are planned to implement a MC based 3D treatment planning in order to optimize shots number and dose delivery.

43 PARTICLE ACCELERATORS↗

Large dynamic range diagnostics for high current electron LINACs

The Jefferson Lab FEL driver accelerator - Energy Recovery Linac has provided a beam with average current of up to 9 mA and beam energy of 135 MeV. The high power beam operations have allowed developing and testing methods and approaches required to set up and tune such a facility simultaneously for the high beam power and high beam quality required for high performance FEL operations. In this contribution we briefly review this experience and outline problems that are specific to high current - high power non-equilibrium linac beams. While the original strategy for beam diagnostics and tuning have proven to be quite successful, some shortcomings and unresolved issues were also observed. The most important issues are the non-equilibrium (non-Gaussian) nature of the linac beam and the presence of small intensity - large amplitude fraction of the beam a.k.a. beam halo. Thus we also present a list of the possible beam halo sources and discuss possible mitigations means. We argue that for proper understanding and management of the beam halo large dynamic range (>10{sup 6}) transverse and longitudinal beam diagnostics can be used. We also present results of transverse beam profile measurements with the dynamic range approaching 10{sup 5} and demonstrate the effect the increased dynamic range has on the beam characterization, i.e., emittance and Twiss parameters measurements. We also discuss near future work planned in this field and where the JLab FEL facility will be used for beam tests of the developed of new diagnostics.

43 PARTICLE ACCELERATORS↗

Demonstration of cathode emittance dominated high bunch charge beams in a DC gun-based photoinjector

We present the results of transverse emittance and longitudinal current profile measurements of high bunch charge (≥100 pC) beams produced in the DC gun-based Cornell energy recovery linac photoinjector. In particular, we show that the cathode thermal and core beam emittances dominate the final 95% and core emittances measured at 9–9.5 MeV. Additionally, we demonstrate excellent agreement between optimized 3D space charge simulations and measurement, and show that the quality of the transverse laser distribution limits the optimal simulated and measured emittances. These results, previously thought achievable only with RF guns, demonstrate that DC gun based photoinjectors are capable of delivering beams with sufficient single bunch charge and beam quality suitable for many current and next generation accelerator projects such as Energy Recovery Linacs and Free Electron Lasers.

43 PARTICLE ACCELERATORS↗

Formation of a non-Gaussian intensity profile in a waveguide quasi-optical resonator with an aspherical reflector

A method of phase conjugation for formation of non-Gaussian light beams with the specified transverse intensity distribution in waveguide quasi-optical resonators is described. The method is based on the correction of the phase of the fundamental resonator mode by changing the shape of one of the reflectors. The possibility of producing beams with the super-Gaussian and doughnut-like intensity profiles in a waveguide resonator with an aspherical mirror is shown theoretically. The region of geometrical parameters of the resonator is found for which the difference between the phase functions of aspherical and convex spherical resonators is small. The existence of beams with the super-Gaussian intensity profile at the output of a waveguide submillimetre ({lambda} = 0.4326 mm) resonator with a convex spherical mirror is confirmed experimentally. (waveguides and resonators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Features of the formation of a femtosecond Bessel beam by using an axicon

The dynamics of the envelope of a pulsed light beam with the transverse field profile described by the Bessel function is studied theoretically and experimentally. The beam is formed by an axicon from a pulse with the Gaussian spatiotemporal envelope. The appearance of a satellite pulse behind the axicon is predicted. The possibility of generating pulsed Bessel light beams with the required diameter and intensity of the central maximum in optical schemes containing an axicon and a lens is shown. (laser beams)

43 PARTICLE ACCELERATORS↗

Electron beam generation in open hollow-cathode discharge and the characteristics of He-Xe laser on the Xe line at {lambda} = 2.026 {mu}m

An open hollow-cathode discharge, generating an electron beam, is implemented in a cell with an active volume of 6.2 L. An electron-beam current of 3.4 A at an average power of 2.5 kW is obtained in helium in the quasi-cw regime at an anode voltage of 1.5 kV. Lasing in a He-Xe mixture on the 5d[3/2]{sup 0}{sub 1}-6p[3/2]{sub 1} transition in xenon at the wavelength {lambda} = 2.026 {mu}m under electron-beam excitation is investigated. The optimal component ratio in the He : Xe mixture is 99.5 : 0.5 (p{sub He} = 4-8 Torr). The lasing power linearly increases with increasing the electron-beam power. It is shown that the discharge of this type can be used as an electron-beam source for exciting gaseous active media. (lasers)

43 PARTICLE ACCELERATORS↗

Resonant three-Photon Ionization Spectroscopy of Atomic Fe

Laser spectroscopic investigations on high-lying states around the ionization potential in the atomic spectrum of Fe have been carried out for development of a practical three-step resonance ionization scheme accessible by Ti:Sapphire lasers. A hot cavity laser ion source typically used at on-line radioactive ion beam production facilities was employed in this work. Ionization schemes employing high-lying Rydberg and autoionizing states populated by three-photon excitations were established. Five new Rydberg and autoionizing Rydberg series converging to the ground and to the first four excited states of Fe II are reported. Analyses of the Rydberg series yield the value 63737.686 ± 0.068 cm-1 for the ionization potential of iron.

Liu, Yuan↗

Direct particle acceleration by two identical crossed radially polarized laser beams

Electrons and {alpha} particles injected midway between two ultrahigh intensity crossed laser beams of radial polarization are shown to be accelerated in vacuum to several gigaelectron volts and to have average energy gradients in excess of 150 GeV/m. A unique model of the crossing beams is suggested, which maximizes the particle energy gain and minimizes the particle-beam diffraction.

43 PARTICLE ACCELERATORS↗

Precise measurements of the γ -ray intensities following the β decay of Ce 144 and Nd 147

For many fission products, the γ rays emitted following β decay provide an easily detectable signature that can be used to identify their quantities and distributions in a sample. As a result, γ-ray spectroscopy is often exploited to study fission-product yields, provided sufficiently accurate information on the γ-ray intensities is available. Further, in many cases, the uncertainties in the existing nuclear data are large enough that they compromise the precision achievable for modern experiments and applications. In this paper, we present high-precision results for the absolute γ-ray emission intensities for the most intense transitions in the β decays of 144 Ce and 147 Nd. We measured these intensities to ≲1% accuracy by producing radiopure samples with fission-product beams at CARIBU and detecting the emitted radiation with a 4⁢πβ counter and a meticulously efficiency-calibrated high purity germanium detector at Texas A&M University.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generating Ultrarelativistic Attosecond Electron Bunches with Laser Wakefield Accelerators

Femtosecond electron bunches with ultrarelativistic energies were recently generated by laser wakefield accelerators. Here we predict that laser wakefield acceleration can generate even attosecond bunches, due to a strong chirp of the betatron frequency. We show how the bunch duration scales with the acceleration parameters and that, after acceleration, the bunches can propagate over many tens of centimeters without a significant increase in duration.

43 PARTICLE ACCELERATORS↗

Electron Beam Emission from a Diamond-Amplifier Cathode

The diamond amplifier (DA) is a new device for generating high-current, high-brightness electron beams. Our transmission-mode tests show that, with single-crystal, high-purity diamonds, the peak current density is greater than 400 mA/mm{sup 2}, while its average density can be more than 100 mA/mm{sup 2}. The gain of the primary electrons easily exceeds 200, and is independent of their density within the practical range of DA applications. We observed the electron emission. The maximum emission gain measured was 40, and the bunch charge was 50 pC/0.5 mm{sup 2}. There was a 35% probability of the emission of an electron from the hydrogenated surface in our tests. We identified a mechanism of slow charging of the diamond due to thermal ionization of surface states that cancels the applied field within it. We also demonstrated that a hydrogenated diamond is extremely robust.

43 PARTICLE ACCELERATORS↗

Precise absolute 𝛾–ray intensities following the 𝛽 decay of 156 Eu

The most recent 𝛽-decay data for 156 Eu is over 40 years old, and the 𝛾-ray intensities are only known with a fractional precision of about 10% or worse. Here, in this work, we present new results for the absolute intensities of more than 60 𝛾 rays emitted following the 𝛽 decay of 156 Eu with many measured to ≲1% accuracy, representing an order-of-magnitude improvement in precision. This was achieved by leveraging the fission-product beams produced at the CARIBU facility to create radio-pure samples and detecting the radiation with a 4⁢𝜋 𝛽-particle counter coupled with a precisely efficiency-calibrated HPGe detector at Texas A and M University.

Physics - Nuclear physics and radiation physics↗

X-Ray Line Polarization of Ne-Like Mo Spectra from X-pinch Plasmas

In this study, linearly polarized spectral emission is induced by non-Maxwellian electrons with anisotropic velocity distributions through collisional processes with ions in plasmas. X-ray line polarization is a viable diagnostic tool for the study of these electrons, which has been tested in controlled settings, e.g., the electron beam ion trap, but due to strong depolarization effects, has been relatively unexplored in laboratory-produced high-energy-density plasmas. This paper explores the X-ray line polarization for the study of Ne-like molybdenum X-pinch plasmas. Previous polarization studies have focused mostly on K-shell spectral lines, whereas the current paper expands on these studies by investigating L-shell line polarization. The X-pinch is favorable due to its high-density plasma formation, high radiation yield, fixed hotspot location, and reliable electron beam production. L-shell X-ray line polarization and spectral emission of Mo X-pinches were investigated through dual α-quartz (2d=6.687 Å) crystal spectropolarimetry with axial and radial spatial resolution. In particular, line polarization is evaluated through a comparative analysis of relative line intensities observed over a range of Ne-like Mo transitions simultaneously recorded with two spectrometers with different sensitivity to polarization. An appreciable degree of X-ray line polarization (up to 15%) is observed in the Ne-like Mo plasmas and analyzed using depolarization effects. Lastly, these results are the first polarization measurements in high-Z pulsed power plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-145: Beam Characteristics of Flattening Filter Free Beams Including Low Dose Rate Setting

Purpose: In commissioning of volumetric modulated arc therapy (VMAT), it is necessary to evaluate the beam characteristics of various dose rate settings with potential to use. The aim of this study is to evaluate the beam characteristics of flattened and flattening filter free (FFF) including low dose rate setting. Methods: We used a Varian TrueBeam with Millennium 120 MLC. Both 6 and 10 MV beams with or without flattening filter were used for this study. To evaluate low-dose rate FFF beams, specially-designed leaf sequence files control out-of-field MLC leaf pair at constant dose rate ranging from 80 to 400 MU/min. For dose rate from 80 MU/min to the maximum usable value of all energies, beam output were measured using ionization chamber (CC04, IBA). The ionization chamber was inserted into water equivalent phantom (RT3000-New, R-tech), and the phantom was set with SAD of 100cm. The beam profiles were performed using the 2D diode array (Profiler2, Sun Nuclear). The SSD was set to 90cm and a combined 30cmx30cmx9cm phantom which consisted of solid water slabs was put on the device. All measurement were made using 100MU irradiation for 10cmx10cm jaw-defined field size with a gantry angle of 0°. Results: In all energies, the dose rate dependences with beam output and variation coefficient were within 0.2% and 0.07%, respectively. The flatness and symmetry exhibited small variations (flatness ≤0.1 point and symmetry≤0.3 point at absolute difference). Conclusion: We had studied the characteristics of flattened and FFF beam over the 80 MU/min. Our results indicated that the beam output and profiles of FFF of TrueBeam linac were highly stable at low dose rate setting.

60 APPLIED LIFE SCIENCES↗

SU-E-T-376: Evaluation of a New Stereotactic Diode for Small Field Dosimetry

Purpose: To evaluate the performance of a new stereotactic diode for dosimetry of small photon fields. Methods: A new stereotactic diode, consisting of an unshielded p-type silicon chip, and with improved radiation hardness energy dependence was recently developed (IBA Dosimetry, Schwarzenbruch, Germany). The diode has an active volume of 0.6 mm dia. x 0.02 mm thick. Two new diodes were evaluated, one which was pre-irradiated to 100kGy with 10 MeV electrons and another which received no prior irradiation. Sensitivity, stability, reproducibility, and linearity as a function of dose were assessed. Beam profiles and small field output factors were measured on a CyberKnife (CK) and compared with measurements using two commercially available diodes. Results: The new diodes exhibit linear behavior (within 0.6%) over a dose range 0.02 – 50 Gy; a commercially available device exhibits excursions of up to 4% over the same range. The sensitivity is 4.1 and 3.8 nC/Gy for the un-irradiated and pre-irradiated diodes, respectively. When irradiated with 150 Gy in dose increments of 5, 20 and 35 Gy, both new diodes provide a stable response within 0.5%. Output factors measured with the two new diodes are identical and compare favorably with other commercially available diodes and published data. Similarly, no differences in measured field size or penumbra were observed among the devices tested. Conclusion: The new diodes show excellent stability and sensitivity. The beam characterization in terms of output factors and beam profiles is consistent with that obtained with commercially available diodes.

60 APPLIED LIFE SCIENCES↗