Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Associated Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Optimal strategies for a cost-effective and reliable 100% renewable electric grid

This paper explores cost-optimal pathways to 100% renewable power systems for the U.S. building stock. We show that long-duration misalignments of supply and demand, spanning from multi-day to seasonal timescales, present a dominant challenge that must be addressed to meet real-time 100% renewable targets. While long-duration misalignments can be addressed through energy storage, we show that alternative and readily available solutions that are more cost-effective should be considered first. Through a techno-economic analysis, we identify cost-optimal, region-dependent, supply-side, and demand-side strategies that reduce, and in some U.S. regions eliminate, the otherwise substantial capacities and associated costs of long-duration energy storage. Investigated supply-side strategies include optimal mixes of renewable portfolios and oversized generation capacities. Considered demand-side strategies include building load flexibility and building energy efficiency investments. Our results reveal that building energy efficiency measures can reduce long-duration storage requirements at minimum total investment costs. In addition, oversizing and diversifying renewable generation can play a critical role in reducing storage requirements, remaining cost effective even when accounting for curtailed generation. We identify regionally dependent storage cost targets and show that for emerging long-duration energy storage innovations to achieve broad adoption, their costs will need to compete with the decreasing cost of renewables. The findings of this research are particularly important given that most long-duration storage technologies are currently either uneconomical, geologically constrained, or still underdeveloped.

100% renewable↗

SUBTASK 1.6 – BASIN ELECTRIC CARBON STORAGE RESEARCH PROJECT: NOVEL MONITORING TECHNIQUES

The Energy & Environmental Research Center (EERC) conducted baseline activities associated with an applied research project at Basin Electric Power Cooperative’s (Basin’s) carbon capture and storage (CCS) site in Beulah, North Dakota, to establish novel carbon storage-monitoring techniques as commercial methods under Cooperative Agreement No. DE-FE0024233, Subtask 1.6. The following report summarizes the baseline activities performed and briefly describes the subsequent (operational monitoring) activities that have been proposed to the U.S. Department of Energy (DOE) as part of the overall project to develop and demonstrate novel monitoring techniques at North America’s largest permitted CCS operation. Dakota Gasification Company (DGC), a wholly owned subsidiary of Basin, owns and operates the Great Plains Synfuels Plant (GPSP) approximately 5 miles northwest of the town of Beulah, North Dakota (Figure 1). In 2023, DGC received approval from the North Dakota Industrial Commission (NDIC) to develop a storage facility on-site for injecting a stream of carbon dioxide (CO2) captured from GPSP. DGC will transport the captured CO2 stream with approximately 6.8 miles of transmission lines that extend north of GPSP and inject >1 million tonnes (MMt) of CO2 annually (>1 MMt/yr) over a 12-year period with up to six underground injection control (UIC) Class VI-compliant injection wells completed in the Broom Creek Formation, a predominantly sandstone reservoir and saline aquifer underlying GPSP. The Broom Creek Formation lies approximately 5900 feet (ft) below ground surface (bgs) at GPSP. The commercial scale (i.e., >1 MMt/yr) of DGC’s permitted carbon storage project is ideal for developing and testing the novel monitoring techniques included within Subtask 1.6. The goals of this project are to demonstrate 1) the cost-effectiveness of novel monitoring technologies included as part of this research, 2) technology capability for tracking the CO2 plume and/or associated pressure response in the subsurface and monitoring out-of-zone migration, and 3) compliance with UIC Class VI program requirements. The research activities proposed for the overall project include 1) design of an automated, integrated, modular (AIM) monitoring station; 2) time-lapse electromagnetic (EM) field surveys; 3) drone-based surveillance studies; 4) time-lapse monitoring with seismic methods; 5) advanced wellbore-monitoring methods; 6) deployment of an AIM monitoring network; 7) EM monitoring of CO2 with real-time data processing; 8) continued seasonal drone-based surveillance studies; 9) seismic monitoring with passive and active surveys; and 10) wellbore monitoring with nuclear magnetic resonance (NMR) for near-surface characterization. Completion of Activities 1.0–5.0 (baseline activities) are described in this report. Upon authorization of funding by DOE, the EERC will initiate Activities 6.0– 10.0 (operational monitoring activities). Current state-of-the-art (SOA) carbon storage-monitoring techniques require countless labor hours dedicated to the acquisition of data. Once data are gathered, these SOA techniques often rely on commercial facilities to process raw data from the field. However, it is anticipated that next-generation monitoring techniques, such as those being demonstrated, will lower acquisition footprints, be less operationally intensive, and improve data acquisition efficiencies. These new techniques are more conducive to the application of machine learning, artificial intelligence, and automation, thus providing a pathway for integration into active control systems, informing site operability, and improving the integration of data for future CCS projects across the United States. Additionally, reclaimed and active mining lands are present within the project site, creating a unique opportunity to demonstrate the effectiveness of remote sensing and surface-based geophysics monitoring techniques at similar project sites that may include disturbed, unconsolidated, or actively excavated near-surface environments. The efforts included in the overall project will produce necessary designs, learnings, and data acquired during the baseline and operational monitoring periods that are necessary for time-lapse demonstration and validation of the described monitoring techniques. In addition, it is anticipated that the monitoring technologies included in this study will be compliant with UIC Class VI requirements to enable the potential for implementation at other CCS sites across the United States.

42 ENGINEERING↗

An innovative, multidisciplinary educational program in interactive information storage and retrieval. Presentation visuals

This Working Paper Series entry represents a collection of presentation visuals associated with the companion report entitled An Innovative, Multidisciplinary Educational Program in Interactive Information Storage and Retrieval, USL/DBMS NASA/RECON Working Paper Series report number DBMS.NASA/RECON-12. The project objectives are to develop a set of transportable, hands-on, data base management courses for science and engineering students to facilitate their utilization of information storage and retrieval programs.

Dominick, Wayne D.↗

Magnetic Analog Random-Access Memory

Proposed integrated, solid-state, analog random-access memory base on principle of magnetic writing and magnetoresistive reading. Current in writing conductor magnetizes storage layer. Remanent magnetization in storage layer penetrates readout layer and detected by magnetoresistive effect or Hall effect. Memory cells are part of integrated circuit including associated reading and writing transistors. Intended to provide high storage density and rapid access, nonvolatile, consumes little power, and relatively invulnerable to ionizing radiation.

Katti, Romney R.↗

Gain and energy storage in holmium YLF

It is demonstrated that Q-switched holmium lasers are capable of high-gain and high-energy operation at 300 K. Small-signal gain coefficients of 0.50 and 0.12/cm have been measured in YLF and YAG, respectively. Small-signal gains of 0.50/cm are comparable to those achievable in Nd:YAG and are not typical of low-gain materials. This large gain in the Ho:YLF material is made possible by operating the amplifier in the ground state depletion mode. The amplifier performance data and associated analysis presented demonstrate that efficient energy storage is possible with very high excited state ion densities of the Ho 5I7 upper laser level. This is an important result since upconversion can limit the 5I7 population. Although upconversion was still present in this experiment, it was possible to achieve efficient energy storage, demonstrating that the problem is manageable even at high excitation densities in YLF.

Storm, Mark E.↗

Hybrid Uses of High-Temperature Reservoir Thermal Energy Storage: Lessons Learned from Previous Projects

One of the critical challenges of the green energy transition is resolving the mismatch between energy generation provided by intermittent renewable energy sources such as solar and wind and the demand for energy. There is a need for large amounts of energy storage over a range of time scales (diurnal to seasonal) to better balance energy supply and demand. Subsurface geologic reservoirs provide the potential for storage of hot water that can be retrieved when needed and used for power generation or direct-use applications, such as district heating. It is important to identify potential issues associated with high-temperature reservoir thermal energy storage (HT-RTES) systems so that they can be mitigated, thus reducing the risks of these systems. This paper reviews past experiences from moderate and high-temperature reservoir thermal energy storage (RTES) projects, along with hot water and steam flood enhanced oil recovery (EOR) operations, to identify technical challenges encountered and evaluate possible ways to address them. Some of the identified technical problems that have impacted system performance include: 1) insufficient site characterization that failed to identify reservoir heterogeneity; 2) scaling resulting from precipitation of minerals having retrograde solubility that form with heating of formation brines; 3) corrosion from low pH or high salinity brines; 4) thermal breakthrough between hot and cold wells due to insufficient spacing. Proper design, characterization, construction, and operational practices can help reduce the risk of technical problems that could lead to reduced performance of these thermal energy storage systems.

energy storage↗

The role of height–driven constraints and compensations on tree vulnerability to drought

Frequent observations of higher mortality in larger trees than in smaller ones during droughts have sparked an increasing interest in size–dependent drought–induced mortality. However, the underlying physiological mechanisms are not well understood, with height–associated hydraulic constraints often being implied as the potential mechanism driving increased drought vulnerability. Here we performed a quantitative synthesis on how key traits that drive plant water and carbon economy change with tree height within species and assessed the implications that the different constraints and compensations may have on the interacting mechanisms (hydraulic failure, carbon starvation and/or biotic–agent attacks) affecting tree vulnerability to drought. While xylem tension increases with tree height, taller trees present a range of structural and functional adjustments, including more efficient water use and transport and greater water uptake and storage capacity, that mitigate the path–length–associated drop in water potential. These adaptations allow taller trees to withstand episodic water stress. Conclusive evidence for height–dependent increased vulnerability to hydraulic failure and carbon starvation, and their coupling to defence mechanisms and pest and pathogen dynamics, is still lacking. Further research is needed, particularly at the intraspecific level, to ascertain the specific conditions and thresholds above which height hinders tree survival under drought.

54 ENVIRONMENTAL SCIENCES↗

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

Silver Ion Biocide Delivery System for Water Disinfection

U.S. space exploration missions have long considered returning to the Moon and exploration of Mars that challenge life support systems. For these long duration missions, there is interest in replacing the iodine water treatment system with ionic silver, a proven biocide. For long duration exploration missions, it is imperative that an effective biocide be used that prevents microbial growth, biofilm formation, and microbially induced corrosion in the water storage and distribution systems while minimizing logistical supply requirements associated with the biocide delivery system. Two biocide delivery systems have been developed that electrochemically produce silver ions for disinfecting water throughout the water storage and distribution system. One system uses a newly developed hybrid micro-filtration and ion-exchange membrane to produce an abundance of silver ions at the 1000 ppb level upstream in the water distribution system to prevent biofilm growth. This is followed by a downstream collection module that electrochemically removes these silver ions before the water is discharged. Another approach uses a membraneless reactor to produce a 1000 ppb silver ion concentration level that also has a mechanically driven electrode cleaning mechanism that removes oxide films ensuring long life operation. By maintaining a sufficiently high level of silver ions throughout the water storage and distribution system, biofilm formation is suppressed. This approach overcomes present concerns where spurious silver deposition occurs on the container and flow line surfaces thus lowering the silver ion concentration to unsatisfactory disinfection levels.

Slote, Benjamin M.↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Impact of Pressure-Dependent Interfacial Tension and Contact Angle on Capillary Heterogeneity Trapping of CO2 in Storage Aquifers

Summary Carbon dioxide (CO2) capillary trapping increases the total amount of CO2 that can be effectively immobilized in storage aquifers. This trapping, manifesting itself as accumulated CO2 columns at a continuum scale, is because of capillary threshold effects that occur below low-permeability barriers. Considering that capillary pressure is dictated by heterogeneous pore throat size, the trapped CO2 column height and associated CO2 saturation will vary spatially within a storage aquifer. This variation will be influenced by two pressure-dependent interfacial parameters—CO2/brine interfacial tension (IFT) and CO2/brine/rock contact angle. Our objective is to understand how the pressure dependence of these two parameters affects the heterogeneity of capillary trapped CO2 at a continuum scale. Our conceptual model is a 1D two-zone system with the upper zone being a flow barrier (low permeability) and the lower zone being a flow path (high permeability). The inputs to this model include microfacies-dependent capillary pressure vs. saturation curves and permeability values. The input capillary pressure curves were collected in the literature that represents carbonate microfacies (e.g., dolograinstone) in a prevalent formation in the Permian Basin. We then used the Leverett j-function to scale the capillary pressure curve for the two zones that are assigned with the same or different microfacies. During scaling, we considered the influence of pressure on both the IFT and contact angle of CO2/brine/dolomite systems. We varied the zone permeability contrast ratio from 2 to 50. We then assumed capillary gravity equilibriums and calculated the CO2 saturation buildup corresponding to various trapped CO2 column heights. The CO2 saturation buildup is defined as the CO2 saturation in the lower layer minus that in the upper one. We found that the saturation buildup can be doubled when varying pressure in a storage aquifer, after considering pressure-dependent IFT and contact angles. Thus, assuming these two parameters to be constant across such aquifers would cause large errors in the quantification of capillary trapping of CO2. The whole study demonstrates the importance of considering pressure-dependent interfacial properties in predicting the vertical distribution of capillary trapped CO2. It has important implications in developing a better understanding of leakage risks and consequent storage safety.

Engineering↗

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

Direct Air Capture of CO 2 and Delivery to Photobioreactors for Algal Biofuel Production (Final Report)

A mobile DAC system was designed and constructed to pair with photobioreactors growing algae for biofuel production. The DAC system was designed as a versatile research system, rather than a compact production unit. The system was constructed and mounted on a mobile skid to facilitate transportation to the algae production site. Within the DAC system, CO 2 was captured using amine-loaded monoliths that allow for high CO 2 uptake with low pressure drop. The CO 2 is collected using a Global Thermostat patented temperature/vacuum swing adsorption (TVSA) process. Amine sorbents and process conditions were optimized to produce 10 to >20 g CO 2 .h-1. The stability of the amine sorbents was also studied, with sorbent modifications made to improve stability to degradation by oxidation. An Algenol-developed Spirulina strain (Arthrospira platensis AB2293) was selected as the production cyanobacterial strain. AB2293 cultured was inoculum for outdoor production following PBR installation by Algenol. The PBR system was composed of three independent PBRs, with each PBR composed of four hanging bags internally recirculated by a liquid turnover pump. The PBRs were operated outdoors in Atlanta, GA, and integrated with the DAC system. Algae were grown with similar productivity using DAC-CO 2 as algae grown using pure CO 2 obtained commercially (Airgas). Throughout the experimental duration, no discoloration was observed, and cellular morphology was consistent between the two experimental treatments. An LCA including lifecycle greenhouse gas emissions, full life cycle inventory of the Algenol system and the DAC system and integrated DAC+PBR system was developed. Lifecycle greenhouse gas emissions were calculated for capture of carbon dioxide using input from Global Thermostat and the National Renewable Energy Laboratory. Three scenarios for energy provision were evaluated: a natural gas combined heat and power system sized to meet the electricity requirement, a natural gas combined heat and power system sized to meet the process heat requirements, and a system without on-site power that procures the electricity from the grid. In all three cases, as expected, the major contributor to the emissions is the energy consumption associated with the desorption step of the DAC process. The LCA quantified the reduced potential energy and greenhouse gas emissions of heat and mass integration of DAC and Algenol compared to unintegrated DAC and Algenol systems. A life cycle assessment of the role of sorbent productivity and lifetime was also developed. The development of more robust, oxidation resistant DAC sorbents may enable small reductions in energy requirements and in lifecycle greenhouse gas emissions and other environmental impacts. NREL performed techno-economic analysis (TEA) to identify the integration scenario most likely to achieve a 15% cost reduction target versus the baseline. Heat and mass integration of DAC and the PBR is critical to minimizing the MFSP. The baseline case utilizes no heat and mass integration, and the DAC system provides 100% of the CO 2 required by the photobioreactors (20 tonnes/hr), operating for 12 hours/day capturing 40 tonnes CO 2 /operating hour. The minimum fuel selling price (MFSP) of ethanol calculated from the baseline case was $10.68/gal ethanol. This corresponds with a targeted MFSP of $9.07/gal ethanol (or 15% reduction). This target was achieved by integration Option 2a with the greatest cost reduction of 17.8% (or $8.78/gal) and integration Option 2b with a cost reduction of 16.4% (or $8.93/gal). Reductions in MFSP are attributed to two primary process considerations: (a) CO 2 storage at night reduces the capital expenses associated with DAC (i.e., increasing on-stream time); and (b) distributed DAC scenarios (DAC-PBR integration Options 2a and 2b) make use of boiler and DAC CHP flue gas CO 2 (free). Direct air capture on-stream time was one of the largest contributors to MFSP reduction.

09 BIOMASS FUELS↗

Simulation of Multiphase Flow and Poromechanical Effects Around Injection Wells in CO 2 Storage Sites

In geological CO 2 storage operations, wellbore deformations and leakage pathways formations can occur around injection and abandoned wells subjected to high rates and long-term CO 2 injection. To guide engineering design and prevent CO 2 leakage risks, a full understanding of the underlying physics and robust numerical models is necessary to evaluate the response of underground formations in the near wellbore region and in the reservoir. In this study, a multi-scale and multi-physics open-source simulator (GEOS) is used to simulate multiphase flow and poromechanical deformations over time in three dimensions. The governing equations for mechanical deformations of the rock body and multiphase compositional fluid flow within the rock matrix are solved with a fully coupled finite element and finite volume approach. The Drucker–Prager model with friction hardening is applied to simulate elastoplastic deformation and a multiphase fluid model with power-law correlations for relative permeability is used to model the migration of CO 2 plume, which are coupled with numerical implicit scheme. Simulation results are verified against multiple analytical solutions for multiphase flow and wellbore problems, thus demonstrating the accuracy of this advanced simulator. In two engineering applications, here we highlight the impact of elastoplastic deformation and coupled modeling for assessing induced displacements and stress perturbations, which are more pronounced in the near wellbore regions. This work focuses on short-term processes in the vicinity of injection wells where stress evolutions, rock deformations and multiphase compositional flow and transport are simulated jointly to ensure wellbore stability and prevent damage. This fully coupled geomechanical model can simulate multiphase flow and any associated poromechanical effects within the CO 2 storage site and in the surrounding formations. Such a large-scale, long-term, multi-physics simulation model is useful in many ways: it can guide operational decisions for CO 2 injection, assess the containment potential and risks of a site, and analyze the wellbore stability and integrity during and after CO 2 injection.

58 GEOSCIENCES↗

A Simple Halogen-Free Magnesium Electrolyte for Reversible Magnesium Deposition through Cosolvent Assistance

Rechargeable Mg batteries are one of the most investigated polyvalent-metal storage batteries owing to the increased safety associated with the nondendritic nature of Mg electrodeposition, high volumetric capacity, and low cost. To realize the commercial applications of Mg batteries, there are still a number of challenges remaining unsolved, in particular, the lack of halogen free Mg electrolytes, as the use of the halogens remains a major limiting factor to achieving high voltage cathodes. The research presented here introduces an innovative approach to prepare a halogen-free Mg-based electrolyte in a simple, nonsynthetic method that can plate and strip Mg reversibly. Results suggest that by introducing a secondary amine cosolvent the magnesium bis(trifluoromethanesulfonyl)imide (Mg(TFSI) 2 ) salt can be easily dissolved into a wide array of polar but aprotic ether solvents. A systematic structural investigation of a representative Mg(TFSI) 2 electrolyte in the cosolvent systems with the secondary amine was performed using pair distribution function (PDF) analysis, single crystal diffraction analysis, and NMR. The experimental atomic scale understanding reveals an ion pair structure of Mg 2+ coordinated with six oxygen donors from the bis(trifluoromethanesulfonyl)imide (TFSI) anions and the THF solvent located in the first solvation shell. The as-formed neutral ion pair structure acts as the active component for reversible Mg deposition. We believe this new route of preparing Mg electrolytes can extend the current understanding of Mg electrolyte functionality for rechargeable Mg batteries and offers more guidance for the future electrolyte design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UV-Induced Degradation and Associated Metastability in TOPCon Photovoltaic Modules: Understanding Kinetics and Cell Variance

Tunnel oxide passivated contact (TOPCon) silicon photovoltaic (PV) modules are dominating the PV market, but they may be susceptible to degradation under ultraviolet (UV)-containing light. Quantifying the impacts of UV-induced degradation (UVID) is complicated by an associated metastability causing further degradation under dark storage and rapid recovery under sunlight. Here, we study modules that have -2.3% to -3.2% nonrecoverable UVID loss after 60 kWh/m2 dose of 340 nm light and additional recoverable loss under dark storage. We use in situ electroluminescence (EL) imaging to characterize the post-UVID metastability at the module level. The cell-by-cell dark degradation and recovery kinetics span a wide range from +6% to -70% changes in EL intensity after 520 h of dark storage, which returns to +- 4% of the initial post-UVID EL intensity after illumination. The kinetics follow double exponential rates with dark storage degradation time constants of 345 and 45 h, and UV light recovery time constants of 5 min and 36 s. We propose that this is consistent with prior reports of kinetics for light-soaking metastability in Al2O3 passivation. Finally, we further show that cells having high UVID also have injection-dependent effective carrier lifetimes and significant intra-cell variance, suggesting possible origins of processing inconsistency.

14 SOLAR ENERGY↗