Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

WE-G-BRE-06: New Potential for Enhancing External Beam Radiotherapy for Lung Cancer Using FDA-Approved Concentrations of Cisplatin Or Carboplatin Nanoparticles Administered Via Inhalation

Purpose: This study investigates, for the first time, the dose enhancement to lung tumors due to cisplatin nanoparticles (CNPs) and carboplatin nanoparticles (CBNPs) administered via inhalation route (IR) during external beam radiotherapy. Methods: Using Monte Carlo generated 6 MV energy fluence spectra, a previously employed analytic method was used to estimate dose enhancement to lung tumor due to radiation-induced photoelectrons from CNPs administered via IR in comparison to intravenous (IV) administration. Previous studies have indicated about 5% of FDA-approved cisplatin concentrations reach the lung tumor via IV. Meanwhile recent experimental studies indicate that 3.5–14.6 times higher concentrations of CNPs can reach the lung tumors by IR compared to IV. Taking these into account, the dose enhancement factor (DEF) defined as the ratio of the dose with and without CNPs was calculated for field size of 10 cm × 10 cm (sweeping gap), for a range of tumor depths and tumor sizes. Similar calculations were done for CBNPs. Results: For IR with 3.5 times higher concentrations than IV, and 2 cm diameter tumor, clinically significant DEF values of 1.19–1.30 were obtained for CNPs at 3–10 cm depth, respectively, in comparison to 1.06–1.09 for IV. For CBNPs, DEF values of 1.26–1.41 were obtained in comparison to 1.07–1.12 for IV. For IR with 14.6 times higher concentrations, higher DEF values were obtained e.g. 1.81–2.27 for CNPs. DEF increased with increasing field size or decreasing tumor size. Conclusions: Our preliminary results indicate that major dose enhancement to lung tumors can be achieved using CNPs/CBNPs administered via IR, in contrast to IV administration during external beam radiotherapy. These findings highlight a potential new approach for radiation boosting to lung tumors using CNPs/CBNPs administered via IR. This would, especially, be applicable during concomitant chemoradiotherapy, potentially allowing for dose enhancement while minimizing normal tissue toxicities.

60 APPLIED LIFE SCIENCES↗

Analysis of the nuclear measurement program for an optimized BR2 core configuration

This paper presents the analysis of the results of the Nuclear Measurement Program (NMP) executed during the shut-down of cycle 05/2012 of the BR2 reactor. The aim of the NMP was to determine the properties of a reactor core load with a new configuration of the control rods and to evaluate/verify the predicted numerical results by MCNPX. The methods used for the interpretation of the measurement results include combinations of an analytical method for determination of the axial relative control rod efficiency and least square techniques. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In Vitro Assessment of the In Vivo Stability of Cu-64 Radiopharmaceuticals

Research Plans: The successful development of Cu-64 radiopharmaceuticals depends upon retention of the Cu-64 atom in the radiopharmaceutical. To date, the focus has been on the development of chelators that better retain Cu-64, but there has been no effort to develop an effective method by which improved retention may be measured. In the absence of a suitable analytical method, the stability of Cu-64 radiopharmaceuticals is estimated indirectly, with decreased liver uptake suggesting higher in vivo complex stability. But this approach is inadequate for radiopharmaceuticals, such as radiolabeled antibodies, that are expected to accumulate in the liver even when there is no free Cu-64 present. The absence of such a method has also hampered efforts to systematically evaluate the chemical factors that may give rise to improved retention. The objective of this project is to develop and validate such a method. Accomplishments: The two primary accomplishments of this project will be 1) the development and validation of a method to measure the stability of Cu-64 radiopharmaceuticals and 2) the determination of the chemical factors that define the in vivo stability of Cu 64 radiopharmaceuticals. Because Cu(II) is extremely labile, the in vivo stability of Cu-64 radiopharmaceuticals is not primarily determined by the amount of free Cu that is present at any given time or by the thermodynamic stability constants, but rather by the rate at which Cu is lost from the complex, the dissociation rate constant, kd. The dissociation rate constants of the Cu-64 complexes from a series of bifunctional chelators (BFCs) will be measured using Free Ion Selective Radiotracer Extraction (FISRE), a technique originally developed to measure bioavailable Cu in environmental samples. FISRE will also be applied to the determination of the kd's of a series of reference Cu-64 complexes to determine the chemical factors that define the in vivo stability of Cu-64 radiopharmaceuticals. Potential Benefits: The FISRE method that will be used in this project, once validated, will provide researchers with a core technology by which the stability of Cu 64 radiopharmaceuticals can be accurately measured. In the short-term, we expect to produce extensive data regarding the stability of Cu-64 complexes of ligands of radiopharmaceutical interest, primarily those that are most commonly used as BFCs (e.g., DOTA, TETA). These data will provide a quantitative basis for deciding which ligands may be best suited for use as BFCs, data that is not currently available. In the intermediate term, we expect that these results will facilitate the development of new Cu-64 radiopharmaceuticals by providing a quantitative approach to assessing the stability of Cu-64 chelates. This innovative methodology will enable investigators to quantitatively compare the ability of different BFCs to retain Cu-64 in vivo. The benefits of this approach will be best seen in the development of Cu-64-labeled monoclonal antibodies where the accumulation of antibodies in the liver obviates liver uptake as an effective surrogate measure of Cu-64 lability. In the longer-term, we anticipate an improvement in the way in which various diseases (especially cancer) are detected, diagnosed, staged, and treated. This method will also enable researchers to distinguish differences in biodistribution that may arise from differences in charge, lipophilicity, etc. from those that may arise from loss of Cu-64 from the chelator. Last, this novel quantitative tool will allow investigators to evaluate the chemical factors that determine the in vivo stability of Cu-64 radiopharmaceuticals laying the groundwork for the future development of more effective Cu-64 radiopharmaceuticals. Once the feasibility of this method is established, it can also be used to evaluate the stability of other metalloradiopharmaceuticals including those based on Ga-68, a radionuclide that is showing great promise in tumor imaging.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

SUPPLEMENT: “THE RATE OF BINARY BLACK HOLE MERGERS INFERRED FROM ADVANCED LIGO OBSERVATIONS SURROUNDING GW150914” (2016, ApJL, 833, L1)

This article provides supplemental information for a Letter reporting the rate of (BBH) coalescences inferred from 16 days of coincident Advanced LIGO observations surrounding the transient (GW) signal GW150914. In that work we reported various rate estimates whose 90% confidence intervals fell in the range 2–600 Gpc{sup −3} yr{sup −1}. Here we give details on our method and computations, including information about our search pipelines, a derivation of our likelihood function for the analysis, a description of the astrophysical search trigger distribution expected from merging BBHs, details on our computational methods, a description of the effects and our model for calibration uncertainty, and an analytic method for estimating our detector sensitivity, which is calibrated to our measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

MPACT Fast Neutron Multiplicity System Prototype Development

This document serves as both an FY2103 End-of-Year and End-of-Project report on efforts that resulted in the design of a prototype fast neutron multiplicity counter leveraged upon the findings of previous project efforts. The prototype design includes 32 liquid scintillator detectors with cubic volumes 7.62 cm in dimension configured into 4 stacked rings of 8 detectors. Detector signal collection for the system is handled with a pair of Struck Innovative Systeme 16-channel digitizers controlled by in-house developed software with built-in multiplicity analysis algorithms. Initial testing and familiarization of the currently obtained prototype components is underway, however full prototype construction is required for further optimization. Monte Carlo models of the prototype system were performed to estimate die-away and efficiency values. Analysis of these models resulted in the development of a software package capable of determining the effects of nearest-neighbor rejection methods for elimination of detector cross talk. A parameter study was performed using previously developed analytical methods for the estimation of assay mass variance for use as a figure-of-merit for system performance. A software package was developed to automate these calculations and ensure accuracy. The results of the parameter study show that the prototype fast neutron multiplicity counter design is very nearly optimized under the restraints of the parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predictive Analytics for Hydropower Fleet Intelligence

A primary challenge in hydropower industry is the ability to maintain cost-competitiveness, reliability, and security of hydropower assets through evolving power system contexts and aging of the fleet. Maintaining cost-effective and reliable operations under these conditions is expected to require new modernization and maintenance paradigms for changing contexts. Changes in existing practices for O&M will require an understanding of the current state and health of hydropower assets, and the impact of changing paradigms on asset health and reliability. The Hydropower Fleet Intelligence project is developing and evaluating standardized methodologies and analysis tools for data-driven asset reliability and management technologies for hydropower, leading to eventual predictive maintenance planning, repair/replacement decision making, and asset-reliability and cost-optimized operations. A key question is the feasibility of using existing data sets at hydropower facilities to perform assessments of asset reliability. This document uses data from hydropower facilities to assess the potential for using available analytics methods for asset reliability estimates. In addition to reliability assessments, the feasibility of using existing analytics techniques for several other potential applications is discussed. Finally, a case study that a data-driven model is trained to learn nominal operations via vibration data from an asset of a certain plant, and then utilized to identify anomalies on a similar asset from a different plant, highlighting the generic use of proposed Prognostics and Health Management (PHM) approaches.

Yucesan, Yigit↗

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Engineering cellular metabolism for targeted biosynthesis can require extensive design-build-test-learn (DBTL) cycles as the engineer works around the cell's survival requirements. Alternatively, carrying out DBTL cycles in cell-free environments can accelerate this process and alleviate concerns with host compatibility. A promising approach to cell-free metabolic engineering (CFME) leverages metabolically active crude cell extracts as platforms for biomanufacturing and for rapidly discovering and prototyping modified proteins and pathways. Realizing these capabilities and optimizing CFME performance requires methods to characterize the metabolome of lysate-based cell-free platforms. That is, analytical tools are necessary for monitoring improvements in targeted metabolite conversions and in elucidating alterations to metabolite flux when manipulating lysate metabolism. In this work, metabolite analyses using high-performance liquid chromatography (HPLC) coupled with either optical or mass spectrometric detection were applied to characterize metabolite production and flux in E. coli S30 lysates. Specifically, this report describes the preparation of samples from CFME lysates for HPLC analyses using refractive index detection (RID) to quantify the generation of central metabolic intermediates and by-products in the conversion of low-cost substrates (i.e., glucose) to various high-value products. The analysis of metabolite conversion in CFME reactions fed with 13 C-labeled glucose through reversed-phase liquid chromatography coupled to tandem mass spectrometry (MS/MS), a powerful tool for characterizing specific metabolite yields and lysate metabolic flux from starting materials, is also presented. Altogether, applying these analytical methods to CFME lysate metabolism enables the advancement of these systems as alternative platforms for executing faster or novel metabolic engineering tasks.

59 BASIC BIOLOGICAL SCIENCES↗

Analytical calculation for the solid angle subtended at an arbitrarily positioned point source by an ellipse - Paper 38

The geometrical solid angle can be used to calibrate radiation detectors or to determine the activity of radioactive sources. In the present work, we introduce a direct analytical method for calculating the solid angle subtended at an arbitrarily positioned point source by a closed contour (ellipse). The validity of the derived analytical expressions was successfully confirmed by the comparison with some published data (Numerical Method). Direct mathematical expressions to calculate the geometrical solid angle subtended by an elliptical disk detector with respect to arbitrarily positioned radiating point sources have been derived. The agreement between the calculated and the published solid angle values is excellent; the discrepancies were (0.0%). This means that the present approach is efficient and sufficiently powerful to evaluate the geometrical efficiency of the elliptical disk detectors. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Pharmaceutical and Personal Care Compounds in Wastewater Sludge and Aqueous Samples using GC-MS/MS

The Bioenergy Program at Pacific Northwest National Laboratory (PNNL) is evaluating the feasibility of converting wastewater sludge materials to fuels. Wastewater sludge from various municipalities will be used in the evaluation process and as with any municipal waste, there is the potential for residual contaminates to remain in the sludge following wastewater treatment. Many surveys and studies have confirmed the presence of pharmaceuticals in municipal wastewater and effluents (World Health Organization, 2011). Determination of the presence and concentrations of the contaminants is required to define the proper handling of this sludge. A list of targeted compounds was acquired from the literature and an analytical method was developed for the pharmaceutical and personal care compounds. The presence of organics complicated the analytical techniques and, in some cases, the precision of the results. However, residual concentrations of a range of compounds were detected in the wastewater sludge and the presence and concentrations of these compounds will be considered in identifying the appropriate handling of this material in conduct of research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Environmental Swipe (ES) Streamline Protocol—ORNL Testing Fiscal Year 2016 Report

As a sub-section of the NA241 project entitled “Faster, Simpler, Lower-Cost Laboratory Analysis of Environmental Samples,” Oak Ridge National Laboratory (ORNL) was to function as a Network Analytical Laboratory (NWAL) for validation, verification, and review of analytical methods developed under the auspices of this project. ORNL would also provide technical input on alternative analytical protocols for analyzing bulk environmental samples submitted for uranium (U) and/or plutonium (Pu) determinations by the International Atomic Energy Agency (IAEA). The final ORNL task would then be to summarize findings as stated in this end-of year report.

54 ENVIRONMENTAL SCIENCES↗

Defining the Difference Between Laboratory and Field-Generated Foamed Cement

Foamed cement has been used extensively across a variety of applications for oil and gas well cementing, including deepwater riserless cementing, low fracture gradient cementing, horizontal well cementing, steam injection well cementing, and high-pressure/high-temperature (HP/HT) cementing. When using foamed cement, laboratory testing is used to estimate the performance characteristics of foamed cement slurries that are designed for well applications. It is well known that significant differences exist between the methods used to generate foamed cement in the laboratory and those used to generate foamed cement for field applications. The implications of these differences on foamed slurry characteristics (e.g., bubble size distribution) and performance properties (e.g., stability, permeability, mechanical properties) has not been well analyzed or well understood. This paper documents a project that was undertaken through a joint effort between API Sub-Committee 10 and the National Energy Technology Laboratory (NETL) to examine the differences between foamed slurries generated with laboratory equipment and field foamed cementing equipment. Methods for generating and capturing foamed cement samples using field equipment are discussed, as well as analytical methods for evaluating the characteristics of foamed cements. References to the resulting data are provided. Finally, conclusions and recommendations are presented that were developed during the course of the project.

02 PETROLEUM↗

Progress report on analytic and numerical studies of x-ray-induced impulse

In a variety of high-energy-density (HED) systems, x-rays of a given energy are used to generate shockwaves, bulk motion, and impulse in materials. As radiation energy is deposited within the material, the material is heated. The number of photons of a certain wavelength absorbed is determined by the spectral intensity of the radiation and the material’s opacity evaluated at that wavelength. This heating results in a pressure increase dictated by the material’s equation of state. Depending on the intensity of the absorbed radiation, it may also cause the material to change phase into a liquid, gas, or plasma. The increased pressure drives the heated surface layer to blow off, imparting impulse and sending a compressive wave into the bulk of the material. Additionally, the compression wave interacts with the solid boundary of the material, resulting in a tensile wave that may cause the material to spall. The impulse generated by the deposition of x-ray energy within the sample can be modeled using purely analytical methods, e.g. the Bethe, Bade, Averell, and Yost (BBAY) model. However, the blow-off process is rather complicated, and proper modeling efforts must account for material ejected by spallation, vaporization, jetting, and plasma ablation. For this reason, analytical models have an unclosed term describing the final energy of the blown-off material Ef(z). Prior modeling efforts have arbitrarily fixed this at some value or modeled it using a limiting set of thermodynamic assumptions. The work we are currently performing uses validated simulations using sophisticated photon transport, equation of state, and strength models/data to provide a fit for Ef(z) that is useful for predictive calculation of impulse. We will apply our methodology and show results for different materials and x-ray sources. This work is particularly useful for the design of experiments studying x-ray impulse generation. The present report is outlined as follows. Section 1.2 describes a series of HED experiments investigating x-ray-generated impulse in materials. Section 1.3 describes the computational approach we employ in this study, and presents validation results against the aforementioned experiments. Section 1.4 introduces analytical models for impulse generation, as well as our method for utilizing impulse from simulations to close the models. We discuss the concept of impulse-spectrum sensitivity, it’s application to uncertainty quantification, and derive a very useful analytical expression for it in 1.5. We then summarize recent progress in this project and discuss future work in section 1.6.

36 MATERIALS SCIENCE↗

Mixture-process variable approach to optimize a microemulsion electrokinetic chromatography method for the quality control of a nutraceutical based on coenzyme Q10

In recent years, multivariate optimization has played an increasing role in analytical method development. ICH guidelines recommend using statistical design of experiments to identify the design space, in which multivariate combinations of composition variables and process variables have been demonstrated to provide quality results. Considering a microemulsion electrokinetic chromatography method (MEEKC), the performance of the electrophoretic run depends on the proportions of mixture components (MCs) of the microemulsion and on the values of process variables (PVs). In the present work, for the first time in the literature, a mixture-process variable (MPV) approach was applied to optimize a MEEKC method for the analysis of coenzyme Q10 (Q10), ascorbic acid (AA), and folic acid (FA) contained in nutraceuticals. The MCs (buffer, surfactant-cosurfactant, oil) and the PVs (voltage, buffer concentration, buffer pH) were simultaneously changed according to a MPV experimental design. A 62-run MPV design was generated using the I-optimality criterion, assuming a 46-term MPV model allowing for special-cubic blending of the MCs, quadratic effects of the PVs, and some MC-PV interactions. The obtained data were used to develop MPV models that express the performance of an electrophoretic run (measured as peak efficiencies of Q10, AA, and FA) in terms of the MCs and PVs. Contour and perturbation plots were drawn for each of the responses. Finally, the MPV models and criteria for the peak efficiencies were used to develop the design space and an optimal subregion (i.e., the settings of the mixture MCs and PVs that satisfy the respective criteria), as well as a unique optimal combination of MCs and PVs.

Coenzyme Q10↗

Computational Approach in Determination of {sup 233}U and {sup 233}Th Fermi Energy

There are several methods to get Fermi energy such as hermit polynomial expansion and Wigner-Kirkwood expansion, these are analytical method. In this paper will be discussed numerical approach of calculating Fermi energy of {sup 233}Th and {sup 233}U nuclei. Our work demonstrates the simple technique of determining Fermi energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method for estimating optimal spectral and energy parameters of laser irradiation in photodynamic therapy of biological tissue

We have solved the problem of layer-by-layer laser-light dosimetry in biological tissues and of selecting an individual therapeutic dose in laser therapy. A method is proposed for real-time monitoring of the radiation density in tissue layers in vivo, concentrations of its endogenous (natural) and exogenous (specially administered) chromophores, as well as in-depth distributions of the spectrum of light action on these chromophores. As the background information use is made of the spectrum of diffuse light reflected from a patient's tissue, measured by a fibre-optic spectrophotometer. The measured spectrum is quantitatively analysed by the method of approximating functions for fluxes of light multiply scattered in tissue and by a semi-analytical method for calculating the in-depth distribution of the light flux in a multi-layered medium. We have shown the possibility of employing the developed method for monitoring photosensitizer and oxyhaemoglobin concentrations in tissue, light power absorbed by chromophores in tissue layers at different depths and laser-induced changes in the tissue morphology (vascular volume content and ratios of various forms of haemoglobin) during photodynamic therapy. (biophotonics)

60 APPLIED LIFE SCIENCES↗