Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AORTA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Reproducibility of Abdominal Aortic Aneurysm Diameter Measurement and Growth Evaluation on Axial and Multiplanar Computed Tomography Reformations

Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: Dmax, as measured on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001-0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662-0.780) and single-plane MPR images (0.772-0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fenestrated Thoracic Endovascular Aortic Repair Using Physician-Modified Stent Grafts (PMSGs) in Zone 0 and Zone 1 for Aortic Arch Diseases

Purpose: To evaluate the outcomes of fenestrated thoracic endovascular aortic repair (f-TEVAR) using physician-modified stent grafts (PMSGs) in zone 0 and zone 1 for aortic arch diseases. Methods: f-TEVAR using PMSGs in Z0 and Z1 was performed on ten high-risk patients for open surgery from November 2015 to September 2017. Indications were complicated acute type B dissection (ABAD) with retrograde dissection involving the mid-arch (n = 1), distal arch aneurysms (n = 3), mid-arch aneurysms of the inner arch curvature (n = 3) and penetrating aortic ulcer located in the mid- or proximal arch (n = 3). Pre-, intra- and postoperative clinical data were recorded. Results: The median patient age was 61 (range 45–81) years, and 9 (90%) patients were men. Ten PMSGs (Medtronic Valiant stent grafts, n = 1; Relay thoracic stent grafts, n = 4; Cook TX2 device, n = 5) were deployed. PMSGs were deployed from Z0 and Z1 in 5 and 5 patients, respectively. Double small fenestrations for the left subclavian artery (LSA) and the left common carotid artery (LCCA), respectively, were created in 3 patients. Triple small fenestrations for the innominate artery (IA), the LCCA and the LSA, respectively, were created in 2 patients. One large fenestration for both the IA and the LCCA combined with one small fenestration for the LSA was created in 3 patients. One large fenestration for the LCCA combined with one small fenestration for the LSA was created in 2 patients. Posterior diameter-reducing ties were added to all the devices except to one Valiant stent graft. All but 2 patients underwent elective procedure. Median duration for stent graft modifications was 105 (range 90–125) min. The technical success rate was 90%. Overall mortality was 10% (1/10). One patient died of sudden cardiac arrest intraoperatively after the deployment of the PMSG and all the supra-aortic branch stents. Mean operative time was 106.0 ± 43.0 min, and fluoroscopy time was 30.6 ± 22.9 min. There were no type I or type III endoleaks, perioperative neurological complications or spinal cord ischemia. Median length of stay was 8 (range 4–35) days. Nine patients survived at mean 13.3 (range 6.0–19.0) months follow-up. Retrograde dissection occurred in one patient of Z0 group 40 days post-f-TEVAR and resolved after open repair. During follow-up, all target vessels remained patent without fenestration-related type I or III endoleaks. Conclusions: f-TEVAR using PMSGs in Z0 and Z1 for the treatment of aortic arch diseases in high-risk patients is feasible in the hands of experienced operators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unusual Access for the Treatment of Iliac Artery Aneurysm in Association with Type II Endoleak After Endovascular Repair of an Aortoiliac Aneurysm

Internal iliac artery aneurysms (IIAAs), although rare, are associated with a significant risk of mortality, if they rupture. Endovascular approach with exclusion of the aneurysm sac from antegrade and retrograde perfusion is proved to be a feasible treatment option. However, this option is not always technically possible with a preexisting endovascular aneurysm repair (EVAR) or surgical aortoiliac reconstruction with ligation of internal iliac artery origin. We report another safe treatment option of an enlarging IIAA associated with a type II endoleak after EVAR and a standard endovascular treatment was not possible. The access to the aneurysm sac was achieved retrograde via percutaneous access to the superior gluteal artery under fluoroscopy followed by treatment with embolization of the inflow and outflow vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Penetrating Aortic Ulcer and Intramural Hematoma

Acute aortic syndromes include a variety of overlapping clinical and anatomic diseases. Penetrating aortic ulcer (PAU), intramural hematoma (IMH) and aortic dissection can occur as isolated processes or can be found in association. All these entities are potentially life threatening, so prompt diagnosis and treatment is of paramount importance. PAU and IMH lesions in the Stanford Type A distribution often require urgent open surgical repair. Lesions in the Stanford Type B distribution may be managed medically in the absence of symptoms or progression; however, a low threshold for endovascular or surgical treatment should be maintained. This review summarizes the clinical presentation, epidemiology, diagnosis, indications for treatment and endovascular strategies in patients with PAU or IMH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Catheter-Directed Fenestration for Branch Vessel Reconnection in Aortic Dissection Using a Novel Diamond-Tipped Chronic Total Occlusion Drilling Device: A Technical Report

Purpose: Aortic dissection is a complex condition with high morbidity and mortality. Endovascular treatments including percutaneous fenestration can be used to manage branch vessel ischaemia or risk of aortic rupture. A variety of techniques for aortic fenestration have been described. We describe the novel use of the TruePath Chronic Total Occlusion (CTO) device for aortic intimal fenestration to achieve side branch reconnection. Materials and Methods: We present three cases of aortic dissection presenting with symptoms of aortic side branch occlusion and end organ malperfusion, treated with aortic fenestration using the TruePath CTO device via trans-brachial and trans-femoral approaches. Results: Technical success was achieved in all three cases. No complications were encountered. Flow was restored in compromised visceral branches. Branches remained patent on follow-up CT angiography over a minimum 2.5-year follow-up period. Conclusion: Percutaneous aortic fenestration techniques enable a minimally invasive approach to treat visceral branch malperfusion associated with aortic dissection. The TruePath CTO device improves the control of the fenestration procedure with the potential to improve efficacy and safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Type II Endoleak After Endovascular Aortic Aneurysm Repair Using the Endurant Stent Graft System for Abdominal Aortic Aneurysm with Occluded Inferior Mesenteric Artery

Purpose: To evaluate the incidence of type II endoleak (EL-II) and aneurysm enlargement after endovascular aneurysm repair (EVAR) using the Endurant stent graft in patients with abdominal aortic aneurysm (AAA) with occluded inferior mesenteric artery (IMA). Materials and Methods: Between 2012 and 2017, 103 patients who underwent EVAR using the Endurant stent graft for AAA with occluded IMA (50 patients with prophylactic embolized IMA and 53 with spontaneous occluded IMA) were retrospectively reviewed. The incidence of EL-II and aneurysm enlargement was evaluated. Predictive factors for persistent EL-II were evaluated based on patient characteristics, preprocedural anatomical characteristics, intraprocedural details, and postprocedural complications. Results: Incidence rates of early EL-II and persistent EL-II were 6.8% (7/103 patients) and 4.9% (5/103 patients), respectively. Aneurysm enlargement was found in 10 patients (9.7%), including all 5 patients with persistent EL-II, 3 with de novo EL-II, and 2 with no EL-II. The rates of freedom from aneurysm enlargement at 1, 2, and 3 years were 98.7%, 97.0%, and 93.1% for the group without persistent EL-II, and 80.0%, 60.0%, and 20.0% for the group with persistent EL-II (p < 0.001), respectively. The maximum aneurysm diameter (odds ratio (OR), 1.16; 95% confidence interval (CI), 1.01–1.34; p = 0.0362) and the number of patent lumbar arteries (OR, 2.72; 95% CI, 1.07–6.90; p = 0.0357) were predictive of persistent EL-II. Conclusions: The incidence of EL-II after EVAR using the Endurant stent graft for AAA with occluded IMA was low, but most early EL-II persisted and resulted in aneurysm enlargement. Level of Evidence Level 4, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transgraft sac Embolization Combined with Graft Reinforcement for Refractory Mixed-Type Endoleak

An 80-year-old female underwent EVAR 4 years ago. She presented type II endoleak with sac expansion from 68 to 80 mm during 3-year follow-up after EVAR. Although she underwent translumbar percutaneous sac embolization, the AAA sac continued to enlarge, suggesting mixed-type endoleak including type I, II, and III. Transgraft direct sac angiography revealed endoleak cavity without demonstrable feeding vessel. Transgraft sac embolization using n-butyl cyanoacrylate and graft reinforcement was performed concurrently, without complications. The graft reinforcement consisted of graft extension for eliminating occult type I endoleak, and relining for eliminating occult type III endoleak. Six months after the procedure, CT showed no signs of sac expansion. Transgraft sac embolization combined with graft reinforcement is one of the available options for persistent and refractory mixed-type endoleak.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Imaging to Guide Thoracic Endovascular Aortic Repair (TEVAR): A Randomized Comparison of Two Methods, 2D/3D Versus 3D/3D Image Fusion

Purpose: To compare the accuracy of two-dimensional (2D) versus three-dimensional (3D) image fusion for thoracic endovascular aortic repair (TEVAR) image guidance. Materials and Methods: Between December 2016 and March 2018, all eligible patients who underwent TEVAR were prospectively included in a single-center study. Image fusion methods (2D/3D or 3D/3D) were randomly assigned to guide each TEVAR and compared in terms of accuracy, dose area product (DAP), volume of contrast medium injected, fluoroscopy time and procedure time. Results: Thirty-two patients were prospectively included; 18 underwent 2D/3D and 14 underwent 3D/3D TEVAR. The 3D/3D method allowed more accurate positioning of the aortic mask on top of the fluoroscopic images (proximal landing zone error vector: 1.7 ± 3.3 mm) than was achieved by the 2D/3D method (6.1 ± 6.1 mm; p = 0.03). The 3D/3D image fusion method was associated with significantly lower DAP than the 2D/3D method (50.5 ± 30.1 Gy cm{sup 2} for 3D/3D vs. 99.5 ± 79.1 Gy cm{sup 2} for 2D/3D; p = 0.03). The volume of contrast medium injected was significantly lower for the 3D/3D method than for the 2D/3D method (50.6 ± 22.9 ml vs. 98.4 ± 47.9 ml; p = 0.002). Conclusion: Higher image fusion accuracy and lower contrast volume and irradiation dose were observed for 3D/3D image fusion than for 2D/3D during TEVAR. Level of Evidence: II, Randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fetal liver stromal cells promote hematopoietic cell expansion

Future application of hematopoietic stem and progenitor cells (HSPCs) in clinical therapies largely depends on their successful expansion in vitro. Fetal liver (FL) is a unique hematopoietic organ in which hematopoietic cells markedly expand in number, but the mechanisms involved remain unclear. Stromal cells (StroCs) have been suggested to provide a suitable cellular environment for in vitro expansion of HSPCs. In this study, murine StroCs derived from FL at E14.5, with a high level of Sonic hedgehog (Shh) and Wnt expression, were found to have an increased ability to support the proliferation of HSPCs. This effect was inhibited by blocking Shh signaling. Supplementation with soluble Shh-N promoted the proliferation of hematopoietic cells by activating Wnt signaling. Our findings suggest that FL-derived StroCs support proliferation of HSPCs via Shh inducing an autocrine Wnt signaling loop. The use of FL-derived StroCs and regulation of the Shh pathway might further enhance HPSC expansion.

60 APPLIED LIFE SCIENCES↗

Transcription factor COUP-TFII is indispensable for venous and lymphatic development in zebrafish and Xenopus laevis

Highlights: {yields} COUP-TFII deficiency in zebrafish affects arterio-venous EC specification. {yields} COUP-TFII is indispensable for lymphatic development in zebrafish. {yields} COUP-TFII knockdown in Xenopus disrupts lymphatic EC differentiation and migration. {yields} COUP-TFII's role in EC fate decisions is evolutionary conserved. -- Abstract: Transcription factors play a central role in cell fate determination. Gene targeting in mice revealed that Chicken Ovalbumin Upstream Promoter-Transcription Factor II (COUP-TFII, also known as Nuclear Receptor 2F2 or NR2F2) induces a venous phenotype in endothelial cells (ECs). More recently, NR2F2 was shown to be required for initiating the expression of Prox1, responsible for lymphatic commitment of venous ECs. Small animal models like zebrafish embryos and Xenopus laevis tadpoles have been very useful to elucidate mechanisms of (lymph) vascular development. Therefore, the role of NR2F2 in (lymph) vascular development was studied by eliminating its expression in these models. Like in mice, absence of NR2F2 in zebrafish resulted in distinct vascular defects including loss of venous marker expression, major trunk vessel fusion and vascular leakage. Both in zebrafish and Xenopus the development of the main lymphatic structures was severely hampered. NR2F2 knockdown significantly decreased prox1 expression in zebrafish ECs and the same manipulation affected lymphatic (L)EC commitment, migration and function in Xenopus tadpoles. Therefore, the role of NR2F2 in EC fate determination is evolutionary conserved.

60 APPLIED LIFE SCIENCES↗

Efficient production of platelets from mouse embryonic stem cells by enforced expression of Gata2 in late hemogenic endothelial cells

Platelets are essential for blood circulation and coagulation. Previous study indicated that overexpression of Gata2 in differentiated mouse embryonic stem cells (ESCs) resulted in robust induction of megakaryocytes (Mks). To evaluate platelet production capacity of the Gata2-induced ESC-derived Mks, we generated iGata2-ESC line carrying the doxycycline-inducible Gata2 expression cassette. When doxycycline was added to day 5 hemogenic endothelial cells in the in vitro differentiation culture of iGata2-ESCs, c-Kit{sup −}Tie2{sup −}CD41{sup +} Mks were predominantly generated. These iGata2-ESC-derived Mks efficiently produced CD41{sup +}CD42b{sup +}CD61{sup +} platelets and adhered to fibrinogen-coated glass coverslips in response to thrombin stimulation. Transmission electron microscopy analysis demonstrated that the iGata2-ESC-derived platelets were discoid-shaped with α-granules and an open canalicular system, but were larger than peripheral blood platelets in size. These results demonstrated that an enforced expression of Gata2 in late HECs of differentiated ESCs efficiently promotes megakaryopoiesis followed by platelet production. This study provides valuable information for ex vivo platelet production from human pluripotent stem cells in future. -- Highlights: •Megakaryocytes are efficiently induced by Gata2 from ESC-derived day 5 HECs. •Gata2-induced ESC-derived megakaryocytes are c-Kit{sup −}Tie2{sup −}CD41{sup +}. •Gata2-induced ESC-derived megakaryocytes produce larger discoid-shaped platelets. •Gata2-induced ESC-derived platelets bind fibrinogen upon thrombin stimulation.

60 APPLIED LIFE SCIENCES↗

Radiation Dose-Volume Effects and the Penile Bulb

The dose, volume, and clinical outcome data for penile bulb are reviewed for patients treated with external-beam radiotherapy. Most, but not all, studies find an association between impotence and dosimetric parameters (e.g., threshold doses) and clinical factors (e.g., age, comorbid diseases). According to the data available, it is prudent to keep the mean dose to 95% of the penile bulb volume to <50 Gy. It may also be prudent to limit the D70 and D90 to 70 Gy and 50 Gy, respectively, but coverage of the planning target volume should not be compromised. It is acknowledged that the penile bulb may not be the critical component of the erectile apparatus, but it seems to be a surrogate for yet to be determined structure(s) critical for erectile function for at least some techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential in vitro effects of carbon nanotubes on human aortic endothelial cells

Respiratory exposure of mice to carbon nanotubes induces pulmonary toxicity and adverse cardiovascular effects associated with atherosclerosis. We hypothesize that the direct contact of carbon nanotubes with endothelial cells will result in dose-dependent effects related to altered cell function and cytotoxicity which may play a role in potential adverse pulmonary and cardiovascular outcomes. To test this hypothesis, we examined the effects of purified single- and multi-walled carbon nanotubes (SWCNT and MWCNT) on human aortic endothelial cells by evaluating actin filament integrity and VE-cadherin distribution by fluorescence microscopy, membrane permeability by measuring the lactate dehydrogenase (LDH) release, proliferation/viability by WST-1 assay, and overall functionality by tubule formation assay. Marked actin filament and VE-cadherin disruption, cytotoxicity, and reduced tubule formation occurred consistently at 24 h post-exposure to the highest concentrations [50-150 {mu}g/10{sup 6} cells (1.5-4.5 {mu}g/ml)] for both SWCNT and MWCNT tested in our studies. These effects were not observed with carbon black exposure and carbon nanotube exposure in lower concentrations [1-10 {mu}g/10{sup 6} cells (0.04-0.4 {mu}g/ml)] or in any tested concentrations at 3 h post-exposure. Overall, the results indicate that SWCNT and MWCNT exposure induce direct effects on endothelial cells in a dose-dependent manner.

60 APPLIED LIFE SCIENCES↗