Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Theoretical study of photoelectron angular distributions in single-photon ionization of aligned N{sub 2} and CO{sub 2}

We calculate photoelectron angular distributions (PADs) resulting from single-photon (43 eV) ionization of molecules that have been transiently aligned with a short laser pulse. The total ionization cross sections of N{sub 2} and CO{sub 2} vs the time delay between the aligning laser pulse and the soft x-ray photon are calculated and compared to experimental results reported by I. Thomann et al. [J. Phys. Chem. A 112, 9382 (2008)]. We present the PADs from these aligned molecules in the laboratory frame which can be compared directly with future experiments from aligned N{sub 2} and CO{sub 2}. The alignment dependence of single-photon ionization, multiphoton ionization, and high-order harmonic generation are also analyzed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Two-center minima in harmonic spectra from aligned polar molecules

We extend a model of two-center interference to include the superposition of opposite orientations in aligned polar molecules. We show that the position of the minimum in the harmonic spectrum from both aligned and oriented CO depends strongly on the relative recombination strength at different atoms, not just the relative phase. We reinterpret the minimum in aligned CO as an interference between opposite orientations, and obtain good agreement with numerical calculations. Inclusion of the first-order Stark effect shifts the position of the interference minimum in aligned CO even though aligned molecules do not posses total permanent dipoles. We explain the shift in terms of the phase that the electron of oriented CO accumulates due to the Stark effect.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-spin proton alignments and coexisting coupling schemes in {sup 168}Hf

High-spin states in {sup 168}Hf were populated in the {sup 96}Zr({sup 76}Ge,4n) reaction and the decay {gamma} rays measured with the Gammasphere spectrometer array. Previously known bands were extended to significantly higher spins and seven new bands were established. The results were interpreted within the framework of the cranked shell model with the help of comparisons with neighboring nuclei. The observation of full alignment in band crossings at a rotational frequency ({Dirac_h}/2{pi}){omega}{approx}0.55 MeV revealed that these crossings are associated with proton alignments involving h{sub 11/2} and h{sub 9/2} orbitals. The characteristics of one strongly coupled high-K band indicate that the deformation-aligned configuration is built on the same six quasiparticles that constitute the high-spin structure of a rotationally aligned band. This leads to the coexistence of two coupling schemes, deformation and rotation alignment, in six-quasiparticle structures involving the same orbitals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gravitational-wave detectability of equal-mass black-hole binaries with aligned spins

Binary black-hole systems with spins aligned or anti-aligned to the orbital angular momentum, and which therefore do not exhibit precession effects, provide the natural ground to start detailed studies of the influence of strong-field spin effects on gravitational-wave observations of coalescing binaries. Furthermore, such systems may be the preferred end state of the inspiral of generic supermassive binary black-hole systems. In view of this, we have computed the inspiral and merger of a large set of binary systems of equal-mass black holes with spins parallel to the orbital angular momentum but otherwise arbitrary. Our attention is particularly focused on the gravitational-wave emission so as to quantify how much spin effects contribute to the signal-to-noise ratio, to the horizon distances, and to the relative event rates for the representative ranges in masses and detectors. As expected, the signal-to-noise ratio increases with the projection of the total black-hole spin in the direction of the orbital momentum. We find that equal-spin binaries with maximum spin aligned with the orbital angular momentum are more than '3 times as loud' as the corresponding binaries with anti-aligned spins, thus corresponding to event rates up to 30 times larger. We also consider the waveform mismatch between the different spinning configurations and find that, within our numerical accuracy, binaries with opposite spins S{sub 1}=-S{sub 2} cannot be distinguished, whereas binaries with spin S{sub 1}=S{sub 2} have clearly distinct gravitational-wave emissions. Finally, we derive a simple expression for the energy radiated in gravitational waves and find that the binaries always have efficiencies E{sub rad}/M > or approx. 3.6%, which can become as large as E{sub rad}/M{approx_equal}10% for maximally spinning binaries with spins aligned with the orbital angular momentum. These binaries are therefore among the most efficient sources of energy in the Universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kinetic Alfven wave instability driven by a field-aligned current in high-{beta} plasmas

Including the ion-gyroradius effect, a general low-frequency kinetic dispersion equation is presented, which simultaneously takes account of a field-aligned current and temperature anisotropy in plasmas. Based on this dispersion equation, kinetic Alfven wave (KAW) instability driven by the field-aligned current, which is carried by the field-aligned drift of electrons relative to ions at a drift velocity V{sub D}, is investigated in a high-{beta} plasma, where {beta} is the kinetic-to-magnetic pressure ratio in the plasma. The numerical results show that the KAW instability driven by the field-aligned current has a nonzero growth rate in the parallel wave-number range 0<k{sub z}<k{sub z}{sup u}, where the growth rate reaches a maximum at k{sub z}{approx}k{sub z}{sup u}/2. On the other hand, in the perpendicular wave-number range 0<k{sub perpendicular}<k{sub perpendicular}{sup u} the growth rate monotonously decreases with the wave number k{sub perpendicular} from a maximum at k{sub perpendicular}=0 to zero at k{sub perpendicular}=k{sub perpendicular}{sup u}. In particular, the upper boundaries of the growing ranges in the wave-number space, k{sub z}{sup u} and k{sub perpendicular}{sup u}, as well as the growth rate increase with V{sub D}, imply that there are wider growing ranges and larger growth rate for larger drift velocities. Including the temperature anisotropy of plasma particles, the result shows that the instability conditions for these two driven mechanisms are both modified considerably, in which the growing parametric ranges of KAWs widen. The results have potential importance in understanding the physics of space and astrophysical plasma active phenomena since the field-aligned current, also called the Birkeland current, is one of the most active factors in plasma phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-Resolved Electron Diffraction from Selectively Aligned Molecules

We experimentally demonstrate ultrafast electron diffraction from transiently aligned molecules in the absence of external (aligning) fields. A sample of aligned molecules is generated through photodissociation with femtosecond laser pulses, and the diffraction pattern is captured by probing the sample with picosecond electron pulses shortly after dissociation - before molecular rotation causes the alignment to vanish. In our experiments the alignment decays with a time constant of 2.6{+-}1.2 ps.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work, two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-J-181: An Alternative Patient Alignment Tool On TomoTherapy: The First In- Human Megavoltage-Topogram Acquisition

Purpose: To show the first in-human Megavoltage (MV)-Topogram acquisition for the evaluation of the potential for MV-Topogram-based alignment as an alternative to MVCT for reducing dose and imaging time. Methods: A lung cancer patient was enrolled in an ongoing IRB-approved clinical trial at our institute. The patient was set up using the clinical protocol employing positioning lasers. 3.2mm diameter tungsten spheres were placed on the patient’s skin at their alignment tattoos to check surface-based marker concordance between topograms and MVCT. Anterior-Posterior (AP) and lateral (LAT) MV-Topograms were acquired using gantry angles of 0°/90° with a 1mm collimator opening, all MLC leafs open, 4cm/s couch speed, and 12.5s scanning time. The topogram acquisition was immediately followed by the normal MVCT scan acquisition. MV-Topograms were reconstructed from the detector exit-data using in-house developed software. The topograms were also enhanced using contrast-limited adaptive histogram equalization (CLAHE). The MV-Topograms were registered to reference kV-based digitally reconstructed topograms. The localization results were compared against results obtained comparing the clinical MVCT to the kVCT simulation. Results: The shifts using the unenhanced Topograms, enhanced Topograms, and MVCT were (LAT, LONG, VERT, ROLL) (5.8mm, 2.6mm, −5.6mm, 0.34°), (3.9mm, 2.5mm, −2.2mm, 0.65°) and (2.4mm, 1.5mm, −3.0mm, 0.5°), respectively. The magnitude alignment differences between the enhanced Topograms and MVCT were within 1.5 mm and 0.15°. The average MVCT and total Topogram acquisition times were 272.9s ± 31.5s and 46s, respectively. Conclusion: MV-Topograms have the potential for providing equivalent performance with less dose and acquisition time than the traditional MVCT technique. We are evaluating other sites as well as adding patients to develop statistically significant analyses regarding the alignment quality differences. MV-Topograms are likely to be most clinically useful for bony anatomy and radiopaque marker-based alignments. The study was supported by an Accuray Grant.

60 APPLIED LIFE SCIENCES↗

Alignment of the ATLAS Inner Detector in Run 2

The performance of the ATLAS Inner Detector alignment has been studied using pp collision data at s√=13TeV collected by the ATLAS experiment during Run 2 (2015–2018) of the Large Hadron Collider (LHC). The goal of the detector alignment is to determine the detector geometry as accurately as possible and correct for time-dependent movements. The Inner Detector alignment is based on the minimization of track-hit residuals in a sequence of hierarchical levels, from global mechanical assembly structures to local sensors. Subsequent levels have increasing numbers of degrees of freedom; in total there are almost 750,000. The alignment determines detector geometry on both short and long timescales, where short timescales describe movements within an LHC fill. The performance and possible track parameter biases originating from systematic detector deformations are evaluated. Momentum biases are studied using resonances decaying to muons or to electrons. The residual sagitta bias and momentum scale bias after alignment are reduced to less than ~0.1 TeV -1 and 0.9×10 -3 , respectively. Impact parameter biases are also evaluated using tracks within jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determining tolerance requirements for spray-duct alignment in ducted fuel injection

Several ducted fuel injection (DFI) studies have highlighted the importance of accuracy in aligning the duct axis with that of its corresponding spray for optimal effectiveness, as misalignment adversely impacts the method’s performance. The need for accurate alignment could lead to added manufacturing complexity via tighter tolerances. This study systematically explores cases of horizontal, vertical, and rotational misalignment, analyzing their respective effects on DFI performance. Vertical and horizontal misalignments at the duct inlet plane were varied at magnitudes of 6.25%, 12.5%, and 25.0% of the duct diameter, corresponding to 0.125, 0.25, and 0.5 mm, respectively. Rotational misalignments were set at 1°, 2°, and 4°, corresponding to 3.65%, 7.30%, and 14.6%, respectively, of the duct diameter at its inlet plane. The investigation yields spray-duct alignment tolerance limits and highlights the influence of misalignment direction on emissions due to the interactions with swirl and squish inside the combustion chamber. The results indicate that the tolerance limits for the alignment are within 4° and 0.5 mm relative to the geometrically aligned position. If the misalignment exceeds 4°of rotation or 0.5 mm in the horizontal direction, the beneficial effects on soot reduction using this method are no longer observed. The findings contribute to an understanding that can be used to optimize DFI for cleaner and more efficient combustion in compression-ignition engines.

Şener, Ramazan↗

Design and alignment of an all-spherical unobscured four-mirror image relay for an ultra-broadband sub-petawatt laser

We describe the design and alignment of an unobscured reflective image relay for use in an ultra-broadband half-petawatt laser system in development at the University of Rochester’s Laboratory for Laser Energetics. The design consists of four spherical mirrors in an unobscured configuration. We show the theoretical basis for such a four-mirror design using first-order optical matrix methods and nodal aberration theory. We also describe the process of aligning this design in a test bed and show the results of this alignment method. We were able to achieve a diffraction-limited nominal design. Furthermore, upon aligning the design in our test bed, we were able to successfully align the design to achieve our target wavefront error of less than 0.3 waves p–v and 0.07 waves rms at the central laser-operating wavelength of 910 nm.

47 OTHER INSTRUMENTATION↗

Joint iterative reconstruction and 3D rigid alignment for X-ray tomography

X-ray tomography is widely used for three-dimensional structure determination in many areas of science, from the millimeter to the nanometer scale. The resolution and quality of the 3D reconstruction is limited by the availability of alignment parameters that correct for the mechanical shifts of the sample or sample stage for the images that constitute a scan. In this paper we describe an algorithm for marker-free, fully automated and accurately aligned and reconstructed X-ray tomography data. Our approach solves the tomographic reconstruction jointly with projection data alignment based on a rigid-body deformation model. We demonstrate the robustness of our method on both synthetic phantom and experimental data and show that our method is highly efficient in recovering relatively large alignment errors without prior knowledge of a low resolution approximation of the 3D structure or a reasonable estimate of alignment parameters.

36 MATERIALS SCIENCE↗

NSLS-II Booster Survey and Alignment Systems

This section outlines the survey and alignment requirements and the technology and tools for achieving the NSLS-II equipment positioning goals. The required alignment tolerances are defined primarily by the physics requirements of the accelerator. The tight tolerances dictated by the physics requirements are an order of magnitude tighter than the tolerances of second generation light sources (NSLS) and on level with those at third generation light sources (Soleil, Diamond). These extraordinary position requirements necessitate a concerted R&D engineering effort to identify and develop the survey methodology needed to meet these requirements. As of this date, the methodology is still evolving to balance cost and time constraints while still maintaining the integrity of the survey and alignment systems. State-of-the art equipment including Laser Trackers and Laser Arms have been purchased and used extensively in the pursuit of meeting the NSLS-II survey tolerances. No new technology will need to be developed to meet the alignment requirements but new techniques will be pursued and developed. Survey and alignment provides the foundation for positioning the beam-guiding magnet structures in all 6 degrees of freedom within the required tolerances. Although the tools and instrumentation available for this task have changed over the years and faster and more accurate measurements are possible, only limited control of the environmental conditions is possible. This ultimately sets an upper limit for the achievable measurement and subsequent control network accuracy. At the same time, the control of environmental variables (temperature, humidity) will be fully taken advantage of during the building of NSLS-II , opening up the possibility of ever-increasing accuracy unheard of only five years ago.

42 ENGINEERING↗

New alignment method for remote protein sequences by the direct use of pairwise sequence correlations and substitutions

Understanding protein sequences and how they relate to the functions of proteins is extremely important. One of the most basic operations in bioinformatics is sequence alignment and usually the first things learned from these are which positions are the most conserved and often these are critical parts of the structure, such as enzyme active site residues. In addition, the contact pairs in a protein usually correspond closely to the correlations between residue positions in the multiple sequence alignment, and these usually change in a systematic and coordinated way, if one position changes then the other member of the pair also changes to compensate. In the present work, these correlated pairs are taken as anchor points for a new type of sequence alignment. The main advantage of the method here is its combining the remote homolog detection from our method PROST with pairwise sequence substitutions in the rigorous method from Kleinjung et al. We show a few examples of some resulting sequence alignments, and how they can lead to improvements in alignments for function, even for a disordered protein.

Jia, Kejue↗

Mechanical and Dielectric Properties of Aligned Electrospun Fibers

This review paper examines the current state-of-the-art in fabrication of aligned fibers via electrospinning techniques and the effects of these techniques on the mechanical and dielectric properties of electrospun fibers. Molecular orientation, system configuration to align fibers, and post-drawing treatment, like hot/cold drawing process, contribute to better specific strength and specific stiffness properties of nanofibers. The authors suggest that these improved, aligned nanofibers, when applied in composites, have better mechanical and dielectric properties for many structural and multifunctional applications, including advanced aerospace applications and energy storage devices. For these applications, most fiber alignment electrospinning research has focused on either mechanical property improvement or dielectric property improvement alone, but not both simultaneously. Relative to many other nanofiber formation techniques, the electrospinning technique exhibits superior nanofiber formation when considering cost and manufacturing complexity for many situations. Even though the dielectric property of pure nanofiber mat may not be of general interest, the analysis of the combined effect of mechanical and dielectric properties is relevant to the present analysis of improved and aligned nanofibers. A plethora of nanofibers, in particular, polyacrylonitrile (PAN) electrospun nanofibers, are discussed for their mechanical and dielectric properties. In addition, other types of electrospun nanofibers are explored for their mechanical and dielectric properties. An exploratory study by the author demonstrates the relationship between mechanical and dielectric properties for specimens obtained from a rotating mandrel horizontal setup.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Radiative Grain Alignment in Protoplanetary Disks: Implications for Polarimetric Observations

We apply the theory of radiative torque (RAT) alignment for studying protoplanetary disks around a T-Tauri star and perform 3D radiative transfer calculations to provide the expected maps of polarized radiation to be compared with observations, such as with ALMA. We revisit the issue of grain alignment for large grains expected in the protoplanetary disks and find that mm-sized grains at the midplane do not align with the magnetic field since the Larmor precession timescale for such large grains becomes longer than the gaseous damping timescale. Hence, for these grains the RAT theory predicts that the alignment axis is determined by the grain precession with respect to the radiative flux. As a result, we expect that the polarization will be in the azimuthal direction for a face-on disk. It is also shown that if dust grains have superparamagnetic inclusions, magnetic field alignment is possible for (sub-)micron grains at the surface layer of disks, and this can be tested by mid-infrared polarimetric observations.

79 ASTRONOMY AND ASTROPHYSICS↗

High Precision Track-Based Alignment of the Tracking Detector of the g-2 Experiment

In order for the analysis of data from the tracking detector to reduce the systematic uncertainty on the a_μ measurement and improve the sensitivity to a muon electric dipole moment, the internal position of the tracking modules must be known to a high level of precision. Track-based alignment was implemented with data from Run 1 using the Millepede II framework. An overview of the alignment methods, as well as the verification of alignment with simulation, will be given. A significant improvement in the mean p-value distribution and the fraction of reconstructed tracks after the alignment was achieved. A comparison of the accuracy in the determination of the beam's spatial distribution as a function of time will be presented before and after the alignment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multidimensional alignment apparatus for hard x-ray focusing with two multilayer laue lenses

A multidimensional alignment apparatus is provided for multidimensional aligning of two linear multilayer Laue lenses (MLLs) for two-dimensional hard X-ray focusing. The multidimensional alignment apparatus precisely aligns and ensures stability of two linear MLLs performing hard x-ray focusing. The multidimensional alignment apparatus includes a base, a lower stages group controlling a first upstream MLL, an upper stages group positioned over the lower stages group controlling a second downstream MLL and an upper stage support attached to the base. The lower stages group provides five degrees of freedom precision positioning adjustment for the first upstream MLL. The second downstream MLL is mounted on the upper stages group with three degrees of freedom adjustment capability.

Shu, Deming↗