Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “2D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Chemistry in confined space through the eyes of surface science—2D porous materials

There are a rapidly growing number of studies showing exciting new opportunities in the way confinement effects on surfaces affect the properties of materials and their chemistry. These effects have been observed recently under two-dimensional (2D) van der Waals materials such as a graphene and boron nitride and for the case of supported 2D-porous oxides, including silicates, aluminosilicates and zeolite nanosheets. This review summarizes the current state of the art in this area of research and how confinement effects in 2D systems relate to those found in 3D porous and layered materials. The focus of this review is put in 2D-materials with inherent porosity, such as 2D-porous oxides. An outlook is also given for the future of this exciting emerging area.

36 MATERIALS SCIENCE↗

An outlook into the flat land of 2D materials beyond graphene: synthesis, properties and device applications

Abstract The field of two-dimensional (2D) and layered materials continues to excite many researchers around the world who are eager to advance and innovate viable routes for large scale synthesis, doping and integration of monolayers and the development of unique characterization approaches for studying and harnessing exotic properties that will enable novel device applications. There has been a large interest in 2D materials beyond graphene, with particular emphasis on monoelemental materials (phosphorene, silicene, tellurene, etc. ), 2D compounds (MXenes, oxides, nitrides, carbides and chalcogenides), their alloys and layered van der Waals heterostructures. This is not only indicated by the significant increase in the number of peer reviewed publications each year in this area of research, but also by the surging number of conference sessions focusing on 2D materials beyond graphene. This Perspective article highlights some of the recent advances in the field from a diverse international community of theoretical and experimental researchers who participated in the symposium ‘Beyond Graphene 2D Materials—Synthesis, Properties and Device Applications’ at the Materials Research Society (MRS) Fall 2019 meeting.

McCreary, Amber (ORCID:0000000299885800)↗

Discovery of a Novel Linear-in-k Spin Splitting for Holes in the 2D GaAs/AlAs System

The spin-orbit interaction generally leads to spin splitting (SS) of electron and hole energy states in solids, a splitting that is characterized by a scaling with the wave vector k. Whereas for 3D bulk zinc blende solids the electron (heavy-hole) SS exhibits a cubic (linear) scaling with k, in 2D quantum wells, the electron (heavy-hole) SS is currently believed to have a mostly linear (cubic) scaling. Such expectations are based on using a small 3D envelope function basis set to describe 2D physics. By treating instead the 2D system explicitly as a system in its own right, we discover a large linear scaling of hole states in 2D. This scaling emerges from coupling of hole bands that would be unsuspected by the standard model that judges coupling by energy proximity. This discovery of a linear Dresselhaus k scaling for holes in 2D implies a different understanding of hole physics in low dimensions.

36 MATERIALS SCIENCE↗

Self-Consistent Interpretation of the 2D Structure of the Liquid Au[subscript 82]Si[subscript 18] Surface: Bending Rigidity and the Debye-Waller Effect

The structural and mechanical properties of 2D crystalline surface phases that form at the surface of liquid eutectic Au{sub 82}Si{sub 18} are studied using synchrotron x-ray scattering over a large temperature range. In the vicinity of the eutectic temperature the surface consists of a 2D atomic bilayer crystalline phase that transforms into a 2D monolayer crystalline phase during heating. The latter phase eventually melts into a liquidlike surface on further heating. We demonstrate that the short wavelength capillary wave fluctuations are suppressed due to the bending rigidity of 2D crystalline phases. The corresponding reduction in the Debye-Waller factor allows for measured reflectivity to be explained in terms of an electron density profile that is consistent with the 2D surface crystals.

43 PARTICLE ACCELERATORS↗

A real-time dynamic-MLC control algorithm for delivering IMRT to targets undergoing 2D rigid motion in the beam's eye view

An MLC control algorithm for delivering intensity modulated radiation therapy (IMRT) to targets that are undergoing two-dimensional (2D) rigid motion in the beam's eye view (BEV) is presented. The goal of this method is to deliver 3D-derived fluence maps over a moving patient anatomy. Target motion measured prior to delivery is first used to design a set of planned dynamic-MLC (DMLC) sliding-window leaf trajectories. During actual delivery, the algorithm relies on real-time feedback to compensate for target motion that does not agree with the motion measured during planning. The methodology is based on an existing one-dimensional (1D) algorithm that uses on-the-fly intensity calculations to appropriately adjust the DMLC leaf trajectories in real-time during exposure delivery [McMahon et al., Med. Phys. 34, 3211-3223 (2007)]. To extend the 1D algorithm's application to 2D target motion, a real-time leaf-pair shifting mechanism has been developed. Target motion that is orthogonal to leaf travel is tracked by appropriately shifting the positions of all MLC leaves. The performance of the tracking algorithm was tested for a single beam of a fractionated IMRT treatment, using a clinically derived intensity profile and a 2D target trajectory based on measured patient data. Comparisons were made between 2D tracking, 1D tracking, and no tracking. The impact of the tracking lag time and the frequency of real-time imaging were investigated. A study of the dependence of the algorithm's performance on the level of agreement between the motion measured during planning and delivery was also included. Results demonstrated that tracking both components of the 2D motion (i.e., parallel and orthogonal to leaf travel) results in delivered fluence profiles that are superior to those that track the component of motion that is parallel to leaf travel alone. Tracking lag time effects may lead to relatively large intensity delivery errors compared to the other sources of error investigated. However, the algorithm presented is robust in the sense that it does not rely on a high level of agreement between the target motion measured during treatment planning and delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction of DVH parameter changes due to setup errors for breast cancer treatment based on 2D portal dosimetry

Electronic portal imaging devices (EPIDs) are increasingly used for portal dosimetry applications. In our department, EPIDs are clinically used for two-dimensional (2D) transit dosimetry. Predicted and measured portal dose images are compared to detect dose delivery errors caused for instance by setup errors or organ motion. The aim of this work is to develop a model to predict dose-volume histogram (DVH) changes due to setup errors during breast cancer treatment using 2D transit dosimetry. First, correlations between DVH parameter changes and 2D gamma parameters are investigated for different simulated setup errors, which are described by a binomial logistic regression model. The model calculates the probability that a DVH parameter changes more than a specific tolerance level and uses several gamma evaluation parameters for the planning target volume (PTV) projection in the EPID plane as input. Second, the predictive model is applied to clinically measured portal images. Predicted DVH parameter changes are compared to calculated DVH parameter changes using the measured setup error resulting from a dosimetric registration procedure. Statistical accuracy is investigated by using receiver operating characteristic (ROC) curves and values for the area under the curve (AUC), sensitivity, specificity, positive and negative predictive values. Changes in the mean PTV dose larger than 5%, and changes in V{sub 90} and V{sub 95} larger than 10% are accurately predicted based on a set of 2D gamma parameters. Most pronounced changes in the three DVH parameters are found for setup errors in the lateral-medial direction. AUC, sensitivity, specificity, and negative predictive values were between 85% and 100% while the positive predictive values were lower but still higher than 54%. Clinical predictive value is decreased due to the occurrence of patient rotations or breast deformations during treatment, but the overall reliability of the predictive model remains high. Based on our predictive model, 2D transit dosimetry measurements can now directly be translated in clinically more relevant DVH parameter changes for the PTV during conventional breast treatment. In this way, the possibility to design decision protocols based on extracted DVH changes is created instead of undertaking elaborate actions such as repeated treatment planning or 3D dose reconstruction for a large group of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-639: A Study On the Response of 2D Array Detector for VMAT Delivery for a Period of Two Years

Purpose: To evaluate the 2D array for radiation response for a period of 2 years. Methods: 45 VMAT plans already treated and quality assured before 2 years, 1.5 years and 1 year were selected for the study. Quality assurances of the plans were done using 2D array combined with Octavius phantom. Verification plans were recalculated without changing any parameters in Eclipse 10.0 TPS using the AAA algorithm. Response of 2D array to the plans treated before 2 years, 1.5 years and 1 year where evaluated. The results were analyzed using the Gamma analysis method with the standard gamma passing criteria of 3mm distance to agreement (DTA) and 3% dose difference (DD). Results: All the plans evaluated passed the gamma analysis with a percentage greater than 95, except for three cases. Higher gamma passing criteria where observed for all the analyzed plans, when analysis done before 2 years, 1.5 years and 1 year. The standard deviation of ± 1.38, ± 1.40,± 0.97 where observed between the plans when verification plans did before 2 years, 1.5 years and 1 year respectively. Same set of plans shows a standard deviation of ± 0.70, ± 1.36, and ± 1.18, when analysis done recently. A significance difference in response of the array when analysis done recently for the verification plans treated and quality assured before 2 years.This indicates a slightly reduced response of 2D array towards radiation response as the array gets older. Conclusion: It is found that 2D array shows a reduced response against radiation detection over a period of years. An onsite calibration of the instrument is recommended before the measurements. A dose correction factor can be applied if necessary to the results if the radiation response and efficiency of the array is very poor.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-CAMPUS-T-05: Preliminary Results On a 2D Dosimetry System Based On the Optically Stimulated Luminescence of Al2O3

Purpose: To develop a precise 2D dose mapping technique based on the optically stimulated luminescence (OSL) from Al{sub 2}O{sub 3} films for medical applications. Methods: A 2D laser scanning reader was developed using fast F{sup +}-center (lifetime of <7 ns) and slow F-center (lifetime of 35 ms) OSL emission from newly developed Al{sub 2}O{sub 3} films (Landauer Inc.). An algorithm was developed to correct images for both material and system properties. Since greater contribution of the F??-center emission in the recorded signal increases the readout efficiency and robustness of image corrections, Al{sub 2}O{sub 3}:C,Mg film samples are being investigated in addition to Al{sub 2}O{sub 3}:C samples. Preliminary investigations include exposure of the films to a 6 MV photon beam at 10 cm depth in solid water phantom with an SSD of 100 cm, using a 10 cm × 10 cm flat field or a 4 cm × 4 cm field with a 60° wedge filter. Kodak EDR2 radiographic film and EBT2 Gafchromic film were also exposed for comparison. Results: The results indicate that the algorithm is able to correct images and calculate 2D dose. For the wedge field irradiation, the calculated dose at the center of the field was 0.9 Gy for Al{sub 2}O{sub 3}:C and 0.87 Gy for Al{sub 2}O{sub 3}:C,Mg, whereas, the delivered dose was 0.95 Gy. A good qualitative agreement of the dose profiles was obtained between the OSL films and EDR2 and EBT2 films. Laboratory tests using a beta source suggest that a large dynamic range (10{sup −2}−10{sup 2} Gy) can be achieved using this technique. Conclusion: A 2D dosimetry system and an in-house image correction algorithm were developed for 2D film dosimetry in medical applications. The system is in the preliminary stage of development, but the data demonstrates the feasibility of this approach. This work was supported by Landauer, Inc.

36 MATERIALS SCIENCE↗

WE-EF-210-06: Ultrasound 2D Strain Measurement of Radiation-Induced Toxicity: Phantom and Ex Vivo Experiments

Purpose: Radiation-induced fibrosis is a common long-term complication affecting many patients following cancer radiotherapy. Standard clinical assessment of subcutaneous fibrosis is subjective and often limited to visual inspection and palpation. Ultrasound strain imaging describes the compressibility (elasticity) of biological tissues. This study’s purpose is to develop a quantitative ultrasound strain imaging that can consistently and accurately characterize radiation-induce fibrosis. Methods: In this study, we propose a 2D strain imaging method based on deformable image registration. A combined affine and B-spline transformation model is used to calculate the displacement of tissue between pre-stress and post-stress B-mode image sequences. The 2D displacement is estimated through a hybrid image similarity measure metric, which is a combination of the normalized mutual information (NMI) and normalized sum-of-squared-differences (NSSD). And 2D strain is obtained from the gradient of the local displacement. We conducted phantom experiments under various compressions and compared the performance of our proposed method with the standard cross-correlation (CC)- based method using the signal-to-noise (SNR) and contrast-to-noise (CNS) ratios. In addition, we conducted ex-vivo beef muscle experiment to further validate the proposed method. Results: For phantom study, the SNR and CNS values of the proposed method were significantly higher than those calculated from the CC-based method under different strains. The SNR and CNR increased by a factor of 1.9 and 2.7 comparing to the CC-based method. For the ex-vivo experiment, the CC-based method failed to work due to large deformation (6.7%), while our proposed method could accurately detect the stiffness change. Conclusion: We have developed a 2D strain imaging technique based on the deformable image registration, validated its accuracy and feasibility with phantom and ex-vivo data. This 2D ultrasound strain imaging technology may be valuable as physicians try to eliminate radiation-induce fibrosis and improve the therapeutic ratio of cancer radiotherapy. This research is supported in part by DOD PCRP Award W81XWH-13-1-0269, and National Cancer Institute (NCI) Grant CA114313.

60 APPLIED LIFE SCIENCES↗

Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner

Purpose: Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and detector during the scan would result in unacceptable loss of primary radiation. However, in the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis, the tube and detector rotate around a common axis, thereby maintaining a fixed tube-detector alignment. This C-arm geometry raises the possibility of using a 2D (cellular) focused antiscatter grid. The purpose of this study is to assess change in image quality when using an antiscatter grid in the DBT portion of a DMT scan under conditions of fixed radiation dose. Methods: Two 2D focused prototype grids with 80 cm focal length were tested, one stack-laminated from copper (Cu) and one cast from a tungsten-polymer (W-poly). They were reciprocated using a motion scheme designed to maximize transmission of primary x-ray photons. Grid-in and grid-out scatter-to-primary ratios (SPRs) were measured for rectangular blocks of material simulating 30%, 50%, and 70% glandular tissue compositions. For assessment of changes in image quality through the addition of a grid, the Computerized Imaging Reference Systems, Inc., phantom Model 011A containing a set of 1 cm thick blocks simulating a range of glandular/adipose ratios from 0/100 to 100/0 was used. To simulate 6.5 and 8.5 cm thick compressed breasts, 1 cm thick slices of PMMA were added to the Model 011A phantom. DBT images were obtained with and without the grid, with exposure parameters fixed for a given compressed thickness. Signal-difference-to-noise ratios (SDNRs), contrast, and voxel value-based attenuation coefficients (μ) were measured for all blocks from reconstructed phantom images. Results: For 4, 6, and 8 cm tissue-equivalent block phantom thicknesses, the inclusion of the W-poly grid reduced the SPR by factors of 5, 6, and 5.8, respectively. For the same thicknesses, the copper grid reduced the SPR by factors of 3.9, 4.5, and 4.9. For the 011A phantom, the W-poly grid raised the SDNR of the 70/30 block from 0.8, −0.32, and −0.72 to 0.9, 0.76, and 0.062 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. It raised the SDNR of the 100/0 block from 3.78, 1.95, and 1.0 to 3.79, 3.67, and 3.25 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. Inclusion of the W-poly grid improved the accuracy of image-based μ values for all block compositions. However, smearing of attenuation across slices due to limited angular sampling decreases the sensitivity of voxel values to changing composition compared to theoretical μ values. Conclusions: Under conditions of fixed radiation dose to the breast, use of a 2D focused grid increased contrast, SDNR, and accuracy of estimated attenuation for mass-simulating block compositions in all phantom thicknesses tested, with the degree of improvement depending upon material composition. A 2D antiscatter grid can be usefully incorporated in DBT systems that employ fully isocentric tube-detector rotation.

60 APPLIED LIFE SCIENCES↗

How does C-VIEW image quality compare with conventional 2D FFDM?

Purpose: The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered. The goal of this study was to compare the intrinsic image quality of synthesized 2D C-VIEW and 2D FFDM images in terms of resolution, contrast, and noise. Methods: Two phantoms were utilized in this study: the American College of Radiology mammography accreditation phantom (ACR phantom) and a novel 3D printed anthropomorphic breast phantom. Both phantoms were imaged using a Hologic Selenia Dimensions 3D system. Analysis of the ACR phantom includes both visual inspection and objective automated analysis using in-house software. Analysis of the 3D anthropomorphic phantom includes visual assessment of resolution and Fourier analysis of the noise. Results: Using ACR-defined scoring criteria for the ACR phantom, the FFDM images scored statistically higher than C-VIEW according to both the average observer and automated scores. In addition, between 50% and 70% of C-VIEW images failed to meet the nominal minimum ACR accreditation requirements—primarily due to fiber breaks. Software analysis demonstrated that C-VIEW provided enhanced visualization of medium and large microcalcification objects; however, the benefits diminished for smaller high contrast objects and all low contrast objects. Visual analysis of the anthropomorphic phantom showed a measureable loss of resolution in the C-VIEW image (11 lp/mm FFDM, 5 lp/mm C-VIEW) and loss in detection of small microcalcification objects. Spectral analysis of the anthropomorphic phantom showed higher total noise magnitude in the FFDM image compared with C-VIEW. Whereas the FFDM image contained approximately white noise texture, the C-VIEW image exhibited marked noise reduction at midfrequency and high frequency with far less noise suppression at low frequencies resulting in a mottled noise appearance. Conclusions: Their analysis demonstrates many instances where the C-VIEW image quality differs from FFDM. Compared to FFDM, C-VIEW offers a better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-VIEW images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging. Not explicitly explored in this study is how the combination of DBT + C-VIEW performs relative to DBT + FFDM or FFDM alone.

60 APPLIED LIFE SCIENCES↗

Amorphous 2D Materials – A Novel Platform for Remote Epitaxy and Nanopatterned Epitaxy of III-V Semiconductors with Low Decomposition Temperatures

III-V semiconductor materials such as indium phosphide (InP) offer outstanding photonic properties that outperforms silicon, but the cost of these wafers is extremely expensive. Although reusing original wafers can effectively minimize the cost, current techniques for wafer recycling of these substrates add significant costs in fabrication, nullifying the cost savings by reusing the wafers. Besides, unlike other III-V materials such as gallium arsenide (GaAs), commonly used epitaxial lift-off method for wafer recycling is not well studied for materials like InP due to lack of lattice-matched sacrificial layers, which makes reusing these wafers more difficult. Remote epitaxy and nanopatterned epitaxy are newly discovered methods that enable single-crystal growth of III-V semiconductor thin films and easy exfoliation of these grown films, thus promising for a new cost-effective pathway of reusing wafers. However, previous methods of transferring two-dimensional (2D) materials, which use polymethyl methacrylate (PMMA) or metal stressor layers to transfer 2D materials grown on foreign substrates like copper (Cu) or silicon carbide (SiC), introduce defects and damages on the 2D layer and/or substrates during the transfer process. Remote epitaxial and nanopatterned epitaxial films grown on the damaged 2D layer/substrate suffer from lower crystal quality and imperfect exfoliation, which undermines wafer reusability and device performance. Here we report the MBE growth of amorphous boron nitride (a-BN) on InP wafers at low temperature that enabled improved quality of remote epitaxial and nanopatterned epitaxial films and their perfect exfoliation. We show fully covered a-BN on InP substrates despite their low decomposition temperatures. The surface of a-BN coated InP substrate remains smooth with a RMS roughness of around 3&Acirc;. We also demonstrate 100% coverage of single-crystal InP thin films grown on a-BN, with the film's quality significantly improved compared to the case of transferred 2D materials. In addition, the growth and exfoliation were successfully repeated multiple times, proving the feasibility for InP wafer recycling. Through this low temperature MBE growth approach with remote epitaxy and nanopatterned epitaxy, we successfully demonstrate large-scale flexible thin film exfoliation and recycling of InP substrates, which will lead to new opportunities in InP thin film-based photonics and novel heterostructures with significantly reduced cost.

Lu, Kuangye↗

Amorphous 2D Materials – A Novel Platform for Remote Epitaxy and Nanopatterned Epitaxy of III-V Semiconductors with Low Decomposition Temperatures

III-V semiconductor materials such as indium phosphide (InP) offer outstanding photonic properties that outperforms silicon, but the cost of these wafers is extremely expensive. Although reusing original wafers can effectively minimize the cost, current techniques for wafer recycling of these substrates add significant costs in fabrication, nullifying the cost savings by reusing the wafers. Besides, unlike other III-V materials such as gallium arsenide (GaAs), commonly used epitaxial lift-off method for wafer recycling is not well studied for materials like InP due to lack of lattice-matched sacrificial layers, which makes reusing these wafers more difficult. Remote epitaxy and nanopatterned epitaxy are newly discovered methods that enable single-crystal growth of III-V semiconductor thin films and easy exfoliation of these grown films, thus promising for a new cost-effective pathway of reusing wafers. However, previous methods of transferring two-dimensional (2D) materials, which use polymethyl methacrylate (PMMA) or metal stressor layers to transfer 2D materials grown on foreign substrates like copper (Cu) or silicon carbide (SiC), introduce defects and damages on the 2D layer and/or substrates during the transfer process. Remote epitaxial and nanopatterned epitaxial films grown on the damaged 2D layer/substrate suffer from lower crystal quality and imperfect exfoliation, which undermines wafer reusability and device performance. Here we report the MBE growth of amorphous boron nitride (a-BN) on InP wafers at low temperature that enabled improved quality of remote epitaxial and nanopatterned epitaxial films and their perfect exfoliation. We show fully covered a-BN on InP substrates despite their low decomposition temperatures. The surface of a-BN coated InP substrate remains smooth with a RMS roughness of around 3Å. We also demonstrate 100% coverage of single-crystal InP thin films grown on a-BN, with the film's quality significantly improved compared to the case of transferred 2D materials. In addition, the growth and exfoliation were successfully repeated multiple times, proving the feasibility for InP wafer recycling. Through this low temperature MBE growth approach with remote epitaxy and nanopatterned epitaxy, we successfully demonstrate large-scale flexible thin film exfoliation and recycling of InP substrates, which will lead to new opportunities in InP thin film-based photonics and novel heterostructures with significantly reduced cost.

Lu, Kuangye↗

2D IR Microscopy—Technology for Visualizing Chemical Dynamics in Heterogeneous Environments (Final Technical Report)

The primary focus of this project was the design, prototype, and demonstration of a 2D IR microscope. The start date of this project was July 15, 2016 and the project end date was July 14, 2022. In the early years of this project our team designed, prototyped, and completely integrated a homebuilt microscope head with our high-repetition rate 2D IR spectrometer. Once in place our research team focused on characterizing the 2D IR microscope and using it to investigate model systems relevant to energy technologies. As part of this process, we identified two initial chemical systems to use to further develop 2D IR imaging modalities. The first chemical system developed was a room temperature ionic liquid (RTIL) electrolyte system and the second chemical system was a mixture of carbonates and salts developed as a battery electrolyte system. The completion of this project resulted in the full characterization of chemical dynamics in a bulk RTIL system and the demonstration of 2D IR imaging across the RTIL cast as a microdroplet in silicon oil. In addition, we explored the liquid structures and dynamics of organic carbonate mixtures from the vantage point of the vibrational probe, methyl thiocyanate. By the end of the project, we had moved toward in-depth studies of the organic carbonate mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2D Amorphous Carbon Dielectric Prepared from Solution Precursor for Nanoelectronics

The preparation of amorphous 2D nanodielectrics represents a major challenge due to the metastable nature of amorphous phases. We describe a scalable and solution-based strategy to prepare wafer-scale 2D amorphous carbon with thickness down to 1–2 atomic layers from coal-derived carbon quantum dots as precursors. The prepared atomically thin 2D amorphous carbon can be suspended over cavities as freestanding membranes with high modulus of 400±100 GPa and demonstrate robust dielectric properties with dielectric strength above 20 MV·cm-1 and leakage current density below 10-4 A·cm-2 through a scaled thickness of three-atomic layers. When implemented as ultrathin gate dielectrics in 2D transistors or ion-transport media in memristors, they enable exceptional device performance and spatiotemporal uniformity, resulting from their amorphous form, intrinsic ultrathinness, and 2D atomic structures.

Pham, Viet Hung↗

Solution-Based Synthesis of Ultrathin Quasi-2D Amorphous Carbon for Nanoelectronics

The synthesis of ultrathin 2D amorphous dielectric film represents a major challenge due to the metastable nature of amorphous phases. We describe a scalable and solution-based strategy to prepare wafer-scale 2D amorphous carbon with thickness down to 1–2 atomic layers from coal-derived carbon quantum dots as precursors. The prepared atomically thin 2D amorphous carbon can be suspended over cavities as freestanding membranes with high modulus of 400±100 GPa and demonstrate robust dielectric properties with dielectric strength above 20 MV·cm-1 and leakage current density below 10-4 A·cm-2 through a scaled thickness of three-atomic layers. When implemented as ultrathin gate dielectrics in 2D transistors or ion-transport media in memristors, they enable exceptional device performance and spatiotemporal uniformity, resulting from their amorphous form, intrinsic ultrathinness, and 2D atomic structures.

Pham, Viet Hung [NETL Site Support Contractor, Nat↗

Algorithm to extract direction in 2D discrete distributions and a continuous Frobenius norm

In this study, we present a novel algorithm for determining directionality in 2D distributions of discrete data. We compare a reference dataset with a known direction to a measured dataset with an unknown direction by the Frobenius norm of the difference (FND) to find the unknown direction. To generalize this concept, we develop a continuous Frobenius norm of the difference (CFND) as a continuous analog of the FND and derive its analytical expression. By relating fitted and normalized 2D Gaussian distributions, we show that the CFND approximates the FND, and we validate this relationship with computer simulations. We find that a first-order approximation of the CFND between two similar Gaussian distributions takes the form of an absolute sine function, offering a simple analytical form with potential for specialized applications in segmented inverse beta decay (IBD) neutrino detectors, astronomy, machine learning, and more. Although this method may easily extend to 3D scalar fields, our focus here is on 2D real-valued fields as it directly applies to directionality. Our methodology consists of modeling a 2D Gaussian distribution, binning the data into a histogram, and encoding it as a square matrix. Rotating this matrix around its geometric center and comparing it to a measured dataset using the FND gives us rotational data that we fit with an absolute sine function. The location of the minimum of this fit is the angle closest to the true angle of the direction in the measured dataset. We present the derivation and discuss initial applications of the CFND in our novel algorithm, demonstrating its success in approximating directionality in 2D distributions.

Data Analysis, Statistics and Probability (physics↗

The 2D Rydberg series in Al I

High quality ab initio electonic structure calculations were performed on the 2D Rydberg series in Al I. The configuration 3s3p2(2D) is shown to contribute substantially to the lowest four 2D Rydberg states. The same configuration also contributes substantially to a 2D state embedded in the ionization continuum. Computed oscillator strengths for the first six members of the 2D Rydberg transitions are given: these should be of substantially high accuracy than currently available values.

Taylor, Peter R.↗