Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “waveform analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Engineering studies related to the GEOS-C radar altimeter

Experiment requirements, technical characteristics, and GEOS-C radar altimeter related analyses are discussed along with results of a study on engineering test data requirements. Statistical analyses related to determination of wave height resolution achievable as a function of system characteristics and averaging period are described, in addition to a discussion on the desirability of using computer procedures to compensate for altitude tracker time-jitter. Data processing considerations for the GEOS-C system are examined. An extensive analysis of the spatial filter effect is given and results of a computation of geoidal power spectral density, based on Skylab altimeter data, is displayed and interpreted in terms of projected GEOS-C random errors. This information is then used in deriving minimum-mean-square filter procedures for both geoid undulation and slope data. The characteristics of mean received waveforms as a function of off-nadir angle are used to obtain tracker bias as a function of sea state and pointing angle. The angle estimation process proposed by the GEOS-C hardware contractor is also investigated from a standpoint of achievable angular resolution.

Miller, L. S.↗

Severe storm electricity

Severe storms and lightning were measured with a NASA U2 and ground based facilities, both fixed base and mobile. Aspects of this program are reported. The following results are presented: (1) ground truth measurements of lightning for comparison with those obtained by the U2. These measurements include flash type identification, electric field changes, optical waveforms, and ground strike location; (2) simultaneous extremely low frequency (ELF) waveforms for cloud to ground (CG) flashes; (3) the CG strike location system (LLP) using a combination of mobile laboratory and television video data are assessed; (4) continued development of analog-to-digital conversion techniques for processing lightning data from the U2, mobile laboratory, and NSSL sensors; (5) completion of an all azimuth TV system for CG ground truth; (6) a preliminary analysis of both IC and CG lightning in a mesocyclone; and (7) the finding of a bimodal peak in altitude lightning activity in some storms in the Great Plains and on the east coast. In the forms on the Great Plains, there was a distinct class of flash what forms the upper mode of the distribution. These flashes are smaller horizontal extent, but occur more frequently than flashes in the lower mode of the distribution.

Rust, W. D.↗

Analysis of nonlinear internal waves in the New York Bight

An analysis of the nonlinear-internal-wave evolution in the New York Bight was performed on the basis of current meter mooring data obtained in the New York Bight during the SAR Internal Wave Signature Experiment (SARSEX). The solitary wave theory was extended to include dissipation and shoaling effects, and a series of numerical experiments were performed by solving the wave evolution equation, with waveforms observed in the SARSEX area as initial conditions. The results of calculations demonstrate that the relative balance of dissipation and shoaling effects is crucial to the detailed evolution of internal wave packets. From an observed initial wave packet at the upstream mooring, the numerical evolution simulation agreed reasonably well with the measurements at the distant mooring for the leading two large solitons.

Liu, Antony K.↗

Micron-Sized Particles Detected in the Vicinity of Jupiter by the Voyager Plasma Wave Instruments

Wideband waveform data obtained by the plasma wave instruments onboard the Voyager 1 and 2 spacecraft have been used to study micron-sized dust particles in the vicinity of Jupiter. The technique used was developed during the flybys of Saturn, Uranus, and Neptune, and makes use of the fact that a particle striking the spacecraft at 10-20 km/s causes a voltage pulse in the plasma wave receiver. The waveform of the voltage pulse is much different than the waveform of plasma waves and provides a highly reliable method of detecting micron-sized dust particles. Although the dust impact rate observed in the vicinity of Jupiter is much lower than the rates at Saturn, Uranus, and Neptune, the particles are easily detectable. Approximately 1200 48-second frames of wideband waveform data were examined in the vicinity of Jupiter. Dust impact signatures were found in approximately 20% of these frames. The peak impact rates are about 1 impact per second, and the peak number densities are about 10(exp -5) m(exp -3). Most of the impacts occurred near the equatorial plane at radial distances less than about 35 R(sub j) from Jupiter. Analysis of the detection threshold indicates that the particles have masses greater than 10(exp -11) g, which corresponds to particles with diameters of a few micrometers or larger.

Tsintikidis, D.↗

Pulsed plasma thruster ignitor plug ignition characteristics

The operating characteristics of the semiconductor spark gap ignitor plug used to initiate the discharge in a pulsed plasma thruster are investigated. Current and voltage waveform measurements for the ignitor plug alone, and for the plug mounted in the thruster cathode indicate an average dynamic impedance of 0.2 ohms for a wide range of operating conditions, and a trigger circuit energy transfer efficiency to the plug on the order of 25%. Two modes of trigger ignition are found which are related to the rise time of the applied voltage pulse. Analysis of plasma characteristics reveals plug erosion to occur primarily in the semiconductor and anode regions, by mechanisms including plug metal embrittlement, plasma sputtering and vaporization caused by the discharge current pulse. Measurements also indicate a plume velocity on the order of 1580,000 cm/sec which increases with trigger circuit stored energy. The results establish levels of performance for future applications of semiconductor spark gap ignitor plugs in plasma devices.

Brady, M. E.↗

Analysis of electromagnetic fields on an F-106B aircraft during lightning strikes

Information on the exterior electromagnetic environment of an aircraft when it is struck by lightning has been obtained during thunderstorm penetrations with an F-106B aircraft. Electric and magnetic fields were observed, using mainly time-derivative type sensors, with bandwidths to 50 MHz. Lightning pulse lengths ranging from 25 ns to 7 microsec have been recorded. Sufficient high-frequency content was present to excite electromagnetic resonances of the aircraft, and peaks in the frequency spectra of the waveforms in the range 7 to 23 MHz are in agreement with the resonant frequencies determined in laboratory scale-model tests. Both positively and negatively charged strikes were experienced, and most of the data suggest low values of peak current.

Trost, T. F.↗

E and DE/DT waveshapes for narrow bipolar pulses in intracloud lightning

Wideband electric field and dE/dt waveforms were recorded and digitized at a 100 MS/s rate at KSC during the summer and fall of 1989. These waveforms were combined to produce composite electric fields with an effective bandwidth of 3 to 50 MHz. Bipolar electric field pulses are characterized in terms of their E and dE/dt waveshapes. Half width mean durations were found to be 1.83 and 3.64 microseconds for negative and positive bipolar pulses respectively. Twenty of thirty of these pulses were found to occur independently of any other lightning activity. Analysis of the frequency content of these pulses as a function of time shows that radiation at different frequencies peak at different times. In addition to the initial peak and subsequent overshoot in the composite E waveshape, secondary humps following the initial peak are characterized according to their time of occurrence within the pulse. THe 156 narrow negative bipolar pulses and 10 positive narrow bipolar pulses are analyzed. The dE/dt signatures range from impulsive variations lasting several microseconds both before and after the initial peak of the electric field pulse, to smoother variations closely associated with peak.

Medelius, Pedro J.↗

Micro-machined planar field asymmetric ion mobility spectrometer as a gas chromatographic detector

A planar high field asymmetric waveform ion mobility spectrometer (PFAIMS) with a micro-machined drift tube was characterized as a detector for capillary gas chromatography. The performance of the PFAIMS was compared directly to that of a flame ionization detector (FID) for the separation of a ketone mixture from butanone to decanone. Effluent from the column was continuously sampled by the detector and mobility scans could be obtained throughout the chromatographic analysis providing chemical inforrmation in mobility scans orthogonal to retention time. Limits of detection were approximately I ng for measurement of positive ions and were comparable or slightly better than those for the FID. Direct comparison of calibration curves for the FAIMS and the FID was possible over four orders of magnitude with a semi-log plot. The concentration dependence of the PFAIMS mobility scans showed the dependence between ion intensity and ion clustering, evident in other mobility spectrometers and atmospheric pressure ionization technologies. Ions were identified using mass spectrometry as the protonated monomer and the proton bound dimer of the ketones. Residence time for column effluent in the PFAIMS was calculated as approximately 1 ms and a 36% increase in extra-column broadening versus the FID occurred with the PFAIMS.

NASA Discipline Life Sciences Technologies↗

Nonlinear Dynamic Behavior of Impact Damage in a Composite Skin-Stiffener Structure

One of the key issues in composite structures for aircraft applications is the early identification of damage. Often, service induced damage does not involve visible plastic deformation, but internal matrix related damage, like delaminations. A wide range of technologies, comprising global vibration and local wave propagation methods can be employed for health monitoring purposes. Traditional low frequency modal analysis based methods are linear methods. The effectiveness of these methods is often limited since they rely on a stationary and linear approximation of the system. The nonlinear interaction between a low frequency wave field and a local impact induced skin-stiffener failure is experimentally demonstrated in this paper. The different mechanisms that are responsible for the nonlinearities (opening, closing and contact) of the distorted harmonic waveforms are separated with the help of phase portraits. A basic analytical model is employed to support the observations.

Ooijevaar, T. H.↗

AG Channel Measurement and Modeling Results for Over-Water and Hilly Terrain Conditions

This report describes work completed over the past year on our project, entitled "Unmanned Aircraft Systems (UAS) Research: The AG Channel, Robust Waveforms, and Aeronautical Network Simulations." This project is funded under the NASA project "Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS)." In this report we provide the following: an update on project progress; a description of the over-freshwater and hilly terrain initial results on path loss, delay spread, small-scale fading, and correlations; complete path loss models for the over-water AG channels; analysis for obtaining parameter statistics required for development of accurate wideband AG channel models; and analysis of an atypical AG channel in which the aircraft flies out of the ground site antenna main beam. We have modeled the small-scale fading of these channels with Ricean statistics, and have quantified the behavior of the Ricean K-factor. We also provide some results for correlations of signal components, both intra-band and inter-band. An updated literature review, and a summary that also describes future work, are also included.

Matolak, David W.↗

Gravitational Waves: Search Results, Data Analysis and Parameter Estimation. Amaldi 10 Parallel Session C2

The Amaldi 10 Parallel Session C2 on gravitational wave(GW) search results, data analysis and parameter estimation included three lively sessions of lectures by 13 presenters, and 34 posters. The talks and posters covered a huge range of material, including results and analysis techniques for ground-based GW detectors, targeting anticipated signals from different astrophysical sources: compact binary inspiral, merger and ringdown; GW bursts from intermediate mass binary black hole mergers, cosmic string cusps, core-collapse supernovae, and other unmodeled sources; continuous waves from spinning neutron stars; and a stochastic GW background. There was considerable emphasis on Bayesian techniques for estimating the parameters of coalescing compact binary systems from the gravitational waveforms extracted from the data from the advanced detector network. This included methods to distinguish deviations of the signals from what is expected in the context of General Relativity.

Tests of general relativity↗

A survey of the state-of-the-art and focused research in range systems, task 1

This final report presents the latest research activity in voice compression. We have designed a non-real time simulation system that is implemented around the IBM-PC where the IBM-PC is used as a speech work station for data acquisition and analysis of voice samples. A real-time implementation is also proposed. This real-time Voice Compression Board (VCB) is built around the Texas Instruments TMS-3220. The voice compression algorithm investigated here was described in an earlier report titled, Low Cost Voice Compression for Mobile Digital Radios, by the author. We will assume the reader is familiar with the voice compression algorithm discussed in this report. The VCB compresses speech waveforms at data rates ranging from 4.8 K bps to 16 K bps. This board interfaces to the IBM-PC 8-bit bus, and plugs into a single expansion slot on the mother board.

Omura, J. K.↗

Detection and characterization of fatigue cracks in thin metal plates by low frequency resonant model analysis

Low-frequency resonant model analysis, a technique for the detection and characterization of fatigue cracks in thin metal plates, which could be adapted to rapid scan or large area testing, is considered. Experimental data displaying a direct correlation between fatigue crack geometry and resonance frequency for the second vibrational plate mode are presented. FEM is used to calculate the mechanical behavior of the plates, and provides a comparison basis for the experimentally determined resonance frequency values. The waveform of the acoustic emission generated at the resonant frequency is examined; it provides the basis for a model of the interaction of fatigue crack faces during plate vibration.

Wincheski, B.↗

IMAGE EUV Observation of a Radially, Bifurcated Plasmapause: First Observations of a Possible Standing ULF Waveform in the Inner Magnetosphere

We present EUV observations of the plasmasphere-plasmapause from 19:38-22:11 UT on 28 June 2000 characterized by the presence of bifurcated radial enhancements of the He(+) plasma distribution in the nighside sector. These features remain stable throughout the period of observation and are found to co-rotate at 67% of the expected rate. Two-dimensional simulation of the plasmasphere assuming the presence of field lines resonances at L = 1.8 and 2.5 suggest that the organization of the outer plasmasphere and plasmapause is the result convective motion driven by a standing ULF-wave. Preliminary analysis of ground-based magnetometer data provided by the IMAGE magnetometer network during the period of EUV observation indicates the presence of a discrete spectrum of field line resonances extending down to 0.68-mHz.

Adrian, M. L.↗

A study of lightning in winter thunderstorms and the analysis of thunderstorm overflight data

Thunderstorms and the activities associated with them was the emphasis of this final report. The primary goal of the investigation of the dynamics, microphysics, and the electrical properties of tropical thunderstorms, was to understand the process or processes which initiate the precipitation in various convective clouds. A concept that the degree of atmospheric instability that determines the updraft velocity is different between those storms that generate electrical activity and those that do not. This is apparent in temperate latitudes, but in tropical regions, little knowledge of these interactions is available. Several ground monitoring stations have been set up and, along with a waveform recorder at one of the stations, the data collected from these stations will be analyzed in conjunction with other data collected from ship and airborne radars and airborne in situ measurements of electrical activity in coordination with the TOGA-COARE program.

Brook, Marx↗

Avalanche-diode oscillator circuit with tuning at multiple frequencies

Detailed theoretical analysis of three different modes or types of high efficiency oscillation in a PIN diode are presented. For the TRAPATT mode in a PIN diode, it is shown that a traveling avalanche zone is not necessary to generate a dense trapped plasma. An economical computer program for TRAPATT oscillations in a PIN diode is described. Typical results of diode power, dc-to-RF conversion efficiency, and required circuit impedances are presented for several different current waveforms. A semianalytical solution for a second type of high efficiency mode in a PIN diode is derived assuming a rectangular current waveform. A quasi-static approximation is employed to derive a semianalytical solution for the voltage across a PIN diode in a third mode, where avalanching occurs during a major portion of a half cycle. Calculations for this mode indicate that the power increases proportionally to the magnitude of the drive current with a small decrease in efficiency relative to the ordinary TRAPATT mode. An analytical solution is also given for a PIN diode, where it is assumed that the ionization coefficient is a step function. It is shown that the step-ionization approximation permits one to draw possible patterns of avalanche region in the depletion layer as a function of time. A rule governing admissible patterns is derived and an example solution given for one admissible pattern. Preliminary experimental results on the high-efficiency oscillations are presented and discussed. Two different experimental circuits, which used channel-dropping filters to provide independent harmonic tuning, are described. Simpler circuits used to produce high-efficiency oscillations are discussed. Results of experiments using inexpensive Fairchild FD300 diodes are given.

Parker, D.↗

Space Telecommunications Radio System (STRS) Application Repository Design and Analysis

The Space Telecommunications Radio System (STRS) Application Repository Design and Analysis document describes the STRS application repository for software-defined radio (SDR) applications intended to be compliant to the STRS Architecture Standard. The document provides information about the submission of artifacts to the STRS application repository, to provide information to the potential users of that information, and for the systems engineer to understand the requirements, concepts, and approach to the STRS application repository. The STRS application repository is intended to capture knowledge, documents, and other artifacts for each waveform application or other application outside of its project so that when the project ends, the knowledge is retained. The document describes the transmission of technology from mission to mission capturing lessons learned that are used for continuous improvement across projects and supporting NASA Procedural Requirements (NPRs) for performing software engineering projects and NASAs release process.

information retrieval↗

HERMeS Thruster Magnetic Field Topology Optimization Study: Performance, Stability, and Wear Results

NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. The TDU-1 thruster implements a magnetically shielded field topology and has demonstrated the elimination of the discharge channel erosion as a life limiting mechanism. Extensive wear testing the TDU Hall thrusters has identified the thruster front pole covers as the next life limiting component. This effort aims to explore and investigate alternate magnetic field topologies to assess whether reductions in the front pole cover erosion can be attained while still maintaining very low erosion rates on the discharge channel walls. Four candidate magnetic field topologies that reduce the effectiveness of the shielding along the discharge channel walls with the intent to also reduce the erosion rates along the front pole covers were designed. Three of the four candidate magnetic field topologies (B1, B2, and B4) have been manufactured and were subjected to an extensive test campaign that includes laser induced fluorescence (LIF), performance, stability, wear, plume, and thermal characterization. In Phase I, LIF measurements along the discharge chamber centerline found that upstream retraction of the thruster's peak magnetic field does result in an upstream shift of the acceleration zone but the magnitude of the shift does not correspond one-to-one to the shift in the location of the peak radial magnetic field magnitude. Phase II test segment results found at a normalized thruster magnetic field setting of 1, the thruster performance was very similar for all configurations. Discharge current waveforms ripple data indicated that configurations Bo, B1, and B2 has similar oscillatory profiles with the B2 configuration transitioning to higher oscillatory mode at 400V instead of the 450V observed for configurations B0 and B1. Configuration B4 ripple data indicates that the thruster was operating in a very oscillatory mode above 350V. Inner front pole cover erosion rates for configuration B1 were approximately 65% relative to B0 and the erosion rates for configuration B2 were 40% relative to B0. Analysis of the performance, stability, and wear test results of configurations B0, B1, B2, and B4 indicates that configuration B2 may present an alternative option for B0 because it mostly maintained the same performance and stability as configuration B0 but with 40% of the inner front pole cover erosion rate.

Kamhawi, Hani↗