Lab Homes

This dataset includes processed data from the Lab Homes (LH) Test Facility located on the PNNL campus in Richland, WA. This a set of 2 identical homes that allow for the side-by-side comparison/performance evaluation of different technologies under the same weather at any given time. The dataset spans December 6, 2021 to December 27, 2021 and represents a series of tests performed; calibration, set-point excitation, pre-heating, free-floating and warm up. The measurements correspond to whole building electrical power, HVAC energy use, water heating, appliances and lighting, as well as space temperatures, space humidity, window glass surface temperatures, through glass solar radiation, and meterological data from an onsite meteorological weather station. In addition to the measurements, a metadata .json file, a .ttl file to visualize the data as per BRICK schema, and a detailed .pdf description of the dataset are also provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular stage pressurized oxy-combustion (SPOC) power plant for biomass firing and coal-biomass co-firing. The SPOC process was modelled using Aspen Plus®, and largely based on a previous model designed by this group for SPOC coal firing. To enable comparison with current National Energy Technology Laboratory (NETL) Bio-Energy Carbon Capture and Storage (BECCS) studies, a 550 MWe SPOC power plant with a supercritical Rankine cycle (241 bar, 593°C, and 593°C), and 90% carbon capture was modeled, and hybrid poplar biomass was chosen. Two cases were evaluated, namely 100% biomass (carbon negative) and 25% biomass co-firing (carbon neutral), and the 100% Powder River Basin coal firing case was chosen for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water regeneration. Unique to the SPOC process, the boilers are arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the water leaving the bottom of the DCC is at a sufficiently high temperature that it can be used for boiler feed water heating, improving plant thermal efficiency. The SPOC efficiencies were above the BECCS cases with capture, and no efficiency penalty on the SPOC plant was observed with an increase of biomass in the mix mostly due to the higher oxygen content in biomass that resulted in lower oxygen requirement from the ASU, and the higher moisture in biomass that due to the key benefit of the SPOC process can be partially recovered as latent heat.

Magalhaes, Duarte↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands

The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.

Harber, H.↗

Hydrogeological Interpretation of Candidate Origin Sites for Martian Meteorite ALH84001

Barlow (this meeting) has identified two potential source craters for the martian meteorite ALH84001. The craters are at 11.7 deg S, 243.3 deg W (Mare Tyrrhenum site) and 14.0 deg S, 343.5 deg W (Sinus Sabaeus site). As noted by Barlow, both craters lie in the heavily cratered terrain (HCT) and are adjacent to fluvial valleys, Here I explore the fluvial history of these areas based upon the surrounding valley morphology. The most prominent valley network at the Sabaeus site is Evros Vallis. This wide, flat-floored valley is approximately 600 km long with an average width of 2.5 km and a depth of 220 m. The eroded volume of the entire Evros network is approximately 6 x 10(exp 11) cc. This is typical for networks located in the heavily cratered terrain (e.g. Warrego and Parana Valles). Evros is also an isolated valley system. No similar networks are found in the surrounding terrain. Thus it is unlikely that Evros formed as a result of widespread rainfall. A localized water source, such as discharge of a hydrothermal system or localized melting of snowfall, seems more consistent Previous modeling has demonstrated that only hydrothermal systems associated with high permeability subsurfaces can discharge sufficient water to form a valley network. The bulk of the discharge from such systems is consequently low temperature, slightly heated water Precipitation of calcium carbonate by low temperature fluids is consistent with most interpretations of the geochemistry of ALH84001. Available imagery at the Tyrrhenum site is of lesser quality. While eroded units of the HCT are nearby, there are no comparable well developed valley networks at this site. Erosion is instead manifested predominantly as gullies on slopes. This style of erosion suggests that water was not present at this site for the length of time as at the more integrated Sabaeus site. The superposition of fluidized ejecta blankets suggests however that ground water or ground ice was still present at this locality fairly recently, if the chosen crater is indeed correct.

Gulick, Virginia C.↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region (CRADA Final Report)

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

15 GEOTHERMAL ENERGY↗

SAM™ (System Advisor Model™) [SWR-16-02, SWR-10-13]

See the SAM™ website to build a desktop version of the National Laboratory of the Rockies' (NLR's) System Advisor Model™ (SAM). https://sam.nlr.gov/ The System Advisor Model™ (SAM™) is a free techno-economic software model that facilitates decision-making for people in the renewable energy industry: -Project managers and engineers -Policy analysts -Technology developers -Researchers SAM can model many types of renewable energy systems: -Photovoltaic systems, from small residential rooftop to large utility-scale systems -Battery storage with Lithium ion, lead acid, or flow batteries for front-of-meter or behind-the-meter applications -Concentrating Solar Power systems for electric power generation, including parabolic trough, power tower, and linear Fresnel -Industrial process heat from parabolic trough and linear Fresnel systems -Wind power, from individual turbines to large wind farms -Marine energy wave and tidal systems -Solar water heating -Fuel cells -Geothermal power generation -Biomass combustion for power generation -High concentration photovoltaic systems SAM's financial models are for the following types of projects: -Residential and commercial projects where the renewable energy system is on the customer side of the electric utility meter (behind the meter), and power from the system is used to reduce the customer's electricity bill. -Power purchase agreement (PPA) projects where the system is connected to the grid at an interconnection point, and the project earns revenue through power sales. The project may be owned and operated by a single owner or by a partnership involving a flip or leaseback arrangement. -Third party ownership where the system is installed on the customer's (host) property and owned by a separate entity (developer), and the host is compensated for power generated by the system through either a PPA or lease agreement. For a more detailed description of SAM, see Blair et al. (2018), System Advisor Model (SAM) General Description (Version 2017.9.5), NREL/TP-6A20-70414. https://www.nrel.gov/docs/fy18osti/70414.pdf

Ryberg, David↗

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗

Diffusion freezeout in gas-loaded heat pipes.

Experimental diffusion freezeout rates in a gas loaded heat pipe are presented and compared with predictions of an analysis and computer program published earlier. The experimental approach was to pivot a heat pipe on knife edges and use an analytical mass balance to measure the rate of mass migration within the pipe. Diffusion freezeout rates in a water heat pipe were measured as a function of the condenser sink temperature and the condenser-to-sink thermal conductance. Measured rates varied between 19 and 270 mg/hr and yielded 64 to 99 percent agreement with predicted values. These results indicated that the analysis and computer program for predicting the behavior of gas loaded heat pipes are useful tools for designing such systems.

Marcus, B. D.↗

Solar hot water system installed at Day's Inn Motel, Dallas, Texas (Valley View)

The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.

Source record↗

Combined photovoltaic and thermal-storage module

Module uses phase change heat absorbing wax to reduce peak temperatures, increasing electrical efficiency. Wax makes module more cost effective than conventional thermomodules by also storing thermal energy for air and water heating.

Stultz, J. W.↗

Implementing supercritical water oxidation technology in a lunar base environmental control/life support system

A supercritical water oxidation system (SCWOS) offers several advantages for a lunar base environmental control/life support system (ECLSS) compared to an ECLSS based on Space Station technology. In supercritically heated water (630 K, 250 atm) organic materials mix freely with oxygen and undergo complete combustion. Inorganic salts lose solubility and precipitate out. Implementation of SCWOS can make an ECLSS more efficient and reliable by elimination of several subsystems and by reduction in potential losses of life support consumables. More complete closure of the total system reduces resupply requirements from the earth, a crucial cost item in maintaining a lunar base.

Meyer Sedej, M.↗

Solar hot water system installed at Days Inn Motel, Dallas, Texas (Forrest Lane)

The solar system was designed to provide 65 percent of the total Domestic Hot Water (DHW) demand. The liquid flat plate (water) collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank located in the mechanical room when the pump is not running. Heat is transferred from the storage tank to DHW tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and the heat exchanger enables solar heated water to help make DHW tank standby losses. All pumps are controlled by differential temperature.

Source record↗

Solution combustion synthesis of iron-based alumina nanocomposites for clean production of hydrogen from fossil fuels

Iron-based alumina nanocomposites are promising materials for microwave-assisted thermocatalytic dehydrogenation of fossil fuels, which has been proposed for the production of hydrogen with no CO2 emissions. Solution combustion synthesis (SCS) is an attractive technique for the fabrication of these materials because it has been used for synthesis of many nanoscale oxides. However, SCS can be carried out using different organic fuels and different heating equipment, and it is important to determine which fuel and heating mode generate materials with the best properties for dehydrogenation, such as maximized specific surface area. In the present work, the iron-based alumina nanocomposites were obtained by SCS using two different fuels (citric acid and glycine) and two different heating modes (a hotplate and a muffle furnace). The precursors/oxidizers were iron nitrate and aluminum nitrate. They were mixed with the fuel according to stoichiometry and dissolved in water. Heating the solution resulted in combustion synthesis. The products were characterized by X-ray diffraction analysis, Brunauer-Emmett-Teller surface area analysis, laser diffraction particle size analysis, scanning electron microscopy, and energy dispersive X-ray spectroscopy. The experiments have shown that the specific surface area of the iron-based alumina nanocomposites obtained by SCS can be dramatically increased by using citric acid instead of glycine, and additionally by using a muffle furnace instead of a hotplate.

Solution combustion synthesis, Nanoscale metal oxi↗