Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

How to Boost the Breast Tumor Bed? A Multidisciplinary Approach in Eight Steps

Purpose: To describe a new procedure for breast radiotherapy that will improve tumor bed localization and radiotherapy treatment using a multidisciplinary approach. Patients and Methods: This pilot study was conducted by departments of radiation oncology, surgery, and radiology. A new procedure has been implemented, summarized as eight steps: from pre-surgery contrast CT to surgery, tumor bed planning target volume (PTV) determination, and finally breast and tumor bed irradiation. Results: Twenty patients presenting with T1N0M0 tumors were enrolled in the study. All patients underwent lumpectomy with the placement of surgical clips in the tumor bed region. During surgery, 1 to 5 clips were placed in the lumpectomy cavity before the plastic procedure. All patients underwent pre- and postoperative CT scans in the treatment position. The two sets of images were registered with a match-point registration. All volumes were contoured and the results evaluated. The PTV included the clips region, the gross tumor volume, and the surgical scar, with an overall margin of 5-10 mm in all directions, corresponding to localization and setup uncertainties. For each patient the boost PTV was discussed and compared with our standard forward-planned PTV. Conclusions: We demonstrate the feasibility of a tumor bed localization and treatment procedure that seems adaptable to routine practice. Our study shows the advantages of a multidisciplinary approach for tumor bed localization and treatment. The use of more than 1 clip associated with pre- to postoperative CT image registration allows better definition of the PTV boost volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparison of segmented abdominopelvic fluid volumes with conventional CT signs of abdominal compartment syndrome in a trauma population

Purpose: To compare the utility of abdominopelvic fluid volume measurements with established computed tomography signs for refractory post-traumatic abdominal compartment syndrome. Methods: This retrospective observational cohort study included 64 consecutive adult trauma patients with preoperative CT and diagnosis of refractory abdominal compartment syndrome requiring decompressive laparotomy at a level I trauma referral center between 2004 and 2014. We hypothesized that abdominal fluid volume measurements would be more predictive of the need for early laparotomy than previously described conventional CT signs of refractory ACS. Abdominopelvic fluid volumes were determined quantitatively using semi-automated segmentation software. The following conventional imaging parameters were recorded: abdominal anteroposterior:transverse ratio (round belly sign); infrahepatic vena cava diameter; distal abdominal aortic diameter; largest single small bowel wall diameter; hydronephrosis, inguinal herniation; and mesenteric and body wall edema. For outcome analysis, patients were stratified into two groups: those who underwent early (< 24 h) and late (≥ 24 h) decompressive laparotomy following CT. Correlation analysis, comparison of means, and multivariate logistic regression were performed. Results: Abdominal fluid volumes (p = 0.001) and anteroposterior:transverse ratio (p = 0.009) were increased and inferior vena cava diameter (p = 0.009) was decreased in the early decompressive laparotomy group. Multivariate analysis including conventional CT variables, fluid volumes, and laboratory values revealed abdominal fluid volumes (p = 0.012; Δ in log odds of 1.002/mL) as the only independent predictor of early decompressive laparotomy. Conclusions: Segmented abdominopelvic free fluid volumes had greater predictive utility for decision to perform early decompressive laparotomy than previously described ACS-related CT signs in trauma patients who developed refractory abdominal compartment syndrome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multilevel Morphology of Complex Nanoporous Materials

This work exploits gas adsorption and small-angle X-ray scattering (SAXS) to determine the morphology of complex nanoporous materials. We resolve multiple classes of porosity including previously undetected large-scale texture that significantly compromises the canonical interpretation of gas adsorption. Specifically, a UVM-7 class mesoporous silica was synthesized that has morphological features on three length scales: macropores due to packing of 150 nm globules, 1.9 nm radius spherical mesopores inside the globules, and >7 nm pockets on and between the globules. The total and external surface areas, as well as the mesopore volume, were determined using gas adsorption (α s -plot) and SAXS. A new approach was applied to the SAXS data using multilevel fitting to determine the surface areas on multiple length scales. The SAXS analysis code is applicable to any two-phase system and is freely available to the public. The total surface area determined by SAXS was 12% greater than that obtained by gas adsorption. The macropore interfacial area, however, is only 30% of the external surface area determined by the α s -plot. The overestimation of the external surface area by the αs-plot method is attributed to capillary condensation in nanoscale surface irregularities. Here, the discrepancy is resolved assuming that the macropore–globule interfaces harbor fractally distributed nooks and crannies, which lead to gas adsorption at pressures above the mesopore filling pressure.

36 MATERIALS SCIENCE↗

Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: in vitro and in vivo studies

OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.

NASA Discipline Cardiopulmonary↗

In Situ Aerosol Detector

An affordable technology designed to facilitate extensive global atmospheric aerosol measurements has been developed. This lightweight instrument is compatible with newly developed platforms such as tethered balloons, blimps, kites, and even disposable instruments such as dropsondes. This technology is based on detection of light scattered by aerosol particles where an optical layout is used to enhance the performance of the laboratory prototype instrument, which allows detection of smaller aerosol particles and improves the accuracy of aerosol particle size measurement. It has been determined that using focused illumination geometry without any apertures is advantageous over using the originally proposed collimated beam/slit geometry (that is supposed to produce uniform illumination over the beam cross-section). The illumination source is used more efficiently, which allows detection of smaller aerosol particles. Second, the obtained integral scattered light intensity measured for the particle can be corrected for the beam intensity profile inhomogeneity based on the measured beam intensity profile and measured particle location. The particle location (coordinates) in the illuminated sample volume is determined based on the information contained in the image frame. The procedure considerably improves the accuracy of determination of the aerosol particle size.

Vakhtin, Andrei↗

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using "Braslet-M" Occlusion Cuffs

BACKGROUND: The transition to microgravity eliminates the hydrostatic gradients in the vascular system. The resulting fluid redistribution commonly manifests as facial edema, engorgement of the external neck veins, nasal congestion, and headache. This experiment examined the responses to modified Valsalva and Mueller maneuvers as measured by cardiac and vascular ultrasound in a baseline microgravity steady state, and under the influence of thigh occlusion cuffs (Braslet cuffs). METHODS: Nine International Space Station crewmember subjects (Expeditions 16 - 20) were examined in 15 experiment sessions 101 46 days after launch (mean SD; 33 - 185). 27 cardiac and vascular parameters were obtained under three respiratory conditions (baseline, Valsalva, and Mueller) before and after tightening of the Braslet cuffs for a total of 162 data points per session. The quality of cardiac and vascular ultrasound examinations was assured through remote monitoring and guidance by Investigators from the NASA Telescience Center in Houston, TX, USA. RESULTS: Fourteen of the 81 measured conditions were significantly different with Braslet application and were apparently related to cardiac preload reduction or increase in the venous volume sequestered in the lower extremity. These changes represented 10 of the 27 parameters measured. In secondary analysis, 7 of the 27 parameters were found to respond differently to respiratory maneuvers depending on the presence or absence of thigh compression, with a total of 11 differences. CONCLUSIONS: Acute application of Braslet occlusion cuffs causes lower extremity fluid sequestration and exerts proportionate measurable effects on cardiac performance in microgravity. Ultrasound techniques measuring the hemodynamic effects of thigh cuffs in combination with respiratory maneuvers may serve as an effective tool in determining the volume status of a cardiac or hemodynamically compromised patient in microgravity.

Hamilton, D. R.↗

Viability of Small Dimension Crew Quarters for Surface Habitation

During early planning for the Artemis program’s sustained phase of lunar activity, NASA planners have been held to work towards a NASA reference lunar lander concept. With this activity taking place prior to the awarding of a lander contract, NASA planners cannot assume which of several potential landers will be available. This has limited habitation team engineers to a 12-metric ton mass limit for the reference concept of the lunar Surface Habitat. Consequently, minimal approaches have been applied to many habitat systems and it is important to determine acceptable volume for crew quarters. A number of both NASA and non-NASA surface habitat concepts have proposed relatively small crew quarters due to this constraint. Consequently, there is a need to collect objective test data to confirm or refute the validity of small crew quarters. NASA-STD-3001 is looked to for guidance in its many standards but offers little to no help. While prior versions called for private habitation, the current version – Revision B – calls for “individual privacy” to “accommodate social retreat.” Proposed Revision C modifications change the language slightly to “accommodate sleep and social retreat.” This is not enough guidance to determine the size of a crew quarters or even its capabilities. Unfortunately, only a small number of US spacecraft have included crew quarters, primarily the International Space Station and the Skylab Space Station. The space shuttle orbiter sometimes flew a set of private bunks that some might consider a crew quarters. All of these are dramatically smaller than US standards for minimum jail cells. The first opportunity for NASA to test a small crew quarters in a surface habitat application has been created through the Exploration Atmospheres test series, which is evaluating human performance under reduced cabin pressures. The test is converting the 20-Foot Vacuum Chamber at Johnson Space Center into a habitat, with the lower level outfitted as an EVA test area and the upper two levels for human habitation. The test will place eight people (six test subjects and two technicians) inside the chamber for eleven days. All eight will sleep in private quarters during the test. Volume limitations in the chamber forced extremely small crew quarters, measuring approximately 2 meters in length, 0.85 meters in height, and 0.9 meters in width. The test cabin pressure of 8.2 psi and elevated oxygen also introduces significant material limitations, limiting outfitting options. Nonetheless, the crew quarters design requirements were to accommodate visual separation, auditory separation, olfactory separation, tactile separation, air flow control, lighting control, single person personal computing, physical work surface access, sleep accommodations, non-sleep rest/relaxation, meditation, stretching, two-person meetings, snacking, changing clothes, viewing appearance, video communication, and audio communication. This paper will detail the acceptability of the crew quarters as measured in the October 2021 Exploration Atmosphere test. Based on this data, the viability of the type of crew quarters used in the 20 Foot Chamber will be assessed. Design recommendations for a 30-60-day Surface Habitat crew quarters will be provided, along with recommendations for future testing.

Crew Quarters↗

An Investigation Into Transecting Satellites in Future Space Traffic Management Scenarios

The number of satellites expected to populate the near-Earth space environment is set to dramatically increase in the coming decade as new large constellations are approved and deployed. Current strategies for placing new batches of these satellites on orbit often involve launching into an initial orbit, and then performing apogee raising maneuvers to reach a target altitude. Similarly, end-of-life planning for these constellation satellites can consist of de-orbit burns that lower perigee to permit disposal via re-entry. Both the raising and de-orbiting maneuvers can result in the individual satellites traveling in high-eccentricity orbits that have the potential to transect other spacecraft trajectories. While individual large constellations may be able to coexist in separate altitude and inclination bands, having thousands of satellites moving between these bands as new satellites are replaced and old ones are removed could pose additional collision risks. Similar concerns have been raised regarding the impact that large numbers of university-class CubeSats might have in terms of their overall collision risk, especially as these satellites typically do not have propulsion systems for active maneuvering. To assess the impact that transecting satellites might have to future space traffic management strategies, this study explored a variety of future realistic scenarios using a high-fidelity simulation tool. The model can simulate the orbit of tens of thousands of resident space objects (RSOs) simultaneously, to include active satellites, debris, rocket bodies, or even future hypothetical scenarios, using a realistic force model that incorporates non-spherical gravity, atmospheric drag, solar radiation pressure, and more. As the model is run forward in time, various statistics and meta-data are gathered on any predicted conjunction event, providing insight into the nature and frequency of potential collisions, e.g., what size are the two satellites, who operates the satellites, are they active or passive objects, etc. Additional customization is available in terms of how probability of collision is computed, and how the probability ellipsoids and screening volumes are determined. The simulation tool also allows for rule-based maneuvers for active satellites, e.g, given an advance conjunction “warning,” one or both of the satellites can maneuver to a safe distance. A wide range of maneuvers can be implemented using impulsive or low-thrust methods, and the latencies can also be varied, e.g., using maneuver lead times of 48 hours, 24 hours, or 12 hours. Validation of the simulation results is performed against current and historical datasets available, to include comparisons to prior conjunction data messages (CDMs), object properties (mass, volume, etc.), and two-line-element records from both public and internal sources. Using the simulation environment, an assessment on the general risks that transecting satellites might pose for hypothetical future space object environments will be presented. This will involve the simulation of approximately 50,000 new large constellation satellites, in addition to the existing catalog of approximately 20,000 known resident space objects (RSOs), over propagation periods of one month to one year. A description of the simulation methodologies, scenarios evaluated, and validation methods will also be presented, as well as a preliminary assessment of the effectiveness of several candidate maneuver strategies that have the potential to reduce collision risk between active satellites.

Brian Gunter↗

Comparison of cardiovascular function during the early hours of bed rest and space flight

This paper reviews the cardiovascular responses of six healthy male subjects to 6 hours in a 5 degrees head-down bed rest model of weightlessness, and compares these responses to those obtained when subjects were positioned in head-up tilts of 10 degrees, 20 degrees, and 42 degrees, simulating 1/6, 1/3, and 2/3 G, respectively. Thoracic fluid index, cardiac output, stroke volume, and peak flow were measured using impedance cardiography. Cardiac dimensions and volumes were determined from two-dimensional guided M-mode echocardiograms in the left lateral decubitus position at 0, 2, 4, and 6 hours. Cardiovascular response to a stand test were compared before and after bed rest. The impedance values were related to tilt angle for the first 2 hours of tilt; however, after 3 hours, at all four angles, values began to converge, indicating that cardiovascular homeostatic mechanisms seek a common adapted state, regardless of effective gravity level (tilt angle) up to 2/3 G. Echocardiography revealed that left ventricular end-diastolic and end-systolic volume, stroke volume, ejection fraction, heart rate, and cardiac output had returned to control values by hour 6 for all tilt angles. The lack of a significant immediate change in left ventricular end-diastolic volume, despite decrements in stroke volume (P < .05) and heart rate (not significant), indicates that multiple factors may play a role in the adaptation to simulated hypogravity. The echocardiography data indicated that no angle of tilt, whether head-down or head-up for 4 to 6 hours, mimicked exactly the changes in cardiovascular function recorded after 4 to 6 hours of space flight. Changes in left ventricular end-diastolic volume during space flight and tilt may be similar, but follow a different time course. Nevertheless, head-down tilt at 5 degrees for 6 hours mimics some (stroke volume, systolic and diastolic blood pressure, mean arterial blood pressure, and total resistance), but not all, of the changes occurring in an equivalent time of space flight. The magnitude of the change in the mean heart rate response to standing was greater after six hours of tilt at -5 degrees or 10 degrees. Thus, results from the stand test after 6 hours of bed rest at -5 degrees and 10 degrees, but not at 20 degrees or 42 degrees, are similar to those obtained after space flight.

Space Flight↗

Organ Deformation and Dose Coverage in Robotic Respiratory-Tracking Radiotherapy

Purpose: Respiratory motion presents a significant challenge in stereotactic body radiosurgery. Respiratory tracking that follows the translational movement of the internal fiducials minimizes the uncertainties in dose delivery. However, the effect of deformation, defined as any changes in the body and organs relative to the center of fiducials, remains unanswered. This study investigated this problem and a possible solution. Methods and Materials: Dose delivery using a robotic respiratory-tracking system was studied with clinical data. Each treatment plan was designed with the computed tomography scan in the end-expiration phase. The planned beams were applied to the computed tomography scan in end-inspiration following the shift of the fiducials. The dose coverage was compared with the initial plan, and the uncertainty due to the deformation was estimated. A necessary margin from the clinical target volume to the planning target volume was determined to account for this and other sources of uncertainty. Results: We studied 12 lung and 5 upper abdomen lesions. Our results demonstrated that for lung patients with properly implanted fiducials a 3-mm margin is required to compensate for the deformation and a 5-mm margin is required to compensate for all uncertainties. Our results for the upper abdomen tumors were still preliminary but indicated a similar result, although a larger margin might be required. Conclusion: The effect of body deformation was studied. We found that adequate dose coverage for lung tumors can be ensured with proper fiducial placement and a 5-mm planning target volume margin. This approach is more practical and effective than a recent proposal to combine four-dimensional planning with respiratory tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CDMS [100] and [111] Oriented Germanium Detectors

The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3-inch diameter x 1-inch thick target masses as particle detectors. The target is instrumented with both phonon and ionization sensors and comparison of energy in each channel provides event-by-event classification of electron and nuclear recoils. Fiducial volume is determined by the ability to obtain good phonon and ionization signal at a particular location. Due to electronic band structure in germanium, electron mass is described by an anisotropic tensor with heavy mass aligned along the symmetry axis defined by the [111] Miller index (L valley), resulting in large lateral component to the transport. The spatial distribution of electrons varies significantly for detectors which have their longitudinal axis orientations described by either the [100] or [111] Miller indices. Electric fields with large fringing component at high detector radius also affect the spatial distribution of electrons and holes. Both effects are studied in a 3 dimensional Monte Carlo and the impact on fiducial volume is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An electromagnetically navigated bronchoscopy system was constructed with accurate registration of an electromagnetic tracker and the CT volume on the basis of an improved marker-free registration approach that uses the bronchial centerlines and bronchoscope tip center information. The fiducial and target registration errors of our electromagnetic navigation system were about 6.6 and 4.5 mm in dynamic bronchial phantom validation.

60 APPLIED LIFE SCIENCES↗

Well-to-Wheels Greenhouse Gas Emission Analysis of High-Octane Fuels with Ethanol Blending: Phase II Analysis with Refinery Investment Options

Higher-octane gasoline can enable increases in an internal combustion engine’s energy efficiency and a vehicle’s fuel economy by allowing an increase in the engine compression ratio and/or by enabling downspeeding and downsizing. Producing high-octane fuel (HOF) with the current level of ethanol blending (E10) could increase the energy and greenhouse gas (GHG) emissions intensity of the fuel product from refinery operations. Alternatively, increasing the ethanol blending level in final gasoline products could be a promising solution to HOF production because of the high octane rating and potentially low blended Reid vapor pressure (RVP) of ethanol at 25% and higher of the ethanol blending level by volume. In our previous HOF well-to-wheels (WTW) report (the so-called phase I report of the HOF WTW analysis), we conducted WTW analysis of HOF with different ethanol blending levels (i.e., E10, E25, and E40) and a range of vehicle efficiency gains with detailed petroleum refinery linear programming (LP) modeling by Jacobs Consultancy and showed that the overall WTW GHG emission changes associated with HOFVs were dominated by the positive impact associated with vehicle efficiency gains and ethanol blending levels, while the refining operations to produce gasoline blendstock for oxygenate blending (BOB) for various HOF blend levels had a much smaller impact on WTW GHG emissions (Han et al. 2015). The scope of the previous phase I study, however, was limited to evaluating PADDs 2 and 3 operation changes with various HOF market share scenarios and ethanol blending levels. Also, the study used three typical configuration models of refineries (cracking, light coking, and heavy coking) in each PADD, which may not be representative of the aggregate response of all refineries in each PADD to various ethanol blending levels and HOF market scenarios. Lastly, the phase I study assumed no new refinery expansion in the existing refineries, which limited E10 HOF production to the volume achievable by the cracking refinery configuration. To be able to satisfy large market demands of E10 HOF, that study arbitrarily relaxed the RVP requirements by replacing reformulated gasoline (RFG) RVP requirement of 7 psi in summer with conventional gasoline (CG) RVP requirement of 9 psi in summer. To examine the response by all refineries in major refinery regions, this phase II of the HOF WTW analysis employed regionally aggregated refinery models for the following six regions: PADDs 1, 2, 3, 4, and 5 excluding California (CA) and CA separately. Using aggregate refinery models, this phase II study examined the impacts of ethanol blending and HOF market shares on the refinery operations in these six regions. Also, this study included refinery expansion to produce a pre-determined HOF volume with 10% ethanol blending. In particular, this study examined several refinery expansion options using refinery configuration models to investigate a practical refinery response to the increase in E10 HOF market demand.

54 ENVIRONMENTAL SCIENCES↗

Structure and Dynamics of Coronal Plasma

Brief summaries of the four published papers produced within the present performance period of NASA Grant NAGW-4081 are presented. The full text of the papers are appended to the report. The first paper titled "Coronal Structures Observed in X-rays and H-alpa Structures" was published in the Kofu Symposium proceedings. The study analyzes cool and hot behavior of two x-ray events, a small flare and a surge. It was found that a large H-alpha surge appears in x-rays as a very weak event, while a weak H-alpha feature corresponds to the brightest x-ray emission on the disk at the time of the observation. Calculations of the heating necessary to produce these signatures, and implications for the driving and heating mechanisms of flares vs. surges are presented. The second paper "Differential Magnetic Field Shear in an Active Region" has been published in The Astrophysical Journal. The study compared the three dimensional extrapolation of magnetic fields with the observed coronal structure in an active region. Based on the fit between observed coronal structure throughout the volume of the region and the calculated magnetic field configurations, the authors propose a differential magnetic field shear model for this active region. The decreasing field shear in the outer portions of the AR may indicate a continual relaxation of the magnetic field with time, corresponding to a net transport of helicity outward. The third paper "Difficulties in Observing Coronal Structure" has been published in the journal Solar Physics. This paper discusses the evidence that the temperature and density structure of the corona are far more complicated than had previously been thought. The discussion is based on five studies carried out by the group on coronal plasma properties, showing that any one x-ray instrument does see all of the plasma present in the corona, that hot and cool material may appear to be co-spatial at a given location in the corona, and that simple magnetic field extrapolations provide only a poor fit to the observed structure. The fourth paper "Analysis and Comparison of Loop Structures Imaged with NIXT and Yohkoh/SXT" has been published in Astronomy and Astrophysics. This paper analyzes and compares a variety of coronal loops, deriving loop pressure and emission measure from loop models. They are able to determine the volume filling factor in the corona, which is found to be in the range 0.001 to 0.01 for compact loops, and of order 1 for large structures. The small values suggest highly filamented structures, especially at lower temperatures.

Golub, Leon↗

An empirical study of the distribution of earthquakes with respect to rock type and depth

Whether fault slip occurs seismically or aseismically depends on the frictional properties of the fault, which might be expected to depend on rock type and depth, as well as other factors. To view the effect of rock type and depth on the distribution of earthquakes, we compare geologic models of the San Francisco Bay and the Southern California regions to the distribution of seismicity. We normalize the number of earthquakes within each rock type and depth interval by the corresponding volume to determine the earthquake density. Earthquake density is confirmed primarily by depth, while whether the rock is sedimentary or basement has only a secondary, depth-dependent effect on the earthquake density. At very shallow depths, there is no difference in earthquake density between sedimentary and basement rocks. The earthquake density of basement rocks increases with depth more rapidly than that of sedimentary rocks to a similar but shallower maximum.

3‐D geologic models↗

Effect of the hydration temperature on the pore structure of cement paste: Experimental investigation and micromechanical modelling

The hydration temperature has a considerable effect on the microstructure of cement paste. The microstructural changes with increasing curing temperature result in a significant decrease of cement mechanical properties. The present work aims at studying these phenomena via micromechanical modelling, based on an experimental characterization of cement microstructure. The pore structure of a class G oil-well cement paste (American Petroleum Institute classification) hydrated at different temperatures, between 7 °C and 90 °C is characterized. Then, the influence of the microstructure variations on the elastic properties of the hardened paste is explored through micromechanical modelling. A previous analysis of the microstructure enabled determining the volume fractions of different phases of a class G cement paste hydrated under different temperatures [1]. A multiscale self-consistent homogenization model is used based on these results to simulate the variations of the mechanical properties with hydration temperature. The results are compared with macro-scale elastic properties obtained from uniaxial compression tests. It is shown that the increasing capillary porosity with elevating hydration temperature, is not sufficient to fully explain this drop of elastic properties. The latter originates mainly from the decrease of the elastic properties of the foam composed of the porous C-S-H intermixed with capillary pores. The pore structure analysis coupled with the micromechanical modelling permitted a back-analysis of the intrinsic porosities of high density and low density C-S-H showing an almost constant LD intrinsic porosity and a significantly decreasing HD intrinsic porosity.

36 MATERIALS SCIENCE↗

Measurements of soot, OH, and PAH concentrations in turbulent ethylene/air jet flames

This paper presents results from an investigation of soot formation in turbulent, non-premixed, C{sub 2}H{sub 4}/air jet flames. Tests were conducted using a H{sub 2}-piloted burner with fuel issuing from a 2.18 mm i.d. tube into quiescent ambient air. A range of test conditions was studied using the initial jet velocity (16.2-94.1 m/s) as a parameter. Fuel-jet Reynolds numbers ranged from 4000 to 23,200. Planar laser-induced incandescence (LII) was employed to determine soot volume fractions, and laser-induced fluorescence (LIF) was used to measure relative hydroxyl radical (OH) concentrations and polycyclic aromatic hydrocarbons (PAHs) concentrations. Extensive information on the structure of the soot and OH fields was obtained from two-dimensional imaging experiments. Quantitative measurements were obtained by employing the LII and LIF techniques independently. Imaging results for soot, OH, and PAH show the existence of three soot formation/oxidation regions: a rapid soot growth region, in which OH and soot particles lie in distinctly different radial locations; a mixing-dominated region controlled by large-scale motion; and a soot-oxidation region in which the OH and soot fields overlap spatially, resulting in the rapid oxidation of soot particles. Detailed quantitative analyzes of soot volume fractions and OH and soot zone thicknesses were performed along with the temperature measurement using the N{sub 2}-CARS system. Measurements of OH and soot zone thicknesses show that the soot zone thickness increases linearly with axial distance in the soot formation region, whereas the OH zone thickness is nearly constant in this region. The OH zone thickness then rapidly increases with downstream distance and approximately doubles in the soot-oxidation region. Probability density functions also were obtained for soot volume fractions and OH concentrations. These probability density functions clearly define the spatial relationships among the OH, PAH concentrations, the soot formation, and oxidation processes. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗