A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Carbon Support Microstructure Impact on High Current Density Transport Resistances in PEMFC Cathode

Cell voltages at high current densities (HCD) of an operating proton-exchange membrane fuel cell (PEMFC) cathode suffer from losses due to the local-O 2 and bulk-H + transport resistances in the catalyst layer. Particularly, the microstructure of high surface area carbon (HSC) support upon which both the platinum catalyst and ionomer are dispersed play a pivotal role in controlling the reactant transport to the active site in the catalyst layer. In this study, we perform a systematic analysis of the underlying microstructure of platinum-cobalt catalyst dispersed on various HSC supports in terms of their surface area and pore-size distribution. The carbon microstructure was found to strongly influence the PtCo nanoparticle dispersion, catalyst layer ionomer distribution and transport losses governing the performance at HCD. Catalyst layer electrochemical diagnostics carried out to quantify local-O 2 transport resistance and bulk-H + transport resistance in the cathode were found to be directly correlated to the micropore (<2 nm) and macropore (>8 nm) surface areas of the carbon support, respectively. Finally, a 1D-performance model has been developed to assimilate our understanding of the catalyst layer microstructure and transport resistances at HCD.

25 ENERGY STORAGE↗

Underground coal operators install several new longwall mining systems

Several new names appear in the annual US Longwall Census, but the population remains the same: 52 although the number of longwall mines dropped from 40 to 47. CONSOL Energy remains the leader with 12 faces. Robert E. Murray owns 8 longwall mines followed by Arch Coal with 5 and Foundation Coal with 3. West Virginia has 13 longwalls followed by 9 in Pennsylvania, 7 in Utah and 6 in Alabama. The article describes CONSOL Energy's operations. A detailed table gives for each longwall installation, the ownership, seam height, cutting height, panel width and length, overburden, number of gate entries, depth of cut, model of equipment used (shearer, haulage system, roof support, face conveyor, stage loader, crusher, electrical controls and voltage to face). 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Residential Advanced Photovoltaic Inverter Pilot Study Results for Select Distribution Secondaries in Hawai'i

Penetration levels of residential rooftop solar photovoltaic (PV) generation on the Hawaiian island of O'ahu have increased significantly in recent years, with many circuits now at the limits of their PV hosting capacity. NREL and Hawaiian Electric have used this opportunity to deploy advanced inverters at new customer installations that would not otherwise have been approved, as a pilot study to gain first-hand operational field data and experience on the impact of inverter-based grid support functions. At each customer location, the deployed advanced inverters were remotely controlled and monitored. Additionally, customer AMI (smart meter) and secondary distribution transformer data was also available for the analysis. The analysis focused on quantifying the customer behind-the-meter voltage rise due to PV production, determining the customer voltage rise with advanced inverters in unity power factor as well as advanced grid support function modes, and estimating the curtailment when inverters have Volt-VAR and Volt-Watt enabled. The results show that: 1) Behind-the-meter voltage rise is often not negligible. 2) An inverter's operating point on a Volt-VAR/Volt-Watt curve depends strongly on the design of the secondary system on which it is installed. 3) The mitigation of voltage rise on the secondary system using Volt-VAR may not be effective if only a small proportion of inverters have grid support enabled, or if the reactance/resistance (X/R) ratio of the grid is low. 4) Volt-Watt curtailment can be estimated using co-located irradiance sensors but there may be opportunities to estimate it using inverter internal electrical measurements. 5) Estimated curtailment is very low for the locations analyzed to date.

14 SOLAR ENERGY↗

Unraveling membrane electrode assembly design for electrochemical conversion of carbon dioxide to formate/formic acid

This work presents a one-dimensional continuum modeling approach to investigate various cell architectures used for electrochemical conversion of CO 2 to formate/formic acid. Ion transport is simulated by a system of generalized modified Poisson–Nernst–Planck (GMPNP) equations that reflect the reactive transport phenomena including steric effects as the electrolyte solutions become concentrated. In the cathode catalyst layer, ionic current contributions from both the supporting electrolyte and solid-state ionomer are considered. Voltage and CO 2 utilization breakdowns are utilized to deconvolute the impacts of the cell architecture. The origins of (bi)carbonate formation in the cathode are explored, as the subsequent decrease in CO 2 availability is a key reason for low faradaic efficiencies to formate/formic acid. In addition, the role of a supporting electrolyte (KOH) is investigated to understand its tradeoffs: while the K + ions can improve both conductivity and electrochemically active surface area in the cathode, the presence of OH − ions raises the pH and leads to deleterious formation of (bi)carbonates. To this end, we also present parametric studies on the concentration and flow rate of supplied KOH to the cell, to establish a path towards eliminating the need for a supporting electrolyte.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of the polymorphs of VOPO 4 as multi-electron cathodes for rechargeable alkali-ion batteries

Multi-electron polyanion cathodes offer the potential for achieving both high voltage and high capacity in rechargeable alkali-ion batteries. Among the few materials known to exhibit multi-electron cycling, the polymorphs of VOPO 4 , which operate on the V 3+ –V 4+ –V 5+ redox couples, are particularly promising due to the high gravimetric capacities that have been achieved and the high voltage of the V 4+/5+ couple. In this work, we performed a systematic first principles investigation, supported by careful electrochemical characterization and published experimental data, of the relative thermodynamic stability, voltage, band gap, and diffusion kinetics for alkali intercalation into the β, ε and αI polymorphs of VOPO 4 . We find that all VOPO4 polymorphs remain reasonably stable with the insertion of one alkali ion per V, but are significantly destabilized with the insertion of two alkali ions per V. The voltages for Na insertion are ~0.33–0.69 V lower than those for Li insertion. We find that the αI polymorph is predicted to have higher Li + migration barriers and larger band gaps than the β and ε polymorphs, which account for the relatively worse electrochemical cycling performance observed. On the other hand, only the αI polymorph exhibits reasonably low barriers for Na + migration compared to the β and ε polymorphs, which are consistent with observed electrochemical performances reported thus far in the literature. We also show that differences in the voltage, kinetics and rate capability of these different polymorphs for Li and Na insertion can be traced back to their fundamentally different VO 6 /VO 5 -PO 4 frameworks.

Lin, Yuh-Chieh↗

Total number of longwall faces drops below 50

For the first time since Coal Age began its annual Longwall Census the number of faces has dropped below 50. A total of five mines operate two longwall faces. CONSOL Energy remains the leader with 12 faces. Arch Coal operates five longwall mines; Robert E. Murray owns five longwall mines. West Virginia has 13 longwalls, followed by Pennsylvania (8), Utah (6) and Alabama (6). A detailed table gives for each longwall installation, the ownership, seam height, cutting height, panel width and length, overburden, number of gate entries, depth of cut, model of equipment used (shearer, haulage system, roof support, face conveyor, stage loader, crusher, electrical controls and voltage to face). 2 tabs., 1 photo.

01 COAL, LIGNITE, AND PEAT↗

National Renewable Energy Laboratory (NREL) Topic 2 Final Report: End-to-End Communication and Control System to Support Clean Energy Technologies

This document is the final report of a two-year development, test, and demonstration project, 'Cohesive Application of Standards- Based Connected Devices to Enable Clean Energy Technologies.' The project was part of the National Renewable Energy Laboratory's (NREL's) Integrated Network Testbed for Energy Grid Research and Technology (INTEGRATE) initiative hosted at Energy Systems Integration Facility (ESIF). This project demonstrated techniques to control distribution grid events using the coordination of traditional distribution grid devices and high-penetration renewable resources and demand response. Using standard communication protocols and semantic standards, the project examined the use cases of high/low distribution voltage, requests for volt-ampere-reactive (VAR) power support, and transactive energy strategies using Volttron. Open source software, written by EPRI to control distributed energy resources (DER) and demand response (DR), was used by an advanced distribution management system (ADMS) to abstract the resources reporting to a collection of capabilities rather than needing to know specific resource types. This architecture allows for scaling both horizontally and vertically. Several new technologies were developed and tested. Messages from the ADMS based on the common information model (CIM) were developed to control the DER and DR management systems. The OpenADR standard was used to help manage grid events by turning loads off and on. Volttron technology was used to simulate a homeowner choosing the price at which to enter the demand response market. Finally, the ADMS used newly developed algorithms to coordinate these resources with a capacitor bank and voltage regulator to respond to grid events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ultra-broadband voltage-controlled oscillator linearization for frequency modulated continuous wave MMW imaging systems

Millimeter-wave (MMW) imaging systems require high resolution and spurious free dynamic range (SFDR) to produce images with low artifacts. In these systems, lateral resolution is determined by the center frequency and the ratio of the aperture size to the distance to the target. The downrange resolution is determined by the system bandwidth; for very fine downrange resolution of a target, or material layers/discontinuities, the bandwidth must be very broad. Additionally, the response over the bandwidth must be measured very rapidly to support high speed acquisition over large apertures. A voltage-controlled oscillator (VCO) is a standard means of generating the ultra-broadband frequency chirp. This paper investigates the use of a broadband VCO for use in MMW imaging systems, a linear-phase calibration technique, and digital-to-analog converter (DAC) parameter considerations for controlling the VCO.

FMCW, homodyne, VCO, DAC, difference frequency, SF↗

Distribution system versus bulk power system: identifying the source of electric service interruptions in the US

This study reports on the results from efforts by the Institute of Electric and Electronics Engineers (IEEE) Distribution Reliability Working Group (DRWG) and the U.S. Energy Information Administration (EIA) to improve the usefulness of reliability metrics by developing and then applying consistent, yet distinct measures of the continuity of supply based on the portion of the electric power system from which power interruptions originate: the lower voltage distribution system versus the high‐voltage bulk power system. The modified metrics better support reliability planning in the US because they separately measure the effectiveness of actions to improve reliability made by the two distinct groups of firms (and their regulators or oversight bodies) that are responsible for planning and operating each portion of the US electric power system. The authors then present for the first time quantitative information on the reliability of each portion of the US electric power system. When reliability is measured using the system average interruption duration index and the system average interruption frequency index, they find that the distribution system accounts for at least 94 and 92%, respectively, of all interruptions. They also find that these relationships have been stable over the recent past.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Theory and measurement of plasmonic terahertz detector response to large signals

Electron gas in the conduction channel of a Field Effect Transistor (FET) can support collective plasma oscillations tunable by the gate voltage. In the Dyakonov-Shur terahertz (THz) detector, nonlinearities in the plasma wave propagation in the gated channel of a FET lead to a constant source-to-drain voltage providing the detector output. We present the detector theory in the frame of the hydrodynamic model using the electron plasma Navier-Stokes and thermal transport equations, thus fully accounting for the hydrodynamic non-linearity, the viscosity, and pressure gradients in the detector response. Both resonant and broadband operations of the high electron mobility transistor (HEMT) based plasmonic detectors are described by this model. The relation between the electron channel density and gate voltage was modeled by the unified charge control model applicable both above and below the threshold voltage. The theoretical results are compared with the response measured in the short channel InGaAs HEMT and the analytical approximation. The THz source was operating at 1.63 THz, and the response was measured at varying signal intensities. The response of the detector operated in the open drain mode was measured above and below the threshold, and the theoretical and experimental results are shown to be in good agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carrier leakage into the continuum in diagonal GaAs/Al{sub 0.15}GaAs terahertz quantum cascade lasers

The maximum operating temperature reported so far for THz-QCLs is ∼200 K. With the well-known degradation mechanism of thermally activated LO-phonon scattering, one straightforward strategy to improve their temperature performances is the use of diagonal structures in which the upper-to-lower state scattering time is lengthened. However, the effectiveness of this method for achieving room temperature operation remains to be demonstrated. Here, we studied the temperature degradation of highly diagonal GaAs/Al{sub 0.15}GaAs THz-QCLs. By analyzing their output power dependence on temperature, we identified the physical mechanism that limits their performance to be thermally activated leakage into the continuum, as evidenced by the large activation energy of ∼80 meV extracted from the Arrhenius plot. This observation is further supported by a careful analysis of current-voltage characteristics, especially in regions of high biases. In order to significantly improve the temperature performances of diagonal THz-QCLs, this leakage should be eliminated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Growth and characterization of metamorphic InAs/GaSb tunnel heterojunction on GaAs by molecular beam epitaxy

The structural, morphological, optical, and electrical transport characteristics of a metamorphic, broken-gap InAs/GaSb p-i-n tunnel diode structure, grown by molecular beam epitaxy on GaAs, were demonstrated. Precise shutter sequences were implemented for the strain-balanced InAs/GaSb active layer growth on GaAs, as corroborated by high-resolution X-ray analysis. Cross-sectional transmission electron microscopy and detailed micrograph analysis demonstrated strain relaxation primarily via the formation of 90° Lomer misfit dislocations (MDs) exhibiting a 5.6 nm spacing and intermittent 60° MDs at the GaSb/GaAs heterointerface, which was further supported by a minimal lattice tilt of 180 arc sec observed during X-ray analysis. Selective area diffraction and Fast Fourier Transform patterns confirmed the full relaxation of the GaSb buffer layer and quasi-ideal, strain-balanced InAs/GaSb heteroepitaxy. Temperature-dependent photoluminescence measurements demonstrated the optical band gap of the GaSb layer. Strong optical signal at room temperature from this structure supports a high-quality material synthesis. Current–voltage characteristics of fabricated InAs/GaSb p-i-n tunnel diodes measured at 77 K and 290 K demonstrated two bias-dependent transport mechanisms. The Shockley–Read–Hall generation–recombination mechanism at low bias and band-to-band tunneling transport at high bias confirmed the p-i-n tunnel diode operation. This elucidated the importance of defect control in metamorphic InAs/GaSb tunnel diodes for the implementation of low-voltage and high-performance tunnel field effect transistor applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Multi-Metrics In Situ Aging Detector for SiC Power MOSFET Modules with Full Driver-Integration Capability

In this paper, the concept and prototype of an aging detector for silicon carbide (SiC) power metal oxide semiconductor field effect transistor (MOSFET) are proposed and described. It leverages the resonant peak values of gate-source voltage at different instants during the switching transients to decode the change of multiple aging indicators, such as the increases of on-state resistance and threshold voltage. Modeling-based analysis is conducted to support the idea. The detector can be fully integrated into gate drivers without any additional connection to the power stage and is functional during normal power stage operation. A prototype unit was built, and preliminary tests were conducted to validate the idea and the practicality of the detector.

aging↗

A Unified Wireless Charger, On-Board Charger, and Auxiliary Power Module for Electric Vehicle Charging Systems

This paper proposes a unified electric vehicle (EV) charging architecture that integrates wireless power transfer (WPT), an on-board charger (OBC), and an auxiliary power module (APM) within a single architecture. By sharing a multi-functional magnetic structure and active switch bridges, the proposed topology eliminates additional transformers and converter stages, reducing hardware complexity and improving power density. A multipurpose magnetic design achieves magnetic decoupling among the WPT, OBC, and APM functions while maintaining the required coupling for each mode. Through electrical reconfiguration, the WPT operates as an LCC-S converter, whereas the OBC and APM operate as dual-active-bridge (DAB) converters. The system supports multiple operating modes, including simultaneous high-voltage and lowvoltage battery charging. Finite-element and circuit simulations verify the magnetic characteristics and system operation, demonstrating the feasibility of the proposed unified architecture for EV charging applications.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

Electrostatic microvalves utilizing conductive nanoparticles for improved speed, lower power, and higher force actuation.

We have designed and built electrostatically actuated microvalves compatible with integration into a PDMS based microfluidic system. The key innovation for electrostatic actuation was the incorporation of carbon nanotubes into the PDMS valve membrane, allowing for electrostatic charging of the PDMS layer and subsequent discharging, while still allowing for significant distention of the valveseat for low voltage control of the system. Nanoparticles were applied to semi-cured PDMS using a stamp transfer method, and then cured fully to make the valve seats. DC actuation in air of these valves yielded operational voltages as low as 15V, by using a supporting structure above the valve seat that allowed sufficient restoring forces to be applied while not enhancing actuation forces to raise the valve actuation potential. Both actuate to open and actuate to close valves have been demonstrated, and integrated into a microfluidic platform, and demonstrated fluidic control using electrostatic valves.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

PV Cyber Security Research (Final Report)

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cyber security attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid support functions which can drastically influence power quality, voltage, and bulk system frequency. This project was split into two phases. The first provided a survey and roadmap of the cybersecurity for the solar industry. The second investigated multiple PV cybersecurity research and development (R&D) concepts identified in the first phase. In the first year, the team created a roadmap for improving cybersecurity for distributed solar energy resources. This roadmap was intended to provide direction for the nation over the next five years and focused on the intersection of industry and government and recommends activities in four related areas: stakeholder engagement, cyber security research and development, standards development, and industry best practices. At the same time, the team produced a primer for DER vendors, aggregators, and grid operators to establish a common taxonomy and describe basic principles of cyber security, encryption, communication protocols, DER cyber security recommendations and requirements, and device-, aggregator-, and utility-level security best practices to ensure data confidentiality, integrity, and availability. This material was motivated by the need to assist the broader PV industry with cybersecurity resilience and describe the state-of-the-art for securing DER communications. Lastly, an adversary-based assessment of multiple PV devices was completed at the Distributed Energy Technologies Laboratory at Sandia National Laboratories to determine the status of industry cybersecurity practices. The team found multiple deficiencies in the security features of the assessed devices. In the second year, a set of recommendations was created for DER communication protocols— especially with respect to the state-of-the-art requirements in IEEE 2030.5. Additionally, several cybersecurity R&D technologies related to communications-enabled photovoltaic systems were studied to harden DER communication networks. Specifically, the team investigated (a) using software defined networking to create a moving target defense system for DER communications, and (b) engineering controls that prevent misprogramming or adversary action on DER devices/networks by disallowing setpoints that will generate unstable power system operations.

14 SOLAR ENERGY↗

Operation Experience with DC Photoemission Guns at Jefferson Lab

The JLab IR FEL injector is driven by a DC photoemission electron gun based on GaAs photocathodes. Since the FEL commissioning in 1998, the DC gun has been rebuilt several times for improved performance and/or for repairs. After demonstrating 9 mA CW and over 7000 Coulombs at 350kV for three consecutive years, the gun was rebuilt in 2008 due to a punctured insulator. Since then, the gun has been operating at 325V (lower voltage due to field emission) and has delivered beam at 65 pC bunch charge for VUV FEL operations, and 135pC for IR FEL operations at beam currents up to 4 mA CW. In February 2011, a copy of that gun was tested in the Gun Test Stand with a partially conductive insulator from Wesgo/Morgan to study bulk conductivity as charge drain for preventing insulator puncture by field emission. Close to 300 hours of high voltage testing showed that processing of field emission with partial pressure of Krypton gas is very effective. The gun held 500kV over 8 hours with 1E-4 Torr of Krypton. However, the gun could not hold more than 440kV under vacuum conditions, at which set point the insulator suffered a puncture. Various observations of Kr processing behavior and voltage-induced gas desorption will be presented. Financial support was provided by the Office of Naval Research, the Army Night Vision Laboratory, the Air Force Research Laboratory, the Joint Technology Office, the Commonwealth of Virginia, and by the U.S. DOE Basic Energy Sciences under contract No. DE-AC05-060R23177.

Hernandez-Garcia, Carlos↗