Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage and current controllers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The Digital Mirror Langmuir Probe: Field Programmable Gate Array Implementation of Real-Time Langmuir Probe Biasing

High bandwidth, high spatial resolution measurements of electron temperature, density and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimised for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customisable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g. real-time control outputs, more voltage states) and scalability through collaboration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synchronverter-based Control of Multi-Port Autonomous Reconfigurable Solar Plants (MARS)

Control of integrated photovoltaic (PV) plants with energy storage systems (ESSs) has become an important research and development topic in recent times. In this context, a Multi-port Autonomous Reconfigurable Solar (MARS) plant that integrates PV and ESS to alternating current transmission grid and high-voltage direct current (HVdc) link is studied in this paper. With penetration of power electronic based resources in the grid, the grid’s capability to recover from frequency or voltage disturbances are reduced. Therefore, one of the vital objectives of any new grid integrated power electronic resource is to provide advanced control functions like voltage and frequency support to the grid during disturbances. In this research work, a detailed implementation of a synchronverter-based control algorithm of MARS is presented. The proposed control algorithm and the MARS control architecture are evaluated through simulations on PSCAD/EMTDC simulation platform to showcase the performance in different operating conditions. In addition, they are evaluated in Opal-RT offline simulation models which can also be used to perform control-hardware-in-the-loop (cHIL) tests.

Marthi, Phani Ratna Vanamali↗

Proton radiation resilience of CdSeTe photovoltaics: High predicted end-of-life performance for space applications

Two types of cadmium selenide telluride (CdSeTe) photovoltaic devices have been exposed to high-energy (150–1500 keV) protons with fluences ranging from 1 × 10 11 to 9 × 10 13 cm −2 . Pre- and post-irradiation current density vs voltage characteristic data were collected and analyzed. Arsenic-doped CdSeTe devices retained 80% of the power conversion efficiency (PCE) relative to control devices after exposure to 10 12 cm −2 650 keV protons, while copper-doped CdSeTe devices retained about 95% of the control PCE under the same irradiation condition. Displacement damage dose analysis coupled with simulations for duration-dependent performance in a medium Earth orbit space mission revealed superior PCE remaining factors, indicating greater resilience to proton bombardment than state-of-the-art multijunction III-V based space photovoltaic technologies.

CdTe solar cells↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Proton Radiation Tolerance of Wide and Narrow Band Gap Perovskite Solar Cells

Two different single junction mixed organic-inorganic halide perovskite solar cells (PSCs) were assessed for their tolerance to high energy proton radiation. Both the narrow band gap mixed tin-lead iodide and wide band gap lead iodide-bromide show remarkable tolerance for fluences up to 1x10 11 p/cm 2 . Both materials show a retention of open circuit voltage and decrease in dark current densities indicating minimal effect on SRH recombination that typically plagues traditional III-V based solar cells. Additionally, a control device that was processed without the perovskite absorber layer showed better diode characteristics and lower dark current densities after proton irradiation. The tolerance of these perovskite as a class of materials is promising for multijunction tandem flexible photovoltaic devices.

perovskite↗

Electron beam heating as a tool for fabricating lattice engineered crystals in glass [Invited]

Laser heating is well-established to impart optical functionality into glass by local modification and crystallization. In this paper, we demonstrate electron beam heating in scanning and transmission microscopes as an alternative for the local crystallization of Sb 2 S 3 in Sb-S-I glasses as a model system. Governed by different absorption physics, the electron beam expands morphological control of crystal cross section relative to laser, producing nanoscale (∼50 nm) single crystal architectures. We also report the effects of accelerating voltage and probe current and characterize the curved lattice of crystals formed in glass with electron diffraction techniques.

36 MATERIALS SCIENCE↗

Reinforcement Learning for Small Autonomous Ground Vehicle

Microcontroller: • ESP-WROOM 32 control board • Wi-Fi 802.11 b/g/n Actuators: • 2 Futaba S3003 Servos • Commanded angles of 0 to 180 • Effectors • Piano wire “legs” and “feet” • Current, Voltage, Power Sensor: • Adafruit INA260 • Range Finder (1D LiDAR) Sensor: • SparkFun VL53L1X • Power Supply: • Battery powered, Adafruit UN3480 Li Ion Polymer 1200 mAh • Adafruit JST 2 PH power breakout board • Body: • Additively manufactured frame

Wells, William Willie↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant: Preprint

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and Power System Stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It mitigates the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Controlled removal of hydrogen atoms from H-terminated silicon surfaces

The controlled formation of dangling bond structures on a H-terminated silicon surface is the first step in an atomically precise method of fabrication of silicon quantum electronic devices. An ultrahigh vacuum scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from a Si(100)-2x1:H surface by injecting electrons with the sample held at a positive bias voltage. The authors propose a lithography method that allows the STM to operate under negative bias imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative bias voltage to deliver the required energy for hydrogen removal. The resulting current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM’s feedback control loop. The authors show that the chance of tip-sample crash during the lithography process is reduced by employing this method. They also demonstrate that this approach offers a significant potential for controlled and precise removal of H atoms from a H-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

42 ENGINEERING↗

A distributed voltage inference framework for cyber-physical attacks detection and localization in active distribution grids

The transition to active distribution grids with real-time monitoring and control depends on the proliferation of advanced communication networks and devices. This paradigm shift towards a cyber-physical architecture also introduces new vulnerabilities for adversaries to exploit and launch sophisticated cyber-physical attacks targeting grid observability. Current research highlights the challenges in distinguishing attacks on voltage phasor or nodal injection measurements and isolating multi-source attack locations in a multiphase distribution grid. The attack detection and localization methods in literature face accuracy issues, applications across diverse attack scenarios, or scalability limits. Here, to bridge these gaps, this paper proposes a distributed Voltage Inference framework for real-time detection and localization of cyber-physical attacks, addressing scalability, adaptability, and accuracy challenges in state-of-the-art methods. The proposed methodology leverages the distributed nature of the Voltage Inference framework through a two-step process of prediction and correction, together with a tractable graph partitioning approach, providing a reliable solution to identify compromised measurement sources and facilitate isolation. Extensive testing on IEEE 13 and 123-node distribution feeders underscores the algorithm’s efficacy, enhancing the security and resilience of active distribution grids against evolving cyber threats. Additionally, Hardware-in-the-Loop (HIL) implementation validates the proposed strategy’s practical applicability in real-world scenarios.

active distribution grids↗

Privacy-Preserving Robust Consensus for Distributed Microgrid Control Applications

Consensus-based distributed control has been proposed for coordinating distributed energy resources (DERs) in microgrids (MGs). As one key component, distributed average observers are used to estimate the average of a group of reference signals (e.g., voltage, current, or power). State-of-the-art distributed average observers could lead to loss of privacy due to information exchange on the communication channels. The DERs' reference signals, which contain private information, could be inferred by an eavesdropper. In this article, a privacy-preserving distributed average observer is proposed that is based on robust consensus and uses the state decomposition method to preserve privacy. Compared to the existing methods, the proposed observer does not require the knowledge of the reference signal's derivative and gives accurate and smooth estimation, and is thus applicable for MG distributed control applications. A detailed analysis regarding the convergence and privacy properties of the proposed observer is presented. Here, the proposed observer is implemented on hardware controllers and validated in the context of distributed MG control applications through hardware-in-the-loop (HIL) tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An automated and portable method for selecting an optimal GPU frequency

Power consumption poses a significant challenge in current and emerging graphics processing unit (GPU) enabled high-performance computing systems. In modern GPUs, dynamic voltage frequency scaling (DVFS) appears to be a reliable control to regulate power consumption and performance. However, the DVFS design space is large - hence, brute-force approaches are infeasible to select the optimal frequency. Furthermore, no single frequency can be universally optimal for applications with varying computational intensities. Thus, the application's complexity and the availability of a wide range of frequency settings are a challenge in selecting the optimal frequency configuration for a given GPU workload. To that end, this paper proposes a systematic approach that consists of three steps. The feature characterization study identifies the fine-grain GPU utilization metrics that influence the power consumption and execution time of a given workload. To understand the performance, power, and energy consumption behaviors of a workload across GPU's DVFS design space, we derived analytical power and performance models using the identified fine-grain features. Here, it is shown that the same set of GPU utilization metrics can estimate both the power consumption and execution time while being agnostic of changes to frequency and input sizes. Applying a power control with the single objective of reducing power may cause performance degradation, leading to more energy consumption. A multi-objective approach is proposed to select the optimal GPU DVFS configuration for a workload that reduces power consumption with negligible degradation in performance. The evaluation was conducted using SPEC ACCEL benchmarks and three real applications - NAMD LAMMPS, and LSTM on NVIDIA GV100, GA100, and AMD MI210 GPUs. On average, real applications showed 29.6% energy savings with a performance loss of 5.2% on GA100 and 22.6% energy savings with a performance loss of 4.7% on GV100. Moreover, the proposed models are portable to real applications, GPU architectures, and vendors, and require metric collection at only the default frequency rather than all supported DVFS configurations. Additionally, we conducted a comparison between our models and the GPU assembly instructions (PTX)-based static models. The results revealed a significant reduction in the average error rates, with a decrease from 19.7% to 3.1% for power models and from 29.4% to 5.2% for performance models.

97 MATHEMATICS AND COMPUTING↗

Low-cost gradient amplifiers for small MRI systems

Here, we describe low-cost gradient amplifiers for small MRI systems, such as those based on small/medium permanent magnets. The requirements for MRI gradient amplifiers are quite similar to those of modestly priced audio stereo power amplifiers. Such amplifiers for sound service can be modified to be DC coupled, extending their response down to zero frequency, as needed for MRI gradient service. We describe such modifications to one unit (Samson Servo 600) and mention a commercially available modification of another. The 600 is capable of an output greater than ±8 A and ±60 V, much greater than our needs for a greenhouse MRI. Audio amplifiers can be used this way as controlled voltage (CV) gradient amplifiers, with acceptable performance because the gradient coils typically have short L/R time constants. Superior performance can be had by using a controlled current (CC) “front end”; the circuit of our simple front end is included. The complete 3-axis CC system costs about $1200.

47 OTHER INSTRUMENTATION↗

In-situ tunable giant electrical anisotropy in a grating gated AlGaN/GaN two-dimensional electron gas.

Materials with in-plane electrical anisotropy have great potential for designing artificial synaptic devices. However, natural materials with strong intrinsic in-plane electrical anisotropy are rare. We introduce a simple strategy to produce extremely large electrical anisotropy via grating gating of a semiconductor two-dimensional electron gas (2DEG) of AlGaN/GaN. We show that periodically modulated electric potential in the 2DEG induces in-plane electrical anisotropy, which is significantly enhanced in a magnetic field, leading to an ultra large electrical anisotropy. This is induced by a giant positive magnetoresistance and a giant negative magnetoresistance under two orthogonally oriented in-plane current flows, respectively. This giant electrical anisotropy is in situ tunable by tailoring both the grating gate voltage and the magnetic field. Our semiconductor device with controllable giant electrical anisotropy will stimulate new device applications, such as multi-terminal memtransistors and bionic synapses.

36 MATERIALS SCIENCE↗

Testing of Novel Semiconductor Opening Switches Using Magnetic Switching

The performance of semiconductor opening switch (SOS) diodes with different doping profiles is assessed with the primary aim of enhancing or substituting hard-to-find devices. SOS devices are capable of providing long lifetime, gigawatt level pulses in generators with risetimes on the nanosecond scale with pulse widths on the order of 20 ns. An experimental testbed is described which allows for rapid testing of diodes with control of the forward pumping time which is a crucial parameter of SOS diodes. A saturable pulse transformer provides both the initial voltage multiplication and reverse current pulse required to drive SOS diodes. Voltage multiplication ratios of 16:1 were achieved with a modest charging voltage of 800 V and simple circuitry. With current densities of up to 1.4 kA ⋅ cm -2 , the testbed produces 10 kV output pulses into a 56 Ω load with a pulsewidth of 16 ns and delivered power of up to 1.9 MW. These novel devices are compared to legacy SOS diodes originating from Russia, with one of the profiles yielding increased performance. Finally, these profiles are studied in hopes of creating manufacturing demand to augment the availability of these useful devices.

drift step recovery diodes↗

Grid-Assisted Direct-Current Magnetron Sputtering of Titanium: Plasma Discharge Diagnostics

Grid-assisted magnetron sputtering is attractive for the deposition of ultrathick Be coatings in inertial confinement fusion (ICF) applications because it offers improved control over the plasma. Here, we investigate the plasma discharge characteristics of grid-assisted direct current magnetron sputtering with Ti as a surrogate sputter target material instead of Be. We map the magnetic field of our magnetron source assembly, study the current-voltage characteristics of both the source and the substrate, and measure the energy distributions of ions bombarding the film surface during growth. The results reveal a slightly asymmetric magnetic field of the magnetron source array and strong dependencies of the plasma discharge characteristics on both the grid and the substrate voltages. Positive grid voltage increases both target and substrate currents, increases the plasma potential, and broadens the energy distributions of ions bombarding the substrate. Grid biasing effects on the plasma discharge characteristics and substrate current can be attributed to corresponding changes to the plasma potential, while substrate biasing effects are more complex and nonlinear. Furthermore, these results demonstrate that grid-assisted deposition offers additional flexibility in controlling the deposition process for tuning properties of ultrathick films for ICF applications.

ICF targets↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗