Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable energy generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Balancing renewable energy and river resources by moving from individual assessments of hydropower projects to energy system planning

As governments and non-state actors strive to minimize global warming, a primary strategy is the decarbonization of power systems which will require a massive increase in renewable electricity generation. Leading energy agencies forecast a doubling of global hydropower capacity as part of that necessary expansion of renewables. While hydropower provides generally low-carbon generation and can integrate variable renewables, such as wind and solar, into electrical grids, hydropower dams are one of the primary reasons that only one-third of the world’s major rivers remain free-flowing. This loss of free-flowing rivers has contributed to dramatic declines of migratory fish and sediment delivery to agriculturally productive deltas. Further, the reservoirs behind dams have displaced tens of millions of people. Thus, hydropower challenges the world’s efforts to meet climate targets while simultaneously achieving other Sustainable Development Goals. In this paper, we explore strategies to achieve the needed renewable energy expansion while sustaining the diverse social and environmental benefits of rivers. These strategies can be implemented at scales ranging from the individual project (environmental flows, fish passage and other site-level mitigation) to hydropower cascades to river basins and regional electrical power systems. While we review evidence that project-level management and mitigation can reduce environmental and social costs, we posit that the most effective scale for finding balanced solutions occurs at the scale of power systems. We further hypothesize that the pursuit of solutions at the system scale can also provide benefits for investors, developers and governments; evidence of benefits to these actors will be necessary for achieving broad uptake of the approaches described in this paper. We test this hypothesis through cases from Chile and Uganda that demonstrate the potential for system-scale power planning to allow countries to meet low-carbon energy targets with power systems that avoid damming high priority rivers (e.g., those that would cause conflicts with other social and environmental benefits) for a similar system cost as status quo approaches. We also show that, through reduction of risk and potential conflict, strategic planning of hydropower site selection can improve financial performance for investors and developers, with a case study from Colombia.

Opperman, Jeffrey J.↗

Variable frequency response testbed to validate protective relays up to 20 kHz☆

Microgrids operate in islanding or utility grid mode. In islanding mode, distributed energy sources with power electronics inverters can generate fault currents over a wide range of frequencies. To gain a better understanding of the nature of these events, it is crucial to measure currents at frequencies of up to 20 kHz at transient states with protective relays. Protective relays at these frequency responses should be tested prior to being installed in microgrids. However, testing at high-frequency currents cannot be done with Relay Test Equipment (RTE) that generate signals up to 50th Harmonic for 60 Hz (3 kHz). In this study, a frequency response method and testbed for high-frequency currents of up to 20.16 kHz was developed and tested. The testbed utilized a RTE and High-Frequency Power Source/ Amplifier. Furthermore, frequency relay experiments were run at frequencies of up to 1 and 20.16 kHz at a current magnitude of 0.1 and 0.5 A, respectively. The events were collected, and the current magnitude and frequency were plotted at time and frequency domain, respectively. The study of current magnitude and frequencies of up to 20.16 kHz for two overcurrent relays was performed and validated the variable frequency testbed and methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Energy Storage-Based Grid Forming Inverters for Operational Reserve in Hybrid Diesel Microgrids

In remote arctic communities, where access to a bulk electrical grid interconnection is not available, the implementation of islanded microgrids has been the most viable way to produce and distribute electricity services to their inhabitants. Historically, these islanded grids have relied primarily on diesel generators or hydropower resources to supply the baseload. However, this practice can result in increased expense due to the high costs associated with fuel transportation and the significant amounts of on-site storage necessary when fuel transportation is unavailable during winter months. In order to mitigate this problem, arctic microgrids have started to transition to a hybrid-source operational mode by incorporating renewable energy sources that are inherently variable in nature, such as wind or solar. Due to their highly stochastic behavior, these hybrid-source islanded microgrids can pose potential issues related to power quality due to introduction of rapid net load fluctuations and inability of diesel generators to respond rapidly. In addition, non-firm stochastic sources can require significant idling diesel generator resources to serve as spinning reserves, which is inefficient and wasteful. This work studies the problems that may arise in the transient dynamics of a real-world hybrid diesel microgrid when subjected to a loss of wind generation. Moreover, this work proposes a transition from a diesel spinning reserve to a battery energy-storage system (BESS) operating reserve scheme. The study of the proposed transition is important in establishing the fundamental implication of transient dynamics and the potential benefits of integrating a BESS as a spinning reserve in terms of stability, frequency nadir, and transient voltage deviation. The methods to investigate and validate the transient dynamics relied on both electromagnetic simulation models of GFMIs and a commercially available GFMI in an experimental power hardware-in-the-loop setup. The simulation results showed that the proposed operating reserve scheme improves the power quality of the system in terms of voltage deviation and frequency nadir when the microgrid is subjected to a loss of wind generation scenario. Depending on the simulation cases, adding a GFMI reduced the frequency nadir between 65.3% and 86.7%. Moreover, the reductions in the voltage deviations improved between 3.6% and 23.0%. From these results it can be concluded that the integration of a GFMI can reduce the frequency nadir in a hybrid diesel microgrid, and in turn, reduce diesel consumption, which improves system reliability while reducing fuel expenses. Furthermore, the novelty of this work relies on the fact that the offline simulation results were validated using a power hardware-in-the-loop platform that incorporated a 100 kVA commercially available GFMI as the device under test.

Hernandez-Alvidrez, Javier↗

Synergistic interactions between anammox and dissimilatory nitrate reducing bacteria sustains reactor performance across variable nitrogen loading ratios

Anaerobic ammonium oxidizing (anammox) bacteria are utilized for high efficiency nitrogen removal from nitrogen-laden sidestreams in wastewater treatment plants. The anammox bacteria form a variety of competitive and mutualistic interactions with heterotrophic bacteria that often employ denitrification or dissimilatory nitrate reduction to ammonium (DNRA) for energy generation. These interactions can be heavily influenced by the influent ratio of ammonium to nitrite, NH 4 + :NO 2 - , where deviations from the widely acknowledged stoichiometric ratio (1:1.32) have been demonstrated to have deleterious effects on anammox efficiency. Thus, it is important to understand how variable NH 4 + :NO 2 - ratios impact the microbial ecology of anammox reactors. We observed the response of the microbial community in a lab scale anammox membrane bioreactor (MBR) to changes in the influent NH 4 + :NO 2 - ratio using both 16S rRNA gene and shotgun metagenomic sequencing. Ammonium removal efficiency decreased from 99.77 ± 0.04% when the ratio was 1:1.32 (prior to day 89) to 90.85 ± 0.29% when the ratio was decreased to 1:1.1 (day 89–202) and 90.14 ± 0.09% when the ratio was changed to 1:1.13 (day 169–200). Over this same timespan, the overall nitrogen removal efficiency (NRE) remained relatively unchanged (85.26 ± 0.01% from day 0–89, compared to 85.49 ± 0.01% from day 89–169, and 83.04 ± 0.01% from day 169–200). When the ratio was slightly increased to 1:1.17–1:1.2 (day 202–253), the ammonium removal efficiency increased to 97.28 ± 0.45% and the NRE increased to 88.21 ± 0.01%. Analysis of 16S rRNA gene sequences demonstrated increased relative abundance of taxa belonging to Bacteroidetes, Chloroflexi, and Ignavibacteriae over the course of the experiment. The relative abundance of Planctomycetes, the phylum to which anammox bacteria belong, decreased from 77.19% at the beginning of the experiment to 12.24% by the end of the experiment. Analysis of metagenome assembled genomes (MAGs) indicated increased abundance of bacteria with nrfAH genes used for DNRA after the introduction of lower influent NH 4 + :NO 2 - ratios. The high relative abundance of DNRA bacteria coinciding with sustained bioreactor performance indicates a mutualistic relationship between the anammox and DNRA bacteria. Understanding these interactions could support more robust bioreactor operation at variable nitrogen loading ratios.

59 BASIC BIOLOGICAL SCIENCES↗

What can surface wind observations tell us about interannual variation in wind energy output?

The past decade of wind power growth was supported by capacity factor improvements and associated cost reductions. But are higher capacity factors a technology success story or, as suggested by recent research, has the influence of technology been overstated by ignoring positive surface wind speed trends? The answer could influence estimates of wind energy's cost and even future deployment rates. We find that US surface wind speed observations imply a 2.6% improvement in capacity factors from 2010 to 2019. Yet newer vintages of wind plants have recorded capacity factors that are ~25% larger than plants built close to 2010. It follows that technological factors and improved site quality, not higher wind speeds, drove most of the improvement in capacity factors. Additionally, we match hundreds of meteorological stations to nearby (< 25 km) wind plants and compare annual estimated generation, based on a function of surface wind speed observations, to annual recorded generation. Researchers rely on this publicly available surface data because measurements co-located with wind plants are generally considered proprietary. Our analysis addresses a research gap: interannual variation in observed surface wind speeds is rarely compared to observed data at wind plant locations and turbine heights. We find that despite its common use for this purpose, generation estimates based on publicly available surface observational data provide a poor proxy for interannual variability in recorded wind generation. These findings suggest that caution is generally needed when researchers use surface wind speed measurements to investigate long-term wind energy trends.

17 WIND ENERGY↗

Empirical Indicators of Transmission Value in the Southeast United States

Concurrent differences in energy price between different parts of the electric grid are a key indicator of the value of additional transmission. In areas without a wholesale electricity market, such as the Southeast, an alternative indicator to price is the Federal Energy Regulatory Commission’s (FERC) system lambda data. This economic metric represents the minimized marginal production costs of thermal generators, including fuel and other variable operation and maintenance expenses. Balancing Authorities report a single system lambda for their entire balancing area. Most Southeastern lambdas exhibit sufficient price variation to support a transmission valuation analysis, although incomplete accounting of congestion costs or scarcity rents during peak load hours may underestimate the true value of transmission capacity. With transmission value defined as the annual average hourly absolute price difference between two regions and FERC’s system lambda data used as a price proxy, we find the following results in the Southeast region during 2012-2023 (reported in $\$2024$/MWh): Intra‐regional findings: Annual averages historically span $\$2$–$\$28$/MWh and average $\$12$/MWh in SERTP and span $\$4$–$\$19$/MWh and average $\$9$/MWh in FRCC, disregarding transmission value driven by anomalous data. The ranges of transmission value reported here are large, spanning an order of magnitude in some cases. Much of this variation is driven by year-to-year changes, with 2022 having a particularly high intra-regional transmission value due to elevated natural gas prices. Inter‐regional corridors: Annual average transmission values across three broader regions range from $\$6$ to $\$28$/MWh with a long-term average of $\$11$/MWh. Much of the transmission value is concentrated in a small portion of hours. Across all regions, severe weather—particularly polar vortex events in January 2018, February 2021, and December 2022—drives the largest price spreads. Seasonal patterns also emerge, with summer afternoons and fall mornings contributing consistently to transmission value, as for example between MISO and SOCO in 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AC Power Flow Based DLMP Calculation and Decomposition Method to Smooth Power Fluctuation of Distributed Renewable Energy Sources

As the penetration of renewable energy sources increases, the growing renewable power variability brings ramping issues to power systems. Meanwhile, the development of distributed energy resources (DERs) makes the distribution systems to provide both energy and ancillary services. To incentivise individual resources and customers to alleviate ramping issues on the demand side, a two-stage distribution locational marginal price (DLMP) calculation and decomposition method is developed to formulate the marginal power ramping price for DERs. In the first stage of the proposed method, a distribution system operator market scheduling model based on AC optimal power flow is designed to estimate the optimal operating point of the distribution system. Subsequently, the voltage and power flow constraints are linearised in stage two to calculate DLMP. Finally, based on the Lagrange function and sensitivity factors, DLMP is decomposed to the marginal costs for active/reactive power, voltage management, power loss and power variability. Case studies demonstrate that the proposed model can effectively smooth the power fluctuation and reduce the ramping flexibility requirements of distribution systems.

AC optimal power flow↗

Refining fast calorimeter simulations with a Schrödinger Bridge

Machine learning-based simulations, especially calorimeter simulations, are promising tools for approximating the precision of classical high energy physics simulations with a fraction of the generation time. Nearly all methods proposed so far learn neural networks that map a random variable with a known probability density, like a Gaussian, to realistic-looking events. In many cases, physics events are not close to Gaussian and so these neural networks have to learn a highly complex function. We study an alternative approach: Schrödinger bridge Quality Improvement via Refinement of Existing Lightweight Simulations (SQuIRELS). SQuIRELS leverages the power of diffusion-based neural networks and Schrödinger bridges to map between samples where the probability density is not known explicitly. We apply SQuIRELS to the task of refining a classical fast simulation to approximate a full classical simulation. On simulated calorimeter events, we find that SQuIRELS is able to reproduce highly non-trivial features of the full simulation with a fraction of the generation time.

Calorimeter methods↗

Unsupervised quantum circuit learning in high energy physics

Unsupervised training of generative models is a machine learning task that has many applications in scientific computing. Here, in this work, we evaluate the efficacy of using quantum circuit-based generative models to generate synthetic data of high energy physics processes. We use nonadversarial, gradient-based training of quantum circuit Born machines to generate joint distributions over two and three variables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mechanical and Thermal Forcing for Upslope Flows and Cumulus Convection over the Sierras de Córdoba

Abstract The upslope flow processes affecting the vertical extent of orographic cumulus convection are examined using observations from the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign. Specifically, clear air returns from the U.S. Department of Energy (DOE) second-generation C-band scanning Atmospheric Radiation Measurement (ARM) precipitation radar (CSAPR2) are used to characterize the structure and variability of the ridge-normal (i.e., up/downslope) flow components, which transport mass to the crest of Argentina’s Sierras de Córdoba and contribute to convective initiation. Data are compiled for the entire CACTI period (October–April), including days with clear skies, shallow cumuli, cumulus congestus, and deep convection. To examine shared variability among >70 000 radar scans, we use (i) a principal component analysis (PCA) to isolate modes of variability in the upslope flow and (ii) composite analysis based on convective outcomes, determined from GOES-16 satellite observations. These data are contextualized with observed surface sensible heat fluxes, thermodynamic profiles, and synoptic-scale analysis. Results indicate distinct thermally and mechanically forced upslope flow modes, modulated by diurnal heating and synoptic-scale variations, respectively. In some instances, there is a superposition of thermal and mechanical forcing, yielding either deeper or shallower upslope flow. The composite analyses based on satellite data show that successively deeper convective outcomes are associated with successively deeper upslope flow layers that more readily transport mass to the ridge crest in conjunction with lower lifting condensation levels, facilitating convective initiation. These results help to isolate the forcing mechanisms for orographic convection and thus provide a foundation for parameterizing orographic convective processes in coarse resolution models.

Meteorology & Atmospheric Sciences↗

Alternating Direction Decomposition with Strong Bounding and Convexification (ADDSBC) for Solving Security Constrained AC Unit Commitment Problems

This project aims to develop efficient and robust computational methods for solving the security-constrained unit commitment and alternating current optimal power flow problem (SC-UC-ACOPF). The SC-UC-ACOPF problem is at the center of the short-term operation of the U.S. Power Grid. It is solved every week, every day, and every 10 minutes to plan for the optimal action of electricity generation and consumption by minimizing the generation cost and maintaining power system reliability against potential disruptions of equipment failures. In mathematical terms, SC-UC-ACOPF is a challenging large-scale mixed-integer nonlinear optimization model. This means that the decisions involve both discrete variables, e.g. the turning on and off of generators and switching of transmission lines and transformers, and continuous decisions, e.g. the amount of energy generated by each generator and the power flows in the power grid. The physics of the power flow is described by nonlinear equations involving real and reactive power and bus voltages. Another key feature is the large number of contingencies, i.e. the system needs to stay reliable in face of failure of any one equipment, such as transmission lines and generators. The U.S. power grids are extremely complicated and large scale with more than 5,000 generators, 50,000 buses, and 100,000 high-voltage transmission lines, making the SC-UC-ACOPF a very large-scale computation challenge. The research developed in this project aims to solve the SC-UC-ACOPF problems in the three timescales, i.e. weekly, daily, and every 10-min. The proposed computational methods are built on a principled algorithmic approach of decomposition and penalization. More specifically, the algorithm develops spatial and temporal decomposition by exploiting the strong temporal coupling and weak spatial coupling of the UC problem and the complementary feature, i.e. weak temporal coupling and strong spatial coupling of the ACOPF problem. The algorithm also leverages recent progresses in strong convex relaxation of ACOPF. A unique feature of the proposed approach is that it generates a valid, global upper bound on the optimal maximum profit. In this way, a global optimality gap is available to measure the quality of the solution. To further speed up computation, the research team has developed a plethora of effective heuristics to strengthen the iterative penalty-based decomposition framework. For instance, a heuristic is developed to construct inner approximations of the time coupling constraints within the time decoupled problems. Contingencies are pre-screened and low-rank matrix computation is exploited to find the almost unique solution to each contingency. A novel heuristic for line switching is proposed and tested with positive impacts on instances where line switching is beneficial. Taking a systematic approach and carefully handling every detail of the problem pays off. The TIM-GO’s performance throughout the trials and the final event was stellar. TIM-GO garnered the second highest total prize money and is ranked in the top three positions across all categories of comparison.

97 MATHEMATICS AND COMPUTING↗

Modeling a Lead-Cooled Fast Reactor with Thermal Energy Storage using Optimal Dispatch and SAM

Increased contributions from wind and solar energy have helped set the United States on an attainable pathway towards carbon-free energy production. Though renewable energy is pivotal for this goal, saturating the grid with these variable energy sources has its challenges. Resources for wind and solar vary from factors beyond human control, hence the power output from these energy generators doesn’t necessarily match power demand for a specific region at a given moment in time. Solar photovoltaic production has a drastic mismatch since the peaks for power demand and power production are often out of phase: production peaks with available irradiance while demand peaks during the morning and evening hours. This “duck curve” in energy demand, the difference between high and low demand, grows as the grid becomes more saturated with renewable energy providers.

Soto, Gabriel J.↗

To What Extent Will Decarbonization Deepen the Conversation Between Industry and the Grid?

Decarbonization - the transition away from un-mitigated fossil fuel combustion throughout the economy - requires big changes from both power and process systems. On the power system side, those changes are expected to include large increases in variable generation, e.g., from wind and solar, which has near-zero marginal costs and at large shares can produce infrequent but consequential energy droughts. On the process systems side, industries are investigating their options for direct and indirect electrification, the latter exemplified by replacing fossil fuel inputs with zero-carbon, energy-carrying chemicals like hydrogen and ammonia produced via electrochemical processes. The economic features of these changes within the larger context of power and process systems suggest that their realization could be accompanied by a paradigm shift in how industrial facilities interact with the grid. For example, the dominant type of demand participation in power markets could change from today's focus on load reductions at peak times to a new focus on shifting electricity use, enabled in part by large-scale product storage, to take advantage of renewable energy that would otherwise be curtailed and to avoid consumption during high-price energy droughts. This talk will describe these and other possible design and operational approaches from grid and industrial economic perspectives, culminating in an enumeration of open problems that lie at the interface of today and tomorrow's power and process systems.

co-design↗

Building energy efficiency and load flexibility optimization using phase change materials under futuristic grid scenario

This work investigates the energy savings and load flexibility capacity of phase change material (PCM) integrated into building envelope under a future energy generation scenario, where 80% of the energy load comes from renewable sources. Using community-scale modeling, we first determine the net thermal storage required to fully manage the demand variability at a utility grid, and then using whole-building simulations we optimize operating parameters - such as PCM thickness, latent heat, interior setpoint profile, PCM distribution, and heat transfer coefficient - to determine the optimal conditions required for maximum energy reduction and load flexibility without compromising occupants' thermal comfort. The optimal PCM-integrated envelope proposed in this study can provide annual load flexibility up to 33.6% and annual energy savings up to 10.8% in a lightweight residential building located in Baltimore, MD. This study is relevant given the increasing contributions of renewable energy in the total energy generation mix, leading to a significant time-imbalance between peak energy demand and peak energy production. While thermal energy storage using PCM is a recognized technique, there is no known prior study dedicated to examining the thermal performance of PCM-integrated envelope under future energy generation scenarios. This study bridges the research gap by investigating a practical way to implement PCMs in the buildings and maximize the energy efficiency as well as load flexibility related benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 9: Impact of Variable Renewable Energy Sources on Bulk Power System Planning and Operations

Wind and solar photovoltaics (PV) have experienced remarkable growth in recent years, with many consequent benefits within and outside of power systems. At the same time, wind and solar PV have unique characteristics relative to the historically dominant dispatchable technologies like coal, gas, and nuclear power plants that have required and will continue to require changes in power system planning and operations. This chapter discusses planning and operational challenges of integrating wind and solar PV into bulk power systems. We first present the key characteristics of wind and solar PV that differentiate it from conventional technologies, such as variable and uncertain electricity generation, asynchronous interconnection to the power system, and near-zero marginal costs. We then link these characteristics to power system planning and operational challenges at low through high wind and solar penetrations. Finally, we discuss near- and long-term solutions to those challenges, such as diversifying the generation mix and wind and solar fleets, improving system flexibility, diversifying ancillary service products, and integrating generation and transmission planning.

bulk power system↗

Rethinking the Role of Financial Transmission Rights in Wind-Rich Electricity Markets in the Central U.S.

Transmission congestion can cause a divergence between wholesale power prices at the individual pricing nodes where power is generated and the more-liquid trading hubs where that power is often delivered and sold. This nodal price difference is commonly referred to as the “locational basis” (or just “basis”). Because the basis varies over time, it can—if not hedged—unpredictably affect a wind plant’s revenue and/or value, which increases investor risk and potentially slows deployment. We find wind plants typically face a larger and more-negative basis than do thermal generators, and hence are more-negatively impacted by congestion. Moreover, while most thermal generators can effectively hedge basis risk by purchasing conventional fixed-volume financial transmission rights (FTRs), these fixed-volume FTRs do not effectively hedge basis risk for variable wind generation. More-effective hedging mechanisms may be required to support those generators most-impacted by congestion, and to promote continued investment in variable generation resources in congested markets.

17 WIND ENERGY↗

A Hierarchical Volt-var Optimization with Discrete Variables in Unbalanced Distribution Systems

This paper proposes a framework to determine the optimal active and reactive power dispatch of distributed photovoltaic (PV) generation, switched capacitors, and voltage regulators in multi-phase unbalanced distribution systems. The objectives of the optimal dispatch are minimization of the energy loss, PV real power curtailment, and switching operations of capacitors and voltage regulators, in addition to elimination of voltage violation and reverse power flow. The optimization problem is formulated in rectangular coordinates as a nonlinear, nonconvex problem with discrete variables. A hierarchical twostage framework is proposed to effectively handle those discrete variables and reduce the computational time compared to the unified approach in which all variables are solved simultaneously. The efficacy of the proposed approach and the accuracy of the obtained numerical solution is validated using the unbalanced multi-phase IEEE 34-bus with 15-minute load and PV data.

Nguyen, Quan H.↗

Optimal, Reliable Building-Integrated Energy Storage (Cooperative Research and Development Final Report)

The team will advance the commercial readiness of behind-the-meter (BTM) energy storage (ES) systems by employing health-conscious controls that guarantee lifetime and optimize the ES system's value stream when integrated with onsite renewable energy generation. Specifically, the team will develop ES controls that increase the net present value (NPV) of photovoltaics (PV) by 50% in markets where net-metering policies are being replaced by variable electricity pricing structures. The team will also reduce the risk of achieving a 10-year ES warranty lifetime by at least one order of magnitude. The successful two-year project will develop the controls and system enabling Eaton to commercialize the technology by 2021. The developments achieved through this project may enable wide scale adoption of stationary energy storage benefitting the public.

25 ENERGY STORAGE↗