Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “undulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Undulator Radiation Generated by a Single Electron

The facilities providing single electron beams are currently being commissioned at Fermilab and will be at SLAC. Recently, Fermilab’s IOTA ring routinely demonstrated circulation of a single electron at 100 MeV beam energy. Alternatively, SLAC is working on constructing LCLS-II an X-ray FEL driven by a 4 GeV SRF linac. A parasitic beamline, S30XL, is planned that will extract 4 GeV dark current from between the primary LCLS-II electron bunches. The dark current will be delivered to End Station A and can work independently of LCLS-II experiments. The dark current will be bunched at a frequency of 46 MHz while extracted current varied from single electrons to 10’s of nA. In the present paper, we estimate the feasibility of propagating single electron beams through a conventional undulator, placed in the IOTA and S30XL beamlines. We explore the possible observable effects and experimental parameters range. In addition, we focus on potential applications of such beams in systems for high fidelity quantum measurements.

43 PARTICLE ACCELERATORS↗

Observation of Undulator Radiation Generated by a Single Electron Circulating in a Storage Ring and Possible Applications

An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.

43 PARTICLE ACCELERATORS↗

Undulator radiation of single electrons: coherence length and quantum-optical properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

OPERATIONAL EXPERIENCE WITH FAST FIBER-OPTIC BEAM LOSS MONITORS FOR THE ADVANCED PHOTON SOURCE STORAGE RING SUPERCONDUCTING UNDULATORS

Fast fiber-optic (FFO) beam loss monitors (BLMs) installed with the first two superconducting undulators (SCUs) in the Advanced Photon Source storage ring have proven to be a useful diagnostic for measuring deposited charge (energy) during rapid beam loss events. The first set of FFOBLMs were installed outside the cryostat of the short SCU, a 0.33-m long device, above and below the beam centerline. The second set are mounted with the first 1.1-mlong SCU within the cryostat, on the outboard and inboard sides of the vacuum chamber. The next 1.1-m-long SCU is scheduled to replace the short SCU later in 2016 and will be fitted with FFOBLMs in a manner similar to original 1.1-m device. The FFOBLMs were employed to set timing and voltage for the abort kicker (AK) system. The AK helps to prevent quenching of the SCUs during beam dumps [1] by directing the beam away from the SC magnet windings. The AK is triggered by the Machine Protection System (MPS). In cases when the AK fails to prevent quenching, the FFOBLMs show that losses often begin before detection by the MPS.

Dooling, J.↗

OPERATIONAL EXPERIENCE WITH BEAM ABORT SYSTEM FOR SUPERCONDUCTING UNDULATOR QUENCH MITIGATION*

A beam abort system has been implemented in the Advanced Photon Source storage ring. The abort system works in tandem with the existing machine protection system (MPS), and its purpose is to control the beam loss location and, thereby, minimize beam loss-induced quenches at the two superconducting undulators (SCUs). The abort system consists of a dedicated horizontal kicker designed to kick out all the bunches in a few turns after being triggered by MPS. The abort system concept was developed on the basis of single- and multi-particle tracking simulations using elegant and bench measurements of the kicker pulse. Performance of the abort system—kick amplitudes and loss distributions of all bunches—was analyzed using beam position monitor (BPM) turn histories, and agrees reasonably well with the model. Beam loss locations indicated by the BPMs are consistent with the fast fiber-optic beam loss monitor (BLM) diagnostics described elsewhere [1,2]. Operational experience with the abort system, various issues that were encountered, limitations of the system, and quench statistics are described.

Harkay, Katherine C.↗

Study of Fluctuations in Undulator Radiation in the IOTA Ring at Fermilab

We study turn-by-turn fluctuations in the number of emitted photons in an undulator, installed in the IOTA electron storage ring at Fermilab, with an InGaAs PIN photodiode and an integrating circuit. In this paper, we present a theoretical model for the experimental data from previous similar experiments and in our present experiment, we attempt to verify the model in an independent and a more systematic way. Moreover, in our experiment we consider the regime of very small fluctuation when the contribution from the photon shot noise is significant, whereas we believe it was negligible in the previous experiments. Accordingly, we present certain critical improvements in the experimental setup that let us measure such a small fluctuation.

43 PARTICLE ACCELERATORS↗

Undulator Field Integral Measurements

The LCLS undulator field integrals must be very small so that the beam trajectory slope and offset stay within tolerance. In order to make accurate measurements of the small field integrals, a long coil will be used. This note describes the design of the coil measurement system.

43 PARTICLE ACCELERATORS↗

Air Temperature in the Undulator Hall

Various analyses have been performed recently to estimate the performance of the air conditioning (HVAC) system planned for the Undulator Hall. This reports summarizes the results and provides an upgrade plan to be used if new requirements are needed in the future. The estimates predict that with the planned loads the tunnel air temperature will be well within the allowed tolerance during normal operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Triggering for Magnetic Field Measurements of the LCLS Undulators

A triggering system for magnetic field measurements of the LCLS undulators has been built with a National Instruments PXI-1002 and a Xylinx FPGA board. The system generates single triggers at specified positions, regardless of encoder sensor jitter about a linear scale.

43 PARTICLE ACCELERATORS↗

On the Kinematics of Undulator Girder Motion

The theory of rigid body kinematics is used to derive equations that govern the control and measurement of the position and orientation of undulator girders. The equations form the basis of the girder matlab software on the LCLS control system. The equations are linear for small motion and easily inverted as desired. For reference, some relevant girder geometrical data is also given. Equations 6-8 relate the linear potentiometer readings to the motion of the girder. Equations 9-11 relate the cam shaft angles to the motion of the girder. Both sets are easily inverted to either obtain the girder motion from the angles or readings, or, to find the angles and readings that would give a desired motion. The motion of any point on the girder can be calculated by applying either sets of equations to the two cam-planes and extrapolating in the z coordinate using equation 19. The formulation of the equations is quite general and easily coded via matrix and vector methods. They form the basis of the girder matlab software on the LCLS control system.

43 PARTICLE ACCELERATORS↗

Resistive wall heating due to image current on the beam chamber for a superconducting undulator

The image-current heating on the resistive beam chamber of a superconducting undulator (SCU) was calculated based on the normal and anomalous skin effects. Using the bulk resistivity of copper for the beam chamber, the heat loads were calculated for the residual resistivity ratios (RRRs) of unity at room temperature to 100 K at a cryogenic temperature as the reference. Then, using the resistivity of the specific aluminum alloy 6053-T5, which will be used for the SCU beam chamber, the heat loads were calculated. An electron beam stored in a storage ring induces an image current on the inner conducting wall, mainly within a skin depth, of the beam chamber. The image current, with opposite charge to the electron beam, travels along the chamber wall in the same direction as the electron beam. The average current in the storage ring consists of a number of bunches. When the pattern of the bunched beam is repeated according to the rf frequency, the beam current may be expressed in terms of a Fourier series. The time structure of the image current is assumed to be the same as that of the beam current. For a given resistivity of the chamber inner wall, the application of the normal or anomalous skin effect will depend on the harmonic numbers of the Fourier series of the beam current and the temperature of the chamber. For a round beam chamber with a ratius r, much larger than the beam size, one can assume that the image current density as well as the density square, may be uniform around the perimeter 2πr. For the SCU beam chamber, which has a relatively narrow vertical gap compared to the width, the effective perimeter was estimated since the heat load should be proportional to the inverse of the perimeter.

43 PARTICLE ACCELERATORS↗

A Method of Optimizing Field Roll-Off and the Peak Field of Hybrid Planar Undulators

Two new advancements have recently been made concerning hybrid planar undulator design. The first finding is how precisely the field roll-off in the x-direction can be controlled by altering the pole’s xy chamfer dimension. The second finding is how effectively the peak field can be increased by use of a large pole xx chamfer. The detailed field calculations regarding these pole chamfers are reported in this technical note.

Abliz, Melike↗

Calculated Shims' Signatures with the 17.2 mm Period New Undulator

In order to prepare some proper shims for the tuning of the upcoming new 17.2 mm period undulator, an investigation on the shims’ signatures with the device was done. The right dimensions of some typical shims were decided based on the calculation results for this device’s tuning. The detailed calculations of the shims’ signatures will be reported in this technical note.

Abliz, Melike↗

Magnetic Tuning of 2.8 min In-Vacuum Undulator

This report presents the magnetic tuning results and the final magnetic performance of the In-Vacuum Undulator 2.8 m S/N A13006. In order to improve the magnetic field quality in term of phase error and to reduce the field integral errors as well as the multipole field errors, different inhouse corrections have been carried out with Neomax's engineers. Although the vendor’s data were found satisfactory, the discrepancy between their magnetic field measurement results and BNL’s was not acceptable both for field integrals and phase error [1].

36 MATERIALS SCIENCE↗

Magnetic Characterization and Tuning of a Mini-Gap In-Vacuum Undulator X25 for NSLS-II

Designed and built by ADC USA Inc. a Mini-Gap In-Vacuum Undulator (MGU X25) has been employed for almost 10 years at NSLS in the Macromolecular Crystallography X25 beamline [1]. The device is a useful and almost readily available X-ray source for NLSL-II beamline, therefore it was extracted in early 2014 from the NSLS X-ray ring after its decommissioning. The Micro-diffraction beamline (NYX) at NSLS-II will utilize the X25-MGU as a bright and tunable X-ray source over the photon range of 5- 20 KeV in the short cell 19-ID. However, the NSLS-II electron beam properties are significantly different from the NSLS ones and the field integral requirements to be met by NSLS-II IDs are more stringent. Consequently, the device was brought to the NSLS-II ID lab for magnetic tuning. It is also a unique opportunity to characterize the magnetic performance of an ID after 10 years of operation in a storage ring.

36 MATERIALS SCIENCE↗

Repair and Retuning of 3-m long In-Vacuum Undulator at NSLS-II

A 3.0 m long In-Vacuum Undulator (IVU) is employed at the National Synchrotron Light Source II (NSLS-II) for the Hard X-ray Nanoprobe (HXN) beamline providing structural and X-ray fluorescence imaging with world-leading spatial resolution. On July 1st 2018 a gearbox shaft in the gap drive train assembly sheared due to corrosion fatigue caused by stress due to mechanical misalignment. The device was extracted from the storage ring and measured. The magnetic field measurements detected a degradation of the magnetic performance as well as a localized demagnetization of the magnetic modules of the first 3 upstream periods. This paper describes the mechanical repairs and the magnetic phase shimming optimization implemented to restore the spectral performance of the device.

36 MATERIALS SCIENCE↗

Study of Fluctuations in Undulator Radiation in the IOTA Ring at Fermilab [Slides]

Quantitative theoretical model for the experiment from was developed and verified in an independent experiment in IOTA. It helped corroborate a model of intrabeam scattering in IOTA. The agreement is expected to improve in the future. It was shown that along with measurements of longitudinal bunch size the fluctuations can be used to measure transverse bunch size in some cases (e.g., in IOTA). Improvements as compared to the similar experiment: Better precision due to using the comb filter with one-turn delay and the special noise subtraction algorithm. In IOTA, fluctuations were two orders of magnitude smaller. Fluctuations data were collected for different values of bunch charge. The transition from Poisson statistics to Super-Poisson statistics was observed in undulator radiation for the first time.

43 PARTICLE ACCELERATORS↗

Measurement of Spontaneous Undulator Radiation Statistics Generated by a Single Electron (URSSE)

As previously stated in the experiment proposal [1], the goal of the URSSE experiment was to study statistical properties of the undulator radiation generated by a single electron, circulating inthe IOTA storage ring. Namely, the idea was to study the distribution of the number of photons detected in a certain time window, and the distribution of the inter-arrival times of the photons. We wanted to see if the photostatistics was exactly Poissonian, as predicted or if there was some deviation towards Sub-Poissonian light, similar to what was observed in another study.

43 PARTICLE ACCELERATORS↗