Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Task Time Tracker

This client-side web app tracks the amount of time spent on arbitrary tasks. It allosw the creation of an unlimited number of arbitrarily named tasks ans via simple interactions, tracks the amount of time spent working on the drfined tasks.

Cleary, G.↗

Sandia Cyber Omni Tracker

SCOT cyber security team enhancement tool that coordinates activities, captures knowledge, and serves as a platform to automate time-consuming tasks that a cyber security team needs to perform in its daily operations.

Nick Peterson, ToddBruner↗

Commercial Fleet Level Emissions and Energy Tracker (COFLEET) v1.0

This tool generates the latest US commercial vehicle fleet composition and operational characteristics using 2021 US VIUS data and assess the fleetwide energy and emission outcomes. The emission rates for commercial trucks and default fleet composition are collected from the U.S. EPA's MOtor Vehicle Emission Simulator (MOVES4). The 2021 US VIUS data is applied to generate fleet characteristics such as the long-haul fraction and the vehicle mileage accumulation rate. The tool also provides fleet turnover and emission forecasts under various forecasted fleet electrification scenarios. This tool helps policymakers and practitioners advance the commercial fleet generation for emission models. This study also provides some sample datasets for state and local transportation/air quality agencies to test, which can reduce the estimation bias associated with using MOVES default fleets.

Xu, Xiaodan [Lawrence Berkeley National Laboratory↗

CLAS12 Silicon Vertex Tracker Module Test

This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory and the experimenters of CLAS12 collaboration who have committed to participate in beam tests to be carried out during the 2013-2014 Fermilab Test Beam Facility program.

43 PARTICLE ACCELERATORS↗

T-1042: Muon g-2 Straw Tracker

The new g-2 experiment is being constructed to improve on the current value measured at Brookhaven. One of the factors contributing to the improved understanding of systematic errors is a straw chamber that sits in the vacuum, close to the muon beam. These chambers can be used for a parasitic Electric dipole moment measurement, improved understanding of the beam dynamics and will improve the pile up library for the calorimeter. The chambers being built will consist of doublet U-V layers (with 15° between layers). The straws are made of wound mylar. One layer consists of 500 angstroms of aluminum on top of the mylar (the outside) and the other layer has 500 angstroms aluminum plus 200 angstroms of gold on the mylar. The two strips are wound together to make a straw. The straws will have a 25 micron gold plated tungsten wire in the middle at high voltage (~1400V) as the sense wire. A gas consisting of 80-20 Ar-C0 2 will be flowed through the straws. This will be a 32 channel prototype consisting of straws that are 9cm long.

Rominsky, Mandy↗

The Top Quark Mass, Systematic Limitations, and my Tracker-Driven Measurements

Top quark mass measurements have achieved an unexpected level of accu- racy in the last several years. This accuracy is only possible because of a new procedure that calibrates away the dominant jet energy uncertainty of past mea- surements. In this thesis I present some studies illustrating my suspicions that this procedure is leading them to claim overly optimistic results. Additionally, I present three measurements of the top quark mass that will be almost entirely independent of jet energies, and will thus serve as important cross checks of the standard measurements once enough statistics have been collected. I perform my measurements of the top quark mass in the lepton plus jets channel with approximately 1.9 fb -1 of integrated luminosity collected with the CDF detector using quantities with minimal dependence on the jet energies. One measurement exploits the transverse decay length of b-tagged jets to determine a top quark mass of 166.9+9.5 (stat)±2.9 (syst) GeV/c 2 , and another the transverse momentum of electrons and muons from W decays to determine a top quark mass of 173.5+8.8 - (stat) ± 3.8 (syst) GeV/c 2 . I combine these quantities in a vi third, simultaneous mass measurement to determine a top quark mass of 170.7 ± 6.3 (stat) ± 2.6 (syst) GeV/c 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-contact Mirror Measurements by a Laser Tracker

In my previous experience, beam line optics measurement is directly or semi-directly done by moving SMR along its surface. The fact there is that the touchable part is not critical to the mirror’s future use. But now for NSLSII project, we have to deal with the no-touch-at- all-to-the-surface situation. The following is a general idea of how to measure a mirror without contact its precision surface, further test need to be done to verify it.

36 MATERIALS SCIENCE↗

Non-contact Mirror Measurement by a Laser Tracker

In my previous experience, beam line optics measurement is directly or semi-directly done by moving SMR along its surface. The fact there is that the touchable part is not critical to the mirror’s future use. But now for NSLSII project, we have to deal with the no-touch-at-all-to-the-surface situation. The following is a general idea of how to measure a mirror without contact its precision surface, further test need to be done to verify it.

36 MATERIALS SCIENCE↗

Laser Transport Vacuum Simulations and LED Atom Tracker

MAGIS-100 uses atom interferometry to measure the distance between the Sr atoms traversing the shaft. The laser must travel through vacuum to measure accurately. Project ensures the vacuum system has low enough pressure to meet experimental requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracker Fits for shot 1s1674

Gas gun shock-to-detonation experiments provide data for calibrating HE burn models. At LANL the principal diagnostic is a magnetic gauge package that provides data on the lead shock trajectory, which is used to determine the run-distance to detonation, and the lead shock speed with run distance, which together with jump-off velocity of the velocity gauges determines Hugoniot locus points for the reactants.

42 ENGINEERING↗

A High Voltage Distribution System for the Mu2e Electron Tracker

This paper describes the design and development of a High Voltage distribution system (Smart Switch - SS) which distributes one input high voltage (HV) into six High Voltage channels (HVDS) of a straw detector plane. The SS independently sets, controls, and monitors the HV to each individual channel of a straw-detector plane in the Mu2E Electron Tracking Detector. Each straw plane is composed of three 120 deg crescent-shaped panels, and each panel is composed of 96 straw-tube detectors. Each output channel of the SS has independent, ON-OFF, current and HV monitoring, as well as filtration, isolation, and a crowbar to provide overcurrent protection for in that channel. The inter-communication system is based on TCP/IP protocol using a Raspberry Pi. The HVDS meets all required specifications including long term stability, accurate monitoring of the HV and current, and overcurrent trip. The performance of the HVDS was found to be comparable to, if not better than, commercial HV power supplies.

42 ENGINEERING↗

Survey of AC-LGADs for future 4D trackers with a proton beam

We will present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility, and a study of the performance of AC-LGAD sensors as a function of their thickness. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. Long strip sensors with sparse readout offer better cost and performance for applications where channel count or electrical power density is a constraint. Thanks to the excellent signal to noise ratio in AC-LGADs, sparse readout can be exploited without significant degradation of spatial or time resolution, which is demonstrated in our studies. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. We will present our studies of the sensor geometry optimizatio n to maintain the desirable sensor performance characteristics with increasingly larger electrodes.

43 PARTICLE ACCELERATORS↗