Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The Belle II imaging Time-of-Propagation (iTOP) Detector

High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector that will take data at the SuperKEKB accelerator. With 40x the luminosity of KEKB, the detector systems must operate eciently at much higher rates than the original Belle detector. A central element of the upgrade is the barrel particle identication system. Belle II has built and installed an imaging-Time-of-Propagation (iTOP) detector. The iTOP uses quartz optics as Cerenkov radiators. The photons are transported down the quart bars via total internal reection with a spherical mirror at the forwardend to reflect photons to the backward end where they are imaged onto an array of segmented Micro-Channel Plate Photo-Multiplier Tubes. The system is readout using gigsample per second waveform sampling Application-Specific Integrated Circuits that provide precise photon timing. The combined timing and spatial distribution of the photons for each event are used to determine particle species. This paper provides an overview of the iTOP system.

Fast, James E.↗

Real-Time Time-Dependent Electronic Structure Theory

Real-time electronic structure methods provide an unprecedented view of electron dynamics and ultrafast spectroscopy on the atto- and femtosecond time scale with vast potential to yield new insights into the electronic behavior of molecules and materials. Here, we discuss the fundamental theory underlying various real-time electronic structure methods as well as advantages and disadvantages of each. We give an overview of the numerical techniques that are widely used for real-time propagation of the quantum electron dynamics with an emphasis on Gaussian basis set methods. We also showcase many of the chemical applications and scientific advances made by using real-time electronic structure calculations and provide an outlook of possible new directions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Flow Configurations on Response Time and Data Quality in Real-Time, In-Line Fourier Transform Infrared (FTIR) Monitoring of Viscous Flows

The real-time, in-line monitoring of continuous flow concentrations is widely conducted via infrared (IR) spectrometry by using a flow cell connected to a reactive flow stream. For protective purposes, the IR sensor tip is typically offset from the flow. This offset can cause the formation of a stagnant boundary layer above the sensor, especially when dealing with high-viscosity fluids. As a result, the IR signal response time is often controlled by the slow diffusional exchange of fluid in the boundary layer, as confirmed via 2D computational fluid dynamics (CFD) simulations. We evaluated several flow configuration modifications in a typical IR flow cell in order to identify the changes to the flow dynamics that enable improved response times with minimal changes to the cell configuration: the use of (i) vertical flow, where the standard horizontal flow over the sensor is redirected to contact vertically with the sensor, (ii) a static mixer to create radial flow momentum above the IR sensor, and (iii) horizontal or vertical nozzles to direct the flow toward the IR sensor. The vertical flow configuration did not show any significant improvement over the standard horizontal flow configuration. However, the static mixer, horizontal nozzle, and vertical nozzle configurations all resulted in markedly improved response times and signal quality, albeit at the expense of a higher pressure drop across the flow cell. These results point toward straightforward, user-accessible modifications of in-line IR flow cells that result in significant improvements in signal stability and acquisition times.

42 ENGINEERING↗

Response-time improved hydrothermal-method-grown ZnO scintillator for soft x-ray free-electron laser timing-observation

For pump and probe experiments in x-ray free-electron laser (XFEL) facilities, accurate timing synchronization between short-wavelength femtosecond pulses from XFELs and short optical pulses from other light sources is required. For this purpose, the response time of a hydrothermal-method-grown ZnO is improved by over one order of magnitude via intentional iron ion doping. The fluorescence rise- and decay-time constants are measured to be less than 10 and 100 ps, respectively. Owing to its intense fluorescence even for single pulse XFEL excitation, the timing jitter of the soft x-ray pulse and timing electronics are evaluated to be less than 70 ps.

43 PARTICLE ACCELERATORS↗

Time-resolved single-photon detection module based on silicon photomultiplier: A novel building block for time-correlated measurement systems

We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm{sup 2} together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning time and energy resolution in time-resolved photoemission spectroscopy with nonlinear crystals

Time- and angle-resolved photoemission spectroscopy is a powerful probe of electronic band structures out of equilibrium. Tuning time and energy resolution to suit a particular scientific question has become an increasingly important experimental consideration. Many instruments use cascaded frequency doubling in nonlinear crystals to generate the required ultraviolet probe pulses. In this work, we demonstrate how calculations clarify the relationship between laser bandwidth and nonlinear crystal thickness contributing to experimental resolutions and place intrinsic limits on the achievable time-bandwidth product. Experimentally, we tune time and energy resolution by varying the thickness of nonlinear β-BaB 2 O 4 crystals for frequency upconversion, providing a flexible experiment design. We achieve time resolutions of 58–103 fs and corresponding energy resolutions of 55–27 meV. We propose a method to select crystal thickness based on desired experimental resolutions.

36 MATERIALS SCIENCE↗

Protein structural dynamics in solution unveiled via 100-ps time-resolved x-ray scattering

We have developed a time-resolved x-ray scattering diffractometer capable of probing structural dynamics of proteins in solution with 100-ps time resolution. This diffractometer, developed on the ID14B BioCARS (Consortium for Advanced Radiation Sources) beamline at the Advanced Photon Source, records x-ray scattering snapshots over a broad range of q spanning 0.02-2.5 {angstrom}{sup -1}, thereby providing simultaneous coverage of the small-angle x-ray scattering (SAXS) and wide-angle x-ray scattering (WAXS) regions. To demonstrate its capabilities, we have tracked structural changes in myoglobin as it undergoes a photolysis-induced transition from its carbon monoxy form (MbCO) to its deoxy form (Mb). Though the differences between the MbCO and Mb crystal structures are small (rmsd < 0.2 {angstrom}), time-resolved x-ray scattering differences recorded over 8 decades of time from 100 ps to 10 ms are rich in structure, illustrating the sensitivity of this technique. A strong, negative-going feature in the SAXS region appears promptly and corresponds to a sudden > 22 {angstrom}{sup 3} volume expansion of the protein. The ensuing conformational relaxation causes the protein to contract to a volume {approx}2 {angstrom}{sup 3} larger than MbCO within {approx}10 ns. On the timescale for CO escape from the primary docking site, another change in the SAXS/WAXS fingerprint appears, demonstrating sensitivity to the location of the dissociated CO. Global analysis of the SAXS/WAXS patterns recovered time-independent scattering fingerprints for four intermediate states of Mb. These SAXS/WAXS fingerprints provide stringent constraints for putative models of conformational states and structural transitions between them.

47 OTHER INSTRUMENTATION↗

TIME-DEPENDENT REBRIGHTENINGS IN CLASSICAL NOVA OUTBURSTS: A LATE-TIME EPISODIC FUEL BURNING?

A significant fraction of novae exhibit a series of rebrightenings on the decline branch of their light curves. We use visual observations to study this phase in several well-observed novae. We find that these rebrightenings are isolated flare-like events on otherwise smooth light curves and we show that in most novae in our sample the time intervals between consecutive flares gradually increase as a geometric series; rebrightenings are equally spaced in logarithmic time. We also find a correlation between the rate of increase in the time between rebrightenings with the speed class of the nova in the sense that slower novae tend to increase the time intervals faster. We attribute these rebrightenings to instabilities in the envelope hydrogen burning and we mention other cases of such timing patterns in astronomy and natural sciences in general.

79 ASTRONOMY AND ASTROPHYSICS↗

Sci-Fri AM: MRI and Diagnostic Imaging - 01: Estimating the Transverse Relaxation Time of Taurine Protons in Rat Brain at 9.4 T with Optimized PRESS Sequence Timings

Purpose: To investigate the response of taurine (Tau) protons as a function of PRESS echo times, TE{sub 1} and TE{sub 2}, to determine two TE combinations that can be employed to estimate the T{sub 2} (transverse relaxation) value of Tau at 9.4 T. The Tau protons are involved in J-coupling interactions; therefore, the two timing combinations should result in similar signal losses due to J-coupling. Methods: Experiments were performed with a 9.4 T animal MRI scanner. Numerical calculations of the response of Tau as a function of PRESS TE{sub 1} and TE{sub 2} were calculated and two TE combinations that yield a similar area for the 3.42 ppm Tau resonance were selected as optimal. The timings were verified on a 50 mM Tau/10 mM Cr (creatine) phantom. In-vivo experiments were performed on four rats. Spectra were acquired with the timings from a voxel placed in the rat brain and Tau peak areas were fit to monoexponentially decaying functions to obtain T{sub 2} values. Results: The PRESS TE combinations selected for Tau T{sub 2} determination are (TE{sub 1}, TE{sub 2}) = (17 ms, 10 ms) and (80 ms, 70 ms); the signal yield for the two timings differs by 5 % theoretically. The average Tau T{sub 2} for the four rats was found to be 106 ms with a standard deviation of 12 ms. Conclusions: We have demonstrated that acquiring PRESS spectra with (TE{sub 1}, TE{sub 2}) = (17 ms, 10 ms) and (TE{sub 1}, TE{sub 2}) = (80 ms, 70 ms) enables T{sub 2} corrected measures of Tau to be obtained at 9.4 T.

60 APPLIED LIFE SCIENCES↗

TIME-DEPENDENT ELECTRON ACCELERATION IN BLAZAR TRANSIENTS: X-RAY TIME LAGS AND SPECTRAL FORMATION

Electromagnetic radiation from blazar jets often displays strong variability, extending from radio to γ -ray frequencies. In a few cases, this variability has been characterized using Fourier time lags, such as those detected in the X-rays from Mrk 421 using Beppo SAX. The lack of a theoretical framework to interpret the data has motivated us to develop a new model for the formation of the X-ray spectrum and the time lags in blazar jets based on a transport equation including terms describing stochastic Fermi acceleration, synchrotron losses, shock acceleration, adiabatic expansion, and spatial diffusion. We derive the exact solution for the Fourier transform of the electron distribution and use it to compute the Fourier transform of the synchrotron radiation spectrum and the associated X-ray time lags. The same theoretical framework is also used to compute the peak flare X-ray spectrum, assuming that a steady-state electron distribution is achieved during the peak of the flare. The model parameters are constrained by comparing the theoretical predictions with the observational data for Mrk 421. The resulting integrated model yields, for the first time, a complete first-principles physical explanation for both the formation of the observed time lags and the shape of the peak flare X-ray spectrum. It also yields direct estimates of the strength of the shock and the stochastic magnetohydrodynamical wave acceleration components in the Mrk 421 jet.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast Determination of Distribution-Connected PV Impacts Using a Variable Time-Step Quasi-Static Time-Series Approach: Preprint

The increasing deployment of distribution-connected photovoltaic (DPV) systems requires utilities to complete complex interconnection studies. Relatively simple interconnection study methods worked well for low penetrations of photovoltaic systems, but more complicated quasi-static time-series (QSTS) analysis is required to make better interconnection decisions as DPV penetration levels increase. Tools and methods must be developed to support this. This paper presents a variable-time-step solver for QSTS analysis that significantly shortens the computational time and effort to complete a detailed analysis of the operation of a distribution circuit with many DPV systems. Specifically, it demonstrates that the proposed variable-time-step solver can reduce the required computational time by as much as 84% without introducing any important errors to metrics, such as the highest and lowest voltage occurring on the feeder, number of voltage regulator tap operations, and total amount of losses realized in the distribution circuit during a 1-yr period. Further improvement in computational speed is possible with the introduction of only modest errors in these metrics, such as a 91 percent reduction with less than 5 percent error when predicting voltage regulator operations.

14 SOLAR ENERGY↗

Fast-timing microchannel plate photodetectors: design, fabrication and characterization

We report a detailed design, fabrication, and characterization of 6 x 6 cm(2) fast timing photodetectors based on next-generation microchannel plates (MCPs). The whole assembly is made of low-cost borosilicate glass materials and hermetically sealed with a bialkali photocathode in a vacuum. The flexible photodetector design provides the potential of modifying individual components as well as the entire configuration to fit for different applications. A series of prototype MCP-photodetectors were fabricated following a step-by-step process including functionalization of glass capillary array through atomic layer deposition, MCP baking and scrubbing, photocathode deposition, and hermetic thermo-compression sealing. The prototype MCP-photodetectors exhibit electron gains well beyond 107 level with good relative uniformity. An excellent rise time of 439 ps, timing distribution root-mean-square at a single photoelectron mode of 105 ps, a timing resolution of 20 ps, and magnetic field tolerance up to 1.3 T were achieved for a photodetector with 10 mu m pore size MCPs, comparing to that of 536 ps, 205 ps, 63 ps, and 0.7 T for the one with 20 mu m pore size MCPs. Published under license by AIP Publishing.

fast timing↗

Accurate early‐time and late‐time modeling of countercurrent spontaneous imbibition

Abstract Spontaneous countercurrent imbibition into a finite porous medium is an important physical mechanism for many applications, included but not limited to irrigation, CO 2 storage, and oil recovery. Symmetry considerations that are often valid in fractured porous media allow us to study the process in a one‐dimensional domain. In 1‐D, for incompressible fluids and homogeneous rocks, the onset of imbibition can be captured by self‐similar solutions and the imbibed volume scales with . At later times, the imbibition rate decreases and the finite size of the medium has to be taken into account. This requires numerical solutions. Here we present a new approach to approximate the whole imbibition process semianalytically. The onset is captured by a semianalytical solution. We also provide an a priori estimate of the time until which the imbibed volume scales with . This time is significantly longer than the time it takes until the imbibition front reaches the model boundary. The remainder of the imbibition process is obtained from a self‐similarity solution. We test our approach against numerical solutions that employ parametrizations relevant for oil recovery and CO 2 sequestration. We show that this concept improves common first‐order approaches that heavily underestimate early‐time behavior and note that it can be readily included into dual‐porosity models.

March, Rafael↗

Just-in-Time Compilation and Link-Time Optimization for OpenMP Target Offloading

Following the mass adoption of external accelerators for high performance computing, the overall performance of many applications has become increasingly dependent on relatively small accelerated kernels. As static analysis is fundamentally limited by dynamic values and external definitions, standard ahead-of-time compilation is not always sufficient to achieve the best performance. Furthermore, many users looking to port an existing application to run on an external accelerator will not want to fundamentally restructure their programs. These and other problems can be addressed through both link-time optimization (LTO) and just-in-time (JIT) compilation, but until now had sparse and inconsistent support from the compiler. In this work, we present a new compilation method that enables device-side LTO as well as a transparent JIT compilation tool-chain for OpenMP target offloading. Our contributions include an entirely new device linking and embedding scheme to enable LTO as well as a novel JIT engine to efficiently optimize OpenMP offloading regions at run-time. We also introduce a persistent caching system to improve end-to-end runtime using the JIT engine and minimize kernel launching overheads. We measure the performance of our LTO and JIT implementation via several real-world scientific applications. With our optimizations we observe significant improvements through LTO on large applications as well as significant end-to-end execution time improvement using JIT.

Tian, Shilei↗

Finite time step and spatial grid effects in δf simulation of warm plasmas

This paper introduces a technique for analyzing time integration methods used with the particle weight equations in δf method particle-in-cell (PIC) schemes. The analysis applies to the simulation of warm, uniform, periodic or infinite plasmas in the linear regime and considers the collective behavior similar to the analysis performed by Langdon for full-f PIC schemes [1,2]. We perform both a time integration analysis and spatial grid analysis for a kinetic ion, adiabatic electron model of ion acoustic waves. An implicit time integration scheme is studied in detail for δf simulations using our weight equation analysis and for full-f simulations using the method of Langdon. It is found that the δf method exhibits a CFL-like stability condition for low temperature ions, which is independent of the parameter characterizing the implicitness of the scheme. The accuracy of the real frequency and damping rate due to the discrete time and spatial schemes is also derived using a perturbative method. The theoretical analysis of numerical error presented here may be useful for the verification of simulations and for providing intuition for the design of new implicit time integration schemes for the δf method, as well as understanding differences between δf and full-f approaches to plasma simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A space-time adaptive finite element method with exponential time integrator for the phase field model of pitting corrosion

In this paper we propose a space-time adaptive finite element method for the phase field model of pitting corrosion, which is a parabolic partial differential equation system consisting of a phase variable and a concentration variable. A major challenge in solving this phase field model is that the problem is very stiff, which makes the time step size extremely small for standard temporal discretizations. Another difficulty is that a high spatial resolution is required to capture the steep gradients within the diffused interface, which results in very large number of degrees of freedom for uniform meshes. To overcome the stiffness of this model, we combine the Rosenbrock–Euler exponential integrator with Crank–Nicolson scheme for the temporal discretization. Moreover, by exploiting the fact that the speed of the corroding interface decreases with time, we derive an adaptive time stepping formula. For the spatial approximation, we propose a simple and efficient strategy to generate adaptive meshes that reduces the computational cost significantly. Thus, the proposed method utilizes local adaptivity and mesh refinement for efficient simulation of the corrosive dissolution over long times in heterogeneous media with complex microstructures. We also present an extensive set of numerical experiments in both two and three dimensional spaces to demonstrate efficiency and robustness of the proposed method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Practical Approach to Wave Function Propagation, Hopping Probabilities, and Time Steps in Surface Hopping Calculations

We compare several established approaches for propagating wave functions and calculating hopping probabilities within the fewest switches surface hopping (FSSH) algorithm for difficult cases with many electronic states and many trivial crossings. If only a single time step (Δt c ) is employed, we find that no published approach can accurately capture the dynamics correctly unless Δt c → 0 (which is not computationally feasible). If multiple time steps are employed, for a fixed classical time step (Δt c ), a robust scheme can be found for dynamically choosing quantum time steps (δt q1 and δt q2 ) and calculating hopping probabilities so that one can systematically reduce all errors and achieve maximally efficient accuracy; scattering calculations confirm that one can choose a fairly large classical time step. Furthermore, the robust scheme presented here uses both the “local diabatic” and adiabatic interpolation and thus borrows elements from both the Granucci/Persico and Meek/Levine algorithms. Our findings should be broadly applicable in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Time-Dependent Nuclear–Electronic Orbital Approach: Dynamics beyond the Born–Oppenheimer Approximation

The quantum mechanical treatment of both electrons and nuclei is crucial in nona- diabatic dynamical processes such as proton-coupled electron transfer. The nuclear electronic orbital (NEO) method provides an elegant framework for including nuclear quantum effects beyond the Born-Oppenheimer approximation. To enable the study of nonequilibrium properties, we derive and implement a real-time NEO (RT-NEO) approach based on time-dependent Hatree-Fock or density functional theory, in which both the electronic and nuclear degrees of freedom are propagated in a time-dependent variational framework. Nuclear and electronic spectral features can be resolved from the time-dependent dipole moment computed using the RT-NEO method. The test cases demonstrate the dynamical interplay between the quantum nuclei and the electrons through vibronic coupling. Moreover, vibrational excitation in the RT-NEO approach is demonstrated by applying a resonant driving eld, and electronic excitation is demonstrated by simulating excited state intramolecular proton transfer. This work shows that the RT-NEO approach is a promising tool to study nonadiabatic quantum dynamical processes within a time-dependent variational description for the coupled electronic and nuclear degrees of freedom.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗