At least 289 records · Page 16

Component variations and their effects on bipolar nickel-hydrogen cell performance

A 50 cell bipolar nickel-hydrogen battery was assembled to demonstrate the feasibility of constructing a high voltage stack of cells. Various component combinations were tested in this battery. The battery had approximately 1 ampere-hour of capacity and was constructed from components with an active area of 2 x 2 inches. The components were parametrically varied to give a comparison of nickel electrodes, hydrogen electrodes, separators, fill procedures and electrolyte reservoir plate thicknesses. Groups of five cells were constructed using the same components; ten combinations were tested in all. The battery was thoroughly characterized at various change and discharge rates as well as with various pulse patterns and rates. Over a period of 1400 40-percent DOD LEO cycles some of the groups began to exhibit performance differences. In general, only separator variations had a significant effect on cell performance. It also appears that shunt currents may have been operating within the stack, resulting in electrolyte transfer from one cell to another, thus contributing to cell performance variations.

Manzo, Michelle A.↗

Impedances of Li/SO2 cells retrieved from the Long Duration Exposure Facility (LDEF satellite) and comparison with cells stored terrestrially

Impedances were measured on several Li/SO2 cells retrieved from the Long Duration Exposure Facility (LDEF) satellite. These cells were used to power instruments and recorders and had all been partially or fully discharged. Impedances were also measured on several cells that were stored in cold storage since manufacture. Unfortunately, none of the cells stored terrestrially had undergone any discharge, whereas all of the cells on the satellite were at least partially discharged early in the mission and then remained on orbit for about 5 years further. It has been observed by others that storage of an Li/SO2 cell after partial discharge, increases the resistance and thickness of the passive film on the Li electrode, as indicated by an increase in the time for recovery of voltage when a load is applied (voltage lag), or in some cases by an inability of a cell to sustain a normal current after such storage. Since the cells stored terrestrially were not discharged in the same manner as the LDEF cells, a direct comparison cannot be made. Thus, the effects of the space environment cannot be separated from the effects of storage after partial discharge. It is believed that the increases in impedance in the LDEF cells are largely due to the storage upon partial discharge rather than the effects of the space environment.

Reid, Margaret A.↗

Compact Packaging of Photonic Millimeter-Wave Receiver

A carrier structure made from a single silicon substrate is the basis of a compact, lightweight, relatively inexpensive package that holds the main optical/electronic coupling components of a photonic millimeter-wave receiver based on a lithium niobate resonator disk. The design of the package is simple and provides for precise relative placement of optical components, eliminating the need for complex, bulky positioning mechanisms like those commonly used to align optical components to optimize focus and coupling. Although a prototype of the package was fabricated as a discrete unit, the design is amenable to integration of the package into a larger photonic and/or electronic receiver system. The components (see figure) include a lithium niobate optical resonator disk of 5-mm diameter and .200- m thickness, positioned adjacent to a millimeter- wave resonator electrode. Other components include input and output coupling prisms and input and output optical fibers tipped with ball lenses for focusing and collimation, respectively. Laser light is introduced via the input optical fiber and focused into the input coupling prism. The input coupling prism is positioned near (but not in contact with) the resonator disk so that by means of evanescent-wave coupling, the input laser light in the prism gives rise to laser light propagating circumferentially in guided modes in the resonator disk. Similarly, a portion of the circumferentially propagating optical power is extracted from the disk by evanescent-wave coupling from the disk to the output coupling prism, from whence the light passes through the collimating ball lens into the output optical fiber. The lens-tipped optical fibers must be positioned at a specified focal distance from the prisms. The optical fibers and the prisms must be correctly positioned relative to the resonator disk and must be oriented to obtain the angle of incidence (55 in the prototype) required for evanescent-wave coupling of light into and out of the desired guided modes in the resonator disk. To satisfy all these requirements, precise alignment features are formed in the silicon substrate by use of a conventional wet-etching process. These features include a 5-mm-diameter, 50- m-deep cavity that holds the disk; two trapezoidal-cross-section recesses for the prisms; and two grooves that hold the optical fibers at the correct positions and angles relative to the prisms and disk. The fiber grooves contain abrupt tapers, near the prisms, that serve as hard stops for positioning the lenses at the focal distance from the prisms. There are also two grooves for prismadjusting rods. The design provides a little slack in the prism recesses for adjusting the positions of the prisms by means of these rods to optimize the optical coupling.

Nguyen, Hung↗

Enhancement of Ni–(Y 2 O 3 ) 0.08 (ZrO 2 ) 0.92 fuel electrode performance by infiltration of Ce 0.8 Gd 0.2 O 2–δ nanoparticles

This paper addresses the use of Ce 0.8 Gd 0.2 O 2–δ (GDC) infiltration into the Ni–(Y 2 O 3 ) 0.08 (ZrO 2 ) 0.92 (YSZ) fuel electrode of solid oxide cells (SOCs) for improving their electrochemical performance in fuel cell and electrolysis operation. Although doped ceria infiltration into Ni–YSZ has recently been shown to improve the electrode performance and stability, the mechanisms defining how GDC impacts electrochemical characteristics are not fully delineated. Furthermore, the electrochemical characteristics have not yet been determined over the full range of conditions normally encountered in fuel cell and electrolysis operation. Here we present a study of both symmetric and full cells aimed at understanding the electrochemical mechanisms of GDC-modified Ni–YSZ over a wide range of fuel compositions and temperatures. Single-step GDC infiltration at an appropriate loading substantially reduced the polarization resistance of Ni–YSZ electrodes in electrolyte-supported cells, as measured using electrochemical impedance spectroscopy (EIS) at various temperatures (600–800 °C) in a range of H 2 O–H 2 mixtures (3–90 vol% H 2 O). Fuel-electrode-supported cells had significant concentration polarization due to the thick Ni–YSZ supports. Here, a distribution of relaxation times approach is used to develop a physically-based electrochemical model; the results show that GDC reduces the reaction resistance associated with three-phase boundaries, but also appears to improve oxygen transport in the electrode. Increasing the H 2 O fraction in the H 2 –H 2 O fuel mixture reduced both the three-phase boundary resistance and the gas diffusion resistance for Ni–YSZ; with GDC infiltration, the electrode resistance showed less variation with fuel composition. GDC infiltration improved the performance of fuel-electrode-supported full cells, which yielded a maximum power density of 2.28 W cm –2 in fuel cell mode and an electrolysis current density at 1.3 V of 2.22 A cm –2 , both at 800°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Low-Cost Iron-Based Current Collector for Alkaline Battery Electrodes

The use of three-dimensional porous nickel foam as the current collector of the nickel hydroxide electrode adds significantly to the cost of the nickel-based alkaline rechargeable batteries. Although iron is considerably less expensive than nickel, iron corrodes at the operating potential of the nickel hydroxide electrode. We have found that a 70–100 nm thick thermal coating of cobalt ferrite spinel protects the iron from corrosion. Such a coated iron substrate was found to be stable against corrosion even when polarized anodically at 10 mA cm -2 in 30% potassium hydroxide electrolyte for 1000 h. While the thermal coating of cobalt ferrite protected iron against corrosion, incorporation of lithium ions into the coating was found to enhance the electrical conductivity of the coating. XPS and EXAFS studies confirmed that the enhanced conductivity resulted from an increase in the population of Co 3+ in the ferrite spinel lattice. An inexpensive iron (steel) substrate protected by such a coating when used as a nickel hydroxide battery electrode exhibited a specific capacity of 0.25 Ah g -1 at C/5 discharge rate, comparable to a nickel hydroxide electrode based on a relatively expensive nickel foam substrate. The steel-based electrode also exhibited no noticeable degradation over 150 cycles at C/2 rate. This demonstration of a robust and economical steel substrate presents a unique opportunity for reducing the cost of the nickel hydroxide battery electrode in alkaline batteries

25 ENERGY STORAGE↗

Implementation of a Thick-Film Composite Li-Ion Microcathode Using Carbon Nanotubes as the Conductive Filler

This paper describes the development of a thick-film microcathode for use in Li-ion microbatteries in order to provide increased power and energy per area. These cathodes take advantage of a composite porous electrode structure, utilizing carbon nanotubes (CNT) as the conductive filler. The use of carbon nanotubes was found to significantly reduce the measured resistance of the electrodes, increase active material accessibility, and improve electrode performance. In particular, the cycling and power performance of the thick-film cathodes was significantly improved, and the need for compression was eliminated. Cathode thickness and CNT content were optimized to maximize capacity and power performance. Power capability of >50 mW/sq cm (17 mA/sq cm) with discharge capacity of >0.17 mAh/sq cm was demonstrated. The feasibility of fabricating thick-film microcathodes capable of providing the power and capacity needed for use in autonomous microsensor systems was also demonstrated.

Lin, Qian↗

Ultrathin conformal OCVD PEDOT coatings on porous electrodes and applications thereof

The present disclosure relates to electrodes comprising a polymer film and a substrate, wherein the polymer film has a thickness of about 5 nm to about 600 nm. The present disclosure also relates to electrochemical cells and batteries comprising the electrodes disclosed herein. The present disclosure also relates to methods of making the electrodes disclosed herein.

Gleason, Karen K.↗

Reaction heterogeneity in practical high-energy lithium–sulfur pouch cells

The lithium–sulfur (Li–S) battery is a promising next-generation energy storage technology because of its high theoretical energy and low cost. Extensive research efforts have been made on new materials and advanced characterization techniques for mechanistic studies. However, it is uncertain how discoveries made on the material level apply to realistic batteries due to limited analysis and characterization of real high-energy cells, such as pouch cells. Evaluation of pouch cells (>1 A h) (instead of coin cells) that are scalable to practical cells provides a critical understanding of current limitations which enables the proposal of strategies and solutions for further performance improvement. Herein, we design and fabricate pouch cells over 300 W h kg -1 , compare the cell parameters required for high-energy pouch cells, and investigate the reaction processes and their correlation to cell cycling behavior and failure mechanisms. Spatially resolved characterization techniques and fluid-flow simulation reveal the impacts of the liquid electrolyte diffusion within the pouch cells. We found that catastrophic failure of high-energy Li–S pouch cells results from uneven sulfur/polysulfide reactions and electrolyte depletion for the first tens of cycles, rather than sulfur dissolution as commonly reported in the literature. The uneven reaction stems from limited electrolyte diffusion through the porous channels into the central part of thick cathodes during cycling, which is amplified both across the sulfur electrodes and within the same electrode plane. A combination of strategies is suggested to increase sulfur utilization, improve nanoarchitectures for electrolyte diffusion and reduce consumption of the electrolytes and additives.

25 ENERGY STORAGE↗

Low-Pressure, Field-Ionizing Mass Spectrometer

A small mass spectrometer utilizing a miniature field ionization source is now undergoing development. It is designed for use in a variety of applications in which there are requirements for a lightweight, low-power-consumption instrument that can analyze the masses of a wide variety of molecules and ions. The device can operate without need for a high-vacuum, carrier-gas feed radioactive ionizing source, or thermal ionizer. This mass spectrometer can operate either in the natural vacuum of outer space or on Earth at any ambient pressure below 50 torr (below about 6.7 kPa) - a partial vacuum that can easily be reached by use of a small sampling pump. This mass spectrometer also has a large dynamic range - from singly charged small gas ions to deoxyribonucleic acid (DNA) fragments larger than 104 atomic mass units - with sensitivity adequate for detecting some molecules and ions at relative abundances of less than one part per billion. This instrument (see figure) includes a field ionizer integrated with a rotating-field mass spectrometer (RFMS). The field ionizer effects ionization of a type characterized as "soft" in the art because it does not fragment molecules or initiate avalanche arcing. What makes the "soft" ionization mode possible is that the distance between the ionizing electrodes is less than mean free path for ions at the maximum anticipated operating pressure, so that the ionizer always operates on the non-breakdown side of the applicable Paschen curve (a standard plot of breakdown potential on the ordinate and pressure electrode separation on the abscissa). The field ionizer in this instrument is fabricated by micromachining a submicron-thick membrane out of an electrically nonconductive substrate, coating the membrane on both sides to form electrodes, then micromachining small holes through the electrodes and membrane. Because of the submicron electrode separation, even a potential of only 1 V applied between the electrodes gives rise to an electric field with a strength of in excess of a megavolt per meter strong enough to ionize any gas molecules passing through the holes. An accelerator grid and an electrostatic deflector focus the ions from the field ionizer into the rotating-field cell of the RFMS. The potentials applied to the electrodes of the cell to generate the rotating electric field typically range from 1 to 13 V. The ions travel in well-defined helices within this cell, after which they are collected in a Faraday cup. The mass of most of the molecules reaching the Faraday cup decreases with increasing frequency of rotation of the electric field in the cell. Therefore, the frequency of rotation of the electric field is made to vary in order to scan through a desired range of ion masses: For example, lightweight gas molecules are scanned at frequencies in the megahertz range, while DNA and other large organic molecules are scanned at kilohertz frequencies.

Hartley, Frank↗

Electrode chemistry impact on retention performance of ferroelectric hafnium zirconium oxide (Hf 0.5 Zr 0.5 O 2−x ) capacitors

Polarization retention of 10 nm thick ferroelectric hafnium zirconium oxide (Hf 0.5 Zr 0.5 O 2−x , HZO) capacitors with W and TaN electrodes is investigated over temperatures ranging from 85 to 150 °C. Same state and opposite state polarization margins for devices with W electrodes show minimal retention loss after 10 5 at 150 °C. The devices capped with TaN electrodes show excellent same state retention, but the opposite state polarization margin in the TaN-electrode devices displays 40% retention loss at 150 °C after 10 5 s. The TaN-capped devices exhibit a more pronounced imprint, which is attributed to an increased oxygen vacancy content (compared to W-capped devices). The increased oxygen vacancy content in the TaN-capped devices is supported by photoluminescence and leakage current measurements. In addition, TaN-capped devices have chemically diffuse electrode–HZO interfaces; more abrupt interfaces are present in the W-capped devices. The presence of interfacial phases in the TaN-capped devices may lead to larger depolarization fields due to reduced charge screening. The results from this study provide further evidence that for HZO ferroelectric devices the electrode can significantly impact polarization retention behavior due to differences in oxygen vacancy concentration and formation of non-ferroelectric interfacial layers.

36 MATERIALS SCIENCE↗

Progress in Development of Improved Ion-Channel Biosensors

Further improvements have recently been made in the development of the devices described in Improved Ion-Channel Biosensors (NPO-30710), NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 30. As discussed in more detail in that article, these sensors offer advantages of greater stability, greater lifetime, and individual electrical addressability, relative to prior ion-channel biosensors. In order to give meaning to a brief description of the recent improvements, it is necessary to recapitulate a substantial portion of the text of the cited previous article. The figure depicts one sensor that incorporates the recent improvements, and can be helpful in understanding the recapitulated text, which follows: These sensors are microfabricated from silicon and other materials compatible with silicon. Typically, the sensors are fabricated in arrays in silicon wafers on glass plates. Each sensor in the array can be individually electrically addressed, without interference with its neighbors. Each sensor includes a well covered by a thin layer of silicon nitride, in which is made a pinhole for the formation of a lipid bilayer membrane. In one stage of fabrication, the lower half of the well is filled with agarose, which is allowed to harden. Then the upper half of the well is filled with a liquid electrolyte (which thereafter remains liquid) and a lipid bilayer is painted over the pinhole. The liquid contains a protein that forms an ion channel on top of the hardened agarose. The combination of enclosure in the well and support by the hardened agarose provides the stability needed to keep the membrane functional for times as long as days or even weeks. An electrode above the well, another electrode below the well, and all the materials between the electrodes together constitute a capacitor. What is measured is the capacitive transient current in response to an applied voltage pulse. One notable feature of this sensor, in comparison with prior such sensors, is a relatively thick dielectric layer between the top of the well and the top electrode. This layer greatly reduces the capacitance of an aperture across which the ion channels are formed, thereby increasing the signal-to-noise ratio. The use of a relatively large aperture with agarose support makes it possible to form many ion channels instead of only one, thereby further increasing the signal-to-noise ratio and effectively increasing the size of the available ionic reservoir. The relatively large reservoir makes it possible to measure AC rather than DC. This concludes the recapitulation from the cited previous article.

Nadeau, Jay L.↗

Impact of surface hydrophilicity on the ordering and transport properties of bicontinuous microemulsions

Microemulsions (MEs) have many industrial applications, where recent developments have shown that MEs can be utilized for electrochemical applications, including potentially in redox flow batteries. However, understanding the structure and dynamics of these systems, including at a surface, is needed to direct and rationally control their electrochemical behavior. While bulk solution measurements have provided insight into their structure, their assembly at an interface also impacts the electron (to the electrode) and ion (across the surfactant) charge transfer processes in the system. To address this shortcoming, neutron reflectivity experiments and molecular simulations have been completed that document the near surface structure of a series of deuterated water (D 2 O)/polysorbate-20/toluene MEs on hydrophilic and amphiphilic surfaces. These results show that the microemulsions form complex layered structures near a hard electrode surface, where most layers are not purely one component. Decreasing the D 2 O concentration in the ME increases the number of and purity of the layers established on the solid surface. These lamellar-type layers transition from the surface to the bulk microemulsion as a series of mixed layers (i.e., containing oil, water, and surfactant) that are consistent with perforated lamellae. Additionally, these mixed lamellae appear to become more perforated with oil and water pathways on an amphiphilic surface. Furthermore, the purity and thickness of these layers will influence the accessibility of an electrode by redox active species, as well as ion transport required to satisfy the electroneutrality condition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Solution-Processable High-Modulus Crystalline Artificial Solid Electrolyte Interphase for Practical Lithium Metal Batteries

The solid electrolyte interphase (SEI) has been identified as a key challenge for Li metal anodes. The brittle and inhomogeneous native SEI generated by parasitic reactions between Li and liquid electrolytes can devastate battery performance; therefore, artificial SEIs (ASEIs) have been proposed as an effective strategy to replace native SEIs. Herein, as a collaboration between academia and industrial R&D teams, a multifunctional (crystalline, high modulus, and robust, Li + ion conductive, electrolyte-blocking, and solution processable) ASEI material, LiAl-FBD (where “FBD” refers to 2,2,3,3-tetra-fluoro-1,4-butanediol), for improving Li metal battery performance is designed and synthesized. The LiAl-FBD crystal structure consists of Al 3+ ions bridged by FBD 2– ligands to form anion clusters while Li + ions are loosely bound at the periphery, enabling an Li + ion conductivity of 9.4 × 10 –6 S cm –1 . Further, the fluorinated, short ligands endow LiAl-FBD with electrolyte phobicity and high modulus. The ASEI is found to prevent side reactions and extend the cycle life of Li metal electrodes. Specifically, pairing LiAl-FBD coated 50 μm thick Li with industrial 3.5 mAh cm –2 NMC811 cathode and 2.8 μL mAh –1 lean elec-trolyte, the Li metal full cells show superior cycle life compared to bare ones, achieving 250 cycles at 1 mA cm –2 .

25 ENERGY STORAGE↗

Concentration dependent properties and plastic deformation facilitate instability of the solid-electrolyte interphase in Li-ion batteries

Lithium-ion batteries (LIBs) often suffer from capacity fading and poor cyclic performance due to mechanical degradation of the solid-electrolyte interphase (SEI). Here we perform numerical simulations and theoretical analysis to elucidate the role of plasticity in wrinkling and ratcheting behaviors of an SEI/electrode system. A coupled diffusion and finite deformation framework is formulated and numerically implemented as a user-element subroutine (UEL) to describe transient lithium diffusion and accompanying elastic–viscoplastic deformation of the electrode. It is found that concentration dependent properties and plastic deformation facilitate wrinkling in such a system. A wrinkled morphology may further lead to ratcheting and related failure under cycling. A phase diagram of four types of cyclic behaviorsis identified in terms of the charging rate and time. Our analysis suggests several potential strategies to avoid wrinkling and ratcheting instabilities, such as charging/discharging the electrode at a sufficiently slow rate, and/or introducing a thick artificial SEI with a pre-tension.

25 ENERGY STORAGE↗

Miniature DC electromagnetic pumps of molten lead and sodium to support development of Gen-IV nuclear reactors

This work developed designs of submerged, dual-regions, miniature DC-EM pumps for circulating molten lead and liquid sodium at ≤500 °C without active cooling for use in ex-pile and in-pile test loops to support of materials and fuel developments for Gen-IV sodium and molten lead fast nuclear reactor. These pumps with two pumping regions are 57 mm, 66.8 mm, 95.4 mm, and 133.5 mm in diameter and have two Alnico 5 permanent magnets with Hiperco-50 pole pieces for focusing the magnetic field lines in the flow duct. The Equivalent Circuit Model (ECM) linked to the Finite Element Method Magnetics (FEMM) software in MATLAB platform calculated the pumps characteristics for a wide range of parameters. Also determined are the pumps dimensions for the highest cumulative pumping power and peak efficiency. These dimensions are the height, width, and length of the flow duct, the thickness of the Alnico magnets, the length of current electrodes, and the separation distance between the two pumping regions. For molten lead, the pumping power increases from 368 W to 728 W, and the peak efficiency from 14.7% to 31.6% with increased pump diameter from 57 mm to 133.5 mm. In conclusion, for liquid sodium, both the pumping power and peak efficiency are higher, increasing from 392 W to 767 W and from 44.3 to 51.2%, respectively, with increased pump diameter from 57 mm to 133.5 mm.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Townsend to glow discharge transition for a nanosecond pulse plasma in helium: space charge formation and resulting electric field dynamics

Stark polarization spectroscopy is used to investigate the temporal evolution of the electric field distribution in the cathode region of a nanosecond pulsed discharge in helium at 120 Torr. The measurements are performed on the He I transition at 492.19 nm, during the early stages of the discharge formation. The experimental results are compared with the predictions of a 1D fluid model. Time-resolved ICCD images show that the discharge develops as a diffuse, cathode-directed ionization wave with a Townsend-like feature before transitioning into a glow-like structure. Near anode instabilities characterized by filament formation were observed near the high voltage electrode. Within 30 ns, a reduction of the sheath thickness to about 250 μm is observed, coinciding with a gradual increase of the discharge current and proportional increase in electric field at the cathode. Additionally, the cathode electric field corresponding to this sheath with a thickness of 250 μm is about 40 kV cm -1 . A subsequent steep increase of the discharge current leads to a further reduction of the sheath width. The electric field evolution as obtained by the fluid model is in excellent agreement with the measurements and shows that an enhanced ionization near the cathode is causing the space charge formation responsible for the increase in electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Continuous-flow electrophoretic separator for biologicals

In the near absence of gravity, a continuous-flow type of electrophoretic separator can be operated with a much thicker separation chamber than is possible under 1 g conditions. This should permit either better resolution or shorter separation time per unit of sample. An apparatus to perform experiments on sounding rockets is under development and will be described. The electrophoresis cell is 5 mm thick by 5 cm wide with 10 cm long electrodes. It is supplied with buffer, sample, and coolant at about 4 C through the use of a passive refrigerant system. UV sample detection and provision for recovery and cold storage of up to 50 sample fractions are now being added to the basic unit. A wide range of operating conditions are electronically programmable into the unit, even up to a short time before flight, and a further range of some parameters can be achieved by exchanging power supplies and by changing gears in the motor drive units of the pump. The preliminary results of some separation studies on various biological products using a commercially available electrophoretic separator are also presented.

Mccreight, L. R.↗