Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal runaway”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Rated Temperature Of Silver/Zinc Batteries Is Increased

Report shows silver-zinc batteries of specific commercial type (28 V, 20 A*h, Eagle-Picher Battery MAR 4546-5) operated safely at higher temperature than previously thought possible. Batteries operated to 239 degrees F (115 degrees C) without going into sustained thermal runaway. Operated 49 degrees F (27 degrees C) above previous maximum.

Hill, Derek P.↗

Control of internal and external short circuits in lithium batteries using a composite thermal switch

A composite material has been developed, consisting of a blend of metal and fluorocarbon particles, which behaves as an electronic conductor at room temperature and which abruptly becomes an insulator at a predetermined temperature. This switching behavior results from the difference in thermal expansion coefficients between the conductive and non-conductive portions of the composite. This material was applied as a thin film between the carbon cathode in Li/SOCl2 cells, and the metallic cathode current collector. Using test articles incorporating this feature it was shown that lithium cells externally heated or internally heated during a short circuit lost rate capability and the ability to overheat well below the melting point of lithium (180 C). Thus, during an internal or external cell short circuit, the potential for thermal runaway involving reactions of molten lithium is avoided.

Mcdonald, Robert C.↗

Steady state temperature profile in a sphere heated by microwaves

A new theory has been developed to calculate the microwave absorption and resultant temperature profile within a sphere positioned in a single mode rectangular cavity. This theory is an extension of a total absorption model based on Mie scattering results. Temperature profiles have been computed for alumina spheres at the center of a rectangular cavity excited in the TM354 mode. Parametric studies reveal significant structure in those profiles under special conditions that are associated with electromagnetic resonances inside the spheres. Anomalous behavior similar to thermal runaway occurs at moderate temperatures when there is enhanced absorption associated with resonant conditions in the sphere.

Barmatz, M.↗

Planet-B: Technical notes and drawings

The design of the transformer designated as T101 (061-0351) in the Filament/Bias module (061-0119) in the Planet-B NMS instrument was verified because of the differences from the GCMS and INMS instrument designs. A breadboard of a representation of the Hybrid 2301065, Bias Drive A driving a 2N3700 NPN transistor, with dual 75V secondaries, with loads, was used to test the circuit. The initial transformer design that was wound with bifilar secondaries was too unstable to test. The second 1408 transformer with a split bobbin and the feedback winding below the primary was also found to be unstable. (It was nearly impossible to keep the circuit from squeeging). The third transformer tested has the feedback on the outside of the resonant winding. The primary goal of the design was to have as tight a magnetic coupling as possible to the resonant winding, and as loose a coupling as possible to the primary. Further, the circuit AC ground is connected to the winding at the feedback end of the secondary winding. This transformer proved to be very stable - it is virtually impossible to make this design squeg. An emitter resistor (Rl29A) was added to this circuit, as referenced to the GCMS design, to protect Q102 from thermal runaway in the event of a turn on with a non- resonate circuit or load short. This was verified to protect Q102 for at least 30 seconds in the event of a short. Approximately 1% of the 4lmW input power is lost in this protection resistor under normal operation. The circuit was verified to operate normally when a radiated Q102 (2N3700), (low Beta) transistor was substituted for the normal 2N3700. It should be noted that the monitored drive voltage went to approximately 2.7V with this low gain transistor.

Carignan, George R.↗

Energetic Consequences of the DC-Electric Field Model

We analyze a solar flare observed simultaneously in soft and hard X-rays by instruments onboard Yohkoh and the Compton Gamma Ray Observatory. Assuming a simple one-dimensional coronal loop that is heated by field-aligned currents, we solve the energy balance equation to derive the DC-electric field strength necessary to explain the observed soft X-ray emission by current-dissipation. We use the derived DC-electric field to predict the number flux of electrons accelerated by thermal runaway and compare this prediction with the number flux of nonthermal thick-target electrons implied by impulsive phase hard X-ray observations. We find that runaway acceleration can account for the large flux (approx. greater than 10(exp 36 1/s) of nonthermal electrons provided the loop filling factor is approx. less than 10(exp -3) such that heating and acceleration occur in filamented structures within the loop.

Zarro, Dominic M.↗

Analyses of Transistor Punchthrough Failures

The failure of two transistors in the Altitude Switch Assembly for the Solid Rocket Booster followed by two additional failures a year later presented a challenge to failure analysts. These devices had successfully worked for many years on numerous missions. There was no history of failures with this type of device. Extensive checks of the test procedures gave no indication for a source of the cause. The devices were manufactured more than twenty years ago and failure information on this lot date code was not readily available. External visual exam, radiography, PEID, and leak testing were performed with nominal results Electrical testing indicated nearly identical base-emitter and base-collector characteristics (both forward and reverse) with a low resistance short emitter to collector. These characteristics are indicative of a classic failure mechanism called punchthrough. In failure analysis punchthrough refers to an condition where a relatively low voltage pulse causes the device to conduct very hard producing localized areas of thermal runaway or "hot spots". At one or more of these hot spots, the excessive currents melt the silicon. Heavily doped emitter material diffuses through the base region to the collector forming a diffusion pipe shorting the emitter to base to collector. Upon cooling, an alloy junction forms between the pipe and the base region. Generally, the hot spot (punch-through site) is under the bond and no surface artifact is visible. The devices were delidded and the internal structures were examined microscopically. The gold emitter lead was melted on one device, but others had anomalies in the metallization around the in-tact emitter bonds. The SEM examination confirmed some anomalies to be cosmetic defects while other anomalies were artifacts of the punchthrough site. Subsequent to these analyses, the contractor determined that some irregular testing procedures occurred at the time of the failures heretofore unreported. These testing irregularities involved the use of a breakout box and were the likely cause of the failures. There was no evidence to suggest a generic failure mechanism was responsible for the failure of these transistors.

Nicolas, David P.↗

Ignition Delay Associated with a Strained Strip

Ignition processes associated with two adjacent fuel-oxidizer interferences bounding a strained fuel strip are explored here using single-step activation energy asymptotics. Calculations are made for constant as well as temporally decaying strain fields. There possible models of ignition are determined: one in which the two interfaces ignite independently as diffusion flames; one in which the two interfaces ignite dependently and in which ignition occurs to form a single , premixed flame at very high strain rates before ignition is completely prevented. In contrast to a single, isolated interface in which ignition can be prevented by overmatching heat production with heat convection due to strain, ignition of a strained fuel strip can also be prevented if the finite extend of fuel is diluted by oxidizer more quickly than heat production can cause a positive feedback thermal runaway. These behaviors are dependent on the relative sizes of timescales associated with species and heat diffusion, with convection due to strain, and with the chemical reaction. The result here indicate that adjacent, strained species interfaces may ignite quite differently in nature from ignition of a single, strained intrface and that their interdependence should be considered as the interfaces are brought closer together in complex strain fields. Critical strain rates leading to complete ignition delay are found to be considerably smaller for the fuel strip than those for single interfaces as the fuel strip is made thin in comparison to diffusion and chemical length scales.

Gerk, T. J.↗

Engineering and Abuse Testing of Panasonic Lithium-Ion Battery and Cells

This viewgraph presentation reviews the performance testing of Lithium Ion batteries and cells under different conditions of charge and discharge. The tests show that the 0.5 C rate of charge and discharge might be the ideal condition for long term cycling. It reviews the issues of overcharge and overdischarge of the cells. The cells and the battery have adequate protection under both conditions to prevent any catastrophic occurrences. Temperatures above 150 C are required to vent the cells or cause a thermal runaway, Since this situation is non-credible in the cabin of the Space Shuffle or ISS this should not pose a problem. The presentation includes graphs and charts showing the charge and discharge capacities of the battery and also the current and voltage profiles. A view of a circuit board which contains the controlling mechanism for the battery is also shown.

Jeevarajan, Judith A.↗

Performance and Safety Testing of Cylindrical Moli Lithium-Ion Cells

The Moli lithium-ion cells were tested under normal and abuse conditions. The cells exhibit only 50% of their original capacity at about -10 C. The optimum charge/discharge rate with the least percentage loss in capacity is C/2 charge and C/4 discharge. The cells did not explode or go into a thermal runaway during venting at very high temperatures. They exhibited good tolerance under the vibration conditions tested and could potentially be used in the build up of large batteries that have high current pulse (up to 3C) applications.

Jeevarajan, Judith A.↗

Experimental Study of Serpentinization Reactions

Current carbonaceous chondrite parent-body thermal models [1-3] produce scenarios that are inconsistent with constraints on aqueous alteration conditions based on meteorite mineralogical evidence, such as phase stability relationships within the meteorite matrix minerals [4] and isotope equilibration arguments [5, 6]. This discrepancy arises principally because of the thermal runaway effect produced by silicate hydration reactions (here loosely called serpentinization, as the principal products are serpentine minerals), which are so exothermic as to produce more than enough heat to melt more ice and provide a self-sustaining chain reaction. One possible way to dissipate the heat of reaction is to use a very small parent body [e.g., 2] or possibly a rubble pile model. Another possibility is to release this heat more slowly, which depends on the alteration reaction path and kinetics.

Cohen, B. A.↗

Droplet-surface Impingement Dynamics for Intelligent Spray Design

Spray cooling has high potential in thermal management and life support systems by overcoming the deleterious effect of microgravity upon two-phase heat transfer. In particular spray cooling offers several advantages in heat flux removal that include the following: 1. By maintaining a wetted surface, spray droplets impinge upon a thin fluid film rather than a dry solid surface 2. Most heat transfer surfaces will not be smooth but rough. Roughness can enhance conductive cooling, aid liquid removal by flow channeling. 3. Spray momentum can be used to a) substitute for gravity delivering fluid to the surface, b) prevent local dryout and potential thermal runaway and c) facilitate liquid and vapor removal. Yet high momentum results in high We and Re numbers characterizing the individual spray droplets. Beyond an impingement threshold, droplets splash rather than spread. Heat flux declines and spray cooling efficiency can markedly decrease. Accordingly we are investigating droplet impingement upon a) dry solid surfaces, b) fluid films, c) rough surfaces and determining splashing thresholds and relationships for both dry surfaces and those covered by fluid films. We are presently developing engineering correlations delineating the boundary between splashing and non-splashing regions.

VanderWal, Randy L.↗

Geoscience Laser Altimeter System (GLAS) Loop Heat Pipes: An Eventual First Year On-Orbit

Goddard Space Flight Center's Geoscience Laser Altimeter System (GLAS) is the sole scientific instrument on the Ice, Cloud and land Elevation Satellite (ICESat) that was launched on January 12, 2003 from Vandenberg AFB. A thermal control architecture based on propylene Loop Heat Pipe technology was developed to provide selectable/stable temperature control for the lasers and other electronics over the widely varying mission environment. Following a nominal LHP and instrument start-up, the mission was interrupted with the failure of the first laser after only 36 days of operation. During the 5-month failure investigation, the two GLAS LHPs and the electronics operated nominally, using heaters as a substitute for the laser heat load. Just prior to resuming the mission, following a seasonal spacecraft yaw maneuver, one of the LHPs deprimed and created a thermal runaway condition that resulted in an emergency shutdown of the GLAS instrument. This paper presents details of the LHP anomaly, the resulting investigation and recovery, along with on-orbit flight data during these critical events.

Grob, E.↗

Droplet-Surface Impingement Dynamics for Intelligent Spray Design

Spray cooling has high potential in thermal management and life support systems by overcoming the deleterious effect of microgravity upon two-phase heat transfer. In particular spray cooling offers several advantages in heat flux removal that include the following: 1) By maintaining a wetted surface, spray droplets impinge upon a thin fluid film rather than a dry solid surface; 2. Most heat transfer surfaces will not be smooth but rough. Roughness can enhance conductive cooling, aid liquid removal by flow channeling; and 3. Spray momentum can be used to a) substitute for gravity delivering fluid to the surface, b) prevent local dryout and potential thermal runaway and c) facilitate liquid and vapor removal. Yet high momentum results in high We and Re numbers characterizing the individual spray droplets. Beyond an impingement threshold, droplets splash rather than spread. Heat flux declines and spray cooling efficiency can markedly decrease. Accordingly we are investigating droplet impingement upon a) dry solid surfaces, b) fluid films, c) rough surfaces and determining splashing thresholds and relationships for both dry surfaces and those covered by fluid films. We are presently developing engineering correlations delineating the boundary between splashing and non-splashing regions. Determining the splash/non-splash boundary is important for many practical applications. Coating and cooling processes would each benefit from near-term empirical relations and subsequent models. Such demonstrations can guide theoretical development by providing definitive testing of its predictive capabilities. Thus, empirical relations describing the boundary between splash and non-splash are given for drops impinging upon a dry solid surface and upon a thin fluid film covering a similar surface. Analytical simplification of the power laws describing the boundary between the splash and non-splash regions yields insight into the engineering parameters governing the splash and non-splash outcomes of the fluid droplets. The power law correlation is shown separating the splashing versus non-splashing regions as developed for droplets impinging upon a dry solid surface. Splashing upon a dry surface is reasonably described by Ca greater than 0.85, reflecting the competing roles of surface tension and viscosity. The power law correlation is shown separating the splashing versus non-splashing regions as developed for droplets impinging upon a thin fluid film covering the solid surface. Splashing upon a thin fluid film, as described by v (pd/s) greater than 63, is governed by fluid density and surface tension, but is rather independent of viscosity. Finally, the data presented here suggests that a more direct dependence upon the surface tension and viscosity, given a better understanding of their interplay, would allow accurate description of the droplet-surface impacts for more complicated situations involving non-Newtonian fluids, specifically those exhibiting viscoelastic behavior.

Wal, Randy L. Vander↗

Transient Temperature Behavior of a Sphere Heated by Microwaves

We have developed a model for microwave heating of a sphere in a rectangular resonant cavity. The model calculates transient temperature distributions within a sphere during the approach to steady state conditions or on the path to thermal runaway.

microwave heating microwave absorption↗

High Specific Power Motors in LN2 and LH2

A switched reluctance motor has been operated in liquid nitrogen (LN2) with a power density as high as that reported for any motor or generator. The high performance stems from the low resistivity of Cu at LN2 temperature and from the geometry of the windings, the combination of which permits steady-state rms current density up to 7000 A/cm2, about 10 times that possible in coils cooled by natural convection at room temperature. The Joule heating in the coils is conducted to the end turns for rejection to the LN2 bath. Minimal heat rejection occurs in the motor slots, preserving that region for conductor. In the end turns, the conductor layers are spaced to form a heat-exchanger-like structure that permits nucleate boiling over a large surface area. Although tests were performed in LN2 for convenience, this motor was designed as a prototype for use with liquid hydrogen (LH2) as the coolant. End-cooled coils would perform even better in LH2 because of further increases in copper electrical and thermal conductivities. Thermal analyses comparing LN2 and LH2 cooling are presented verifying that end-cooled coils in LH2 could be either much longer or could operate at higher current density without thermal runaway than in LN2.

Brown, Gerald V.↗

High Specific Power Motors in LN2 and LH2

A switched reluctance motor has been operated in liquid nitrogen (LN2) with a power density as high as that reported for any motor or generator. The high performance stems from the low resistivity of Cu at LN2 temperature and from the geometry of the windings, the combination of which permits steady-state rms current density up to 7000 A/sq cm, about 10 times that possible in coils cooled by natural convection at room temperature. The Joule heating in the coils is conducted to the end turns for rejection to the LN2 bath. Minimal heat rejection occurs in the motor slots, preserving that region for conductor. In the end turns, the conductor layers are spaced to form a heat-exchanger-like structure that permits nucleate boiling over a large surface area. Although tests were performed in LN2 for convenience, this motor was designed as a prototype for use with liquid hydrogen (LH2) as the coolant. End-cooled coils would perform even better in LH2 because of further increases in copper electrical and thermal conductivities. Thermal analyses comparing LN2 and LH2 cooling are presented verifying that end-cooled coils in LH2 could be either much longer or could operate at higher current density without thermal runaway than in LN2.

Brown, Gerald V.↗

Current Leakage Evolution in Partially Gate Raptured Power MOSFETs

It has been observed that power MOSFETs can experience an SEGR and continue to function with altered parameters. We propose that there are three different types of SEGR modes; the micro-break, the thermal runaway, and the avalanche breakdown. Data that demonstrates these stages of device failure are presented as well as a proposed model for the micro-break. Brief discussions of the other modes, based on analysis combined with our interpretations of the older literature, are also given.

metal oxide semiconductor field-effect transistors↗

A Nanostructured Composites Thermal Switch Controls Internal and External Short Circuit in Lithium Ion Batteries

A document discusses a thin layer of composite material, made from nano scale particles of nickel and Teflon, placed within a battery cell as a layer within the anode and/or the cathode. There it conducts electrons at room temperature, then switches to an insulator at an elevated temperature to prevent thermal runaway caused by internal short circuits. The material layer controls excess currents from metal-to-metal or metal-to-carbon shorts that might result from cell crush or a manufacturing defect

McDonald, Robert C.↗