Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Intercontinental clock synchronization with the block 1 VLBI system

The Block 1 very long baseline interferometer (VLBI) operated by the Deep Space Network (DSN) to make weekly measurements of the relative epoch and rate offsets between the time standards in the global network of DSN stations is discussed. The precision of these measurements routinely achieves sub-microsecond levels for epoch offset and accuracies of better than one part in 10 to the 12th power for rate offset. The implementation of the phase calibrator system permits absolute measurement of epoch offset to better than 10 nanoseconds. With the near-real-time play-back and on-line storage of VLBI data, the Block 1 system typically produces clock parameters within 48 hours from the time of observation.

Roth, M. G.↗

Performance of the Primary Mirror Center-of-curvature Optical Metrology System During Cryogenic Testing of the JWST Pathfinder Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius-of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse & fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment & phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development & spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software & procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate & efficient cryogenic testing of the JWST flight telescope.

optical testing↗

Meteorological factors in Earth-satellite propagation

Using the COMSTAR D/4 28.56 GHz beacon as a source, a differential gain experiment was performed by connecting a 5-meter paraboloidal antenna and a 0.6-meter paraboloidal antenna alternately to the same receiver. Substantial differential gain changes were observed during some, but not all, rain events. A site-diversity experiment was implemented which consists of two 28.56 GHz radiometers separated by 9 km. The look-angle corresponds to that of the D/4 beacon, and data were obtained with one radiometer during several weeks of concurrent beacon operation to verify the system calibration. A theoretical study of the effect of scattering from a nonuniform rain distribution along the path is under way to aid in interpreting the results of this experiment. An improved empirical site diversity-gain model was derived from data in the literature relating to 34 diversity experiments. Work on the experiment control and data acquisition system is continuing with a view toward future experiments.

Levis, C. A.↗

Observational magnetometer calibration with the Hubble Space Telescope's new magnetometers

The two magnetometers recently replaced on the Hubble Space Telescope during the STS-61 Servicing Mission are now being used successfully for Coarse Attitude Determination during spacecraft vehicle safemode recovery operation. The magnetometer alignments relative to the spacecraft's vehicle's reference frame and the magnetic coupling of the sensors to the four magnetic torquer bars were determined. Coarse Attitude determination errors are now reduced to an average of 0.6 deg. Magnetometer Sensing System calibration and Coarse Attitude determination testing with the new calibration parameters is a geometrical problem. Telemetered earth magnetic field data was collected at twenty-six different vehicle attitudes. The spacecraft attitudes selected were distributed as widely apart as possible throughout the Geocentric Inertial Coordinate reference frame. It is also desirable to sample the Earth's magnetic field over as many different locations of the spacecraft's passage over the Earth as possible, within the limitation of the +/- 28.5 deg orbital inclination. A full range of magnetic moment outputs from the torquer bars needs to be sampled, +/- 3600 ampmeters squared, as well as data when the torquer bars have zero current. Graphic utilities were also developed to visually aid in optimizing the data collection process. Finally, a brief discussion of a method for collecting data for future calibrations is suggested.

Broude, Sidney M.↗

Performance of the Center-Of-Curvature Optical Assembly During Cryogenic Testing of the James Webb Space Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 meters in diameter and consists of 18 hexagonal segments, each 1.5 meters point-to-point. Each segment has a 6 degree-of-freedom hexapod actuation system and a radius-of-curvature (ROC) actuation system. The full telescope was tested at its cryogenic operating temperature at Johnson Space Center (JSC) in 2017. This testing included center-of-curvature measurements of the PM wavefront error using the Center-of-Curvature Optical Assembly (COCOA), along with the Absolute Distance Meter Assembly (ADMA). The COCOA included an interferometer, a reflective null, an interferometer-null calibration system, coarse and fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer was used to enable alignment and phasing of the PM segments. By combining measurements at two laser wavelengths, synthetic wavelengths up to 15 millimeters could be achieved, allowing mirror segments with millimeter-level piston errors to be phased to the nanometer level. The ADMA was used to measure and set the spacing between the PM and the focus of the COCOA null (i.e., the PM center-of-curvature) for determination of the ROC. This paper describes the COCOA, the PM test setup, the testing performed, the test results, and the performance of the COCOA in aligning & phasing the PM segments and measuring the final PM wavefront error.

JWST↗

Thermographic Imaging of Material Loss in Boiler Water-Wall Tubing by Application of Scanning Line Source

Localized wall thinning due to corrosion in utility boiler water-wall tubing is a significant inspection concern for boiler operators. Historically, conventional ultrasonics has been used for inspection of these tubes. This technique has proven to be very manpower and time intensive. This has resulted in a spot check approach to inspections, documenting thickness measurements over a relatively small percentage of the total boiler wall area. NASA Langley Research Center has developed a thermal NDE technique designed to image and quantitatively characterize the amount of material thinning present in steel tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source coupled with the analysis technique represents a significant improvement in the inspection speed for large structures such as boiler water-walls. A theoretical basis for the technique will be presented which explains the quantitative nature of the technique. Further, a dynamic calibration system will be presented for the technique that allows the extraction of thickness information from the temperature data. Additionally, the results of applying this technology to actual water-wall tubing samples and in situ inspections will be presented.

Cramer, K. Elliott↗

Boiler Tube Corrosion Characterization with a Scanning Thermal Line

Wall thinning due to corrosion in utility boiler water wall tubing is a significant operational concern for boiler operators. Historically, conventional ultrasonics has been used for inspection of these tubes. Unfortunately, ultrasonic inspection is very manpower intense and slow. Therefore, thickness measurements are typically taken over a relatively small percentage of the total boiler wall and statistical analysis is used to determine the overall condition of the boiler tubing. Other inspection techniques, such as electromagnetic acoustic transducer (EMAT), have recently been evaluated, however they provide only a qualitative evaluation - identifying areas or spots where corrosion has significantly reduced the wall thickness. NASA Langley Research Center, in cooperation with ThermTech Services, has developed a thermal NDE technique designed to quantitatively measure the wall thickness and thus determine the amount of material thinning present in steel boiler tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source coupled with the analysis technique represents a significant improvement in the inspection speed and accuracy for large structures such as boiler water walls. A theoretical basis for the technique will be presented to establish the quantitative nature of the technique. Further, a dynamic calibration system will be presented for the technique that allows the extraction of thickness information from the temperature data. Additionally, the results of the application of this technology to actual water wall tubing samples and in-situ inspections will be presented.

Cramer, K. Elliott↗

Calibration Technique for Polarization-Sensitive Lidars

Polarization-sensitive lidars have proven to be highly effective in discriminating between spherical and non-spherical particles in the atmosphere. These lidars use a linearly polarized laser and are equipped with a receiver that can separately measure the components of the return signal polarized parallel and perpendicular to the outgoing beam. In this work we describe a technique for calibrating polarization-sensitive lidars that was originally developed at NASA s Langley Research Center (LaRC) and has been used continually over the past fifteen years. The procedure uses a rotatable half-wave plate inserted into the optical path of the lidar receiver to introduce controlled amounts of polarization cross-talk into a sequence of atmospheric backscatter measurements. Solving the resulting system of nonlinear equations generates the system calibration constants (gain ratio, G, and offset angle, theta) required for deriving calibrated measurements of depolarization ratio from the lidar signals. In addition, this procedure also determines the mean depolarization ratio within the region of the atmosphere that is analyzed. Simulations and error propagation studies show the method to be both reliable and well behaved. Operational details of the technique are illustrated using measurements obtained as part of Langley Research Center s participation in the First ISCCP Regional Experiment (FIRE).

Alvarez, J. M.↗

The molecular branching ratio method for calibration of optical systems in the vacuum ultraviolet

The intensity distribution of bands belonging to six molecular band systems is discussed with special emphasis on their usefulness for intensity calibration of optical systems in the vacuum ultraviolet (1000A Lambda 3000A). The theory of molecular band intensities is outlined and the technique of measuring the spectral response curve is described. Several methods for establishing an absolute intensity calibration are discussed.

Mumma, M. J.↗

Landsat-8 Operational Land Imager On-Orbit Radiometric Calibration

The Operational Land Imager (OLI), the VIS/NIR/SWIR sensor on the Landsat-8 has been successfully acquiring Earth Imagery for more than four years. The OLI incorporates two on-board radiometric calibration systems, one diffuser based and one lamp based, each with multiple sources. For each system one source is treated as primary and used frequently and the other source(s) are used less frequently to assist in tracking any degradation in the primary sources. In addition, via a spacecraft maneuver, the OLI instrument views the moon once a lunar cycle (approx. 29 days). The integrated lunar irradiances from these acquisitions are compared to the output of a lunar irradiance model. The results from all these techniques, combined with cross calibrations with other sensors and ground based vicarious measurements are used to monitor the OLI's stability and correct for any changes observed. To date, the various techniques have other detected significant changes in the shortest wavelength OLI band centered at 443 nm and these are currently being adjusted in the operational processing.

radiometric calibratio↗

Progress of magnetic suspension and balance systems for wind tunnels in the USSR

Magnetic Suspension and Balance Systems (MSBS) for wind tunnels are being developed in order to solve the principal problems of aerodynamics which cannot be solved by conventional means: (1) measurements of aerodynamic loads acting on the aircraft models without the effects of mechanical supporting devices; and (2) the study of base pressure. This paper traces the progress of MSBS for wind tunnels in the Commonwealth of Independent States (CIS). The paper describes electromagnetic configuration, position sensing, and control and calibration systems of two wind tunnel MSBS existing in the CIS. The features of high-angle-of-attack control and roll control are discussed. The results of preliminary experiments on high-angle-of-attack and roll controls, digital control, and aerodynamic testing are also presented.

Kuzin, A. V.↗

Soil Moisture Active Passive (SMAP) Project Assessment Report for Version 4 of the L4_SM Data Product

This report provides an assessment of Version 4 of the SMAP Level 4 Surface and Root Zone Soil Moisture (L4_SM) product, released on 14 June 2018. The assessment includes comparisons of L4_SM soil moisture and temperature estimates with in situ measurements from core validation sites and sparse networks. The assessment further includes a global evaluation of the internal diagnostics from the ensemble-based data assimilation system that is used to generate the L4_SM product, including observation-minus-forecast (O-F) brightness temperature residuals and soil moisture analysis increments.Together, the core validation site comparisons and the statistics of the assimilation diagnostics areconsidered primary validation methodologies for the L4_SM product. Comparisons against in situ measurements from regional-scale sparse networks are considered a secondary validation methodology because such in situ measurements are subject to upscaling errors from the point-scale to the grid-cell scale of the data product.The Version 4 L4_SM product benefits from an improved land surface modeling system and from retrospective surface meteorological forcing data that are as consistent as possible with the present-day datain terms of their climatology. Specifically, the model changes include revised parameters and parameterizations for (i) the surface energy balance, (ii) recharge from below of the model's surface excess reservoir, and (iii) the snow depletion curve. Updated ancillary inputs include improved datasets for landcover, topography, and vegetation height. The Version 4 algorithm further includes a revised approach to precipitation corrections that improves the precipitation climatology in Africa and the high-latitudes. Moreover, for system calibration the model is forced retrospectively with MERRA-2 reanalysis data, which are more consistent with the near-real time GEOS forward processing (FP) data used during the SMAP period than the retrospective GEOS data that were available for previous L4_SM versions. An analysis of the time-average surface and root zone soil moisture shows that the global pattern ofarid and humid regions is captured by the Version 4 L4_SM estimates. Owing to the changes in the landsurface modeling system, surface soil moisture is typically drier by several volumetric percent in Version 4 compared to Version 3, whereas root zone soil moisture is wetter in Version 4 in some regions and drierin others. Because of these climatological differences, the Version 3 and Version 4 products should not be combined into a single dataset for use in applications.Results from the core validation site comparisons indicate that Version 4 of the L4_SM data product meets the self-imposed L4_SM accuracy requirement, which is formulated in terms of the RMSE after removal of the long-term mean difference (ubRMSE). The overall ubRMSE of the 3-hourly L4_SM dataat the 9 km scale is 0.039 m3 m-3 for surface soil moisture and 0.029 m3 m-3 for root zone soil moisture,below the 0.04 m3 m-3 requirement. The L4_SM estimates are an improvement over estimates from a model-only Nature Run version 7.2 (NRv7.2), which demonstrates the beneficial impact of the SMAP brightness temperature data. Overall, L4_SM surface and root zone soil moisture estimates are more skillful than NRv7.2 estimates, with statistically significant improvements at the 5% level for surface soil moisture R and anomaly R values. Results from comparisons of the L4_SM product to i

Reichle, Rolf H.↗

Development report: Automatic System Test and Calibration (ASTAC) equipment

A microcomputer based automatic test system was developed for the daily performance monitoring of wind energy system time domain (WEST) analyzer. The test system consists of a microprocessor based controller and hybrid interface unit which are used for inputing prescribed test signals into all WEST subsystems and for monitoring WEST responses to these signals. Performance is compared to theoretically correct performance levels calculated off line on a large general purpose digital computer. Results are displayed on a cathode ray tube or are available from a line printer. Excessive drift and/or lack of repeatability of the high speed analog sections within WEST is easily detected and the malfunctioning hardware identified using this system.

Thoren, R. J.↗

Radio Doppler navigation of interplanetary spacecraft using different data processing modes

Doppler shift measurements derived from closed-loop radio tracking of distant spacecraft by ground stations of the Deep Space Network (DSN) are one of the principal means used for interplanetary navigation. This paper describes an investigation of the navigation accuracy that can be achieved with two-way coherent X-band (7.2 to 8.4 GHz) Doppler phase and frequency data; both theoretical and practical aspects of the two Doppler formulations are addressed. A new filtering strategy is also proposed, which differs from current approaches in that most of the ground system calibration errors affecting the Doppler data are represented as filter parameters, in addition to the spacecraft trajectory parameters. Error covariance computations for application of the proposed filter to a navigation scenario derived from the Mars Observer mission are provided, in order to assess the performance that might be obtained in practice. The results indicate that with a phase formulation of the Doppler data and the new filter, navigation accuracies of 15 km at Mars (0.05 microrad in an angular sense) are possible with the DSN's present X-band Doppler tracking system.

Thurman, S. W.↗

Evaluation of the Sensor Data Record from the Nadir Instruments of the Ozone Mapping Profiler Suite (OMPS)

This paper evaluates the first 15 months of the Ozone Mapping and Profiler Suite (OMPS) Sensor Data Record (SDR) acquired by the nadir sensors and processed by the National Oceanic and Atmospheric Administration Interface Data Processing Segment. The evaluation consists of an inter-comparison with a similar satellite instrument, an analysis using a radiative transfer model, and an assessment of product stability. This is in addition to the evaluation of sensor calibration and the Environment Data Record product that are also reported in this Special Issue. All these are parts of synergetic effort to provide comprehensive assessment at every level of the products to ensure its quality. It is found that the OMPS nadir SDR quality is satisfactory for the current Provisional maturity. Methods used in the evaluation are being further refined, developed, and expanded, in collaboration with international community through the Global Space-based Inter-Calibration System, to support the upcoming long-term monitoring.

validation↗

Remote sensing technology - The 24-channel multispectral scanner.

The multispectral scanner system installed in the NASA C-130 aircraft for use in the Earth Observations Aircraft Program constitutes a 24-channel imaging spectrometer that senses electromagnetic energy in the spectral interval from .34 to 13 microns. Energy reflected or emitted from the terrain and system calibration sources is collected by a scan mirror, reflected into collecting optics, and brought to a focus in a plane containing a 0.09 inch square aperture. A dichroic optical element splits the energy which passes through the aperture into two wavelength bands (wavelengths above and below 2 microns). These wavelength bands are then dispersed spectrally into 24 distinct spectral bands by two grating spectrometers. The spectral intervals are transformed into electrical signals by separate detector-preamplifier combinations, and the signals are used as inputs to a video processor in an airborne electronics console. System operation and performance are described.

Hayre, H. S.↗

NEXT Propellant Management System Integration With Multiple Ion Thrusters

As a critical part of the NEXT test validation process, a multiple-string integration test was performed on the NEXT propellant management system and ion thrusters. The objectives of this test were to verify that the PMS is capable of providing stable flow control to multiple thrusters operating over the NEXT system throttling range and to demonstrate to potential users that the NEXT PMS is ready for transition to flight. A test plan was developed for the sub-system integration test for verification of PMS and thruster system performance and functionality requirements. Propellant management system calibrations were checked during the single and multi-thruster testing. The low pressure assembly total flow rates to the thruster(s) were within 1.4 percent of the calibrated support equipment flow rates. The inlet pressures to the main, cathode, and neutralizer ports of Thruster PM1R were measured as the PMS operated in 1-thruster, 2-thruster, and 3-thruster configurations. It was found that the inlet pressures to Thruster PM1R for 2-thruster and 3-thruster operation as well as single thruster operation with the PMS compare very favorably indicating that flow rates to Thruster PM1R were similar in all cases. Characterizations of discharge losses, accelerator grid current, and neutralizer performance were performed as more operating thrusters were added to the PMS. There were no variations in these parameters as thrusters were throttled and single and multiple thruster operations were conducted. The propellant management system power consumption was at a fixed voltage to the DCIU and a fixed thermal throttle temperature of 75 C. The total power consumed by the PMS was 10.0, 17.9, and 25.2 W, respectively, for single, 2-thruster, and 3-thruster operation with the PMS. These sub-system integration tests of the PMS, the DCIU Simulator, and multiple thrusters addressed, in part, the NEXT PMS and propulsion system performance and functionality requirements.

Sovey, James S.↗

The Astro-E2 Mission

The Astro-E2 observatory is a rebuild of the original Astro-E observatory that was lost during launch in February 2000. It is scheduled for launch into low earth orbit on a Japanese M-V rocket in early 2005. The Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, is developing the observatory with major contributions from the US. The three instruments on the observatory are the high-resolution x-ray spectrometer (the XRS) featuring a 30-pixel x-ray microcalorimeter array, a set of four CCD cameras (the XIS) and a combination photo-diode/scintillator detector system (the HXD) that will extend the band pass up to nearly 700 keV. A significant feature of Astro-E2 is that all of the instruments are coaligned and operated simultaneously. With its high spectral resolution and collecting area for spectroscopy above 1 keV, Astro-E2 should enable major discovery space and pioneer new technology for use in space. Prime areas for investigation are supernova remnants, active galaxies and the measurement of black hole properties via relativistically-broadened Fe-K emission galaxies. A number of enhancements have been made for the Astro-E2/XRS, including a higher resolution microcalorimeter array, ii mechanical cooler for longer cryogen life, and an improved in-flight calibration system. The Astro-E2/XIS has also been improved to include two back-side-illuminated CCDs to enhance the low energy response. Improvements have also been made to the x-ray mirrors used for both the XRS and XIS to sharpen the point spread function and reduce the effects of stray light. In this talk we will present the essential features of Astro-E2, paying particular attention to the enhancements, and describe the major scientific strengths of the observatory.

Kelley, Richard L.↗