Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Real-time visualization of particle evolution during reactive flux-assisted processing of aluminum melts

Here, a multi-modal, multi-scale correlative tomography investigation of Al-TiC metal matrix composites processed via flux-assisted reaction synthesis is reported. Synchrotron X-ray microradiography is utilized to visualize the reaction and particle evolution in real-time. Changes in particle diameter and areal number density suggest that the process is nucleation- rather than growth-dominated. At 950 °C, the bulk of the reaction takes place in a relatively short time span of less than 600 s. The microstructure is imaged at higher resolution in 2D (scanning electron microscopy) and 3D (synchrotron X-ray nanotomography), revealing the formation of carbide particles with a hexagonal platelet morphology. We propose that the morphology arises due to the incorporation of Si impurities during the experiment. It is expected that the correlative tomography workflow and analysis may guide future metal matrix composite (MMC) processing strategies.

36 MATERIALS SCIENCE↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of glutathione-coated Mn-doped ZnS quantum dots on nutrient delivery in basil ( Ocimum basilicum ) plants

Ensuring efficient nutrient delivery while minimizing environmental impacts remains a significant challenge for modern agriculture. Nanotechnology-based fertilizers offer promising strategies to improve nutrient uptake and bioavailability in plants. This research aims to evaluate the use of Glutathione-coated Manganese-doped Zinc Sulfide quantum dots (GSH-ZnS-Mn QDs) as a potential nano fertilizer for basil (Ocimum basilicum). QDs' physicochemical properties were characterized using UV–Vis spectroscopy, photoluminescence, FTIR, and energy-dispersive X-ray spectroscopy, confirming successful Mn doping and glutathione surface functionalization. Basil plants were exposed to different concentrations of GSH-ZnS-Mn QDs under soil and hydroponic conditions. Plant growth parameters, oxidative stress responses, photosynthetic pigments, and macro- and micronutrient uptake were assessed using biochemical assays and inductively coupled plasma optical emission spectrometry (ICP-OES). Elemental uptake, spatial distribution, and zinc speciation were further investigated using synchrotron-based micro-X-ray fluorescence (μ-XRF) imaging and X-ray absorption near-edge structure (XANES) spectroscopy. Results show that exposure to GSH-ZnS-Mn QDs resulted in a concentration-dependent increase in leaf and stem biomass, accompanied by enhanced Zn accumulation in plant tissues. Catalase activity decreased across all tested concentrations, suggesting a shift toward glutathione-dependent antioxidant pathways rather than oxidative damage. Chlorophyll levels exhibited moderate reductions at higher concentrations. The higher increase in macronutrient (K, Ca, and Mg) uptake was reported in plants exposed to 200 ppm of QDs. μ-XRF imaging indicated a selective accumulation of Zn in roots and stems, with partial translocation to leaves. XANES analyses revealed that Zn from QDs was mainly converted into organic Zn species, such as Zn-phytate, Zn-acetate, and Zn-cysteine, indicating transformation and complexation within the plant. The findings demonstrate that a glutathione coating on GSH-ZnS-Mn QDs improves biocompatibility and nutrient delivery efficiency. These results highlight the relevance of surface functionalization in regulating nanoparticle fate, transformation, and nutrient bioavailability, supporting the potential application of GSH–ZnS–Mn QDs as modern nano fertilizers.

Basil↗

Evaluation of quantitative synchrotron radiation micro-X-ray fluorescence in rice grain

Concentrations of nutrients and contaminants in rice grain affect human health, specifically through the localization and chemical form of elements. Methods to spatially quantify the concentration and speciation of elements are needed to protect human health and characterize elemental homeostasis in plants. Here, an evaluation was carried out using quantitative synchrotron radiation microprobe X-ray fluorescence (SR-µXRF) imaging by comparing average rice grain concentrations of As, Cu, K, Mn, P, S and Zn measured with rice grain concentrations from acid digestion and ICP-MS analysis for 50 grain samples. Better agreement was found between the two methods for high-Z elements. Regression fits between the two methods allowed quantitative concentration maps of the measured elements. These maps revealed that most elements were concentrated in the bran, although S and Zn permeated into the endosperm. Arsenic was highest in the ovular vascular trace (OVT), with concentrations approaching 100 mg kg –1 in the OVT of a grain from a rice plant grown in As-contaminated soil. Quantitative SR-µXRF is a useful approach for comparison across multiple studies but requires careful consideration of sample preparation and beamline characteristics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Operando 3D imaging of defects dynamics of twinned-nanocrystal during catalysis

Using operando Bragg coherent x-ray diffraction imaging, we visualised three-dimensionally a single twinned-gold nanocrystal during the CO oxidation reaction. We describe the defect dynamics process occurring under operating conditions and indicate the correlation between the nucleation of highly strained regions at the surface of the nanocrystal and its catalytic activity. Understanding the twinning deformation mechanism sheds light on the creation of active sites, and could well contribute to the understanding of the catalytic behaviour of other catalysts. Furthermore, with the start-up of 4th generation synchrotron sources, we anticipate that coherent hard x-ray diffraction imaging techniques will play a major role in imaging in situ chemical processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-time data processing for serial crystallography experiments

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework. In a series of user experiments at PETRA III, frames from a 16 megapixel Dectris EIGER2 X detector were searched for peaks, indexed and integrated at the maximum full-frame readout speed of 133 frames per second. The computational resources required depend on various factors, most significantly the fraction of non-blank frames ('hits'). The average single-thread processing time per frame was 242 ms for blank frames and 455 ms for hits, meaning that a single 96-core computing node was sufficient to keep up with the data, with ample headroom for unexpected throughput reductions. Further significant improvements are expected, for example by binning pixel intensities together to reduce the pixel count. We discuss the implications of real-time data processing on the `data deluge' problem from recent and future photon-science experiments, in particular on calibration requirements, computing access patterns and the need for the preservation of raw data.

47 OTHER INSTRUMENTATION↗

The persistent shadow of the supermassive black hole of M87. II. Model comparisons and theoretical interpretations

The Event Horizon Telescope (EHT) observation of M87∗ in 2018 has revealed a ring with a diameter that is consistent with the 2017 observation. The brightest part of the ring is shifted to the southwest from the southeast. In this paper, we provide theoretical interpretations for the multi-epoch EHT observations for M87∗ by comparing a new general relativistic magnetohydrodynamics model image library with the EHT observations for M87∗ in both 2017 and 2018. The model images include aligned and tilted accretion with parameterized thermal and nonthermal synchrotron emission properties. The 2018 observation again shows that the spin vector of the M87∗ supermassive black hole is pointed away from Earth. A shift of the brightest part of the ring during the multi-epoch observations can naturally be explained by the turbulent nature of black hole accretion, which is supported by the fact that the more turbulent retrograde models can explain the multi-epoch observations better than the prograde models. The EHT data are inconsistent with the tilted models in our model image library. Assuming that the black hole spin axis and its large-scale jet direction are roughly aligned, we expect the brightest part of the ring to be most commonly observed 90 deg clockwise from the forward jet. This prediction can be statistically tested through future observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating the effect of electric fields on lead halide perovskites by scanning tunneling microscopy

Lead halide perovskites have emerged as promising absorber materials over the last decade to increase the efficiency of photovoltaics beyond its current limits. However, to further optimize the performance of perovskites, more detailed studies need to be performed which allow for the correlation of film morphology and local electronic properties at the nanoscale. In this paper, we present a scanning tunneling microscopy (STM) approach to probe the effect of an applied electric field of a methylammonium formamidinium lead triiodide perovskite thin film on the film response by current-voltage spectroscopy, current imaging tunneling spectroscopy, differential conductance mapping and X-ray absorption spectroscopy (XAS) by means of synchrotron X-ray STM (SX-STM). We find a strong correlation between the measurement conditions and the obtained current-voltage characteristics when imaging under opposite applied bias polarities. In particular, we find similarities to already observed poling effects for perovskites which result in either a positively or negatively charged interface due to ion and vacancy migration. Our results provide insight into the influence of measurement conditions such as bias polarity on the performance assessment of perovskite thin films by STM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Longitudinal Phase Space Tomography for the Booster Synchrotron

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography had been employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor signal, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted; Fermilab]↗

MemXCT: Design, Optimization, Scaling, and Reproducibility of X-Ray Tomography Imaging

Here, this work extends our previous research entitled "MemXCT: Memory-centric X-ray CT Reconstruction with Massive Parallelization" that was originally published at SC19 conference (Hidayetoglu et al., 2019) with reproducibility of the computational imaging performance. X-ray computed tomography (XCT) is regularly used at synchrotron light sources to study the internal morphology of materials at high resolution. However, experimental constraints, such as radiation sensitivity, can result in noisy or undersampled measurements. Further, depending on the resolution, sample size and data acquisition rates, the resulting noisy dataset can be in the order of terabytes. Advanced iterative reconstruction techniques can produce high-quality images from noisy measurements, but their computational requirements have made their use an exception rather than the rule. We propose a novel memory-centric approach that avoids redundant computations at the expense of additional memory complexity. We develop a memory-centric iterative reconstruction system, MemXCT, that uses an optimized SpMV implementation with two-level pseudo-Hilbert ordering and multi-stage input buffering. We evaluate MemXCT on various supercomputer architectures involving KNL and GPU. MemXCT can reconstruct a large (11Kx11K) mouse brain tomogram in 10 seconds using 4096 KNL nodes (256K cores). The results presented in our original article at the SC19 were based on large-scale supercomputing resources. The MemXCT application was selected for the Student Cluster Competition (SCC) Reproducibility Challenge and evaluated on a variety of cloud computing resources by universities around the world in the SC20 conference. We summarize the results of the top-ranked SCC Reproducibility Challenge teams and identify the most pertinent measures for ensuring the reproducibility of our experiments in this article.

47 OTHER INSTRUMENTATION↗

Characterization of Si particles in additively manufactured AlSi10Mg using synchrotron transmission X-ray nanotomography

In AlSi10Mg samples manufactured by Laser Powder Bed Fusion, distinguishing the Si eutectic network/Si particles from the Al matrix by X-ray imaging is challenging due to the low absorption contrast between the Al and Si. This work investigates the possibility of overcoming this obstacle in synchrotron transmission X-ray microscopy. Effects of both different defocusing conditions and X-ray beam energies are evaluated and optimal conditions are identified for imaging a sample annealed post-print for 2h at 520°C. It is shown that both large particles (e.g. 4μm) and particles as small as 0.5 μm, can be imaged with reasonable precision in 3D non-destructively.

Defer, M.↗

T staging esophageal tumors with x rays

With histopathology results typically taking several days, the ability to stage tumors during interventions could provide a step change in various cancer interventions. X-ray technology has advanced significantly in recent years with the introduction of phase-based imaging methods. These have been adapted for use in standard labs rather than specialized facilities such as synchrotrons, and approaches that enable fast 3D scans with conventional x-ray sources have been developed. This opens the possibility to produce 3D images with enhanced soft tissue contrast at a level of detail comparable to histopathology, in times sufficiently short to be compatible with use during surgical interventions. In this paper we discuss the application of one such approach to human esophagi obtained from esophagectomy interventions. We demonstrate that the image quality is sufficiently high to enable tumor T staging based on the x-ray datasets alone. Alongside detection of involved margins with potentially life-saving implications, staging tumors intra-operatively has the potential to change patient pathways, facilitating optimization of therapeutic interventions during the procedure itself. Besides a prospective intra-operative use, the availability of high-quality 3D images of entire esophageal tumors can support histopathological characterization, from enabling “right slice first time” approaches to understanding the histopathology in the full 3D context of the surrounding tumor environment.

Optics↗

Longitudinal Phase Space Tomography for the Booster Synchrotron

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted]↗

In situ detection of ferric reductase activity in the intestinal lumen of an insect

The rise of atmospheric oxygen as a result of photosynthesis in cyanobacteria and chloroplasts has transformed most environmental iron into the ferric state. In contrast, cells within organisms maintain a reducing internal milieu and utilize predominantly ferrous iron. Ferric reductases are enzymes that transfer electrons to ferric ions, either extracellularly or within endocytic vesicles, enabling cellular ferrous iron uptake through Divalent Metal Transporter 1. In mammals, duodenal cytochrome b is a ferric reductase of the intestinal epithelium, but how insects reduce and absorb dietary iron remains unknown. Here we provide indirect evidence of extracellular ferric reductase activity in a small subset of Drosophila melanogaster intestinal epithelial cells, positioned at the neck of the midgut’s anterior region. Dietary-supplemented bathophenanthroline sulphate (BPS) captures locally generated ferrous iron and precipitates into pink granules, whose chemical identity was probed combining in situ X-ray absorption near edge structure and electron paramagnetic resonance spectroscopies. An increased presence of manganese ions upon BPS feeding was also found. Control animals were fed with ferric ammonium citrate, which is accumulated into ferritin iron in distinct intestinal subregions suggesting iron trafficking between different cells inside the animal. Spectroscopic signals from the biological samples were compared to purified Drosophila and horse spleen ferritin and to chemically synthesized BPS-iron and BPS-manganese complexes. The results corroborated the presence of BPS-iron in a newly identified ferric iron reductase region of the intestine, which we propose constitutes the major site of iron absorption in this organism.

EPR↗

Cerebellar dysfunction in a mouse model of childhood-onset manganese-induced dystonia parkinsonism

Humans with pathogenic variants of the manganese (Mn) transporter gene SLC39A14 exhibit highly elevated brain Mn concentrations and childhood-onset dystonia-parkinsonism. Here we show that Slc39a14-knockout (KO) mice, a preclinical model of the disease with elevated Mn concentrations in the CB, express deficits in physiological tremor implicating cerebellar (CB) dysfunction. Imaging of intracellular Mn in Purkinje cells (PCs) using synchrotron-based X-ray fluorescence microscopy confirmed highly elevated Mn concentrations in the PCs of Slc39a14-KO mice. To determine biological pathways altered in the CB of Slc39a14-KO mice relative to wildtype (WT), we performed RNA sequencing and discovered significant upregulation of pathways and genes regulating immune response and cell death. To substantiate these findings, we performed quantitative autoradiography of the neuroinflammation biomarker Translocator Protein 18 kDa (TSPO) which was significantly increased in the CB of Slc39a14-KO mice relative to WT. The latter findings were confirmed via immunostaining with the microglial marker Iba-1, revealing widespread microglia activation and clustering in the CB cortex. Immunostaining for cleaved caspase-3 (cCASP3), a marker of apoptosis, showed increased number of PCs with positive immunolabeling for cCASP3 in Slc39a14-KO mice relative to WT. Degeneration of PCs was confirmed by Hematoxylin and Eosin (H&E) staining. Lastly, functional electrophysiological assessment of CB neurocircuitry revealed a marked decrease in firing rates of cerebellar nuclei (CN) neurons and increased variability of PC simple spikes firing. Collectively, these findings show, for the first time, Mn-induced PC degeneration and dysfunctional CB circuitry in Slc39a14-KO mice providing additional evidence for the pathological underpinnings of the dystonia-like movements, balance, and gait abnormalities in SLC39A14 mutation carriers.

36 MATERIALS SCIENCE↗

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as a whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared with the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, a laminography pipeline for imaging large samples (>1 cm) at micrometre resolution is presented. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source. Additionally, sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets are presented. The applicability of the whole laminography pipeline was demonstrated by imaging four sequential slabs throughout an entire mouse brain sample stained with osmium, in total generating approximately 12 TB of raw data for reconstruction.

47 OTHER INSTRUMENTATION↗

X-ray phase contrast and absorption imaging for the quantification of transient cavitation in high-speed nozzle flows

In this work, high-flux synchrotron radiation has been employed in a time-resolved manner to characterise the distinct topology features and dynamics of different cavitation regimes arising in a throttle orifice with an abrupt flow-entry contraction. Radiographs obtained though both X-ray phase- contrast and absorption imaging have been captured at 67,890 frames per second. The flow lied in the turbulent regime (Re=35,500), while moderate (CN=2.0) to well-established (CN=6.0) cavitation conditions were examined encompassing the cloud and vortical cavitation regimes with pertinent transient features, such as cloud-cavity shedding. X-ray Phase-Contrast Imaging (XPCI), exploiting the shift in the X-ray wave phase during interactions with matter, offers sharp-refractive index gradients in the interface region. Hence, it is suitable for capturing fine morphological fluctuations of transient cavitation structures. Nevertheless, the technique cannot provide information on the quantity of vapour within the orifice. Such data have been obtained utilising absorption imaging, where beam attenuation is not associated with scattering and refraction events, and hence can be explicitly correlated with the projected vapour thickness in line-of-sight measurements. A combination of the two methods is proposed, as it has been found is capable of quantifying the vapour content arising in the complex nozzle flow, while also faithfully illustrating the dynamics of the highly-transient cavitation features.

42 ENGINEERING↗

Longitudinal Phase Space Tomography for the Booster Synchrotron (Abstract Only)

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted, US]↗