Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchronous generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Mean-field equation for phase-modulated optical parametric oscillator

The widely established techniques for the generation of ultrashort optical pulses rely on passive mode locking of lasers, with the output pulse duration and emission spectrum determined by the intrinsic lifetime of laser transition in the gain medium. Due to the instantaneous nature of nonlinear gain, optical parametric oscillators (OPOs) are capable of generating optical radiation in all timescales from continuous-wave (cw) to ultrashort femtosecond regime, if driven by laser pump sources in the corresponding time domain. In the ultrashort timescale, operation of OPOs conventionally relies on mode-locked pump lasers, with the concomitant disadvantages of large footprint and high cost. At the same time, the lack of gain storage mandates the use of synchronous pumping, resulting in increased complexity. In this paper, we present the concept of phase-modulated OPO driven by cw pump laser. The approach overcomes the traditional drawbacks of ultrafast OPOs, enabling femtosecond pulse generation without the need for synchronous pumping, resulting in a simplified, compact, and cost-effective architecture using cw input pump lasers. We derive a mean-field equation for a degenerate χ ( 2 ) OPO driven by a cw laser with intracavity electro-optic modulator (EOM), and also including dispersion compensation. The equation predicts the formation of stable femtosecond pulses ( < 200 fs ) , in both normal and anomalous dispersion regimes, with a controllable repetition rate determined by the frequency of the EOM. The remarkable functionality of the proposed scheme paves the way for the development of an alternative class of widely tunable coherent femtosecond light sources in both bulk and integrated format based on χ ( 2 ) OPOs using cw pump lasers. Published by the American Physical Society 2024

Sanchez, A. D. (ORCID:0000000327630339)↗

A field programmable gate array-based timing and control system for the dynamic compression sector

A field programmable gate array (FPGA)-based timing and trigger control system has been developed for the Dynamic Compression Sector (DCS) user facility located at the Advanced Photon Source (APS) at Argonne National Laboratory. The DCS is a first-of-its-kind capability dedicated to dynamic compression science. All components of the DCS laser shock station—x-ray choppers, single-shot shutter, internal laser triggers, and shot diagnostics—must be synchronized with respect to the arrival of x rays in the hutch. An FPGA synchronized to the APS storage ring radio frequency clock (352 MHz) generates trigger signals for each stage of the laser and x-ray shutter system with low jitter. The developed FPGA-based control system was the first system used to control the laser and the shutter system since its commissioning, and it has been developing since then to improve the timing jitter. The system is composed of a Zynq FPGA, a debug card, line drivers, and a power supply. The delay and offsets of the trigger signals can be adjusted by using a user-friendly graphical user interface with high precision. Here, the details of the system architecture, timing requirements, firmware, and software implementation along with the performance evaluation are presented in this paper. The system offers low timing jitter (15.5 ps rms) with respect to the APS 352 MHz clock, suitable for the 100 ps (FWHM) x-ray bunch duration at the APS.

47 OTHER INSTRUMENTATION↗

Unified Model of Current-Limiting Grid-Forming Inverters for Large-Signal Analysis

Grid-forming (GFM) inverters can hardly withstand any overloading. As such, GFM inverters need a current limiter in their control system to avoid hardware damage during overloading or grid disturbances. When the current limiter is engaged for inverter protection, however, it dynamically changes the inverter output impedance, which can significantly affect the system behavior against large disturbances. For example, when the current limiter curtails the output power, the primary controller of the GFM inverter-which generates the voltage and angle reference-is prone to losing synchronization with the grid. This can cause large-signal instability in the network. This paper presents a unified GFM current-limiter model to gain a deeper understanding of the impact of the GFM inverter current limiting on large-signal instability and other system behaviors. The unified model captures several well-known current limiters for GFM inverters, and it reveals their large-signal equivalence characterized by the limiter angle. We use the unified model to present in-depth insights into the driving forces that cause large-signal instability in GFM inverter-driven grids. Further, this paper illustrates that the unified model can be used as a tool for assessing the system-level impacts of various GFM current-limiter designs during grid disturbances. Using numerical, analytical, electromagnetic transient models, and a hardware setup, the validity of the unified model is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dual Event Generator (dual-evg) v1.0

The dual event generator is a event-based timing system implementation capable of synchronizing (with respect to clock, events and triggers) hundreds of downstreams devices. This has been in use by ALS for many years and this is a similar implementation, but with a synchronized dual-master frequency , as opposed to just one in a more conventional approach.

Russo, Lucas↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗

Pulsar Based Timing for Grid Synchronization

Existing synchronization systems in the power grid, such as the global positioning system, are susceptible to temporary or permanent failures due to various unpredictable and uncontrollable factors such as cyber-attack and electromagnetic interferences, thus affecting the accuracy and reliability of generated timing signal. In this article, a pulsar astronomy-based timing system is proposed to provide an alternative synchronization signal. Further, this clock will offer significant security improvements to power grid applications, such as a wide-area monitoring system, which depends on a precise timing signal. The hardware and software frameworks are described in detail. First, a high-speed sampling hardware platform is designed to collect signals from radio telescopes. Then a periodic pulse extraction method with three steps is proposed to process the pulsar signal, including polyphase filterbanks, incoherent de-dispersion, and sliding window folding. Lastly, three experiments are conducted to verify the effectiveness of the frameworks. The generated pulsar timing pulse is presented, and the factors affecting its accuracy are also discussed. The analysis results demonstrate that the pulsar signals can provide high-accurate timing pulses for grid synchronization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Event Fanout/Receiver (evfr) v1.0

The event fanout-receiver is an event-based timing system implementation capable of synchronizing (with respect to clock, events and triggers) to an upstream event generator. This can be used in 2 modes: fanout or receiver. the first one receives 1 upstream timing streams and fanouts it to 36. The second one receives and decodes the stream. This has been in use by ALS for many years and this is a similar implementation, but providing a more flexible configuration

Russo, Lucas↗

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE↗

Coupled Electro-Thermal Analysis of Permanent Magnet Synchronous Motor for Electric Vehicles

Permanent magnet synchronous motors (PMSM) are extensively used in electric vehicles. However, high internal heat generation and inefficient heat dissipation often limit the operational reliability, and longevity of the PMSM. Therefore, proper quantification of heat generation in electric motor and advanced embedded motor cooling techniques remain topics of immense interest. In order to accurately predict electro-magnetic performance, i.e., efficiency, component-wise heat losses and the corresponding temperature distribution of a jacket cooled machine, this paper presents a two-way iteratively coupled electro-thermal modeling framework. Finite element based software Motor-CAD has been utilized for electro-magnetic performance calculation of BMW i3 PMSM. Finite volume based computational fluid dynamics/heat transfer (CFD/HT) software ANSYS® FLUENT® has been employed to simulate the temperature distribution of the PMSM, using the electro-magnetic losses as heat input. Computed heat losses, stator, winding, rotor, and magnet temperatures are utilized as coupling parameters between the electro-magnetic and thermal models. A conventional one-way coupling algorithm has also been developed and compared to the newly proposed two-way coupling algorithm. Numerical results confirm that at high current density, one-way coupling algorithm significantly over-predicts the motor temperature compared to the two-way algorithm. A comprehensive analysis has been carried out to characterize the influences of current density, speed, and forced convection heat transfer coefficient on the heat losses, overall efficiency, and maximum temperature of the PMSM. Lastly, an efficiency map has been interpreted from the coupled electro-magnetic simulation.

42 ENGINEERING↗

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Practical Start-Up Process of Multiple Grid-Tied Voltage-Sourced Inverters in Laboratory

Starting up inverter-based resources (IBRs) and integrating them into a grid are important in real-world engineering and there are many challenges to be tackled. Using a laboratory-scale hardware test bed (50 Watt and 20 V), this paper demonstrates the challenges and provides a practical start-up process that can smoothly energize two grid-tied voltage-sourced inverters (VSI) and synchronize the VSIs into a 60-Hz grid. The hardware test bed consists of two SiC VSIs and a 45-kW Chroma grid simulator to act as the grid. The inverter controls are implemented in OPAL-RT OP5600, which has the measurements sensed, control algorithms processed, and gate signals generated and sent to the VSI switches. This research focuses on examining how to energize VSIs and how to synchronize the VSIs into the grid. The best energizing approach is summarized based on comparison and analysis of the experiment results. The presented approach can prevent large transients during the start-up process.

Wang, Zhengyu↗

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Progress in Hybrid Plasma Wakefield Acceleration

Plasma wakefield accelerators can be driven either by intense laser pulses (LWFA) or by intense particle beams (PWFA). A third approach that combines the complementary advantages of both types of plasma wakefield accelerator has been established with increasing success over the last decade and is called hybrid LWFA→PWFA. Essentially, a compact LWFA is exploited to produce an energetic, high-current electron beam as a driver for a subsequent PWFA stage, which, in turn, is exploited for phase-constant, inherently laser-synchronized, quasi-static acceleration over extended acceleration lengths. The sum is greater than its parts: the approach not only provides a compact, cost-effective alternative to linac-driven PWFA for exploitation of PWFA and its advantages for acceleration and high-brightness beam generation, but extends the parameter range accessible for PWFA and, through the added benefit of co-location of inherently synchronized laser pulses, enables high-precision pump/probing, injection, seeding and unique experimental constellations, e.g., for beam coordination and collision experiments. We report on the accelerating progress of the approach achieved in a series of collaborative experiments and discuss future prospects and potential impact.

43 PARTICLE ACCELERATORS↗

Engineering Surface Oxygenated Functionalities on Commercial Carbon toward Ultrafast Sodium Storage in Ether-Based Electrolytes

The pursuit of a high-capacity anode material has been urgently required for commercializing sodium-ion batteries with a high energy density and an improved working safety. In the absence of thermodynamically stable sodium intercalated compounds with graphite, constructing nanostructures with expanded interlayer distances is still the mainstream option for developing high-performance carbonaceous anodes. In this regard, a surface-functionalized and pore-forming strategy through a facile CO 2 thermal etching route was rationally adopted to engineer negligible oxygenated functionalities on commercial carbon for boosting the sodium storage process. Benefitted from the abundant ionic/electronic pathways and more active reaction sites in the microporous structure with noticeable pseudocapacitive behaviors, the functionalized porous carbon could achieve a highly reversible capacity of 505 mA h g -1 at 50 mA g -1 , an excellent rate performance of 181 mA h g -1 at 16,000 mA g -1 , and an exceptional rate cycle stability of 176 mA h g -1 at 3200 mA g -1 over 1000 cycles. These outstanding electrochemical properties should be ascribed to a synergistic mechanism, fully utilizing the graphitic and amorphous structures for synchronous intercalations of sodium ions and solvated sodium ion compounds, respectively. Finally, the controllable generation and evolution of a robust but thin solid electrolyte interphase film with the emergence of obvious capacitive reactions on the defective surface, favoring the rapid migration of sodium ions and solvated species, also contribute to a remarkable electrochemical performance of this porous carbon black.

25 ENERGY STORAGE↗

Control Design of Passive Grid-Forming Inverters in Port-Hamiltonian Framework

This article presents a modified dispatchable virtual oscillator control approach for achieving the passivity of gridforming inverters (GFMs), without assuming constant voltage and constant frequency. The proposed control framework utilizes the Port-Hamiltonian (PH) based structure that mimics the behaviors of coupled harmonic oscillators, along with an energy ‘pumpingor-damping’ block and the Control by Interconnection (CbI) technique, to render the inverter passive. Once passivity is achieved, transient stability of the system will be guaranteed. The proposed control framework is composed of three loops: an outer power dispatching loop that generates the voltage and frequency references, a virtual oscillator loop that emulates the spontaneous synchronization of oscillators, and an inductor current loop that maintains lossless interconnection in PH systems. In conclusion, the study shows that the proposed control approach ensures the passivity of GFMs, facilitating the transient stability design of multi-inverter systems, as interconnections of passive systems remain passive and stable.

42 ENGINEERING↗

Phosphor thermometry device for synchronized acquisition of luminescence lifetime decay and intensity on thermal barrier coatings

A phosphor thermometry device includes a laser that generates a laser pulse onto a thermal barrier coating (TBC) applied onto a substrate. A metallic bond coat layer is on the substrate. A ceramic top coat layer is on the bond coat layer and includes an undoped layer and a doped sensing layer having co-doped first and second rare-earth luminescent dopants that emit respective first and second different emission wavelengths upon excitation by the laser pulse. A detector receives reflected, convoluted luminescence signals from the TBC. First and second photomultiplier devices detect respective first and second different emission wavelengths of the convoluted luminescence signals. A controller receives and processes signals generated from respective first and second photomultiplier devices and determines luminescence lifetime decay and intensity variations for each of the respective first and second rare-earth luminescent dopants for temperature monitoring of the TBC.

Fouliard, Quentin↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Efficacy of vibro-impact energy harvesting absorbers on controlling dynamical systems under vortex-induced vibrations and base excitation

Here this study investigates improving the efficacy of an energy harvesting absorber's ability to control a structure under vortex-induced vibrations, base excitation, and a combination of the two by including mechanical amplitude stoppers. The nonlinear reduced-order model is developed through modifying trilinear spring models to represent the impact forces, a modified van der Pol oscillator to represent the forcing due to the vortex-induced vibrations and using the Euler-Lagrange principle to express the equations of motion. It is seen that a soft stopper stiffness and a 5mm gap performs the most effectively of increasing the power generated from the absorber while still greatly reducing the primary structure's amplitude. By changing the stopper's location towards the middle of the energy harvesting absorber, the large effects of the impact forces are reduced and improves the efficacy of medium and hard stopper stiffnesses to generate near the amount of power the soft stopper does, while greatly improving the control of the primary structure. When the system is under combined loadings, the large oscillations of the synchronization region cause the effective configuration to be that of a 27.5 mm gap with soft stiffnesses. The results shows that medium stiffness stoppers with small gaps generate large aperiodic regions due to the high impact force. When the oscillations are close to the stoppers, the beating phenomenon is observed and is not overpowered by the vibro-impact force.

16 TIDAL AND WAVE POWER↗