Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “standard normal variate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

278 records · Page 16

Quantification of mitral regurgitation by automated cardiac output measurement: experimental and clinical validation

OBJECTIVES: To develop and validate an automated noninvasive method to quantify mitral regurgitation. BACKGROUND: Automated cardiac output measurement (ACM), which integrates digital color Doppler velocities in space and in time, has been validated for the left ventricular (LV) outflow tract but has not been tested for the LV inflow tract or to assess mitral regurgitation (MR). METHODS: First, to validate ACM against a gold standard (ultrasonic flow meter), 8 dogs were studied at 40 different stages of cardiac output (CO). Second, to compare ACM to the LV outflow (ACMa) and inflow (ACMm) tracts, 50 normal volunteers without MR or aortic regurgitation (44+/-5 years, 31 male) were studied. Third, to compare ACM with the standard pulsed Doppler-two-dimensional echocardiographic (PD-2D) method for quantification of MR, 51 patients (61+/-14 years, 30 male) with MR were studied. RESULTS: In the canine studies, CO by ACM (1.32+/-0.3 liter/min, y) and flow meter (1.35+/-0.3 liter/min, x) showed good correlation (r=0.95, y=0.89x+0.11) and agreement (deltaCO(y-x)=0.03+/-0.08 [mean+/-SD] liter/min). In the normal subjects, CO measured by ACMm agreed with CO by ACMa (r=0.90, p < 0.0001, deltaCO=-0.09+/-0.42 liter/min), PD (r=0.87, p < 0.0001, deltaCO=0.12+/-0.49 liter/min) and 2D (r=0.84, p < 0.0001, deltaCO=-0.16+/-0.48 liter/min). In the patients, mitral regurgitant volume (MRV) by ACMm-ACMa agreed with PD-2D (r= 0.88, y=0.88x+6.6, p < 0.0001, deltaMRV=2.68+/-9.7 ml). CONCLUSIONS: We determined that ACM is a feasible new method for quantifying LV outflow and inflow volume to measure MRV and that ACM automatically performs calculations that are equivalent to more time-consuming Doppler and 2D measurements. Additionally, ACM should improve MR quantification in routine clinical practice.

Non-NASA Center↗

Liquid Interfacial Electron Microscopy Identifies Nanogalvanic Corrosion in Pearlitic Steel

The nanoscale mechanisms of localized corrosion in low carbon steels have remained elusive due to the complexity of studying the degradative material behavior at nanoscale solid-liquid interfaces. We identified various steps in the nanogalvanic corrosion processes using in-situ liquid-cell scanning transmission electron microscopy (STEM) using a microfluidic holder by Hummingbird Scientific. Initial work, performed at low magnification, identified the initiation point on a 1018 low-carbon steel surface. This initiation point was determined to be a triple junction of two ferrite grains bridging a cementite grain in contact with a baseline electrolyte of 6 uM CO2 dissolved in a buffered (2.78 uM Na2SO4) aqueous solution, pH 6.1. The pre-etched low-carbon steel surface was prepared using focused ion beam lift-out procedures to extract a cross-section of the low-carbon steel surface, which then was thinned to about 150 nm and transferred to a SiN membrane microfluidic window. The transfer was made using a lift-out needle to attach the low-carbon steel lamella to the corner of the SiN window, and then Pt/C deposition held the lamella in contact with the window while it was released from the lift out needle. To identify the triple point on the low carbon steel lamella, prior to attachment on the SiN window, the sample was characterized for compositional variations with energy dispersive x-ray spectroscopy mapping, grain orientation and phase mapping with precession electron diffraction, and thickness mapping with energy filtered transmission electron microscopy. This pre-characterization prior to the in-situ experiment provided a map of the multiphase and multigrain structure, where the in-situ liquid cell imaging provided a clear understanding of the initiation point on the sample. These data were cross-correlated to paint a holistic picture of the triple junction site, enabling low electron-fluence in-situ snapshot imaging to avoid dominating the native corrosion reactions with effects from the incident electron beam. This initial result identified that localized, nanogalvanic corrosion at the phase interface was the dominant corrosion process in the low-carbon steel, so we next targeted the observation of an array of these nanogalvanic features phase boundaries in a pearlite grain. Near-surface ferrite/cementite phase interfaces that typify pearlitic low-carbon steel were extracted, pre-characterized, and imaged for the in-situ corrosion processes. The sample was a cross-section from a pearlite grain, with alternating ferrite and cementite grains that extended microns down from the pre-etched low-carbon steel pipe surface. After contact with a buffered aqueous solution, the phase boundaries between the ferrite and cementite began to dissolve, with observable material loss and thickness changes in the dark-field and bright-field STEM images. Within minutes, the corrosion front proceeded deeper into the material, claiming a thin layer of ferrite around all exposed phase boundaries before progressing laterally into the ferrite matrix, converting the ferrite to corrosion product normal to each buried cementite grain. Formation of the corrosion product causes a volumetric expansion, creating a lateral wedging force that mechanically ejects the cementite grains from their grooves and leaves behind percolation channels into the steel substructure. Rapid and deleterious, this nanogalvanic corrosion pathway represents an important target for understanding and preventing run-away degradation in this common building material. Observation of this corrosion mechanism was enabled by the combination of pre-characterization using standard structural, grain, and compositional analysis in the TEM, which provides maps for understanding the reaction propagation captured in low-dose, in-situ, liquid-cell STEM.

corrosion↗

IAEA Coordinated Research Project on Master Curve Approach to Monitor Fracture Toughness of RPV Steels: Final Results of the Experimental Exercise to Support Constraint Effects

The precracked Charpy single-edge notched bend, SE(B), specimen (PCC) is the most likely specimen type to be used for determination of the reference temperature, T0, with reactor pressure vessel (RPV) surveillance specimens. Unfortunately, for many RPV steels, significant differences have been observed between the T0 temperature for the PCC specimen and that obtained from the 25-mm thick compact specimen [1TC(T)], generally considered the standard reference specimen for T0. This difference in T0 has often been designated a specimen bias effect, and the primary focus for explaining this effect is loss of constraint in the PCC specimen. The International Atomic Energy Agency (IAEA) has developed a coordinated research project (CRP) to evaluate various issues associated with the fracture toughness Master Curve for application to light-water RPVs. Topic Area 1 of the CRP is focused on the issue of test specimen geometry effects, with emphasis on determination of T0 with the PCC specimen and the bias effect. Topic Area 1 has an experimental part and an analytical part. Participating organizations for the experimental part of the CRP performed fracture toughness testing of various steels, including the reference steel JRQ (A533-B-1) often used for IAEA studies, with various types of specimens under various conditions. Additionally, many of the participants took part in a round robin exercise on finite element modeling of the PCVN specimen, discussed in a separate paper. Results from fracture toughness tests are compared with regard to effects of specimen size and type on the reference temperature T0. It is apparent from the results presented that the bias observed between the PCC specimen and larger specimens for Plate JRQ is not nearly as large as that obtained for Plate 13B (-11 C vs -37 C) and for some of the results in the literature (bias values as much as -45 C). This observation is consistent with observations in the literature that show significant variations in the bias that are dependent on the specific materials being tested. There are various methods for constraint adjustments and two methods were used that reduced the bias for Plate 13B from -37 C to -13 C in one case and to -11 C in the second case. Unfortunately, there is not a consensus methodology available that accounts for the differences observed with different materials. Increasing the Mlim value in the ASTM E-1921 to ensure no loss of constraint for the PCC specimen is not a practicable solution because the PCC specimen is derived from CVN specimens in RPV surveillance capsules and larger specimens are normally not available. Resolution of these differences are needed for application of the master curve procedure to operating RPVs, but the research needed for such resolution is beyond the scope of this CRP.

36 MATERIALS SCIENCE↗

Thermal response of a series- and parallel-connected solar energy storage to multi-day charge sequences

The thermal response of a multi-tank thermal storage was studied under variable charge conditions. Tests were conducted on an experimental apparatus that simulated the thermal charging of the storage system by a solar collector over predetermined (prescribed) daylong periods. The storage was assembled from three standard 270 L hot-water storage tanks each charged through coupled, side-arm, natural convection heat exchangers which were connected in either a series- or parallel-flow configuration. Both energy storage rates and tank temperature profiles were experimentally measured during charge periods representative of two consecutive clear days or combinations of a clear and overcast day. During this time, no draw-offs were conducted. Of particular interest was the effect of rising and falling charge-loop temperatures and collector-loop flow rate on storage tank stratification levels. Results of this study show that the series-connected thermal storage reached high levels of temperature stratification in the storage tanks during periods of rising charge temperatures and also limited destratification during periods of falling charge temperature. This feature is a consequence of the series-connected configuration that allowed sequential stratification to occur in the component tanks and energy to be distributed according to temperature level. This effect was not observed in the parallel charge configuration. A further aspect of the study investigated the effect of increasing charge-loop flow rate on the temperature distribution within the series-connected storage and showed that, at high flow rates, the temperature distributions were found to be similar to those obtained during parallel charging. A disadvantage of both the high-flow series-connected and parallel-connected multi-tank storage is that falling charge-loop temperatures, which normally occur in the afternoon, tend to mix and destratify the storage tanks. (author)

14 SOLAR ENERGY↗

Self-Referencing Hartmann Test for Large-Aperture Telescopes

A method is proposed for end-to-end, full aperture testing of large-aperture telescopes using an innovative variation of a Hartmann mask. This technique is practical for telescopes with primary mirrors tens of meters in diameter and of any design. Furthermore, it is applicable to the entire optical band (near IR, visible, ultraviolet), relatively insensitive to environmental perturbations, and is suitable for ambient laboratory as well as thermal-vacuum environments. The only restriction is that the telescope optical axis must be parallel to the local gravity vector during testing. The standard Hartmann test utilizes an array of pencil beams that are cut out of a well-corrected wavefront using a mask. The pencil beam array is expanded to fill the full aperture of the telescope. The detector plane of the telescope is translated back and forth along the optical axis in the vicinity of the nominal focal plane, and the centroid of each pencil beam image is recorded. Standard analytical techniques are then used to reconstruct the telescope wavefront from the centroid data. The expansion of the array of pencil beams is usually accomplished by double passing the beams through the telescope under test. However, this requires a well-corrected, autocollimation flat, the diameter or which is approximately equal to that of the telescope aperture. Thus, the standard Hartmann method does not scale well because of the difficulty and expense of building and mounting a well-corrected, large aperture flat. The innovation in the testing method proposed here is to replace the large aperture, well-corrected, monolithic autocollimation flat with an array of small-aperture mirrors. In addition to eliminating the need for a large optic, the surface figure requirement for the small mirrors is relaxed compared to that required of the large autocollimation flat. The key point that allows this method to work is that the small mirrors need to operate as a monolithic flat only with regard to tip/tilt and not piston because in collimated space piston has no effect on the image centroids. The problem of aligning the small mirrors in tip/tilt requires a two-part solution. First, each mirror is suspended from a two-axis gimbal. The orientation of the gimbal is maintained by gravity. Second, the mirror is aligned such that the mirror normal is parallel to gravity vector. This is accomplished interferometrically in a test fixture. Of course, the test fixture itself needs to be calibrated with respect to gravity.

Korechoff, Robert P.↗

Studies of the Correlation Between Ionospheric Anomalies and Seismic Activities in the Indian Subcontinent

The VLF (Very Low Frequency) signals are long thought to give away important information about the Lithosphere-Ionosphere coupling. It is recently established that the ionosphere may be perturbed due to seismic activities. The effects of this perturbation can be detected through the VLF wave amplitude. There are several methods to find this correlations and these methods can be used for the prediction of these seismic events. In this paper, first we present a brief history of the use of VLF propagation method for the study of seismo-ionospheric correlations. Then we present different methods proposed by us to find out the seismo-ionospheric correlations. At the Indian Centre for Space Physics, Kolkata we have been monitoring the VTX station at Vijayanarayanam from 2002. In the initial stage, we received 17 kHz signal and latter we received 18.2 kHz signal. In this paper, first we present the results for the 17 kHz signal during Sumatra earthquake in 2004 obtained from the terminator time analysis method. Then we present much detailed and statistical analysis using some new methods and present the results for 18.2 kHz signal. In order to establish the correlation between the ionospheric activities and the earthquakes, we need to understand what are the reference signals throughout the year. We present the result of the sunrise and sunset terminators for the 18.2 kHz signal as a function of the day of the year for a period of four years, viz, 2005 to 2008 when the solar activity was very low. In this case, the signal would primarily be affected by the Sun due to normal sunrise and sunset effects. Any deviation from this standardized calibration curve would point to influences by terrestrial (such as earthquakes) and extra-terrestrial (such as solar activities and other high energy phenomena). We present examples of deviations which occur in a period of sixteen months and show that the correlations with seismic events is significant and typically the highest deviation in terminator shift takes place up to a couple of days prior to the seismic event. We introduce a new method where we find the effects of the seismic activities on D-layer preparation time (DLPT) and the D-layer disappearance time (DLDT). We identify those days in which DLPT and DLDT exhibit deviations from the average value and we correlate those days with seismic events. Separately, we compute the energy release by the earthquakes and using this, we compute the total energy released locally from distant earthquakes and find correlations of the deviations with them. In this case also we find pre-cursors a few days before the seismic events. In a third approach, we consider the nighttime fluctuation method (differently quantified than the conventional way). We analyzed the nighttime data for the year 2007 to check the correlation between the night time fluctuation of the signal amplitude and the seismic events. Using the statistical method for all the events of the year and for the individual individual earthquakes (Magnitude > 5) we found that the night time signal amplitude becomes very high on three days prior to the seismic events.

58 GEOSCIENCES↗

Evaluation of global simulations of aerosol particle and cloud condensation nuclei number, with implications for cloud droplet formation

A total of 16 global chemistry transport models and general circulation models have participated in this study; 14 model shave been evaluated with regard to their ability to reproduce the near-surface observed number concentration of aerosol particles and cloud condensation nuclei (CCN), as well as derived cloud droplet number concentration (CDNC). Model results for the period 2011–2015 are compared with aerosol measurements(aerosol particle number, CCN and aerosol particle composition in the submicron fraction) from nine surface stations located in Europe and Japan.The evaluation focuses on the ability of models to simulate the average across time state in diverse environments and on the seasonal andshort-term variability in the aerosol properties. There is no single model that systematically performs best across all environments represented by the observations. Models tend to underestimate the observed aerosol particle and CCN number concentrations, with average normalized mean bias (NMB) of all models and for all stations, where dataare available, of –24% and –35% for particles with dry diameters <50 and <120 nm, as well as –36% and –34% for CCNat supersaturations of 0.2% and 1.0%, respectively. Yet, they seem to behave differently for particles activating at very low supersaturations (<0.1%) than at higher ones. A total of 15 models have been used to produce ensemble annual median distributions of relevant parameters. The model diversity (defined as the ratio of standard deviation to mean) is up to about 3 for simulated N 3 (number concentration of particles with dry diameters larger than 3 nm) and up to about 1 for simulated CCN in the extra-polar regions. A global mean reduction of a factor of about 2 is found in the model diversity for CCN at a supersaturation of 0.2% (CCN 0.2 ) compared to that for N 3 , maximizing over regions where new particle formation is important. An additional model has been used to investigate potential causes of model diversity in CCN and bias compared to the observations by performing a perturbed parameter ensemble (PPE) accounting for uncertainties in 26 aerosol-related model input parameters. This PPE suggests that biogenic secondary organic aerosol formation and the hygroscopic properties of the organic material are likely to be the major sources of CCN uncertainty in summer, with dry deposition and cloud processing being dominant in winter. Models capture the relative amplitude of the seasonal variability of the aerosol particle number concentration for all studied particle sizes with available observations (dry diameters larger than 50, 80 and 120 nm). The short-term persistence time (on the order of a few days) of CCN concentrations, which is a measure of aerosol dynamic behavior in the models, is underestimated o naverage by the models by 40% during winter and 20% in summer. In contrast to the large spread in simulated aerosol particle and CCN number concentrations, the CDNC derived from simulated CCN spectra is less diverse and in better agreement with CDNC estimates consistently derived from the observations (average NMB –13% and –22% for updraft velocities 0.3 and 0.6m s –1 , respectively). In addition, simulated CDNC is in slightly better agreement with observationally derived values at lower than at higher updraft velocities (index of agreement 0.64 vs. 0.65). The reduced spread of CDNC compared to that of CCN is attributed to the sublinear response of CDNC to aerosol particle number variations and the negative correlation between the sensitivities of CDNC to aerosol particle number concentration( ∂ N d / ∂ N a ) and to updraft velocity ( ∂ N d / ∂ w ). Overall, we find that while CCN is controlled by both aerosol particle number and composition, CDNC is sensitive to CCN at low and moderate CCN concentrations and to the updraft velocity when CCN levels are high. Discrepancies are found in sensitivities ∂ N d / ∂ N a and ∂ N d / ∂ w ; models may be predisposed to be too“aerosol sensitive” or “aerosol insensitive” in aerosol–cloud–climate interaction studies, even if they may capture average droplet numbers well.This is a subtle but profound finding that only the sensitivities can clearly reveal and may explain inter-model biases on the aerosol indirect effect.

54 ENVIRONMENTAL SCIENCES↗

The feasibility of a regional CTDI{sub vol} to estimate organ dose from tube current modulated CT exams

Purpose: In AAPM Task Group 204, the size-specific dose estimate (SSDE) was developed by providing size adjustment factors which are applied to the Computed Tomography (CT) standardized dose metric, CTDI{sub vol}. However, that work focused on fixed tube current scans and did not specifically address tube current modulation (TCM) scans, which are currently the majority of clinical scans performed. The purpose of this study was to extend the SSDE concept to account for TCM by investigating the feasibility of using anatomic and organ specific regions of scanner output to improve accuracy of dose estimates. Methods: Thirty-nine adult abdomen/pelvis and 32 chest scans from clinically indicated CT exams acquired on a multidetector CT using TCM were obtained with Institutional Review Board approval for generating voxelized models. Along with image data, raw projection data were obtained to extract TCM functions for use in Monte Carlo simulations. Patient size was calculated using the effective diameter described in TG 204. In addition, the scanner-reported CTDI{sub vol} (CTDI{sub vol,global}) was obtained for each patient, which is based on the average tube current across the entire scan. For the abdomen/pelvis scans, liver, spleen, and kidneys were manually segmented from the patient datasets; for the chest scans, lungs and for female models only, glandular breast tissue were segmented. For each patient organ doses were estimated using Monte Carlo Methods. To investigate the utility of regional measures of scanner output, regional and organ anatomic boundaries were identified from image data and used to calculate regional and organ-specific average tube current values. From these regional and organ-specific averages, CTDI{sub vol} values, referred to as regional and organ-specific CTDI{sub vol}, were calculated for each patient. Using an approach similar to TG 204, all CTDI{sub vol} values were used to normalize simulated organ doses; and the ability of each normalized dose to correlate with patient size was investigated. Results: For all five organs, the correlations with patient size increased when organ doses were normalized by regional and organ-specific CTDI{sub vol} values. For example, when estimating dose to the liver, CTDI{sub vol,global} yielded a R{sup 2} value of 0.26, which improved to 0.77 and 0.86, when using the regional and organ-specific CTDI{sub vol} for abdomen and liver, respectively. For breast dose, the global CTDI{sub vol} yielded a R{sup 2} value of 0.08, which improved to 0.58 and 0.83, when using the regional and organ-specific CTDI{sub vol} for chest and breasts, respectively. The R{sup 2} values also increased once the thoracic models were separated for the analysis into females and males, indicating differences between genders in this region not explained by a simple measure of effective diameter. Conclusions: This work demonstrated the utility of regional and organ-specific CTDI{sub vol} as normalization factors when using TCM. It was demonstrated that CTDI{sub vol,global} is not an effective normalization factor in TCM exams where attenuation (and therefore tube current) varies considerably throughout the scan, such as abdomen/pelvis and even thorax. These exams can be more accurately assessed for dose using regional CTDI{sub vol} descriptors that account for local variations in scanner output present when TCM is employed.

60 APPLIED LIFE SCIENCES↗