Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrum monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Design and fabrication of optical thin films for remote sensing instruments

Optical thin films designed for multispectral band-pass filters and a primary Ag mirror were deposited on radiation-resistant glass by ion-beam-assisted deposition. The filters and mirror are for use in the optical payload of a remote sensing instrument. The optical parameters of the films and mirror were optimized by using admittance loci analysis. The simulation shows that the band-pass filters can achieve average transmittances of 95% in the blue (B1), green (B2), red (B3), near-infrared (B4), and panchromatic (400-900 nm) spectral ranges and an average reflectance of 99% for the primary Ag mirror in the visible spectrum. The corresponding properties of the films were investigated by in situ optical monitoring, spectrometry, and high-resolution transmission electron microscopy. It was found that the average transmittances are above 85% for all five band-pass filters, with a rejection transmittance below 1% in the spectral range of 350-1100 nm. The average reflectance of the primary Ag mirror (with a protective coating) is above 98%. Interference coatings were added to the basic protected silver design to enhance the reflectance in the visible spectral range. Furthermore, to investigate the optical stability of optical thin films for aerospace applications, a space environment was simulated by using a Co{sup 60} gamma ({gamma}) radiation source (total doses of 35 krad and 1 Mrad). The experimental results indicate that both the dielectric thin film stacks and radiation-protected glass are resistant to {gamma} radiation in the simulated space environment.

36 MATERIALS SCIENCE↗

Photodissociation quantum yields of CO2 between 1200 and 1500 A

Measurements of the photodissociation quantum yields of CO2 have been carried out using various atomic line sources between 1200 and 1500 A. The production of CO was monitored by resonance fluorescence, and the results indicate that where the CO2 absorption spectrum is continuous, the CO quantum yield is high, but where there is structure, the yield is low.

Slanger, T. G.↗

The nonstellar continuum of the Seyfert galaxy NGC 7213

The optical continuum of the nearby Seyfert galaxy NGC 7213 is decomposed into stellar and nonstellar components, and the spectrum at X-ray energies is derived from observations made with the Monitor Proportional Counter and the Imaging Proportional Counter aboard the Einstein Observatory. These results are used to obtain conclusions about the galaxy's column density and spectral index, covering fraction and visual extinction, and thermal emission. Ultraviolet, infrared, and radio observations published elsewhere are then combined with the new data to produce the overall continuum.

Halpern, J. P.↗

Cracked rotor demonstration

The purpose of this demonstration is to observe the behavior of a rotor with a single crack. This will be presented in oscilloscope orbits, 2X POLAR PLOTS, and spectrum cascade diagrams. Crack detection must be observed in all three formats and monitored over a period of time or start-ups. The change in the 2X behavior pattern provides an early warning that a crack potentially exists and that it is likely propagating toward total rotor fracture.

Bosmans, R. F.↗

The Earth Occultation Technique with the Burst and Transient Source Experiment

The Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (CGRO) is an uncollimated all-sky instrument sensitive to photons in the 20 keV to 1 MeV range. Since CGRO orbits the Earth at an altitude of 450 km, about 33% of the sky, as viewed with BATSE, is covered by the Earth at any given time. The entire sky is subject to Earth Occultation for some portion of CGRO's 52 day precession period. When a source sets below (or rises above) the Earth's limb, atmospheric attenuation produces step-like features in the BATSE data. The observed change in count rate in several energy bands provides a measurement of the source intensity and spectrum without sophisticated background models. These occultation features are used to locate and monitor astrophysical sources with BATSE when the source signal can be separated from the detector background. Examples of step searches, spectra light curves, and transform imaging are presented. Systematic uncertainties due to source confusion, detector response, and rapid background variations are discussed.

Wilson, C. A.↗

Hyperspectral Imaging Sensors and the Marine Coastal Zone

Hyperspectral imaging sensors greatly expand the potential of remote sensing to assess, map, and monitor marine coastal zones. Each pixel in a hyperspectral image contains an entire spectrum of information. As a result, hyperspectral image data can be processed in two very different ways: by image classification techniques, to produce mapped outputs of features in the image on a regional scale; and by use of spectral analysis of the spectral data embedded within each pixel of the image. The latter is particularly useful in marine coastal zones because of the spectral complexity of suspended as well as benthic features found in these environments. Spectral-based analysis of hyperspectral (AVIRIS) imagery was carried out to investigate a marine coastal zone of South Florida, USA. Florida Bay is a phytoplankton-rich estuary characterized by taxonomically distinct phytoplankton assemblages and extensive seagrass beds. End-member spectra were extracted from AVIRIS image data corresponding to ground-truth sample stations and well-known field sites. Spectral libraries were constructed from the AVIRIS end-member spectra and used to classify images using the Spectral Angle Mapper (SAM) algorithm, a spectral-based approach that compares the spectrum, in each pixel of an image with each spectrum in a spectral library. Using this approach different phytoplankton assemblages containing diatoms, cyanobacteria, and green microalgae, as well as benthic community (seagrasses), were mapped.

Richardson, Laurie L.↗

XTE J1946+274: An Enigmatic X-Ray Pulsar

XTE J1946+274 = GRO J1944+26 is a 15.8-s X-ray pulsar discovered simultaneously by the Rossi X-ray Timing Explorer (RXTE) and the Burst and Transient Source Experiment (BATSE) in September 1998. Follow-up optical/IR observations resulted in the discovery of a Be star companion. Our pulse timing analysis of BATSE and RXTE data indicates that the orbital period is approximately 169 days. Since its discovery in 1998, XTE J1946+274 has undergone 13 outbursts. These outbursts axe not regularly spaced. They occur approximately twice per orbit and are not locked in orbital phase, unlike most Be/X-ray transient systems. A possible explanation for this is a global-one armed oscillation or density perturbation propagating rapidly in the Be star's disk. We will investigate radial velocity variations in the central peak of the H-alpha line to look for evidence of such a perturbation. From 2001 March-September, we regularly monitored XTE J1946+274 with the RXTE PCA. We will demonstrate that the spectrum appears to be varying with orbital phase, based on the 2001 and 1998 RXTE PCA observations. We will also present histories of pulsed frequency and flux.

Wilson, Colleen A.↗

Exploring PV on the Red Planet: Mars Array Technology Experiment and Dust Accumulation and Removal Technology

The environment on the surface of Mars is different in several critical ways from the orbital environment in which space solar arrays normally operate. Some important differences are: 1) Low intensity, low temperature operation; 2) Spectrum modified by atmospheric dust, varies with time; 3) Indirect sunlight; 4) Possibility of dust atoms at some times of year; 5) Deposited dust; 6) Wind; 7) Peroxide-rich reactive soil. We are developing two experiments to test operation of solar arrays on the surface of Mars, to be flown on the 2001 Surveyor Lander mission. The Mars Array Technology Experiment (MATE) will test the operation of several types of solar cells under Mars conditions, and determine the direct and scattered solar spectrum at the surface. The Dust Accumulation and Removal Technology (DART) experiment will monitor the amount of dust deposition on a target solar cell, measure the characteristics of the dust, and test the feasibility of dust removal.

Landis, Geoffrey A.↗

Plant Habitat (PH)

The International Space Station (ISS) will soon have a platform for conducting fundamental research of Large Plants. Plant Habitat (PH) is designed to be a fully controllable environment for high-quality plant physiological research. PH will control light quality, level, and timing, temperature, CO2, relative humidity, and irrigation, while scrubbing ethylene. Additional capabilities include leaf temperature and root zone moisture and oxygen sensing. The light cap will have red (630 nm), blue (450 nm), green (525 nm), far red (730 nm) and broad spectrum white LEDs. There will be several internal cameras (visible and IR) to monitor and record plant growth and operations.

Advanced Plant Habitat↗

IMPLEMENTING THE STANDARD SPECTRUM METHOD FOR ANALYSIS OF β-γ COINCIDENCE SPECTRA

The standard deconvolution analysis tool (SDAT) algorithms were developed and tested at the University of Texas at Austin. These algorithms utilize the standard spectrum technique for spectral analysis of {beta}-{gamma} coincidence spectra for nuclear explosion monitoring. Work has been conducted under this contract to implement these algorithms into a useable scientific software package with a graphical user interface. Improvements include the ability to read in PHD formatted data, gain matching, and data visualization. New auto-calibration algorithms were developed and implemented based on 137Cs spectra for assessment of the energy vs. channel calibrations. Details on the user tool and testing are included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High accuracy absorbance spectrophotometers

Spectrophotometers and spectroscopy processes are described that can provide for in-line calibration at every spectral acquisition as well as for continuous response correction during sample processing. The spectrophotometers include multiple polychromatic light sources that include characteristic emission spectra for use as an internal wavelength drift calibration system that is independent of environmental factors. Correction functions provided by the internal calibration process can be applied continuously and across an entire sample spectrum. The intensity response of each spectrometer in a spectrophotometer can also be monitored and continuously corrected for stray light, dark current, readout noise, etc.

O'Rourke, Patrick E.↗

Estimation of Sorption Behavior of Europium onto Ca-Al-Si Hydrate by Fluorescence Analysis - 19222

As a nuclide migration evaluation in the radioactive waste disposal system, the sorption behaviors of Eu, which is a multivalent metal ion, onto Ca-Al-Si hydrates (including Ca-Si hydrates) were examined in this study. In the sorption experiments, Ca-Al-Si hydrates were handled without drying process in consideration of saturated groundwater environment. The sorption behaviors of Eu onto Ca-Al-Si hydrate with various combinations of Ca/Si molar ratio and Al/Si molar ratio were monitored by using the Ca, Al, Si and Eu concentrations, the fluorescence emission spectrum and the fluorescence lifetime. In addition, the structural changes of Ca-Al-Si hydrates by Eu were evaluated by Raman spectrum measurement. In the results, the fluorescence lifetimes of most samples remarkably exceeded that of Eu(OH){sub 3}. This suggests that Eu ions are immobilized by not only Ca-Si hydrates but also Ca-Al-Si hydrates. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Injection of Direct-Sequence Spread Spectrum Pilot Tones into Beamline Components as a Means of Downconverter Stabilization and Real-Time Receiver Calibration

Beamline components used for diagnostic elements often rely on thermal stabilization, continual physical maintenance (ie. tuning), and frequent beam-based calibrations to maintain specified performance. Direct-sequence spread spectrum (DSSS) pilot tones injected into a particular element and combined with the beam-derived signal can subsequently be separated and used to assess performance degradation. In addition, the DSSS tone can be used as a real-time calibration signal, without interference to the intended diagnostic signal. This paper demonstrates such a technique in the design of a Beam Current Monitor downconverter system, as an intended upgrade to the CEBAF Beam Loss Accounting system. A brief spread-spectrum primer is included, as well as a description of appropriate spreading codes and their generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Oscillation of the Electron-Capture Decay Probability of Pm-142

We have searched for time modulation of the electron capture decay probability of 142Pm in an attempt to confirm a recent claim from a group at the Gesellschaft fur Schwerionenforschung (GSI). We produced 142Pm via the 124Sn(23Na, 5n)142Pm reaction at the Berkeley 88-Inch Cyclotron with a bombardment time short compared to the reported modulation period. Isotope selection by the Berkeley Gas-filled Separator is followed by implantation and a long period of monitoring the 142Nd K alpha x-rays from the daughter. The decay time spectrum of the x-rays is well-described by a simple exponential and the measured half-life of 40.68(53) seconds is consistent with the accepted value. We observed no oscillatory modulation at the proposed frequency at a level 31 times smaller than that reported by Litvinov (Phys. Lett. B 664 (2008) 162). A literature search for previous experiments that might have been sensitive to the reported modulation uncovered another example in 142Eu electron-capture decay. A reanalysis of the published data shows no oscillatory behavior.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monitoring of bacteria growth using a wireless, remote query resonant-circuit sensor: application to environmental sensing

A new technique is presented for in-vivo remote query measurement of the complex permittivity spectra of a biological culture solution. A sensor comprised of a printed inductor-capacitor resonant-circuit is placed within the culture solution of interest, with the impedance spectrum of the sensor measured using a remotely located loop antenna; the complex permittivity spectra of the culture is calculated from the measured impedance spectrum. The remote query nature of the sensor platform enables, for example, the in-vivo real-time monitoring of bacteria or yeast growth from within sealed opaque containers. The wireless monitoring technique does not require a specific alignment between sensor and antenna. Results are presented for studies conducted on laboratory strains of Bacillus subtilis, Escherichia coli JM109, Pseudomonas putida and Saccharomyces cerevisiae.

Non-NASA Center↗

Optogalvanic wavelength calibration for laser monitoring of reactive atmospheric species

Laser-based techniques have been successfully employed for monitoring atmospheric species of importance to stratospheric ozone chemistry or tropospheric air quality control. When spectroscopic methods using tunable lasers are used, a simultaneously recorded reference spectrum is required for wavelength calibration. For stable species this is readily achieved by incorporating into the sensing instrument a reference cell containing the species to be monitored. However, when the species of interest is short-lived, this approach is unsuitable. It is proposed that wavelength calibration for short-lived species may be achieved by generating the species of interest in an electrical or RF discharge and using optogalvanic detection as a simple, sensitive, and reliable means of recording calibration spectra. The wide applicability of this method is emphasized. Ultraviolet, visible, or infrared lasers, either CW or pulsed, may be used in aircraft, balloon, or shuttle experiments for sensing atoms, molecules, radicals, or ions.

Webster, C. R.↗

Spread Spectrum Time Domain Reflectometry (SSTDR) and Frequency Domain Reflectometry (FDR) for Detection of Cable Anomalies Using Machine Learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas ionization solar spectral monitor (GISSMO)

We are currently developing an instrument free from optical components to measure the full-disk solar spectrum in the extreme ultraviolet regime covering wavelengths from 75-500 A. The instrument, which will be launched aboard a NASA Black Brant sounding rocket in September 1992, consists of a windowless noble gas ionization cell followed by a toroidal electrostatic analyzer to spatially disperse photoelectrons as a function of their energies. A microchannel plate based position sensitive detector will be used to detect individual electrons, indirectly returning the solar EUV spectrum.

Vickers, James S.↗