Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroscopic methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Characterization of a linear device developed for research on advanced plasma imaging and dynamics

Within the scope of long term research on imaging diagnostics for steady-state plasmas and understanding of edge plasma physics through diagnostics with conventional spectroscopic methods, we have constructed a linear electron cyclotron resonance (ECR) plasma device named Research on Advanced Plasma Imaging and Dynamics (RAPID). It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. Here, a 6 kW 2.45 GHz magnetron is used to produce steady-state hydrogen, helium, and argon plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). In order to achieve the highest possible plasma performance within the limited input parameters, wall conditioning experiments were carried out. Chamber bake-out was achieved with heating coils that were wound covering the vessel, and long-pulse electron cyclotron heating discharge cleaning was also followed after 4 days of bake-out. A uniform bake-out temperature (150 deg. C) was achieved by wrapping the vessel in high temperature thermal insulation textile and by controlling the heating coil current using a digital control system. The partial pressure changes were observed using a residual gas analyzer, and a total system pressure of 5x10{sup -8} Torr was finally reached. Diagnostic systems including a millimeter-wave interferometer, a high resolution survey spectrometer, a Langmuir probe, and an ultrasoft x-ray detector were used to provide the evidence that the plasma performance was improved as we desired. In this work, we present characterization of the RAPID device for various system conditions and configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of laser-induced plasma in supercritical water and vibrational spectroscopic study of accompanying stimulated Raman scattering

We have formed a laser-induced plasma (LIP) in supercritical water (SCW) and studied associated molecular vibrations using spectroscopic methods. The accompanying forward and backward stimulated Raman scattering (SRS) of water molecules showed anisotropic behavior at supercritical conditions (>647 K and >22.1 MPa). The Raman shift of the backward SRS indicated that attractive interactions between water molecules and excess electrons generated by the LIP were dominant in the SCW. The backward SRS spectrum provided a microscopic view of the hydration environment around an excess electron, which is useful for controlling electron-driven chemical reactions and materials processing in SCW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma dynamics in laboratory-produced current sheets

Evolution of currents and Ampere forces in current sheets are analyzed on the basis of magnetic measurements. Two new effects are observed in the current distributions at the later stage of the sheet evolution: first, a broadening of the current area at the side edges of the current sheet; second, a generation of reverse currents followed by their propagation from the edges to the center of the sheet. Super-thermal plasma flows moving across the width of the current sheet are observed by spectroscopic methods. The energies of plasma jets are consistent with the spatial structure and time dependences of the Ampere forces in the current sheets. The assumption is advanced that plasma acceleration may be more effective at the regions with lower plasma density, which are located at some distances from the sheet mid-plane. Generation of reverse currents provides an additional confirmation of transfer of energetic plasma jets toward the sheet edges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Spectroscopic Diagnostics Of Dusty Plasma In RF Discharge

The parameters of the buffer plasma containing dust particles were measured by means of spectroscopic methods. The change in the emission spectrum of the buffer plasma with addition of dust was observed. It seems to relate to changing in temperature and number density of electrons due to the influence of dusts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectroscopy diagnostic of dual-frequency capacitively coupled CHF{sub 3}/Ar plasma

A combined spectroscopic method of absorption, actinometry, and relative optical emission intensity is employed to determine the absolute CF{sub 2} density, the relative F and H densities, H atom excitation temperature and the electron density in dual-frequency (60/2 MHz) capacitively coupled CHF{sub 3}/Ar plasmas. The effects of different control parameters, such as high-frequency (HF) power, low-frequency (LF) power, gas pressure, gap length and content of CHF{sub 3}, on the concentration of radical CF{sub 2}, F, and H and excitation temperature are discussed, respectively. It is found that the concentration of CF{sub 2} is strongly dependent on the HF power, operating pressure and the proportion of CHF{sub 3} in feed gas, while it is almost independent of the LF power and the gap length. A higher concentration ratio of F to CF{sub 2} could be obtained in dual-frequency discharge case. Finally, the generation and decay mechanisms of CF{sub 2} and F were also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the origin of high transient anisotropies: An exemplification in a Cd-porphyrin

Transient anisotropy is a widely used spectroscopic method to access the polarization dynamics of a molecular sample. In this contribution, we present results on 5,10,15,20-tetraphenyl-porphyrinato cadmium (II) in tetrahydrofuran which exhibits values exceeding the typical range between 0.4 and −0.2 in dependence of the probe wavelength. These findings are explained by varying contributions from excited state absorption and ground state bleaching/stimulated emission. Model calculations show that time zero values and time decays are complex values that often do not correlate with the underlying physical processes. As a consequence, the interpretation of anisotropy experiments necessitates extreme care.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complexation of 5,5,7,12,12,14-hexamethyl-1,4,8,11-tetraazacyclotetradeca-7,14-diene dithiocyanate with nickel (II) acetate

The complexation of nickel acetate with tetraaza involves deprotonation of protonated amine nitrogen to form neutral ligand coordinated to the nickel via the four nitrogen atom. The dication complex is paired with thiocyanate anions. The complex was characterized by elemental analysis, UV-VIS and FTIR spectroscopic method. The crystal structure of nickel complex characterized by X-Ray crystallography and adopts square planar geometry.

36 MATERIALS SCIENCE↗

Communication: Determining the structure of the N{sub 2}Ar van der Waals complex with laser-based channel-selected Coulomb explosion

We experimentally reconstructed the structure of the N{sub 2}Ar van der Waals complex with the technique of laser-based channel-selected Coulomb explosion imaging. The internuclear distance between the N{sub 2} center of mass and the Ar atom, i.e., the length of the van der Waals bond, was determined to be 3.88 Å from the two-body explosion channels. The angle between the van der Waals bond and the N{sub 2} principal axis was determined to be 90° from the three-body explosion channels. The reconstructed structure was contrasted with our high level ab initio calculations. The agreement demonstrated the potential application of laser-based Coulomb explosion in imaging transient molecular structure, particularly for floppy van der Waals complexes, whose structures remain difficult to be determined by conventional spectroscopic methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new combined nuclear magnetic resonance and Raman spectroscopic probe applied to in situ investigations of catalysts and catalytic processes

Both Raman and nuclear magnetic resonance (NMR) spectroscopies are valuable analytical techniques capable of providing mechanistic information and thereby providing insights into chemical processes, including catalytic reactions. Since both techniques are chemically sensitive, they yield not only structural information but also quantitative analysis. In this work, for the first time, the combination of the two techniques in a single experimental apparatus is reported. This entailed the design of a new experimental probe capable of recording simultaneous measurements on the same sample and/or system of interest. The individual datasets acquired by each spectroscopic method are compared to their unmodified, stand-alone equivalents on a single sample as a means to benchmark this novel piece of equipment. The application towards monitoring reaction progress is demonstrated through the evolution of the homogeneous catalysed metathesis of 1‑hexene, with both experimental techniques able to detect reactant consumption and product evolution. This is extended by inclusion of magic angle spinning (MAS) NMR capabilities with a custom made MAS 7 mm rotor capable of spinning speeds up to 1600 Hz, quantified by analysis of the spinning sidebands of a sample of KBr. The value of this is demonstrated through an application involving heterogeneous catalysis, namely the metathesis of 2-pentene and ethene. This provides the added benefit of being able to monitor both the reaction progress (by NMR spectroscopy) and also the structure of the catalyst (by Raman spectroscopy) on the very same sample, facilitating the development of structure-performance relationships.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

χ{sup (3)} measurements of axial ligand modified high valent tin(IV) porphyrins using degenarete four wave mixing at 532nm

Porphyrins and metalloporphyrins are unique class of molecules for Nonlinear Optical applications because of their unique structure of altering the central metal atom, large extended π-system, high thermal stability, tunable shape, symmetry and synthetic versatility Here, we report χ{sup (3)} Measurements of a simple phenyl porphyrins and its highvalent tin(IV) porphyrins with Bromination characterized by UV-Visible spectroscopic method. In this study, we employed the Degenerate Four Wave Mixing technique using forward Boxcar geometry with an Nd:YAG nano second pulsed laser as source and it was found that the tin(IV) porphyrin with Bromination exhibits good χ{sup (3)} value and figure of merit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A microfluidic flow-cell for the study of the ultrafast dynamics of biological systems

The study of biochemical dynamics by ultrafast spectroscopic methods is often restricted by the limited amount of liquid sample available, while the high repetition rate of light sources can induce photodamage. In order to overcome these limitations, we designed a high flux, sub-ml, capillary flow-cell. While the 0.1 mm thin window of the 0.5 mm cross-section capillary ensures an optimal temporal resolution and a steady beam deviation, the cell-pump generates flows up to ~0.35 ml/s that are suitable to pump laser repetition rates up to ~14 kHz, assuming a focal spot-diameter of 100 μm. In addition, a decantation chamber efficiently removes bubbles and allows, via septum, for the addition of chemicals while preserving the closed atmosphere. The minimal useable amount of sample is ~250 μl.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Induction-detection electron spin resonance with spin sensitivity of a few tens of spins

Electron spin resonance (ESR) is a spectroscopic method that addresses electrons in paramagnetic materials directly through their spin properties. ESR has many applications, ranging from semiconductor characterization to structural biology and even quantum computing. Although it is very powerful and informative, ESR traditionally suffers from low sensitivity, requiring many millions of spins to get a measureable signal with commercial systems using the Faraday induction-detection principle. In view of this disadvantage, significant efforts were made recently to develop alternative detection schemes based, for example, on force, optical, or electrical detection of spins, all of which can reach single electron spin sensitivity. This sensitivity, however, comes at the price of limited applicability and usefulness with regard to real scientific and technological issues facing modern ESR which are currently dealt with conventional induction-detection ESR on a daily basis. Here, we present the most sensitive experimental induction-detection ESR setup and results ever recorded that can detect the signal from just a few tens of spins. They were achieved thanks to the development of an ultra-miniature micrometer-sized microwave resonator that was operated at ∼34 GHz at cryogenic temperatures in conjunction with a unique cryogenically cooled low noise amplifier. The test sample used was isotopically enriched phosphorus-doped silicon, which is of significant relevance to spin-based quantum computing. The sensitivity was experimentally verified with the aid of a unique high-resolution ESR imaging approach. These results represent a paradigm shift with respect to the capabilities and possible applications of induction-detection-based ESR spectroscopy and imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser frequency stabilization using bichromatic crossover spectroscopy

We propose a Doppler-free spectroscopic method named bichromatic crossover spectroscopy (BCS), which we then use for the frequency stabilization of an off-resonant frequency that does not correspond to an atomic transition. The observed BCS in the 5S{sub 1/2} → 5P{sub 1/2} transition of {sup 87}Rb is related to the hyperfine structure of the conventional saturated absorption spectrum of this transition. Furthermore, the Doppler-free BCS is numerically calculated by considering all of the degenerate magnetic sublevels of the 5S{sub 1/2} → 5P{sub 1/2} transition in an atomic vapor cell, and is found to be in good agreement with the experimental results. Finally, we successfully achieve modulation-free off-resonant locking at the center frequency between the two 5S{sub 1/2}(F = 1 and 2) → 5P{sub 1/2}(F′ = 1) transitions using a polarization rotation of the BCS. The laser frequency stability was estimated to be the Allan variance of 2.1 × 10{sup −10} at 1 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Renner-Teller effect in HCCCl{sup +}(X{sup ~2}Π) studied by zero-kinetic energy photoelectron spectroscopy and ab initio calculations

The spin-vibronic energy levels of the chloroacetylene cation up to 4000 cm{sup −1} above the ground state have been measured using the one-photon zero-kinetic energy photoelectron spectroscopic method. The spin-vibronic energy levels have also been calculated using a diabatic model, in which the potential energy surfaces are expressed by expansions of internal coordinates, and the Hamiltonian matrix equation is solved using a variational method with harmonic basis functions. The calculated spin-vibronic energy levels are in good agreement with the experimental data. The Renner-Teller (RT) parameters describing the vibronic coupling for the H—C≡C bending mode (ε{sub 4}), Cl—C≡C bending mode (ε{sub 5}), the cross-mode vibronic coupling (ε{sub 45}) of the two bending vibrations, and their vibrational frequencies (ω{sub 4} and ω{sub 5}) have also been determined using an effective Hamiltonian matrix treatment. In comparison with the spin-orbit interaction, the RT effect in the H—C≡C bending (ε{sub 4}) mode is strong, while the RT effect in the Cl—C≡C bending mode is weak. There is a strong cross-mode vibronic coupling of the two bending vibrations, which may be due to a vibronic resonance between the two bending vibrations. The spin-orbit energy splitting of the ground state has been determined for the first time and is found to be 209 ± 2 cm{sup −1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coherent phonon spectroscopy of non-fully symmetric modes using resonant terahertz excitation

We use intense terahertz (THz) frequency electromagnetic pulses generated via optical rectification in an organic crystal to drive vibrational lattice modes in single crystal Tellurium. The coherent modes are detected by measuring the polarization changes of femtosecond laser pulses reflecting from the sample surface, resulting in a phase-resolved detection of the coherent lattice motion. We compare the data to a model of Lorentz oscillators driven by the near-single-cycle broadband THz pulse. The demonstrated technique of optically probed coherent phonon spectroscopy with THz frequency excitation could prove to be a viable alternative to other time-resolved spectroscopic methods like standard THz time domain spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural dynamics of N-ethylpropionamide clusters examined by nonlinear infrared spectroscopy

In this work, the structural dynamics of N-ethylpropionamide (NEPA), a model molecule of β-peptides, in four typical solvents (DMSO, CH{sub 3}CN, CHCl{sub 3}, and CCl{sub 4}), were examined using the N—H stretching vibration (or the amide-A mode) as a structural probe. Steady-state and transient infrared spectroscopic methods in combination with quantum chemical computations and molecular dynamics simulations were used. It was found that in these solvents, NEPA exists in different aggregation forms, including monomer, dimer, and oligomers. Hydrogen-bonding interaction and local-solvent environment both affect the amide-A absorption profile and its vibrational relaxation dynamics and also affect the structural dynamics of NEPA. In particular, a correlation between the red-shifted frequency for the NEPA monomer from nonpolar to polar solvent and the vibrational excitation relaxation rate of the N—H stretching mode was observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic properties of Mn-phthalocyanine–C{sub 60} bulk heterojunctions: Combining photoemission and electron energy-loss spectroscopy

The electronic properties of co-evaporated mixtures (blends) of manganese phthalocyanine and the fullerene C{sub 60} (MnPc:C{sub 60}) have been studied as a function of the concentration of the two constituents using two supplementary electron spectroscopic methods, photoemission spectroscopy (PES) and electron energy-loss spectroscopy (EELS) in transmission. Our PES measurements provide a detailed picture of the electronic structure measured with different excitation energies as well as different mixing ratios between MnPc and C{sub 60}. Besides a relative energy shift, the occupied electronic states of the two materials remain essentially unchanged. The observed energy level alignment is different compared to that of the related CuPc:C{sub 60} bulk heterojunction. Moreover, the results from our EELS investigations show that, despite the rather small interface interaction, the MnPc related electronic excitation spectrum changes significantly by admixing C{sub 60} to MnPc thin films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On-chip spectroscopy with thermally tuned high-Q photonic crystal cavities

Spectroscopic methods are a sensitive way to determine the chemical composition of potentially hazardous materials. Here, we demonstrate that thermally tuned high-Q photonic crystal cavities can be used as a compact high-resolution on-chip spectrometer. We have used such a chip-scale spectrometer to measure the absorption spectra of both acetylene and hydrogen cyanide in the 1550 nm spectral band and show that we can discriminate between the two chemical species even though the two materials have spectral features in the same spectral region. Our results pave the way for the development of chip-size chemical sensors that can detect toxic substances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗